Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 62
Filtrar
1.
Stereotact Funct Neurosurg ; 102(2): 120-126, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38219714

RESUMO

INTRODUCTION: With recent advancements in deep brain stimulation (DBS), directional leads featuring segmented contacts have been introduced, allowing for targeted stimulation of specific brain regions. Given that manufacturers employ diverse markers for lead orientation, our investigation focuses on the adaptability of the 2017 techniques proposed by the Cologne research group for lead orientation determination. METHODS: We tailored the two separate 2D and 3D X-ray-based techniques published in 2017 and originally developed for C-shaped markers, to the dual-marker of the Medtronic SenSight™ lead. In a retrospective patient study, we evaluated their feasibility and consistency by comparing the degree of agreement between the two methods. RESULTS: The Bland-Altman plot showed favorable concordance without any noticeable systematic errors. The mean difference was 0.79°, with limits of agreement spanning from 21.4° to -19.8°. The algorithms demonstrated high reliability, evidenced by an intraclass correlation coefficient of 0.99 (p < 0.001). CONCLUSION: The 2D and 3D algorithms, initially formulated for discerning the circular orientation of a C-shaped marker, were adapted to the marker of the Medtronic SenSight™ lead. Statistical analyses revealed a significant level of agreement between the two methods. Our findings highlight the adaptability of these algorithms to different markers, achievable through both low-dose intraoperative 2D X-ray imaging and standard CT imaging.


Assuntos
Estimulação Encefálica Profunda , Humanos , Raios X , Estudos Retrospectivos , Reprodutibilidade dos Testes , Estimulação Encefálica Profunda/métodos , Algoritmos , Eletrodos Implantados
2.
Neuroimage ; 287: 120507, 2024 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-38244876

RESUMO

BACKGROUND: Childhood-onset dystonia is often progressive and severely impairs a child´s life. The pathophysiology is very heterogeneous and treatment responses vary in patients with dystonia. Factors influencing treatment effects remain to be elucidated. We hypothesize that differences in brain connectivity and fiber coherence contribute to the heterogeneity in treatment response among pediatric patients with inherited and acquired dystonia. METHODS: Twenty patients with childhood-onset dystonia were retrospectively recruited including twelve patients with inherited or idiopathic, and eight patients with acquired dystonia (mean age 10 years; 8 female/12 male). Fiber density between the internal part of the globus pallidus and selective target regions, as well as the diffusion measures of fractional anisotropy (FA) and mean diffusivity (MD) were analyzed and compared between different etiologies. RESULTS: Patients with acquired dystonia presented higher fiber density to the premotor cortex and putamen and lower FA values in the thalamus compared to patients with inherited/idiopathic dystonia. MD in the premotor cortex was higher in patients with acquired dystonia, while it was lower in the thalamus. CONCLUSION: Diffusion MRI reveals microstructural and network alterations in patients with dystonia of different etiologies.


Assuntos
Distonia , Distúrbios Distônicos , Humanos , Masculino , Feminino , Criança , Imagem de Tensor de Difusão/métodos , Distonia/diagnóstico por imagem , Estudos Retrospectivos , Encéfalo , Distúrbios Distônicos/diagnóstico por imagem , Imagem de Difusão por Ressonância Magnética , Anisotropia
3.
Z Med Phys ; 2023 Jan 28.
Artigo em Inglês | MEDLINE | ID: mdl-36717311

RESUMO

PURPOSE: In robotic stereotactic radiosurgery (SRS), optimal selection of collimators from a set of fixed cones must be determined manually by trial and error. A unique and uniformly scaled metric to characterize plan quality could help identify Pareto-efficient treatment plans. METHODS: The concept of dose-area product (DAP) was used to define a measure (DAPratio) of the targeting efficiency of a set of beams by relating the integral DAP of the beams to the mean dose achieved in the target volume. In a retrospective study of five clinical cases of brain metastases with representative target volumes (range: 0.5-5.68 ml) and 121 treatment plans with all possible collimator choices, the DAPratio was determined along with other plan metrics (conformity index CI, gradient index R50%, treatment time, total number of monitor units TotalMU, radiotoxicity index f12, and energy efficiency index η50%), and the respective Spearman's rank correlation coefficients were calculated. The ability of DAPratio to determine Pareto efficiency for collimator selection at DAPratio < 1 and DAPratio < 0.9 was tested using scatter plots. RESULTS: The DAPratio for all plans was on average 0.95 ±â€¯0.13 (range: 0.61-1.31). Only the variance of the DAPratio was strongly dependent on the number of collimators. For each target, there was a strong or very strong correlation of DAPratio with all other metrics of plan quality. Only for R50% and η50% was there a moderate correlation with DAPratio for the plans of all targets combined, as R50% and η50% strongly depended on target size. Optimal treatment plans with CI, R50%, f12, and η50% close to 1 were clearly associated with DAPratio < 1, and plans with DAPratio < 0.9 were even superior, but at the cost of longer treatment times and higher total monitor units. CONCLUSIONS: The newly defined DAPratio has been demonstrated to be a metric that characterizes the target efficiency of a set of beams in robotic SRS in one single and uniformly scaled number. A DAPratio < 1 indicates Pareto efficiency. The trade-off between plan quality on the one hand and short treatment time or low total monitor units on the other hand is also represented by DAPratio.

4.
Neurosurg Rev ; 45(4): 2975-2982, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35554745

RESUMO

Directional deep brain stimulation (dDBS) provides multiple programming options. Knowledge of the spatial lead orientation is useful for time-efficient programming. Recent studies demonstrated deviations of up to 90° from the intended orientation angle. We examined the deviation of dDBS-lead orientation for leads from two different manufacturers using intraoperative stereotactic (STX) X-ray images. Intraoperative 2D-X-ray images were acquired after implantation of the first lead (TP1) and the second lead (TP2) enabling the estimation of the spatial position of the first lead at TP1 and TP2 and of changes of the orientation for a defined time period. Two investigators retrospectively estimated the orientation of the directional marker for 64 patients. The mean deviation from intended spatial orientation was 40.8° ± 46.1° for all examined leads. The spatial orientation of the first lead did not significantly change within a period of approximately 1 h. The degree of deviation did not differ significantly between two lead manufacturers but depended on the lead fixation technique. Our results showed deviations from the intended orientation angle immediately after the insertion of dDBS leads. The initial spatial orientation remained stable for approximately 1 h and was not caused by technical properties of the implanted lead. Hence, it was most probably the result of unintended mechanical torsion during insertion and/or fixation. Because precise determination of the lead orientation is mandatory for target-oriented dDBS programming, the use of additional imaging suitable for precise 3D visualization of lead contacts and/or the positioning marker is recommended.


Assuntos
Estimulação Encefálica Profunda , Imageamento Tridimensional , Estimulação Encefálica Profunda/métodos , Eletrodos Implantados , Humanos , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética , Radiografia , Estudos Retrospectivos , Raios X
5.
Front Neurorobot ; 16: 762317, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35515711

RESUMO

Background: The development of robotic systems has provided an alternative to frame-based stereotactic procedures. The aim of this experimental phantom study was to compare the mechanical accuracy of the Robotic Surgery Assistant (ROSA) and the Leksell stereotactic frame by reducing clinical and procedural factors to a minimum. Methods: To precisely compare mechanical accuracy, a stereotactic system was chosen as reference for both methods. A thin layer CT scan with an acrylic phantom fixed to the frame and a localizer enabling the software to recognize the coordinate system was performed. For each of the five phantom targets, two different trajectories were planned, resulting in 10 trajectories. A series of five repetitions was performed, each time based on a new CT scan. Hence, 50 trajectories were analyzed for each method. X-rays of the final cannula position were fused with the planning data. The coordinates of the target point and the endpoint of the robot- or frame-guided probe were visually determined using the robotic software. The target point error (TPE) was calculated applying the Euclidian distance. The depth deviation along the trajectory and the lateral deviation were separately calculated. Results: Robotics was significantly more accurate, with an arithmetic TPE mean of 0.53 mm (95% CI 0.41-0.55 mm) compared to 0.72 mm (95% CI 0.63-0.8 mm) in stereotaxy (p < 0.05). In robotics, the mean depth deviation along the trajectory was -0.22 mm (95% CI -0.25 to -0.14 mm). The mean lateral deviation was 0.43 mm (95% CI 0.32-0.49 mm). In frame-based stereotaxy, the mean depth deviation amounted to -0.20 mm (95% CI -0.26 to -0.14 mm), the mean lateral deviation to 0.65 mm (95% CI 0.55-0.74 mm). Conclusion: Both the robotic and frame-based approach proved accurate. The robotic procedure showed significantly higher accuracy. For both methods, procedural factors occurring during surgery might have a more relevant impact on overall accuracy.

6.
Neuromodulation ; 25(6): 877-887, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-33476474

RESUMO

OBJECTIVES: Open questions remain regarding the optimal target, or sweetspot, for deep brain stimulation (DBS) in, for example, Parkinson's disease. Previous studies introduced different methods of mapping DBS effects to determine sweetspots. While having a direct impact on surgical targeting and postoperative programming in DBS, these methods so far have not been compared. MATERIALS AND METHODS: This study investigated five previously published DBS mapping approaches regarding their potential to correctly identify a predefined target. Methods were investigated in silico in eight different use-case scenarios, which incorporated different types of clinical data, noise, and differences in underlying neuroanatomy. Dice coefficients were calculated to determine the overlap between identified sweetspots and the predefined target. Additionally, out-of-sample predictive capabilities were assessed using the amount of explained variance R2. RESULTS: The five investigated methods resulted in highly variable sweetspots. Methods based on voxel-wise statistics against average outcomes showed the best performance overall. While predictive capabilities were high, even in the best of cases Dice coefficients remained limited to values around 0.5, highlighting the overall limitations of sweetspot identification. CONCLUSIONS: This study highlights the strengths and limitations of current approaches to DBS sweetspot mapping. Those limitations need to be taken into account when considering the clinical implications. All future approaches should be investigated in silico before being applied to clinical data.


Assuntos
Estimulação Encefálica Profunda , Doença de Parkinson , Estimulação Encefálica Profunda/métodos , Humanos , Doença de Parkinson/terapia
7.
Strahlenther Onkol ; 198(5): 484-496, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-34888732

RESUMO

PURPOSE: In stereotactic radiosurgery (SRS), prescription isodoses and resulting dose homogeneities vary widely across different platforms and clinical entities. Our goal was to investigate the physical limitations of generating dose distributions with an intended level of homogeneity in robotic SRS. METHODS: Treatment plans for non-isocentric irradiation of 4 spherical phantom targets (volume 0.27-7.70 ml) and 4 clinical targets (volume 0.50-5.70 ml) were calculated using Sequential (phantom) or VOLOTM (clinical) optimizers (Accuray, Sunnyvale, CA, USA). Dose conformity, volume of 12 Gy isodose (V12Gy) as a measure for dose gradient, and treatment time were recorded for different prescribed isodose levels (PILs) and collimator settings. In addition, isocentric irradiation of phantom targets was examined, with dose homogeneity modified by using different collimator sizes. RESULTS: Dose conformity was generally high (nCI ≤ 1.25) and varied little with PIL. For all targets and collimator sets, V12Gy was highest for PIL ≥ 80% and lowest for PIL ≤ 65%. The impact of PIL on V12Gy was highest for isocentric irradiation and lowest for clinical targets (VOLOTM optimization). The variability of V12Gy as a function of collimator selection was significantly higher than that of PIL. V12Gy and treatment time were negatively correlated. Plans utilizing a single collimator with a diameter in the range of 70-80% of the target diameter were fastest, but showed the strongest dependence on PIL. CONCLUSION: Inhomogeneous dose distributions with PIL ≤ 70% can be used to minimize dose to normal tissue. PIL ≥ 90% is associated with a marked and significant increase in off-target dose exposure. Careful selection of collimators during planning is even more important.


Assuntos
Radiocirurgia , Procedimentos Cirúrgicos Robóticos , Humanos , Prescrições , Radiocirurgia/métodos , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos
8.
Radiother Oncol ; 166: 37-43, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34801629

RESUMO

BACKGROUND: Brain metastases show different patterns of contrast enhancement, potentially reflecting hypoxic and necrotic tumor regions with reduced radiosensitivity. An objective evaluation of these patterns might allow a prediction of response to radiotherapy. We therefore investigated the potential of MRI radiomics in comparison with the visual assessment of semantic features to predict early response to stereotactic radiosurgery in patients with brain metastases. PATIENTS AND METHODS: In this retrospective study, 150 patients with 308 brain metastases from solid tumors (NSCLC in 53% of patients) treated by stereotactic radiosurgery (single dose of 17-20 Gy) were evaluated. The response of each metastasis (partial or complete remission vs. stabilization or progression) was assessed within 180 days after radiosurgery. Patterns of contrast enhancement in the pre-treatment T1-weighted MR images were either visually classified (homogenous, heterogeneous, necrotic ring-like) or subjected to a radiomics analysis. Random forest models were optimized by cross-validation and evaluated in a hold-out test data set (30% of metastases). RESULTS: In total, 221/308 metastases (72%) responded to radiosurgery. The optimal radiomics model comprised 10 features and outperformed the model solely based on semantic features in the test data set (AUC, 0.71 vs. 0.56; accuracy, 69% vs. 54%). The diagnostic performance could be further improved by combining semantic and radiomics features resulting in an AUC of 0.74 and an accuracy of 75% in the test data set. CONCLUSION: The developed radiomics model allowed prediction of early response to radiosurgery in patients with brain metastases and outperformed the visual assessment of patterns of contrast enhancement.


Assuntos
Neoplasias Encefálicas , Neoplasias Pulmonares , Radiocirurgia , Neoplasias Encefálicas/diagnóstico por imagem , Neoplasias Encefálicas/radioterapia , Neoplasias Encefálicas/secundário , Humanos , Neoplasias Pulmonares/cirurgia , Imageamento por Ressonância Magnética/métodos , Radiocirurgia/métodos , Estudos Retrospectivos , Semântica
9.
Brain Sci ; 11(11)2021 Oct 31.
Artigo em Inglês | MEDLINE | ID: mdl-34827449

RESUMO

Directional deep brain stimulation (DBS) leads are now widely used, but the orientation of directional leads needs to be taken into account when relating DBS to neuroanatomy. Methods that can reliably and unambiguously determine the orientation of directional DBS leads are needed. In this study, we provide an enhanced algorithm that determines the orientation of directional DBS leads from postoperative CT scans. To resolve the ambiguity of symmetric CT artifacts, which in the past, limited the orientation detection to two possible solutions, we retrospectively evaluated four different methods in 150 Cartesia™ directional leads, for which the true solution was known from additional X-ray images. The method based on shifts of the center of mass (COM) of the directional marker compared to its expected geometric center correctly resolved the ambiguity in 100% of cases. In conclusion, the DiODe v2 algorithm provides an open-source, fully automated solution for determining the orientation of directional DBS leads.

10.
Radiat Oncol ; 16(1): 74, 2021 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-33863358

RESUMO

OBJECTIVES: To generate and validate state-of-the-art radiomics models for prediction of radiation-induced lung injury and oncologic outcome in non-small cell lung cancer (NSCLC) patients treated with robotic stereotactic body radiation therapy (SBRT). METHODS: Radiomics models were generated from the planning CT images of 110 patients with primary, inoperable stage I/IIa NSCLC who were treated with robotic SBRT using a risk-adapted fractionation scheme at the University Hospital Cologne (training cohort). In total, 199 uncorrelated radiomic features fulfilling the standards of the Image Biomarker Standardization Initiative (IBSI) were extracted from the outlined gross tumor volume (GTV). Regularized models (Coxnet and Gradient Boost) for the development of local lung fibrosis (LF), local tumor control (LC), disease-free survival (DFS) and overall survival (OS) were built from either clinical/ dosimetric variables, radiomics features or a combination thereof and validated in a comparable cohort of 71 patients treated by robotic SBRT at the Radiosurgery Center in Northern Germany (test cohort). RESULTS: Oncologic outcome did not differ significantly between the two cohorts (OS at 36 months 56% vs. 43%, p = 0.065; median DFS 25 months vs. 23 months, p = 0.43; LC at 36 months 90% vs. 93%, p = 0.197). Local lung fibrosis developed in 33% vs. 35% of the patients (p = 0.75), all events were observed within 36 months. In the training cohort, radiomics models were able to predict OS, DFS and LC (concordance index 0.77-0.99, p < 0.005), but failed to generalize to the test cohort. In opposite, models for the development of lung fibrosis could be generated from both clinical/dosimetric factors and radiomic features or combinations thereof, which were both predictive in the training set (concordance index 0.71- 0.79, p < 0.005) and in the test set (concordance index 0.59-0.66, p < 0.05). The best performing model included 4 clinical/dosimetric variables (GTV-Dmean, PTV-D95%, Lung-D1ml, age) and 7 radiomic features (concordance index 0.66, p < 0.03). CONCLUSION: Despite the obvious difficulties in generalizing predictive models for oncologic outcome and toxicity, this analysis shows that carefully designed radiomics models for prediction of local lung fibrosis after SBRT of early stage lung cancer perform well across different institutions.


Assuntos
Carcinoma Pulmonar de Células não Pequenas/radioterapia , Lesão Pulmonar/etiologia , Neoplasias Pulmonares/radioterapia , Lesões por Radiação/etiologia , Radiometria/métodos , Radiocirurgia/métodos , Idoso , Idoso de 80 Anos ou mais , Intervalo Livre de Doença , Fracionamento da Dose de Radiação , Feminino , Humanos , Estimativa de Kaplan-Meier , Aprendizado de Máquina , Masculino , Pessoa de Meia-Idade , Fibrose Pulmonar/etiologia , Estudos Retrospectivos , Robótica , Resultado do Tratamento
11.
J Cancer Res Clin Oncol ; 147(9): 2765-2773, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-33638006

RESUMO

PURPOSE: The introduction of hypofractionated stereotactic radiosurgery (hSRS) extended the treatment modalities beyond the well-established single-fraction stereotactic radiosurgery and fractionated radiotherapy. Here, we report the efficacy and side effects of hSRS using Cyberknife® (CK-hSRS) for the treatment of patients with critical brain metastases (BM) and a very poor prognosis. We discuss our experience in light of current literature. METHODS: All patients who underwent CK-hSRS over 3 years were retrospectively included. We applied a surface dose of 27 Gy in 3 fractions. Rates of local control (LC), systemic progression-free survival (PFS), and overall survival (OS) were estimated using Kaplan-Meier method. Treatment-related complications were rated using the Common Terminology Criteria for Adverse Events (CTCAE). RESULTS: We analyzed 34 patients with 75 BM. 53% of the patients had a large tumor, tumor location was eloquent in 32%, and deep seated in 15%. 36% of tumors were recurrent after previous irradiation. The median Karnofsky Performance Status was 65%. The actuarial rates of LC at 3, 6, and 12 months were 98%, 98%, and 78.6%, respectively. Three, 6, and 12 months PFS was 38%, 32%, and 15%, and OS was 65%, 47%, and 28%, respectively. Median OS was significantly associated with higher KPS, which was the only significant factor for survival. Complications CTCAE grade 1-3 were observed in 12%. CONCLUSION: Our radiation schedule showed a reasonable treatment effectiveness and tolerance. Representing an optimal salvage treatment for critical BM in patients with a very poor prognosis and clinical performance state, CK-hSRS may close the gap between surgery, stereotactic radiosurgery, conventional radiotherapy, and palliative care.


Assuntos
Neoplasias Encefálicas/cirurgia , Neoplasias/cirurgia , Radiocirurgia/mortalidade , Terapia de Salvação/mortalidade , Adulto , Idoso , Idoso de 80 Anos ou mais , Neoplasias Encefálicas/secundário , Feminino , Seguimentos , Humanos , Avaliação de Estado de Karnofsky , Masculino , Pessoa de Meia-Idade , Neoplasias/patologia , Hipofracionamento da Dose de Radiação , Estudos Retrospectivos , Taxa de Sobrevida , Resultado do Tratamento
12.
Radiat Oncol ; 16(1): 22, 2021 Jan 28.
Artigo em Inglês | MEDLINE | ID: mdl-33509211

RESUMO

BACKGROUND: For meningiomas, complete resection is recommended as first-line treatment while stereotactic radiosurgery (SRS) is established for meningiomas of smaller size considered inoperable. If the patient´s medical condition or preference excludes surgery, SRS remains a treatment option. We evaluated the efficacy and safety of SRS in a cohort comprising these cases. METHODS: In this retrospective single-centre analysis we included patients receiving single fraction SRS either by modified LINAC or robotic guidance by Cyberknife for potentially resectable intracranial meningiomas. Treatment-related adverse events as well as local and regional control rates were determined from follow-up imaging and estimated by the Kaplan-Meier method. RESULTS: We analyzed 188 patients with 218 meningiomas. The median radiological, and clinical follow-up periods were 51.4 (6.2-289.6) and 55.8 (6.2-300.9) months. The median tumor volume was 4.2 ml (0.1-22), and the mean marginal radiation dose was 13.0 ± 3.1 Gy, with reference to the 80.0 ± 11.2% isodose level. Local recurrence was observed in one case (0.5%) after 239 months. The estimated 2-, 5-, 10- and 15-year regional recurrence rates were 1.5%, 3.0%, 6.6% and 6.6%, respectively. Early adverse events (≤ 6 months after SRS) occurred in 11.2% (CTCEA grade 1-2) and resolved during follow-up in 7.4% of patients, while late adverse events were documented in 14.4% (grade 1-2; one case grade 3). Adverse effects (early and late) were associated with the presence of symptoms or neurological deficits prior to SRS (p < 0.03) and correlated with the treatment volume (p < 0.02). CONCLUSION: In this analysis SRS appears to be an effective treatment for patients with meningiomas eligible for complete resection and provides reliable long-term local tumor control with low rates of mild morbidity.


Assuntos
Neoplasias Meníngeas/cirurgia , Meningioma/cirurgia , Recidiva Local de Neoplasia/cirurgia , Radiocirurgia/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Seguimentos , Humanos , Masculino , Neoplasias Meníngeas/patologia , Meningioma/patologia , Pessoa de Meia-Idade , Recidiva Local de Neoplasia/patologia , Estudos Retrospectivos , Resultado do Tratamento , Adulto Jovem
13.
Stereotact Funct Neurosurg ; 99(1): 65-74, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33080600

RESUMO

BACKGROUND: Directional leads are increasingly used in deep brain stimulation. They allow shaping the electrical field in the axial plane. These new possibilities increase the complexity of programming. Thus, optimized programming approaches are needed to assist clinical testing and to obtain full clinical benefit. OBJECTIVES: This simulation study investigates to what extent the electrical field can be shaped by directional steering to compensate for lead malposition. METHOD: Binary volumes of tissue activated (VTA) were simulated, by using a finite element method approach, for different amplitude distributions on the three directional electrodes. VTAs were shifted from 0 to 2 mm at different shift angles with respect to the lead orientation, to determine the best compensation of a target volume. RESULTS: Malpositions of 1 mm can be compensated with the highest gain of overlap with directional leads. For larger shifts, an improvement of overlap of 10-30% is possible, depending on the stimulation amplitude and shift angle of the lead. Lead orientation and shift determine the amplitude distribution of the electrodes. CONCLUSION: To get full benefit from directional leads, both the shift angle as well as the shift to target volume are required to choose the correct amplitude distribution on the electrodes. Current directional leads have limitations when compensating malpositions >1 mm; however, they still outperform conventional leads in reducing overstimulation. Further, their main advantage probably lies in the reduction of side effects. Databases like the one from this simulation could serve for optimized lead programming algorithms in the future.


Assuntos
Algoritmos , Simulação por Computador , Estimulação Encefálica Profunda/métodos , Eletrodos Implantados , Análise de Elementos Finitos , Estimulação Encefálica Profunda/instrumentação , Humanos
14.
Stereotact Funct Neurosurg ; 99(2): 167-170, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33049735

RESUMO

BACKGROUND: Directional deep brain stimulation (DBS) enlarges the therapeutic window by increasing side-effect thresholds and improving clinical benefits. To determine the optimal stimulation settings and interpret clinical observations, knowledge of the lead orientation in relation to the patient's anatomy is required. OBJECTIVE: To determine if directional leads remain in a fixed orientation after implantation or whether orientation changes over time. METHOD: Clinical records of 187 patients with directional DBS electrodes were screened for CT scans in addition to the routine postoperative CT. The orientation angle of each electrode at a specific point in time was reconstructed from CT artifacts using the DiODe algorithm implemented in Lead-DBS. The orientation angles over time were compared with the originally measured orientations from the routine postoperative CT. RESULTS: Multiple CT scans were identified in 18 patients and the constancy of the orientation angle was determined for 29 leads at 48 points in time. The median time difference between the observations and the routine postoperative CT scan was 82 (range 1-811) days. The mean difference of the orientation angles compared to the initial measurement was -1.1 ± 3.9° (range -7.6 to 8.7°). Linear regression showed no relevant drift of the absolute value of the orientation angle over time (0.8°/year, adjusted R2: 0.040, p = 0.093). CONCLUSION: The orientation of directional leads was stable and showed no clinically relevant changes either in the first weeks after implantation or over longer periods of time.


Assuntos
Estimulação Encefálica Profunda , Algoritmos , Artefatos , Humanos , Tomografia Computadorizada por Raios X
15.
Radiat Oncol ; 15(1): 274, 2020 Dec 09.
Artigo em Inglês | MEDLINE | ID: mdl-33298109

RESUMO

BACKGROUND: Stereotactic radiosurgery (SRS) is widely accepted as a therapeutic option for meningiomas (M) and vestibular schwannomas (VS). However, data on outcome and toxicity in the elderly population have rarely been reported in detail. METHODS: All patients aged ≥ 65 years with M or VS who underwent single fraction SRS were included. Patient data were analyzed in terms of clinical tumor control and incidence of early and late treatment related complications, which were graded according to the Common Terminology Criteria for Adverse Events (CTCAE), RESULTS: We identified 245 patients with benign brain tumors (129 M and 116 VS, median tumor volume 2.9 ml, range 0.1-28). The median age was 71 years (range 65-86) and the mean follow-up times were 42 months (range 2-181). Tumors were irradiated with a median dose of 12.4 Gy. Actuarial clinical and radiological tumor control rates at 2, 5, and 10 years after SRS were 98%, 93%, and 88%, respectively. Recurrent tumors after previous treatment had a higher probability of post-radiosurgical progression (p < 0.001). Permanent toxicity (CTCAE I/II) were noted in 5.7%. No severe adverse events were observed during early and late follow up, although patients > 70 years had a slightly higher risk for toxicity (p = 0.027). The presence and extent of co-morbidities had no significant influence on local tumor control or toxicity. CONCLUSION: SRS provides favorable tumor control with low risk for treatment-related severe complications. Thus, SRS should always be considered as treatment option for benign intracranial tumors (meningiomas, schwannomas), especially in the group of elderly patients.


Assuntos
Neoplasias Encefálicas/radioterapia , Radiocirurgia/métodos , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Recidiva Local de Neoplasia , Radiocirurgia/efeitos adversos , Estudos Retrospectivos
16.
Strahlenther Onkol ; 196(10): 848-855, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32647917

RESUMO

Over the past years, the quantity and complexity of imaging data available for the clinical management of patients with solid tumors has increased substantially. Without the support of methods from the field of artificial intelligence (AI) and machine learning, a complete evaluation of the available image information is hardly feasible in clinical routine. Especially in radiotherapy planning, manual detection and segmentation of lesions is laborious, time consuming, and shows significant variability among observers. Here, AI already offers techniques to support radiation oncologists, whereby ultimately, the productivity and the quality are increased, potentially leading to an improved patient outcome. Besides detection and segmentation of lesions, AI allows the extraction of a vast number of quantitative imaging features from structural or functional imaging data that are typically not accessible by means of human perception. These features can be used alone or in combination with other clinical parameters to generate mathematical models that allow, for example, prediction of the response to radiotherapy. Within the large field of AI, radiomics is the subdiscipline that deals with the extraction of quantitative image features as well as the generation of predictive or prognostic mathematical models. This review gives an overview of the basics, methods, and limitations of radiomics, with a focus on patients with brain tumors treated by radiation therapy.


Assuntos
Inteligência Artificial , Neoplasias Encefálicas/diagnóstico por imagem , Biologia Computacional , Processamento de Imagem Assistida por Computador/métodos , Radioterapia (Especialidade)/métodos , Neoplasias Encefálicas/radioterapia , Conjuntos de Dados como Assunto , Aprendizado Profundo , Humanos , Imageamento Tridimensional , Neuroimagem , Radioterapia (Especialidade)/tendências , Planejamento da Radioterapia Assistida por Computador/métodos , Reprodutibilidade dos Testes , Fluxo de Trabalho
17.
Sci Rep ; 10(1): 9309, 2020 06 09.
Artigo em Inglês | MEDLINE | ID: mdl-32518238

RESUMO

Stereotactic radiosurgery (SRS) has evolved as widely accepted treatment option for small-sized (Koos I up to II) vestibular schwannoma (VS). For larger tumors (prevalent Koos VI), microsurgery or combined treatment strategies are mostly recommended. However, in patients not suited for microsurgery, SRS might also be an alternative to balance tumor control, hearing preservation and adverse effects. The purpose of this analysis was to evaluate the efficacy and toxicity of SRS for VS with regard to different Koos grades. All patients with untreated VS who received SRS at our center were included. Outcome analysis included tumor control, preservation of serviceable hearing based on median pure tone averages (PTA), and procedure-related adverse events rated by the Common Terminology Criteria for Adverse Events (CTCAE; v4.03) classification. In total, 258 patients (median age 58 years, range 21-84) were identified with a mean follow-up of 52 months (range 3-228 months). Mean tumor volume was 1.8 ml (range 0.1-18.5). The mean marginal dose was 12.3 Gy ± 0.6 (range 11-13.5). The cohort was divided into two groups: A (Koos grades I and II, n = 186) and B (Koos grades III and IV, n = 72). The actuarial tumor control rate was 98% after 2 years and 90% after 5 and 10 years. Koos grading did not show a significant impact on tumor control (p = 0.632) or hearing preservation (p = 0.231). After SRS, 18 patients (7%) had new transient or permanent symptoms classified by the CTCAE. The actuarial rate of CTCAE-free survival was not related to Koos grading (p = 0.093). Based on this selected population of Koos grade III and IV VS without or with only mild symptoms from brainstem compression, SRS can be recommended as the primary therapy with the advantage of low morbidity and satisfactory tumor control. The overall hearing preservation rate and toxicity of SRS was influenced by age and cannot be predicted by tumor volume or Koos grading alone.


Assuntos
Neuroma Acústico/radioterapia , Radiocirurgia/efeitos adversos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Audição/efeitos da radiação , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Neuroma Acústico/mortalidade , Neuroma Acústico/patologia , Dosagem Radioterapêutica , Estudos Retrospectivos , Resultado do Tratamento , Adulto Jovem
18.
Radiat Oncol ; 15(1): 87, 2020 Apr 20.
Artigo em Inglês | MEDLINE | ID: mdl-32312276

RESUMO

INTRODUCTION: Deep learning-based algorithms have demonstrated enormous performance in segmentation of medical images. We collected a dataset of multiparametric MRI and contour data acquired for use in radiosurgery, to evaluate the performance of deep convolutional neural networks (DCNN) in automatic segmentation of brain metastases (BM). METHODS: A conventional U-Net (cU-Net), a modified U-Net (moU-Net) and a U-Net trained only on BM smaller than 0.4 ml (sU-Net) were implemented. Performance was assessed on a separate test set employing sensitivity, specificity, average false positive rate (AFPR), the dice similarity coefficient (DSC), Bland-Altman analysis and the concordance correlation coefficient (CCC). RESULTS: A dataset of 509 patients (1223 BM) was split into a training set (469 pts) and a test set (40 pts). A combination of all trained networks was the most sensitive (0.82) while maintaining a specificity 0.83. The same model achieved a sensitivity of 0.97 and a specificity of 0.94 when considering only lesions larger than 0.06 ml (75% of all lesions). Type of primary cancer had no significant influence on the mean DSC per lesion (p = 0.60). Agreement between manually and automatically assessed tumor volumes as quantified by a CCC of 0.87 (95% CI, 0.77-0.93), was excellent. CONCLUSION: Using a dataset which properly captured the variation in imaging appearance observed in clinical practice, we were able to conclude that DCNNs reach clinically relevant performance for most lesions. Clinical applicability is currently limited by the size of the target lesion. Further studies should address if small targets are accurately represented in the test data.


Assuntos
Neoplasias Encefálicas/diagnóstico por imagem , Redes Neurais de Computação , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Neoplasias Encefálicas/radioterapia , Neoplasias Encefálicas/secundário , Aprendizado Profundo , Feminino , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Radiocirurgia , Planejamento da Radioterapia Assistida por Computador , Sensibilidade e Especificidade
19.
J Neurol Surg B Skull Base ; 81(2): 158-164, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-32206534

RESUMO

Objective Microsurgical resection of cavernous sinus meningiomas (CSM) is associated with a high rate of incomplete resection, recurrence, and the risk for permanent, severe cranial nerve deficits. Stereotactic radiosurgery (SRS) has evolved as alternative treatment for primary and recurrent CSM. Here, we report about the long-term clinical and radiological follow-up (FU) of a unique cohort of patients with CSM treated with LINAC or Cyberknife based SRS. Methods In this single-center retrospective analysis, we include all patients with CSM who underwent single fraction SRS between 1993 and 2016. Clinical and radiological tumor control were evaluated by the Kaplan-Meier method. Additionally, patient data were analyzed in terms of symptom control and incidence of side effects rated by the common terminology criteria for adverse events (CTCAE; v4.03). Results 116 patients (female/male = 91/25; median age, 54 years; range, 33-82 years) were included. Mean tumor volume was 5.7 ± 3.3 cm 3 (range, 0.6-16.2 cm 3 ), the median marginal dose was 12.6 Gy applied to isodose levels of 75%. Median clinical FU was 55 months (range, 3-226 months). Tumor control was 98% after 2 and 5 years and 90% after 10 years. Twelve patients (10.3%) had permanent or transient radiation related toxicity (CTCAE I-III). An improvement of symptoms was observed in 26.7% of the symptomatic patients ( n = 20 of 75). Conclusion SRS for CSM provides excellent long-term tumor and symptom control without considerable permanent side effects. Thus, SRS should be considered when counseling patients suffering from CSM.

20.
Strahlenther Onkol ; 195(9): 830-842, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-30874846

RESUMO

OBJECTIVES: To predict radiation-induced lung injury and outcome in non-small cell lung cancer (NSCLC) patients treated with robotic stereotactic body radiation therapy (SBRT) from radiomic features of the primary tumor. METHODS: In all, 110 patients with primary stage I/IIa NSCLC were analyzed for local control (LC), disease-free survival (DFS), overall survival (OS) and development of local lung injury up to fibrosis (LF). First-order (histogram), second-order (GLCM, Gray Level Co-occurrence Matrix) and shape-related radiomic features were determined from the unprocessed or filtered planning CT images of the gross tumor volume (GTV), subjected to LASSO (Least Absolute Shrinkage and Selection Operator) regularization and used to construct continuous and dichotomous risk scores for each endpoint. RESULTS: Continuous scores comprising 1-5 histogram or GLCM features had a significant (p = 0.0001-0.032) impact on all endpoints that was preserved in a multifactorial Cox regression analysis comprising additional clinical and dosimetric factors. At 36 months, LC did not differ between the dichotomous risk groups (93% vs. 85%, HR 0.892, 95%CI 0.222-3.590), while DFS (45% vs. 17%, p < 0.05, HR 0.457, 95%CI 0.240-0.868) and OS (80% vs. 37%, p < 0.001, HR 0.190, 95%CI 0.065-0.556) were significantly lower in the high-risk groups. Also, the frequency of LF differed significantly between the two risk groups (63% vs. 20% at 24 months, p < 0.001, HR 0.158, 95%CI 0.054-0.458). CONCLUSION: Radiomic analysis of the gross tumor volume may help to predict DFS and OS and the development of local lung fibrosis in early stage NSCLC patients treated with stereotactic radiotherapy.


Assuntos
Carcinoma Pulmonar de Células não Pequenas/radioterapia , Neoplasias Pulmonares/radioterapia , Pulmão/efeitos da radiação , Lesões por Radiação/etiologia , Radiocirurgia , Procedimentos Cirúrgicos Robóticos/métodos , Tomografia Computadorizada por Raios X , Idoso , Idoso de 80 Anos ou mais , Carcinoma Pulmonar de Células não Pequenas/patologia , Estudos de Coortes , Feminino , Humanos , Neoplasias Pulmonares/patologia , Masculino , Pessoa de Meia-Idade , Estadiamento de Neoplasias , Valor Preditivo dos Testes , Fibrose Pulmonar/etiologia , Planejamento da Radioterapia Assistida por Computador , Resultado do Tratamento , Carga Tumoral/efeitos da radiação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA