Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
J Neurosurg ; 134(3): 1072-1082, 2020 Mar 06.
Artigo em Inglês | MEDLINE | ID: mdl-32114534

RESUMO

OBJECTIVE: Deep brain stimulation (DBS) lead placement is increasingly performed with the patient under general anesthesia by surgeons using intraoperative MRI (iMRI) guidance without microelectrode recording (MER) or macrostimulation. The authors assessed the accuracy of lead placement, safety, and motor outcomes in patients with Parkinson disease (PD) undergoing DBS lead placement into the globus pallidus internus (GPi) using iMRI or MER guidance. METHODS: The authors identified all patients with PD who underwent either MER- or iMRI-guided GPi-DBS lead placement at Emory University between July 2007 and August 2016. Lead placement accuracy and adverse events were determined for all patients. Clinical outcomes were assessed using the Unified Parkinson's Disease Rating Scale (UPDRS) part III motor scores for patients completing 12 months of follow-up. The authors also assessed the levodopa-equivalent daily dose (LEDD) and stimulation parameters. RESULTS: Seventy-seven patients were identified (MER, n = 28; iMRI, n = 49), in whom 131 leads were placed. The stereotactic accuracy of the surgical procedure with respect to the planned lead location was 1.94 ± 0.21 mm (mean ± SEM) (95% CI 1.54-2.34) with frame-based MER and 0.84 ± 0.007 mm (95% CI 0.69-0.98) with iMRI. The rate of serious complications was similar, at 6.9% for MER-guided DBS lead placement and 9.4% for iMRI-guided DBS lead placement (RR 0.71 [95% CI 0.13%-3.9%]; p = 0.695). Fifty-seven patients were included in clinical outcome analyses (MER, n = 16; iMRI, n = 41). Both groups had similar characteristics at baseline, although patients undergoing MER-guided DBS had a lower response on their baseline levodopa challenge (44.8% ± 5.4% [95% CI 33.2%-56.4%] vs 61.6% ± 2.1% [95% CI 57.4%-65.8%]; t = 3.558, p = 0.001). Greater improvement was seen following iMRI-guided lead placement (43.2% ± 3.5% [95% CI 36.2%-50.3%]) versus MER-guided lead placement (25.5% ± 6.7% [95% CI 11.1%-39.8%]; F = 5.835, p = 0.019). When UPDRS III motor scores were assessed only in the contralateral hemibody (per-lead analyses), the improvements remained significantly different (37.1% ± 7.2% [95% CI 22.2%-51.9%] and 50.0% ± 3.5% [95% CI 43.1%-56.9%] for MER- and iMRI-guided DBS lead placement, respectively). Both groups exhibited similar reductions in LEDDs (21.2% and 20.9%, respectively; F = 0.221, p = 0.640). The locations of all active contacts and the 2D radial distance from these to consensus coordinates for GPi-DBS lead placement (x, ±20; y, +2; and z, -4) did not differ statistically by type of surgery. CONCLUSIONS: iMRI-guided GPi-DBS lead placement in PD patients was associated with significant improvement in clinical outcomes, comparable to those observed following MER-guided DBS lead placement. Furthermore, iMRI-guided DBS implantation produced a similar safety profile to that of the MER-guided procedure. As such, iMRI guidance is an alternative to MER guidance for patients undergoing GPi-DBS implantation for PD.


Assuntos
Estimulação Encefálica Profunda/métodos , Globo Pálido , Imageamento por Ressonância Magnética/métodos , Microeletrodos , Doença de Parkinson/terapia , Idoso , Antiparkinsonianos/uso terapêutico , Estimulação Encefálica Profunda/efeitos adversos , Eletrodos Implantados , Feminino , Humanos , Período Intraoperatório , Levodopa/uso terapêutico , Masculino , Pessoa de Meia-Idade , Doença de Parkinson/cirurgia , Complicações Pós-Operatórias/epidemiologia , Estudos Retrospectivos , Núcleo Subtalâmico/cirurgia , Tálamo/cirurgia , Resultado do Tratamento
2.
Parkinsonism Relat Disord ; 21(2): 116-9, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25465373

RESUMO

BACKGROUND: Several case reports and small series have indicated that tardive dystonia is responsive to globus pallidus deep brain stimulation. Whether different subtypes or distributions of tardive dystonia are associated with different outcomes remains unknown. METHODS: We assessed the outcomes and temporal profile of improvement of eight tardive dystonia patients who underwent globus pallidus deep brain stimulation over the past six years through record review. Due to the retrospective nature of this study, it was not blinded or placebo controlled. RESULTS: Consistent with previous studies, deep brain stimulation improved the overall the Burke-Fahn-Marsden motor scores by 85.1 ± 13.5%. The distributions with best responses in descending order were upper face, lower face, larynx/pharynx, limbs, trunk, and neck. Patients with prominent cervical dystonia demonstrated improvement in the Toronto Western Spasmodic Torticollis Rating Scale but improvements took several months. In four patients the effects of deep brain stimulation on improvement in Burke Fahn Marsden score was rapid, while in four cases there was partial rapid response of neck and trunk dystonia followed by was gradual resolution of residual symptoms over 48 months. CONCLUSION: Our retrospective analysis shows excellent resolution of tardive dystonia after globus pallidus deep brain stimulation. We found instantaneous response, except with neck and trunk dystonia where partial recovery was followed by further resolution at slower rate. Such outcome is encouraging for using deep brain stimulation in treatment of tardive dystonia.


Assuntos
Estimulação Encefálica Profunda/métodos , Globo Pálido/fisiologia , Transtornos dos Movimentos/diagnóstico , Transtornos dos Movimentos/terapia , Adulto , Estimulação Encefálica Profunda/tendências , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA