Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Eur Radiol ; 9(6): 1227-30, 1999.
Artigo em Inglês | MEDLINE | ID: mdl-10415267

RESUMO

We describe a case of graft-related pseudoaneurysm of the abdominal aorta evaluated with spiral CT and DSA. Spiral CT data sets were processed to obtain surface-rendered internal views (virtual angioscopy, VA) of the graft and the pseudoaneurysm, and to demonstrate from inside the lumen the site of dehiscence. A jet flow phenomenon inside the pseudoaneurysm was observed at DSA. Spiral-CT axial images, multiplanar volume reconstructions with maximum intensity projections, and shaded surface display showed the site of rupture. The VA findings were: (a) from inside the graft lumen, the evidence of a communication canal between the graft and the pseudoaneurysm; and (b) from inside the pseudoaneurysm, the presence of a jet flow. The VA findings showed good correlation with those obtained with the other imaging techniques.


Assuntos
Falso Aneurisma/diagnóstico por imagem , Angioscopia , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Falso Aneurisma/etiologia , Angiografia Digital , Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Deiscência da Ferida Operatória/diagnóstico por imagem , Interface Usuário-Computador
2.
Cardiovasc Intervent Radiol ; 22(1): 1-6, 1999 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-9929537

RESUMO

PURPOSE: To evaluate the diagnostic accuracy of virtual vascular endoscopy (VVE) in the detection of accessory renal arteries. METHODS: We retrospectively reviewed the CT angiography data sets of 67 patients (29 male and 38 female; age range 17-72 years, mean age 53 years) imaged for the study of the renal arteries, and affected by renovascular hypertension. All patients also had intraarterial digital subtraction angiography (DSA). CT angiography data sets were processed to obtain maximum intensity projection (MIP) and surface-rendered VVE of the aorta. Axial images, MIP, and VVE were evaluated separately and in combination in the detection of accessory renal arteries. Their results in terms of sensitivity and specificity were then compared with DSA. RESULTS: Axial images had a sensitivity of 88% and specificity of 94% for accessory renal artery detection, MIP had a sensitivity of 88% and specificity of 98%, and VVE had a sensitivity of 63% and a specificity of 88% (p < 0.05 vs DSA), but these increased to 88% and 98% respectively if endoscopic views were integrated with the other display techniques. CONCLUSION: VVE based on surface rendering does not add substantial benefits to CTY angiography; by contrast MIP is the most accurate display technique for the detection of accessory renal arteries.


Assuntos
Angioscopia/métodos , Aortografia/métodos , Circulação Colateral , Artéria Renal/diagnóstico por imagem , Adolescente , Adulto , Idoso , Feminino , Humanos , Hipertensão Renal/diagnóstico , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Intensificação de Imagem Radiográfica/métodos , Artéria Renal/patologia , Estudos Retrospectivos , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA