Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Diagnostics (Basel) ; 12(2)2022 Feb 18.
Artigo em Inglês | MEDLINE | ID: mdl-35204620

RESUMO

Carotid cavernous fistulas (CCFs) are abnormal connections between the cavernous sinus and the internal and/or external carotid artery. Endovascular therapy is the gold standard treatment. In the current retrospective single-center study we report detailed dosimetrics of all patients with CCFs treated by endovascular coil embolization between January 2012 and August 2021. Procedural and dosimetric data were compared between direct and indirect fistulas according to Barrow et al., and different DSA protocol groups. The local diagnostic reference level (DRL) was defined as the 3rd quartile of the dose distribution. In total, thirty patients met the study criteria. The local DRL was 376.2 Gy cm2. The procedural dose area product (DAP) (p = 0.03) and the number of implanted coils (p = 0.02) were significantly lower in direct fistulas. The median values for fluoroscopy time (FT) (p = 0.08) and number of DSA acquisitions (p = 0.84) were not significantly different between groups. There was a significantly positive correlation between DAP and FT (p = 0.003). The application of a dedicated low-dose protocol yielded a 32.6% DAP reduction. In conclusion, this study provides novel DRLs for endovascular CCF treatment using detachable coils. The data presented in this work might be used to establish new specific DRLs.

2.
Rofo ; 193(12): 1436-1444, 2021 Dec.
Artigo em Inglês, Alemão | MEDLINE | ID: mdl-34352914

RESUMO

PURPOSE: Since artificial intelligence is transitioning from an experimental stage to clinical implementation, the aim of our study was to evaluate the performance of a commercial, computer-aided detection algorithm of computed tomography pulmonary angiograms regarding the presence of pulmonary embolism in the emergency room. MATERIALS AND METHODS: This retrospective study includes all pulmonary computed tomography angiogram studies performed in a large emergency department over a period of 36 months that were analyzed by two radiologists experienced in emergency radiology to set a reference standard. Original reports and computer-aided detection results were compared regarding the detection of lobar, segmental, and subsegmental pulmonary embolism. All computer-aided detection findings were analyzed concerning the underlying pathology. False-positive findings were correlated to the contrast-to-noise ratio. RESULTS: Expert reading revealed pulmonary embolism in 182 of 1229 patients (49 % men, 10-97 years) with a total of 504 emboli. The computer-aided detection algorithm reported 3331 findings, including 258 (8 %) true-positive findings and 3073 (92 %) false-positive findings. Computer-aided detection analysis showed a sensitivity of 47 % (95 %CI: 33-61 %) on the lobar level and 50 % (95 %CI 43-56 %) on the subsegmental level. On average, there were 2.25 false-positive findings per study (median 2, range 0-25). There was no significant correlation between the number of false-positive findings and the contrast-to-noise ratio (Spearman's Rank Correlation Coefficient = 0.09). Soft tissue (61.0 %) and pulmonary veins (24.1 %) were the most common underlying reasons for false-positive findings. CONCLUSION: Applied to a population at a large emergency room, the tested commercial computer-aided detection algorithm faced relevant performance challenges that need to be addressed in future development projects. KEY POINTS: · Computed tomography pulmonary angiograms are frequently acquired in emergency radiology.. · Computer-aided detection algorithms (CADs) can support image analysis.. · CADs face challenges regarding false-positive and false-negative findings.. · Radiologists using CADs need to be aware of these limitations.. · Further software improvements are necessary ahead of implementation in the daily routine.. CITATION FORMAT: · Müller-Peltzer K, Kretzschmar L, Negrão de Figueiredo G et al. Present Limitations of Artificial Intelligence in the Emergency Setting - Performance Study of a Commercial, Computer-Aided Detection Algorithm for Pulmonary Embolism. Fortschr Röntgenstr 2021; 193: 1436 - 1444.


Assuntos
Inteligência Artificial , Embolia Pulmonar , Algoritmos , Computadores , Feminino , Humanos , Masculino , Embolia Pulmonar/diagnóstico por imagem , Interpretação de Imagem Radiográfica Assistida por Computador , Estudos Retrospectivos , Sensibilidade e Especificidade
3.
Rofo ; 192(2): 163-170, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31461762

RESUMO

PURPOSE: To observe the technical and clinical outcome as well as safety of CT fluoroscopy-guided drain placement in the multimodal clinical complication management of superinfected gastric leakage after sleeve gastrectomy. MATERIALS AND METHODS: All consecutive patients who underwent CT fluoroscopy-guided drain placement to treat superinfected postoperative leakage after sleeve gastrectomy in our department between 2007 and 2014 were included in this retrospective study. All interventions were performed on a 16- or 128-row CT scanner under intermittent CT fluoroscopy guidance (15-25 mAs, 120 kV). The technical and clinical success rates as well as complications, additional therapies and patient radiation dose were analyzed. RESULTS: 14 patients (mean age: 43.8 ±â€Š11.3 years, mean BMI: 52.9 ±â€Š13.5, 7 women) who underwent a total of 31 CT fluoroscopy-guided drain placement procedures were included. 30 of 31 interventions (96.8 %) were technically successful. 7 patients underwent more than one intervention due to drain obstruction or secondary dislocation or as further treatment. During and after the intervention no procedure-associated complications occurred. In all patients, inflammation parameters decreased within days after the CT-guided intervention. The total interventional dose length product (DLP) was 1561 ±â€Š1035 mGy*cm. CONCLUSION: CT fluoroscopy-guided drain placement has been shown to be a safe minimally invasive procedure that rarely leads to complications for treating superinfected gastric leakage occurring after sleeve gastrectomy. We assume that operative revisions in a high-risk patient group can be avoided using this procedure. KEY POINTS: · CT fluoroscopy-guided drain placement in obese - often medically highly complex - patients is a technically feasible procedure.. · Multimodal treatment (CT intervention, endoscopy and surgery) is required to successfully treat gastric leakage after bariatric surgery.. · High-risk surgery might be avoided by the CT-guided drain placement.. CITATION FORMAT: · Schwarz J, Strobl FF, Paprottka PM et al. CT Fluoroscopy-Guided Drain Placement to Treat Infected Gastric Leakage after Sleeve Gastrectomy: Technical and Clinical Outcome of 31 Procedures. Fortschr Röntgenstr 2020; 192: 163 - 170.


Assuntos
Fístula Anastomótica/cirurgia , Drenagem/métodos , Fluoroscopia/métodos , Gastrectomia , Cirurgia Assistida por Computador/métodos , Infecção da Ferida Cirúrgica/cirurgia , Tomografia Computadorizada por Raios X/métodos , Adulto , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
4.
Acta Radiol ; 58(8): 906-913, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-27856804

RESUMO

Background In unclear pancreatic lesions, a tissue sample can confirm or exclude the suspected diagnosis and help to provide an optimal treatment strategy to each patient. To date only one small study reported on the outcome of computed tomography (CT) fluoroscopy-guided biopsies of the pancreas. Purpose To evaluate technical success and diagnostic rate of all CT fluoroscopy-guided core biopsies of the pancreas performed in a single university center during a 10-year period. Material and Methods In this retrospective study we included all patients who underwent a CT fluoroscopy-guided biopsy of a pancreatic mass at our comprehensive cancer center between 2005 and 2014. All interventions were performed under local anesthesia on a 16-row or 128-row CT scanner. Technical success and diagnostic rates as well as complications and effective patient radiation dose were analyzed. Results One hundred and one patients (54 women; mean age, 63.9 ± 12.6 years) underwent a total of 104 CT fluoroscopy-guided biopsies of the pancreas. Ninety-eight of 104 interventions (94.2%) could be performed with technical success and at least one tissue sample could be obtained. In 88 of these 98 samples, a definitive pathological diagnosis, consistent with clinical success could be achieved (89.8%). Overall 19 minor and three major complications occurred during the intra- or 30-day post-interventional period and all other interventions could be performed without complications; there was no death attributable to the intervention. Conclusion CT fluoroscopy-guided biopsy of pancreatic lesions is an effective procedure characterized by a low major complication and a high diagnostic rate.


Assuntos
Biópsia Guiada por Imagem , Pancreatopatias/diagnóstico por imagem , Pancreatopatias/patologia , Tomografia Computadorizada por Raios X/métodos , Feminino , Fluoroscopia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
5.
Skeletal Radiol ; 42(1): 113-20, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-22422022

RESUMO

OBJECTIVE: To assess the technical results of CT fluoroscopy-guided, radiofrequency-induced vertebral augmentation (StabiliT®) in terms of vertebral height restoration and polymethylmethacrylate (PMMA) leakages, occurring in 25 individual patients with vertebral compression fractures and osteolysis. MATERIALS AND METHODS: From 07/2010 to 08/2011, 25 patients (16 women, nine men; age 71 ± 14; range 41-89) with painful vertebral compression fractures due to osteoporosis (n = 19), metastases (n = 2) or multiple myeloma (n = 4) underwent vertebral augmentation with a radiofrequency-activated, high-viscosity polymethylmethacrylate (PMMA) bone cement (StabiliT® Vertebral Augmentation system; DFINE Europe GmbH, Mannheim) under local anesthesia. Thirty-four vertebrae (Th5-L5) were treated in 27 sessions under CT fluoroscopy guidance (128-row CT, Somatom Definition AS, Siemens, Erlangen) using a unilateral access and a cavity-creating osteotome prior to remote-controlled, hydraulically driven cement injection. 1/2/3 levels were treated in 21/5/1 session(s). Vertebral height change in the midsagittal plane (anterior, midvertebral, posterior endplate distance) and PMMA leaks were retrospectively evaluated using the postinterventional CT. RESULTS: All patients were successfully treated in the first session. Mean (MV ± SD) procedure time and amount of injected PMMA were 56 ± 14 min and 4.5 ± 1.4 ml, respectively. Mean anterior/midvertebral/posterior height gain was +7.1/+9.7/+0.4%. Small local vertebral leaks were observed in 18/34 vertebrae (53%) without any clinical sequelae. No major complications occurred. CONCLUSIONS: CT fluoroscopy-guided, RF-induced vertebral augmentation with a high-viscosity bone cement (StabiliT®) was safe and technically successful in all patients. Using a hydraulic cement injection technique, a moderate restoration of anterior and midvertebral height was seen while the system was not markedly superior to standard vertebroplasty regarding the frequency of minor asymptomatic PMMA leaks.


Assuntos
Cimentos Ósseos/uso terapêutico , Fraturas por Compressão/tratamento farmacológico , Polimetil Metacrilato/uso terapêutico , Radiografia Intervencionista/métodos , Fraturas da Coluna Vertebral/tratamento farmacológico , Vertebroplastia/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Extravasamento de Materiais Terapêuticos e Diagnósticos , Feminino , Fluoroscopia , Fraturas por Compressão/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fraturas da Coluna Vertebral/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Resultado do Tratamento
6.
Cardiovasc Intervent Radiol ; 34 Suppl 2: S288-93, 2011 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-19795167

RESUMO

We present a case of combined surgical screw placement and osteoplasty guided by computed tomography-fluoroscopy (CTF) in a 68-year-old man with unilateral osteolytic destruction and a pathological fracture of the iliosacral joint due to a metastasis from renal cell carcinoma. The patient experienced intractable lower back pain that was refractory to analgesia. After transarterial particle and coil embolization of the tumor-feeding vessels in the angiography unit, the procedure was performed under general anesthesia by an interdisciplinary team of interventional radiologists and trauma surgeons. Under intermittent single-shot CTF, two K wires were inserted into the left iliosacral joint from a lateral transiliac approach at the S1 level followed by two self-tapping surgical screws. Continuous CTF was used for monitoring of the subsequent polymethylmethacrylate injection through two vertebroplasty cannulas for further stabilization of the screw threads within the osteolytic sacral ala. Both the screw placement and cement injection were successful, with no complications occurring during or after the procedure. With additional nonsteroidal anti-inflammatory and opioid medication, the patient reported a marked decrease in his lower back pain and was able to move independently again at the 3-month follow-up assessment. In our patient with intolerable back pain due to tumor destruction and consequent pathological fracture of the iliosacral joint, CTF-guided iliosacral screw placement combined with osteoplasty was successful with respect to joint stabilization and a reduction in the need for analgesic therapy.


Assuntos
Neoplasias Ósseas/secundário , Neoplasias Ósseas/cirurgia , Parafusos Ósseos , Carcinoma de Células Renais/secundário , Carcinoma de Células Renais/cirurgia , Fluoroscopia/métodos , Fixação Interna de Fraturas/métodos , Fraturas Espontâneas/cirurgia , Fraturas Intra-Articulares/cirurgia , Neoplasias Renais/cirurgia , Radiografia Intervencionista/métodos , Articulação Sacroilíaca/lesões , Articulação Sacroilíaca/cirurgia , Tomografia Computadorizada por Raios X/métodos , Idoso , Angiografia Digital , Cimentos Ósseos , Neoplasias Ósseas/diagnóstico , Carcinoma de Células Renais/diagnóstico , Terapia Combinada , Embolização Terapêutica , Fraturas Espontâneas/diagnóstico , Humanos , Fraturas Intra-Articulares/diagnóstico , Neoplasias Renais/diagnóstico , Masculino , Dor Intratável/cirurgia , Polimetil Metacrilato/administração & dosagem
7.
J Vasc Interv Radiol ; 19(11): 1596-606, 2008 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-18954766

RESUMO

PURPOSE: This retrospective study aimed to assess the results of computed tomographic (CT) fluoroscopy-guided percutaneous vertebroplasty (PV) of painful osteolytic spinal metastases from breast cancer, focusing on the frequency and clinical impact of polymethylmethacrylate (PMMA) leaks. MATERIALS AND METHODS: Within 48 months, 53 patients (52 women; mean age of 62 y +/- 13) with painful osteolytic breast cancer metastases underwent vertebroplasty. Eighty-six vertebrae were treated in 62 sessions under CT fluoroscopy guidance (single slice and four- and 16-row CT). In the planning CT scan, osteolytic destruction (ie, none, < or =25%, < or =50%, < or =75%, or < or =100%) was assessed regarding the vertebral cross-sectional area, the cortical border of the spinal canal, and the outer circumference. CT performed after vertebroplasty was used to detect local PMMA leaks (intradiscal, intraspinal, paravertebral, intercostovertebral/posterolateral, and vascular). Patient charts were reviewed with respect to adverse events. Clinical outcome was assessed on a visual analog scale (VAS) 24 hours before, immediately after, and 6 months after PV. RESULTS: Overall, 37.2%, 12.8%, and 1.2% of vertebrae (N = 86) showed at least a 50% osteolytic involvement of the cross-sectional area, spinal canal, and outer vertebral cortex, respectively. Intradiscal, intraspinal, paravertebral, and intercostovertebral/posterolateral leaks were seen in 31.3%, 26.9%, 26.9%, and 14.9% of vertebrae, respectively. The ratio of basivertebral to segmental venous leaks was 22.4%/23.9%. No major complications (eg, radiculopathy or pulmonary embolism) occurred. VAS scores decreased significantly (P < .05) from 6.4 at 24 hours before PV to 3.4 at a mean follow-up of 9.2 months. CONCLUSIONS: PV of osteolytic breast cancer metastases can be performed safely under CT fluoroscopic guidance even with substantial involvement of the vertebral cross-sectional area or cortical bone. A high clinical success rate was achieved and cortical and vascular PMMA leaks had no impact.


Assuntos
Neoplasias da Mama/terapia , Fluoroscopia/métodos , Radiografia Intervencionista/métodos , Neoplasias da Coluna Vertebral/secundário , Neoplasias da Coluna Vertebral/terapia , Tomografia Computadorizada por Raios X/métodos , Vertebroplastia/métodos , Feminino , Humanos , Pessoa de Meia-Idade , Cirurgia Assistida por Computador , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA