Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 33
Filtrar
2.
Clin Biochem ; 127-128: 110763, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38615787

RESUMO

OBJECTIVES: Contamination with intravenous (IV) fluids is a common cause of specimen rejection or erroneous results in hospitalized patients. Identification of contaminated samples can be difficult. Common measures such as failed delta checks may not be adequately sensitive nor specific. This study aimed to determine detection criteria using commonly ordered tests to identify IV fluid contamination and validate the use of these criteria. METHODS: Confirmed contaminated and non-contaminated samples were used to identify patterns in laboratory results to develop criteria to detect IV fluid contamination. The proposed criteria were implemented at a tertiary care hospital laboratory to assess performance prospectively for 6 months, and applied to retrospective chemistry results from 3 hospitals and 1 community lab to determine feasibility and flagging rates. The algorithm was also tested at an external institution for transferability. RESULTS: The proposed algorithm had a positive predictive value of 92 %, negative predictive value of 91 % and overall agreement of 92 % when two or more criteria are met (n = 214). The flagging rates were 0.03 % to 0.07 % for hospital and 0.003 % for community laboratories. CONCLUSIONS: The proposed algorithm identified true contamination with low false flagging rates in tertiary care urban hospital laboratories. Retrospective and prospective analysis suggest the algorithm is suitable for implementation in clinical laboratories to identify samples with possible IV fluid contamination for further investigation.


Assuntos
Algoritmos , Humanos , Estudos Retrospectivos , Laboratórios Clínicos , Estudos Prospectivos , Manejo de Espécimes/métodos , Manejo de Espécimes/normas
4.
Clin Chem ; 69(9): 991-1008, 2023 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-37478022

RESUMO

BACKGROUND: Harmonization in laboratory medicine is essential for consistent and accurate clinical decision-making. There is significant and unwarranted variation in reference intervals (RIs) used by laboratories for assays with established analytical traceability. The Canadian Society of Clinical Chemists (CSCC) Working Group on Reference Interval Harmonization (hRI-WG) aims to establish harmonized RIs (hRIs) for laboratory tests and support implementation. METHODS: Harnessing the power of big data, laboratory results were collected across populations and testing platforms to derive common adult RIs for 16 biochemical markers. A novel comprehensive approach was established, including: (a) analysis of big data from community laboratories across Canada; (b) statistical evaluation of age, sex, and analytical differences; (c) derivation of hRIs using the refineR method; and (d) verification of proposed hRIs across 9 laboratories with different instrumentation using serum and plasma samples collected from healthy Canadian adults. RESULTS: Harmonized RIs were calculated for all assays using the refineR method, except free thyroxine. Derived hRIs met proposed verification criterion across 9 laboratories and 5 manufacturers for alkaline phosphatase, albumin (bromocresol green), chloride, lactate dehydrogenase, magnesium, phosphate, potassium (serum), and total protein (serum). Further investigation is needed for some analytes due to failure to meet verification criteria in one or more laboratories (albumin [bromocresol purple], calcium, total carbon dioxide, total bilirubin, and sodium) or concern regarding excessively wide hRIs (alanine aminotransferase, creatinine, and thyroid stimulating hormone). CONCLUSIONS: We report a novel data-driven approach for RI harmonization. Findings support feasibility of RI harmonization for several analytes; however, some presented challenges, highlighting limitations that need to be considered in harmonization and big data analytics.


Assuntos
Ciência de Dados , Laboratórios , Adulto , Humanos , Valores de Referência , Canadá , Albuminas
6.
Clin Biochem ; 115: 103-106, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36220453

RESUMO

Appropriate specimen handling is integral to quality and minimizing medical errors. Clinical laboratories often rely on manufacturer's claims for handling specimens, such as sample stability conditions. Serum angiotensin converting enzyme (ACE) is an example in which manufacturer claims and stability in the literature is limited. The purpose of this study was to demonstrate the importance to verify manufacturer's stability using serum ACE as an example. Serum was collected from 39 healthy volunteers and ACE activity levels measured at baseline, after 4 h, 1, 3, 7 days at room temperature, after 3, 7, and 14 days refrigerated at 4 °C, after 1, 2, 4 and 8 weeks frozen at -20 °C, and after three freeze/thaw cycles. An additional 42 discarded patient serum specimens were re-analyzed after 1 or 2 weeks frozen at -20 °C. To evaluate stability performance, percent difference was compared to the clinical acceptance criteria, which was defined as a ½ total allowable error of ±10.9 %. This study found serum ACE to be stable 4 h at room temperature, 14 days refrigerated at 4 °C, up to 1 week frozen at -20 °C, and up to three freeze/thaw cycles. The preferred storage condition for serum ACE is refrigerated at 4 °C as there was minimal change in percent bias over the 14 day period. The false increase observed in samples stored frozen longer than 1 week could impact clinical decision making. The stability findings differed from manufacturer claims, highlighting the importance of verifying stability, especially for esoteric testing such as serum ACE where specimens travel long distances in varying climates to reach centralized testing locations.


Assuntos
Serviços de Laboratório Clínico , Peptidil Dipeptidase A , Humanos , Temperatura , Manejo de Espécimes , Laboratórios Clínicos
7.
CJC Open ; 5(12): 925-933, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38204856

RESUMO

Background: The objective of this study was to assess the introduction of a high-sensitivity troponin I (hs-TnI) assay and its associated accelerated protocol on emergency department (ED) length of stay (LOS) for patients presenting with chest pain, compared to an accelerated diagnostic protocol using conventional troponin (TnI) testing. Methods: We conducted a retrospective cohort study of all adults with a primary presenting complaint of chest pain of cardiac origin and a Canadian Triage and Acuity Scale score of 2 or 3, between November 8, 2019 and November 9, 2021, to a tertiary-care urban Canadian ED. The primary outcome was ED LOS. Secondary outcomes included consultation proportions and major adverse cardiac events within 30 days of the index ED visit. Results: A total of 2640 patients presenting with chest pain were included, with 1333 in the TnI group and 1307 in the hs-TnI group. Median ED LOS decreased significantly, from 392 minutes for the TnI group, and 371 minutes for the hs-TnI group (median difference = 21 minutes; 95% confidence interval: 5.3, 36.7). The numbers of consultations and admissions were not statistically different between study periods. The major adverse cardiac events outcomes did not change following the implementation of the hs-TnI test (13.6% vs 13.1%; P = 0.71). Conclusions: The implementation of an accelerated chest pain protocol using an hs-TnI assay in a tertiary-care Canadian ED was associated with a modest reduction of LOS for all patients, and a substantial reduction of LOS for patients undergoing serial troponin testing. This strategy was safe, with no increase in adverse outcomes.


Contexte: Cette étude visait à évaluer l'introduction du dosage de la troponine I de haute sensibilité (hs-TnI) et le protocole accéléré qui lui est associé sur la durée des séjours aux urgences dans le cas des patients qui consultent pour une douleur thoracique, comparativement à un protocole diagnostique accéléré faisant appel à un test de troponine classique (TnI). Méthodologie: Nous avons mené une étude de cohorte rétrospective portant sur tous les adultes qui se sont présentés aux urgences d'un établissement urbain de soins tertiaires canadien entre le 8 novembre 2019 et le 9 novembre 2021 principalement pour une douleur thoracique d'origine cardiaque et dont le score était de 2 ou 3 à l'Échelle canadienne de triage et de gravité (ETG). Le principal critère d'évaluation était la durée du séjour au service des urgences. Les critères d'évaluation secondaires comprenaient la fréquence des consultations et les événements cardiaques indésirables majeurs dans les 30 jours ayant suivi la visite de référence aux urgences. Résultats: Au total, 2640 patients qui s'étaient présentés aux urgences pour une douleur thoracique ont été inclus, 1333 se trouvant dans le groupe TnI et 1307 dans le groupe hs-TnI. La durée médiane du séjour aux urgences a diminué considérablement, passant de 392 minutes dans le groupe TnI à 371 minutes dans le groupe hs-TnI (différence médiane de 21 minutes; intervalle de confiance [IC] à 95 % : 5,3-36,7). Les consultations et les admissions n'ont pas affiché de différence statistique entre les périodes de l'étude. Les événements cardiaques indésirables majeurs n'ont pas varié après l'introduction du dosage de la hs-TnI (13,6 % vs 13,1 %; p = 0,71). Conclusions: L'adoption d'un protocole accéléré pour la douleur thoracique à l'aide du dosage de la hs-TnI au service des urgences d'un établissement de soins tertiaires canadien a été associée à une légère réduction de la durée du séjour pour l'ensemble des patients et à une réduction substantielle de cette durée pour les patients soumis à des analyses de la troponine en série. De plus, cette stratégie était sûre sans hausse des événements indésirables.

8.
Clin Biochem ; 97: 62-66, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34343576

RESUMO

OBJECTIVE: Reagent lot-to-lot comparisons are recommended by accreditation bodies to ensure that the performance of each reagent lot meets acceptable standards for quality patient results. The general approach is comprised of performing quality control (QC) and patient comparison between the old and new reagent lots and evaluating against a pre-defined criteria. Reagent lot comparison practices are often variable despite using the same instrument across different laboratories. This is costly, time consuming, and can lead to variability in acceptance criteria. While Clinical & Laboratory Standards Institute (CLSI) has a recommended guideline for reagent lot validation, it is often difficult to execute for small and rural laboratories due to limited resources. Defining the analytes required for detailed validation is important to allocate appropriate resources to ensure quality patient results. The goal of this study was to develop a standardized approach to reagent lot validation and optimize lab resources on Vitros chemistry instruments. DESIGN AND METHOD: This study consists of a retrospective and prospective analysis of reagent lot changes in dry slide chemistry analyzers (Ortho Clinical Diagnostics Vitros). Two years of retrospective reagent lot comparison data was obtained at a single site. A prospective study was conducted by assessing aliquots of 10 patient sample pools at 9 sites with Vitros analyzers. RESULTS: Of the 19 chemistry analytes evaluated, albumin, sodium, and total protein showed significant differences between reagent lots and also exceeded the pre-defined acceptance criteria. CONCLUSION: For these analytes, our recommendations are to perform a comprehensive lot validation with QC and patient samples. A simple lot validation with a reflex approach comprised of initially assaying QC can be adapted for the more stable analytes to allow achieving quality patient result in a resource constraint rural environment.


Assuntos
Química Clínica/instrumentação , Química Clínica/normas , Kit de Reagentes para Diagnóstico/normas , Equipamentos e Provisões , Humanos , Estudos Prospectivos , Controle de Qualidade , Reprodutibilidade dos Testes , Estudos Retrospectivos
9.
CJC Open ; 3(7): 981-983, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-34401704

RESUMO

A 78-year-old woman presented twice with high sensitivity troponin I (hs-TnI) elevation. Two cardiac catheterizations showed nonocclusive coronary artery disease, and 2 cardiac magnetic resonance imaging scans were normal. With these investigations unable to explain the troponin I (hs-TnI) elevation, alternate troponin samples were sent to check for assay interference. Results from these troponin assays were low. With the patient having elevated rheumatoid factor as a potential contributor to assay interference, the lab reanalyzed the samples using heterophile antibody blocking tubes, revealing lower hs-TnI levels. This case serves as a reminder to consider assay interference when the clinical picture is inconsistent with ischemia.


Une femme de 78 ans a eu deux fois une hausse de la troponine I à haute sensibilité (TnI hs). Deux cathétérismes cardiaques ont montré une coronaropathie non obstructive, et deux examens d'imagerie cardiaque par résonance magnétique se sont révélés normaux. Devant l'incapacité de ces examens à expliquer la hausse de la troponine I (TnI hs), d'autres échantillons de troponine ont été envoyés pour vérifier les interférences sur le dosage. Les résultats de ces dosages de la troponine étaient faibles. Puisque la présence d'un facteur rhumatoïde élevé chez la patiente a possiblement contribué à l'interférence du dosage, le laboratoire a soumis l'échantillon à une nouvelle analyse au moyen de tubes bloquant les anticorps hétérophiles. Cette dernière analyse a mis en évidence des concentrations plus faibles de TnI hs. Ce cas rappelle de tenir compte de l'interférence du dosage lorsque le tableau clinique n'est pas compatible avec l'ischémie.

11.
Clin Biochem ; 78: 25-31, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-31743687

RESUMO

OBJECTIVES: Previous analytical evaluations of the Beckman Coulter Access high sensitivity troponin (hsTn) I assay have focused on single platforms and laboratory sites. The purpose of this study was to determine assay robustness across different platforms at multiple sites, platform-specific characteristics, and equivalence to other hsTn methods in a large laboratory network. METHODS: Barricor plasma was used to assess imprecision, linearity, sensitivity (limit of blank and detection, LOB/LOD), and comparability to the conventional AccuTnI+3 and other hsTn assays. Various studies were conducted across a total of 9 laboratories using Beckman DxI800 and Access2 platforms. RESULTS: Within-laboratory precision was <10% across all target patient pool concentrations, however, DxI800 mean values were 20% higher than Access2 in the range of 3.6-44.9 ng/L. LOBs and LODs were lower on DxI800, 0.27 and 0.90 ng/L, respectively, compared to 2.9 and 3.2 ng/L, on Access2. Both showed excellent linearity across the full range. In method comparison to AccuTnI+3, DxI800 had a higher slope (0.9417 versus 0.8495) and positive bias (+18.1% versus -9.9%) compared to Access2, a trend further pronounced at concentrations <150 ng/L. At values <150 ng/L, there was good agreement with Abbott hsTnI (slope = 1.017, r = 0.932), but poor agreement with the Roche hsTnT assay (slope = 1.687, r = 0.589). Inter-laboratory split sample comparisons across 2 DxI800 and 7 Access2 sites showed close agreement, except at low concentrations <10 ng/L where DxI800 was 2.8 ng/L higher (p<0.001). CONCLUSIONS: The Beckman hsTnI assay showed robust analytical performance across different laboratories and platforms. However, discrepancies between platforms were found at low concentrations where rapid acute myocardial infarction (AMI) rule-out decisions occur. These differences have important implications for AMI risk assessment, suggesting that laboratories should develop platform-specific parameters rather than using them interchangibly.


Assuntos
Análise Química do Sangue/métodos , Troponina I/sangue , Biomarcadores/sangue , Feminino , Humanos , Limite de Detecção , Masculino , Sensibilidade e Especificidade
12.
J Appl Lab Med ; 3(5): 764-774, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-31639752

RESUMO

BACKGROUND: Cardiac troponin I (cTnI) 99th percentile cutoffs, used in the diagnosis of acute myocardial infarction, are not standardized across cTnI assays. We compared 3 point-of-care (POC) and 1 central laboratory contemporary cTnI assays against the Abbott high-sensitivity (hs) cTnI to evaluate the analytical concordance and the feasibility of using a single cutoff value for all assays. METHODS: Fresh blood samples collected from 102 inpatients in the coronary care unit were measured on central laboratory instruments (Beckman Coulter DxI AccuTnI+3 TnI, Abbott Architect hs-TnI) and cTnI POC analyzers (Alere Triage Troponin I, Radiometer AQT90, Abbott i-STAT). Agreement and correlation between the contemporary cTnI assays and hs-cTnI assay were assessed using regression analysis. Proportional bias was assessed using Bland-Altman plots. Concordance between the contemporary cTnI and hs-cTnI assays was determined by diagnostic contingency tables at specific cutoffs. RESULTS: Most POC cTnI assays had excellent correlation with the Abbott hs-cTnI method (r 2 = 0.955-0.970) except for Alere Triage (r 2 = 0.617), while proportional bias is evident between all cTnI assays. Overall concordance between POC contemporary cTnI assays and hs-cTnI assay was 80% to 90% at their respective 99th percentile cutoffs. The concordance increased to 90% to 95% when a fixed cutoff of 0.03 to 0.05 ng/mL was used across the assays. CONCLUSIONS: This study demonstrates poor analytical concordance between cTnI assays at the 99th percentile and supports the notion of a single clinical decision limit for cTnI and consequently standardization of diagnostic protocols despite the analytical differences among these assays.


Assuntos
Biomarcadores/sangue , Laboratórios/normas , Infarto do Miocárdio/sangue , Infarto do Miocárdio/diagnóstico , Sistemas Automatizados de Assistência Junto ao Leito/estatística & dados numéricos , Troponina I/sangue , Troponina T/sangue , Bioensaio , Feminino , Humanos , Masculino , Triagem/estatística & dados numéricos
14.
Can J Anaesth ; 65(8): 901-913, 2018 08.
Artigo em Inglês | MEDLINE | ID: mdl-29696581

RESUMO

PURPOSE: Hemodilutional anemia is associated with acute kidney injury (AKI) and mortality in patients undergoing cardiac surgery by mechanisms that may include tissue hypoxia. Our hypothesis was to assess if changes in the potential hypoxic biomarkers, including methemoglobin and erythropoietin, correlated with a decrease in hemoglobin (Hb) concentration following hemodilution on cardiopulmonary bypass (CPB). METHODS: Arterial blood samples were taken from patients (n = 64) undergoing heart surgery and CPB at baseline, during CPB, following CPB, and in the intensive care unit (ICU). Potential hypoxic biomarkers were measured, including methemoglobin, plasma Hb, and erythropoietin. Data were analyzed by repeated measures one-way analysis of variance on ranks and linear regression. RESULTS: Hemoglobin levels decreased following CPB and methemoglobin increased in the ICU (P < 0.001 for both). No correlation was observed between the change in Hb and methemoglobin (P = 0.23). By contrast, reduced Hb on CPB correlated with increased lactate, reduced pH, and increased erythropoietin levels following CPB (P ≤ 0.004 for all). Increased plasma Hb (P < 0.001) also correlated with plasma erythropoietin levels (P < 0.001). CONCLUSION: These data support the hypothesis that erythropoietin rather than methemoglobin is a potential biomarker of anemia-induced tissue hypoxia. The observed relationships between decreased Hb during CPB and the increase in lactate, reduced pH, and increase in erythropoietin levels suggest that early changes in plasma erythropoietin may be a pragmatic early biomarker of anemia-induced renal hypoxia. Further study is required to determine if anemia-induced increases in erythropoietin may predict AKI in patients undergoing cardiac surgery. TRIAL REGISTRATION: www.clinicaltrials.gov (NCT01883713). Registered 21 June 2013.


Assuntos
Injúria Renal Aguda/etiologia , Anemia/complicações , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Hemodiluição/efeitos adversos , Hipóxia/diagnóstico , Idoso , Biomarcadores/sangue , Ponte Cardiopulmonar/efeitos adversos , Eritropoetina/sangue , Feminino , Hemoglobinas/análise , Humanos , Masculino , Metemoglobina/análise , Pessoa de Meia-Idade , Estudos Prospectivos
15.
Clin Biochem ; 51: 80-84, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-28916438

RESUMO

BACKGROUND: Serum protein electrophoresis (SPE) and immunofixation electrophoresis (IFE) are used in the diagnosis and monitoring of plasma cell dyscrasias. IFE is considered the most sensitive method for the detection of monoclonal proteins (M-proteins), but it is not quantitative. The goal of this study was to establish the analytical sensitivity and diagnostic performance of SPE on the Sebia Hydrasys using HYDRAGEL 30 PROTEIN(E) ß1-ß2. METHODOLOGY: Patient sera with a previously identified M-protein (IgG, IgA or IgM) were serially diluted with a normal serum pool and electrophoresed on the Sebia Hydrasys using HYDRAGEL 30 PROTEIN(E) ß1-ß2. The SPE gels were individually interpreted by five independent observers and IFE was performed on selected samples. Limit of detection was determined as the lowest concentration of M-protein band visible on the gel. SPE diagnostic performance was evaluated against the "gold standard" IFE according CLSI EP12-A2 guidelines. RESULTS: Detection limit was comparable among all M-proteins migrating in the gamma region, IgG-κ (0.18±0.08g/L; n=6), IgG-λ (0.36±0.25g/L; n=8), IgA-κ (0.40±0.13g/L; n=7), IgA-λ (0.37±0.23g/L; n=4), IgM-κ (0.47±0.20g/L; n=13) and IgM-λ (0.29±0.24g/L; n=6). Percentage agreement with IFE for IgG and IgA in the gamma region ranged from 65% to 100%, whereas IgM migrating in the gamma region and immunoglobulins co-migrating with alpha or beta globulins, showed poor (0-38%) agreement. CONCLUSIONS: This study evaluates the analytical sensitivity and diagnostic performance of SPE on the Sebia Hydrasys using HYDRAGEL 30 PROTEIN(E) ß1-ß2. There was acceptable agreement between SPE and IFE for IgG-κ/λ and IgA-κ/λ migrating in the gamma region, suggesting that repeating IFE for samples with these isotypes, when the previous IFE and second SPE are both negative, may not be necessary.


Assuntos
Eletroforese das Proteínas Sanguíneas/instrumentação , Imunoglobulina A/sangue , Imunoglobulina G/sangue , Eletroforese das Proteínas Sanguíneas/normas , Humanos , Limite de Detecção , Paraproteinemias/sangue , Paraproteinemias/diagnóstico , Sensibilidade e Especificidade
18.
Intensive Care Med Exp ; 5(1): 12, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28251580

RESUMO

BACKGROUND: Low hemoglobin concentration (Hb) and low mean arterial blood pressure (MAP) impact outcomes in critically ill patients. We utilized an experimental model of "normotensive" vs. "hypotensive" acute hemodilutional anemia to test whether optimal tissue perfusion is dependent on both Hb and MAP during acute blood loss and fluid resuscitation, and to assess the value of direct measurements of the partial pressure of oxygen in tissue (PtO2). METHODS: Twenty-nine anesthetized rats underwent 40% isovolemic hemodilution (1:1) (or sham-hemodilution control, n = 4) with either hydroxyethyl starch (HES) (n = 14, normotensive anemia) or saline (n = 11, hypotensive anemia) to reach a target Hb value near 70 g/L. The partial pressure of oxygen in the brain and skeletal muscle tissue (PtO2) were measured by phosphorescence quenching of oxygen using G4 Oxyphor. Mean arterial pressure (MAP), heart rate, temperature, arterial and venous co-oximetry, blood gases, and lactate were assessed at baseline and for 60 min after hemodilution. Cardiac output (CO) was measured at baseline and immediately after hemodilution. Data were analyzed by repeated measures two-way ANOVA. RESULTS: Following "normotensive" hemodilution with HES, Hb was reduced to 66 ± 6 g/L, CO increased (p < 0.05), and MAP was maintained. These conditions resulted in a reduction in brain PtO2 (22.1 ± 5.6 mmHg to 17.5 ± 4.4 mmHg, p < 0.05), unchanged muscle PO2, and an increase in venous oxygen extraction. Following "hypotensive" hemodilution with saline, Hb was reduced to 79 ± 5 g/L and both CO and MAP were decreased (P < 0.05). These conditions resulted in a more severe reduction in brain PtO2 (23.2 ± 8.2 to 10.7 ± 3.6 mmHg (p < 0.05), a reduction in muscle PtO2 (44.5 ± 11.0 to 19.9 ± 12.4 mmHg, p < 0.05), a further increase in venous oxygen extraction, and a threefold increase in systemic lactate levels (p < 0.05). CONCLUSIONS: Acute normotensive anemia (HES hemodilution) was associated with a subtle decrease in brain tissue PtO2 without clear evidence of global tissue hypoperfusion. By contrast, acute hypotensive anemia (saline hemodilution) resulted in a profound decrease in both brain and muscle tissue PtO2 and evidence of inadequate global perfusion (lactic acidosis). These data emphasize the importance of maintaining CO and MAP to ensure adequacy of vital organ oxygen delivery during acute anemia. Improved methods of assessing PtO2 may provide an earlier warning signal of vital organ hypoperfusion.

19.
Can J Anaesth ; 62(11): 1179-87, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26335903

RESUMO

PURPOSE: Tranexamic acid (TXA) therapy can reduce red blood cell (RBC) transfusion; however, this therapy remains underutilized in many surgical patient populations. We assessed whether implementation of a protocol to facilitate universal administration of TXA in patients undergoing total hip or knee arthroplasty would reduce the incidence of RBC transfusion without increasing adverse clinical outcomes. METHODS: We implemented a quality of care policy to provide universal administration of intravenous TXA at a dose of 20 mg·kg(-1) iv to all eligible patients undergoing total hip or knee arthroplasty from October 21, 2013 to April 30, 2014. We compared data from an equal number of patients before and after protocol implementation (n = 422 per group). The primary outcome was RBC transfusion with secondary outcomes including postoperative hemoglobin concentration (Hb) and length of hospital stay. Adverse events were identified from the electronic medical records. Data were analyzed by a Chi square test and adjusted logistic and linear regression analysis. RESULTS: Implementation of the protocol resulted in an increase in TXA utilization from 45.8% to 95.3% [change 49.5%; 95% confidence interval (CI), 44.1 to 54.5; P < 0.001]. This change was associated with a reduction in the rate of RBC transfusion from 8.8% to 5.2%, (change -3.6%; 95% CI, -0.1 to -7.0; P = 0.043). Pre- and post-protocol mean [standard deviation (SD)] Hb values were similar, including the nadir Hb prior to RBC transfusion [72 (8) g·L(-1) vs 70 (8) g·L(-1), respectively; mean difference -1 g·L(-1); 95% CI, -3 to 5; P = 0.569]. Length of stay was not altered, and no increase in adverse events was observed. CONCLUSIONS: Implementation of a perioperative TXA protocol was associated with both an increase in TXA use and a reduction in RBC transfusion following hip or knee arthroplasty. Adverse events and length of hospital stay were not influenced by the protocol.


Assuntos
Antifibrinolíticos/uso terapêutico , Artroplastia de Quadril , Artroplastia do Joelho , Transfusão de Sangue/estatística & dados numéricos , Ácido Tranexâmico/uso terapêutico , Idoso , Perda Sanguínea Cirúrgica/prevenção & controle , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
20.
Vitam Horm ; 96: 161-92, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25189387

RESUMO

Nitric oxide (NO) production is catalyzed by three distinct enzymes, namely, neuronal nitric oxide synthase (nNOS), inducible NOS (iNOS), and endothelial NOS (eNOS). The production of NO by vascular endothelium relies mainly on eNOS. Curiously, iNOS and nNOS also are relevant for vascular NO production in certain settings. By relaxing vascular smooth muscle, the classical view is that NO participates in O2 homeostasis by increasing local blood flow and O2 delivery. It is now appreciated that NO has an even more fundamental role in cellular oxygen sensing at the cellular and physiological level. A key component of cellular oxygen sensing is the hypoxia-inducible factor (HIF) that activates a transcriptional program to promote cellular survival under conditions of inadequate oxygen supply. Important new insights demonstrate that HIF protein is stabilized by two parallel pathways: (1) a decrease in the O2-dependent prolyl hydroxylation of HIF and (2) NO-dependent S-nitrosylation of HIF pathway components including HIF-α. The need for these two complementary pathways to HIF activation arises because decreased oxygen delivery can occur not only by decreased ambient oxygen but also by decreased blood oxygen-carrying capacity, as with anemia. In turn, NO production is tightly linked to O2 homeostasis. O2 is a key substrate for the generation of NO and impacts the enzymatic activity and expression of the enzymes that catalyze the production of NO, the nitric oxide synthases. These relationships manifest in a variety of clinical settings ranging from the unique situation of humans living in hypoxic environments at high altitudes to the common scenario of anemia and the use of therapeutics that can bind or release NO.


Assuntos
Hipóxia/metabolismo , Óxido Nítrico/metabolismo , Transdução de Sinais/fisiologia , Animais , Humanos , Hipóxia/genética , Consumo de Oxigênio
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA