Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
2.
J Fr Ophtalmol ; 26(6): 622-5, 2003 Jun.
Artigo em Francês | MEDLINE | ID: mdl-12910204

RESUMO

We report the case of a 35-year-old Asian woman presenting with bilateral anterior uveitis with hypopyon associated with high intraocular pressure. In her past history, she described intermittent angle-closure episodes. Anterior chamber examination and ultrasound biomicroscopy revealed a creeping angle-closure glaucoma. This clinical entity can affect Asians. The angle is gradually shortened with an iris bombé that brings the peripheral iris close to the external angle wall. The acute episodes are often poorly symptomatic. An early diagnosis may prevent glaucoma damages.


Assuntos
Glaucoma de Ângulo Fechado/diagnóstico , Uveíte Anterior/etiologia , Adulto , Ásia/etnologia , Feminino , Lateralidade Funcional , Glaucoma de Ângulo Fechado/terapia , Humanos , Pressão Intraocular , Paris
3.
J Fr Ophtalmol ; 24(10): 1060-6, 2001 Dec.
Artigo em Francês | MEDLINE | ID: mdl-11913236

RESUMO

PURPOSE: One of cataract surgery's current imperatives involves refraction: the power of the lens implant must be calculated as accurately as possible. Here we present a new method of biometric ocular measurement using the partial optical consistency interferometer. MATERIAL AND METHODS: This investigation studied the axial length measurement of 100 eyes. Five measurements were taken with a classic echobiometric contact technique using the ultrasonic mode; 5 others were taken with the infrared noncontact technique (IOL Master, Zeiss Humphrey). The latter technique is based on interferometric biometry with optical consistency and measurements were taken with an infrared luminous ray. With extreme rapidity and no contact, the device provides a complete biometry, including axial length, keratometry, and anterior chamber depth. It includes a built-in computer. RESULTS: Comparing the ultrasonic and infrared measurements emphasizes the precision and particularly the high reproducibility of the infrared method. The standard deviations of the samples were significantly lower for the 100 measurements. Its limitations depends on the type of cataract since success was not obtained for certain posterior subcapsular opacities. DISCUSSION: This new method of performing a biometry with a partial consistency interferometer contributes a number of advantages: speed, its noninvasive nature with no contact, the high reproducibility of the exam, as well as precise measurements as shown by the difference in the standard deviations of the two methods. CONCLUSION: Biometry using the optical consistency interferometer seems to be a reliable, reproducible, and precise technique that brings great precision for the calculation of the power of the intraocular implant in cataract surgery.


Assuntos
Técnicas de Diagnóstico Oftalmológico/instrumentação , Lentes Intraoculares , Humanos , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA