Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Artigo em Inglês | MEDLINE | ID: mdl-38805871

RESUMO

Rivastigmine hydrogen tartrate (RHT), a reversible cholinesterase inhibitor, is considered as the first-line therapy for mild to moderate Alzheimer's disease. Asiaticoside (AS), a pentacyclic triterpenoid saponin, is well known as cognitive enhancer due to its antioxidant effect. Based on the hypothesis of their synergistic therapeutic potential, RHT and AS were co-encapsulated in niosomal formulation. A simple, precise, and accurate high-performance liquid chromatography method was developed for simultaneous quantitative analysis. The chromatographic parameters were optimized by Box-Behnken experimental design. The separation was performed on a reversed-phase Phenomenex C18 (150 mm × 4.6 mm, 5 µm) column at 30 °C under the UV detection of 210 nm. The optimized mobile phase consisted of a mixture of 20 mM potassium dihydrogen phosphate buffer (pH 2.6) and acetonitrile (72:28 % v/v) under the isocratic mode at the flow rate of 0.9 mL/min. The developed method was fully validated under the ICH guidelines and could be successfully applied for simultaneous quantitative analysis of RHT and AS in niosomal formulation.


Assuntos
Limite de Detecção , Lipossomos , Rivastigmina , Triterpenos , Cromatografia Líquida de Alta Pressão/métodos , Triterpenos/análise , Triterpenos/química , Lipossomos/química , Reprodutibilidade dos Testes , Rivastigmina/análise , Rivastigmina/química , Modelos Lineares
2.
Pharmaceutics ; 15(12)2023 Nov 28.
Artigo em Inglês | MEDLINE | ID: mdl-38140030

RESUMO

Celecoxib (CCB), a cyclooxygenase-2 inhibitor, is capable of reducing oxidative stress and vascular endothelial growth factor (VEGF) expression in retinal cells and has been shown to be effective in the treatment of diabetic retinopathy and age-related macular degeneration. However, the ocular bioavailability of CCB is hampered due to its very low aqueous solubility. In a previous study, we developed 0.5% (w/v) aqueous CCB eye drop microsuspensions (MS) containing randomly methylated ß-cyclodextrin (RMßCD) or γ-cyclodextrin (γCD) and hyaluronic acid (HA) as ternary CCB/CD/HA nanoaggregates. Both formulations exhibited good physicochemical properties. Therefore, we further investigated their cytotoxicity and efficacy in a human retina cell line in this study. At a CCB concentration of 1000 µg/mL, both CCB/RMßCD and CCB/γCD eye drop MS showed low hemolysis activity (11.1 ± 0.3% or 4.9 ± 0.2%, respectively). They revealed no signs of causing irritation and were nontoxic to retinal pigment epithelial cells. Moreover, the CCB eye drop MS exhibited significant anti-VEGF activity by reducing VEGF mRNA and protein levels compared to CCB suspended in phosphate buffer saline. The ex vivo transscleral diffusion demonstrated that a high quantity of CCB (112.47 ± 37.27 µg/mL) from CCB/γCD eye drop MS was deposited in the porcine sclera. Our new findings suggest that CCB/CD eye drop MS could be safely delivered to the ocular tissues and demonstrate promising eye drop formulations for retinal disease treatment.

3.
Am J Clin Pathol ; 120(1): 34-9, 2003 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-12866370

RESUMO

We compared 1-stage clot-based, chromogenic, and immunoassay methods for measuring factor VIII in plasma with a focus on the measurement of elevated levels of factor VIII. The chromogenic assay showed the best interassay imprecision for factor VIII levels near 150 IU/dL. The best correlation was between the 1-stage clot-based and chromogenic factor VIII assays (r2 = 0.934), and the lowest correlation was between the 1-stage clot-based and antigenic factor VIII assays (r2 = 0.821). The presence of heparin, low-molecular-weight heparin, lepirudin, or lupus inhibitors in the sample resulted in major interference in the 1-stage clot-based assay but not the chromogenic or antigenic factor VIII assays. Overall, the chromogenic factor VIII activity assay was the optimal method, showing good precision, the best overall correlation with other assays, and no interference from heparin, low-molecular-weight heparin, lepirudin, or lupus inhibitors.


Assuntos
Testes de Coagulação Sanguínea/métodos , Fator VII/análise , Coagulação Sanguínea/fisiologia , Compostos Cromogênicos/análise , Fator VII/imunologia , Humanos , Imunoensaio , Kit de Reagentes para Diagnóstico , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA