Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 81
Filtrar
1.
Cardiovasc Revasc Med ; 45: 9-14, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-35918254

RESUMO

Despite successful primary percutaneous coronary intervention (PCI) for treatment of ST-segment elevation myocardial infarction (STEMI), myocardial salvage is frequently suboptimal resulting in large infarctions with increased rates of heart failure and death. Microvascular dysfunction after the procedure is frequently present and contributes directly to poor outcomes in STEMI. Pressure-controlled intermittent Coronary Sinus Occlusion (PiCSO) is a novel technology designed to mitigate microvascular dysfunction in STEMI. Non-randomized studies have suggested that PiCSO use during primary PCI in STEMI is safe, improves microvascular perfusion and reduces infarct size. Randomized trials are ongoing to investigate the safety and effectiveness of PiCSO in high-risk patients with anterior STEMI undergoing primary PCI.


Assuntos
Seio Coronário , Intervenção Coronária Percutânea , Humanos , Seio Coronário/diagnóstico por imagem , Intervenção Coronária Percutânea/efeitos adversos
3.
BMC Gastroenterol ; 22(1): 151, 2022 Mar 28.
Artigo em Inglês | MEDLINE | ID: mdl-35346070

RESUMO

BACKGROUND: Selective internal radiation therapy (SIRT) with yttrium-90 (90Y) resin microspheres is an established locoregional treatment option for unresectable hepatocellular carcinoma (HCC), which delivers a lethal dose of radiation to hepatic tumors, while sparing surrounding healthy tissue. DOORwaY90 is a prospective, multicenter, open-label, single arm study, designed to evaluate the safety and effectiveness of 90Y resin microspheres as first-line treatment in patients with unresectable/unablatable HCC. It is unique in that it is the first study with resin microspheres to utilize a personalized 90Y dosimetry approach, and independent review for treatment planning and response assessment. METHODS: Eligibility criteria include unresectable/unablatable HCC, Barcelona Clinic Liver Cancer stage A, B1, B2, or C with a maximal single tumor diameter of ≤ 8 cm, and a sum of maximal tumor diameters of ≤ 12 cm, and at least one tumor ≥ 2 cm (long axis) per localized, modified Response Evaluation Criteria in Solid Tumors. Partition model dosimetry is used to determine the optimal dose; the target mean dose to tumor is ≥ 150 Gy. Patients are assessed at baseline and at regular intervals up until 12 months of treatment for response rates, safety, and quality of life (QoL). Post-treatment dosimetry is used to assess dose delivered to tumor and consider if retreatment is necessary. The co-primary endpoints are best objective response rate and duration of response. Secondary endpoints include grade ≥ 3 toxicity, QoL, and incidence of liver resection and transplantation post SIRT. Target recruitment is 100 patients. DISCUSSION: The results of this trial should provide further information on the potential use of SIRT with 90Y resin microspheres as first-line therapy for unresectable HCC. TRIAL REGISTRATION: Clinicaltrials.gov; NCT04736121; date of 1st registration, January 27, 2021, https://clinicaltrials.gov/ct2/show/NCT04736121 .


Assuntos
Carcinoma Hepatocelular , Neoplasias Hepáticas , Carcinoma Hepatocelular/patologia , Ensaios Clínicos como Assunto , Humanos , Neoplasias Hepáticas/patologia , Microesferas , Estudos Prospectivos , Qualidade de Vida
4.
Catheter Cardiovasc Interv ; 90(4): 639-646, 2017 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-28795488

RESUMO

OBJECTIVES: To propose a classification system for characterizing angiographic femoropopliteal artery restenosis patterns associated with common endovascular modalities. BACKGROUND: Peripheral artery disease is a worldwide issue affecting millions of people. Despite a myriad of endovascular technologies available to treat peripheral artery disease of the femoropopliteal arteries, restenosis remains a common failure mode. Characterizing common patterns of restenosis is important to discern the potential impact of baseline patient, lesion, and procedural characteristics, as well as treatment modalities on either the primary success or the failure patterns associated with restenosis. METHODS: Studies included in the analysis were from previous core laboratory-adjudicated femoropopliteal artery disease trials and registries reflecting a wide array of treatment modalities. RESULTS: From the subjects enrolled and analyzed, there were 403 total angiograms for analysis and adjudication. Target lesion revascularization images of the 32 validation cases were evaluated for index treated length, diameter stenosis, and lesion morphology characteristics. The following lesion types are proposed: Type 1 "Focal" pattern, which may be "Edge Proximal" or "Edge Distal" depending on location; a Type 2 "Multifocal" pattern which may also exhibit edge restenosis, but may also be "Edge Bilateral"; a Type 3 "Moderate" pattern and a Type 4 "Diffuse" pattern; and finally, a Type 5 "Occlusion". CONCLUSIONS: A classification system that enables healthcare professionals to anticipate and describe failures following the index procedure, thereby impacting the choice of options for retreatment, may facilitate consistency and standardization within the heterogeneous field of endovascular device treatments for the femoropopliteal artery.


Assuntos
Angiografia/métodos , Procedimentos Endovasculares/efeitos adversos , Artéria Femoral/diagnóstico por imagem , Doença Arterial Periférica/diagnóstico por imagem , Doença Arterial Periférica/terapia , Artéria Poplítea/diagnóstico por imagem , Consenso , Constrição Patológica , Humanos , Doença Arterial Periférica/classificação , Valor Preditivo dos Testes , Recidiva , Índice de Gravidade de Doença , Terminologia como Assunto , Resultado do Tratamento
5.
Coron Artery Dis ; 25(7): 575-81, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-24911615

RESUMO

OBJECTIVE: To investigate the difference in neointimal hyperplasia (NIH) between ST-segment elevation myocardial infarction (STEMI), stable angina pectoris (SAP), and unstable angina pectoris (UAP). PATIENTS AND METHODS: From formal core laboratory intravascular ultrasound substudies, we compared NIH after paclitaxel-eluting stents (PES) or bare metal stents (BMS) in STEMI lesions from HORIZONS-AMI trial with SAP and UAP lesions from TAXUS IV, V, and ATLAS studies. RESULTS: At follow-up, %NIH at the minimum lumen area (MLA) site was less in STEMI (n=212) than in UAP (n=233) and SAP (n=440) lesions treated with PES (19.6 vs. 26.2 vs. 25.0%, P=0.002; all intravascular ultrasound data shown as least-square means in abstract) and less in STEMI (n=66) than in UAP (n=72) and SAP (n=143) lesions treated with BMS (34.0 vs. 26.7 vs. 45.5%, P=0.0003). As a result, MLA at follow-up was larger in STEMI than in UAP and SAP lesions treated with PES (5.9 vs. 5.2 vs. 5.0 mm, P<0.0001) or treated with BMS (5.1 vs. 4.3 vs. 4.0 mm, P=0.002). Net volume obstruction ([NIH/stent volume]×100) at follow-up was significantly less in STEMI than in UAP and SAP lesions treated with PES (7.8 vs. 13.4 vs. 13.4%, P<0.0001) or BMS (20.6 vs. 28.5 vs. 32.1%, P<0.0001). Multivariate linear regression analysis showed that STEMI was correlated independently and inversely with net volume obstruction compared with SAP (regression coefficient -6.99, P<0.0001) or UAP (regression coefficient -6.29, P<0.0001). CONCLUSION: Implantation of PES or BMS in STEMI compared with UAP and SAP was associated with less NIH.


Assuntos
Angina Estável/terapia , Angina Instável/terapia , Vasos Coronários/diagnóstico por imagem , Stents Farmacológicos , Infarto do Miocárdio/terapia , Neointima/patologia , Idoso , Angina Estável/patologia , Angina Instável/patologia , Angiografia Coronária , Feminino , Humanos , Hiperplasia , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/patologia , Neointima/diagnóstico por imagem , Paclitaxel , Ensaios Clínicos Controlados Aleatórios como Assunto , Stents , Moduladores de Tubulina , Ultrassonografia de Intervenção
6.
Catheter Cardiovasc Interv ; 82(3): 352-9, 2013 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-22927100

RESUMO

BACKGROUND: The provisional approach for bifurcation stenting with side-branch balloon angioplasty is associated with dissections and suboptimal results requiring kissing balloon techniques or bailout stenting. We hypothesized that using a scoring balloon for the side branch and a drug-eluting stent for the main vessel might improve outcomes of true bifurcation lesions. METHODS AND RESULTS: A total of 93 patients with complex bifurcations were enrolled in a multicenter, single-arm, prospective clinical trial. A drug-eluting stent was deployed in the main vessel following dilatation of the side-branch stenosis with a scoring balloon. The overall angiographic success rate was 93.5%, and procedural success rate was 91.4%. The final diameter stenosis was 13.9% ± 7.2% for the main vessel and 33.3% ± 22.9% for the side branch. Crossover to stent deployment in the side branch was required in 10.8%. The postscoring balloon dissection rate was 8.2% and 6% (all ≤ class C) for the main vessel and side branch respectively, which was reduced to 1.1 and 2.1% poststenting. At 9-month follow-up, the composite MACE rate [cardiac death, myocardial infarction, or target lesion revascularization (TLR)] was 5.4%, including a TLR rate of 3.3% (1.1% from hospital discharge to 9 months). CONCLUSION: The 9-month results of the AGILITY trial support a simple provisional strategy for treating complex true bifurcation lesions with deployment of a drug-eluting stent in the main vessel after dilatation of the side-branch vessel with a scoring balloon. This strategy was associated with excellent and safe procedural results, a low rate of crossover to side-branch stenting, and favorable outcomes.


Assuntos
Angioplastia Coronária com Balão/instrumentação , Cateteres Cardíacos , Estenose Coronária/terapia , Idoso , Angioplastia Coronária com Balão/efeitos adversos , Angioplastia Coronária com Balão/mortalidade , Angiografia Coronária , Estenose Coronária/diagnóstico , Estenose Coronária/mortalidade , Trombose Coronária/etiologia , Stents Farmacológicos , Desenho de Equipamento , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/etiologia , Estudos Prospectivos , Sistema de Registros , Fatores de Tempo , Resultado do Tratamento , Estados Unidos
7.
Am J Cardiol ; 110(8): 1119-24, 2012 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-22762711

RESUMO

Registry Experience at the Washington Hospital Center, DES - Taxus Liberte Versus Xience V (REWARDS TLX) is a physician-initiated, retrospective, real-world, multicenter, observational study for all patients >18 years of age subjected to percutaneous coronary intervention with everolimus-eluting stents (EESs) or paclitaxel-eluting stents (PESs). Outcomes of patients receiving a TAXUS Liberté or XIENCE V drug-eluting stent were compared. Baseline clinical, procedural, and follow-up data at 12 months were collected from 10 clinical centers by an electronic data capture system. The study's primary end point was major adverse cardiac events: a composite of all-cause death, Q-wave myocardial infarction, target vessel revascularization, and stent thrombosis. The trial is registered with http://www.clinicaltrials.gov (NCT01134159). Data were entered for 1,195 patients (PES, n = 595; EES, n = 600). Baseline clinical characteristics were similar except for higher dyslipidemia, systemic hypertension, and family history of coronary artery disease in the EES group. In-hospital outcome was similar between groups, with an overall in-hospital stent thrombosis rate of 0.2%. The primary end point at 12 months was similar (EES 7.8% vs 10.8%, p = 0.082). Overall stent thrombosis rate was lower in the EES group (0.3% vs 1.2%, respectively, p = 0.107); however, target lesion revascularization was similar (PES, hazard ratio 1.46, 95% confidence interval 0.98 to 2.19, p = 0.064). There was no difference in overall mortality between groups. In conclusion, second-generation EESs and PESs demonstrated similar efficacy and safety profiles for broadened patient and lesion subsets compared to a selected population from the pivotal trials. However, for composite efficacy and safety end points, EESs outperformed second-generation PESs.


Assuntos
Doença da Artéria Coronariana/terapia , Stents Farmacológicos , Imunossupressores/administração & dosagem , Paclitaxel/administração & dosagem , Sirolimo/análogos & derivados , Moduladores de Tubulina/administração & dosagem , Idoso , Angiografia Coronária , Everolimo , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Sirolimo/administração & dosagem , Resultado do Tratamento , Estados Unidos
8.
J Interv Cardiol ; 25(4): 353-63, 2012 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-22612261

RESUMO

BACKGROUND: With the changing health care environment, cost effectiveness is an important adjunct to clinical investigation when assessing new medical devices. This study presents an economic model to evaluate cost effectiveness of coronary stents. METHODS: Markov modeling was developed comparing total costs (Medicare payer perspective) between TAXUS Liberté and TAXUS Express based on 3-year clinical outcomes from the TAXUS ATLAS Small Vessel and Long Lesion trials. RESULTS: The TAXUS Liberté 2.25-mm stent provided cost savings relative to TAXUS Express from a payer perspective ($17,605 vs. $20,281), driven by reduced target vessel revascularization (0.16 events/patient vs. 0.33 events/patient). In probabilistic sensitivity analyses, TAXUS Liberté was less costly with fewer major adverse cardiac events in over 99% of parameter sets. The TAXUS Liberté Long (38 mm) stent was cost neutral relative to TAXUS Express from a payer perspective ($18,545 vs. $18,551) with fewer myocardial infarctions and cardiac deaths. Accounting for angiography-driven revascularizations, TAXUS Liberté 2.25 mm still provided cost savings relative to TAXUS Express ($16,822 vs. $19,139), although TAXUS Liberté Long was more expensive than TAXUS Express ($17,886 vs. $17,652). From a hospital perspective, TAXUS Liberté Long provided cost savings up to a price premium of $671/stent, driven by fewer stents employed per patient. CONCLUSIONS: This analysis confirms the utility of economic modeling in assessing new stent platforms. TAXUS Liberté 2.25 mm is economically dominant relative to TAXUS Express when treating small vessels. TAXUS Liberté Long is cost neutral to modestly more costly than TAXUS Express 2.25 mm from a payer perspective.


Assuntos
Doença da Artéria Coronariana/economia , Stents Farmacológicos/economia , Modelos Econômicos , Antineoplásicos Fitogênicos/uso terapêutico , Doença da Artéria Coronariana/terapia , Análise Custo-Benefício , Stents Farmacológicos/efeitos adversos , Humanos , Cadeias de Markov , Paclitaxel/uso terapêutico , Estudos Retrospectivos , Resultado do Tratamento
9.
Circ Cardiovasc Interv ; 5(2): 211-9, 2012 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-22496083

RESUMO

BACKGROUND: Previous studies have not addressed vessel response >5 mm distal to the stent edge. Therefore, we investigated the impact of paclitaxel-eluting stents (PES) versus bare metal stents (BMS) on distal vessels in the serial intravascular ultrasound substudies of TAXUS IV, V, and VI. METHODS AND RESULTS: TAXUS IV, V, and VI were double-blind, randomized, multicenter, controlled trials comparing PES with BMS. In their intravascular ultrasound substudies, 103 patients (54 BMS, 49 PES) had intravascular ultrasound data ≥10 mm distal to the stent both postprocedure and at 9 months follow-up. Baseline characteristics were similar between the 2 groups. Multilevel modeling was used to account for the variation between patients and within patients among distal segments. Effect of stent type, time, and their interaction was tested using a mixed effect model controlling for distal segments. Postprocedure lumen and vessel were not significantly different between PES versus BMS; however, lumen (P=0.006) and vessel (P=0.0001) were significantly reduced for BMS at 9-month follow-up but not for PES. Conversely, there was a significant plaque increase from postprocedure to 9-month follow-up for PES (P=0.0008) but not for BMS. These vessel responses were statistically consistent among 0- to 5-mm versus 5- to 10-mm versus 10- to 15-mm segments distal to the stent in both groups. CONCLUSIONS: PES use was associated with plaque increase from baseline to 9-month follow-up >5 mm distal to the stent along with positive remodeling, whereas BMS use was associated with negative remodeling and no plaque increase. These vessel responses were consistent in 5-mm long subsegments: 0 to 5 mm versus 5 to 10 mm versus 10 to 15 mm distal to the stent. CLINICAL TRIAL REGISTRATION: URL: HTTP://WWW.CLINICALTRIAL.GOV. Unique identifiers: TAXUS IV: NCT00292474; TAXUS V: NCT00301522; TAXUS VI: NCT00297804.


Assuntos
Implante de Prótese Vascular , Doença da Artéria Coronariana/tratamento farmacológico , Oclusão Coronária/tratamento farmacológico , Stents Farmacológicos/efeitos adversos , Paclitaxel/administração & dosagem , Complicações Pós-Operatórias/tratamento farmacológico , Idoso , Doença da Artéria Coronariana/patologia , Doença da Artéria Coronariana/cirurgia , Oclusão Coronária/patologia , Oclusão Coronária/cirurgia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Paclitaxel/efeitos adversos , Complicações Pós-Operatórias/patologia , Complicações Pós-Operatórias/cirurgia , Ultrassonografia de Intervenção , Cicatrização
10.
Am J Cardiol ; 108(6): 828-37, 2011 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-21803319

RESUMO

Stent design, metal alloy composition, and strut thickness may influence late lumen loss and clinical outcomes after bare metal stent deployment; however, their impact on outcomes after drug-eluting stent deployment is unknown. Although the TAXUS Liberté and ION paclitaxel-eluting stents use similar polymer and drug, the ION stent incorporates a novel thin-strut platinum chromium metal alloy and cell design. We therefore compared patient-level data from 2,298 subjects enrolled into the TAXUS ATLAS (TAXUS Liberté) and PERSEUS (ION) clinical trials. Propensity-score (1:1) matching was performed to adjust for covariate imbalance between stent types. Twelve-month major adverse cardiac events were less frequent after use of the ION compared to the TAXUS Liberté (12.7% vs 8.3%, p <0.001, unadjusted; 12.0% vs 7.5%, p = 0.007, propensity matched) largely because of decreased non-Q-wave myocardial infarction (MI; 2.9% vs 1.4%, p = 0.01, unadjusted; 3.2% vs 0.9%, p = 0.004, propensity matched). The MI difference was predominantly periprocedural and in patients treated with a single stent. In conclusion, this exploratory post hoc analysis demonstrated that the ION was associated with fewer adverse clinical events than the TAXUS Liberté because of decreased non-Q-wave MI. Stent platform-related variables may influence clinical outcomes after drug-eluting stent use despite similar polymer and drug elution. Differences in adjunctive pharmacotherapy and/or stenting technique may also be contributory.


Assuntos
Reestenose Coronária/prevenção & controle , Stents Farmacológicos , Infarto do Miocárdio/prevenção & controle , Paclitaxel/administração & dosagem , Moduladores de Tubulina/administração & dosagem , Distribuição de Qui-Quadrado , Ensaios Clínicos como Assunto , Feminino , Humanos , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Pontuação de Propensão , Desenho de Prótese , Medição de Risco , Fatores de Risco , Resultado do Tratamento
11.
JACC Cardiovasc Interv ; 4(5): 543-50, 2011 May.
Artigo em Inglês | MEDLINE | ID: mdl-21596327

RESUMO

OBJECTIVES: This study sought to compare late safety and efficacy outcomes following percutaneous coronary revascularization with zotarolimus-eluting stents (ZES) and sirolimus-eluting stents (SES). BACKGROUND: Despite higher late lumen loss and binary restenosis with ZES compared with SES, it is uncertain whether differences in early angiographic measures translate into more disparate late clinical events. METHODS: Clinical outcomes were prospectively evaluated through 5 years in the ENDEAVOR III (A Randomized Controlled Trial of the Medtronic Endeavor Drug [ABT-578] Eluting Coronary Stent System Versus the Cypher Sirolimus-Eluting Coronary Stent System in De Novo Native Coronary Artery Lesions) that randomized 436 patients of relatively low anatomic and clinical risk to treatment with ZES (n = 323) or SES (n = 113) and evaluated a primary endpoint of 8-month angiographic late lumen loss. RESULTS: At 5 years (completeness of follow-up: 95.2%), pre-specified endpoints of all-cause mortality (5.2% vs. 13.0%, p = 0.02), myocardial infarction (1.0% vs. 4.6%, p = 0.03), and the composite event rates of cardiac death/myocardial infarction (1.3% vs. 6.5%, p = 0.009) and major adverse cardiac events (14.0% vs. 22.2%, p = 0.05) were significantly lower among patients treated with ZES. Rates of target lesion (8.1% ZES vs. 6.5% SES, p = 0.68) and target vessel revascularization were similar between treatment groups. Stent thrombosis was infrequent and similar in both groups (0.7% ZES vs. 0.9% SES, p = 1.0). Between 9 months and 5 years, progression of major adverse cardiac events was significantly more common with SES than with ZES (16.7% vs. 7.8%, p = 0.015). CONCLUSIONS: Despite initially higher angiographic late lumen loss, rates of clinical restenosis beyond the protocol-specified angiographic follow-up period remain stable with ZES compared with the rates for SES, resulting in similar late-term efficacy. Over 5 years, significant differences in death, myocardial infarction, and composite endpoints favored treatment with ZES. (The Medtronic Endeavor III Drug Eluting Coronary Stent System Clinical Trial [ENDEAVOR III]; NCT00217256).


Assuntos
Angioplastia Coronária com Balão/instrumentação , Fármacos Cardiovasculares/administração & dosagem , Doença da Artéria Coronariana/terapia , Stents Farmacológicos , Sirolimo/análogos & derivados , Idoso , Angioplastia Coronária com Balão/efeitos adversos , Angioplastia Coronária com Balão/mortalidade , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/mortalidade , Reestenose Coronária/diagnóstico por imagem , Reestenose Coronária/etiologia , Feminino , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/etiologia , Estudos Prospectivos , Desenho de Prótese , Medição de Risco , Fatores de Risco , Sirolimo/administração & dosagem , Trombose/etiologia , Fatores de Tempo , Resultado do Tratamento
12.
Expert Rev Med Devices ; 8(3): 303-6, 2011 May.
Artigo em Inglês | MEDLINE | ID: mdl-21542702

RESUMO

The Integrity Coronary Stent System (Medtronic Vascular, CA, USA) is a low-profile, open-cell, cobalt-chromium-alloy advanced bare-metal iteration of the well-known Driver/Micro-Driver Coronary Stent System (Medtronic Vascular). The Integrity stent is made with a process called continuous sinusoid technology. This process allows stent construction via wrapping a single thin strand of wire around a mandrel in a sinusoid configuration, with laser fusion of adjacent crowns. The wire-forming process and fusion pattern provide the stent with a continuous preferential bending plane, intended to allow easier access to, and smoother tracking within, distal and tortuous vessels while radial strength is maintained. Continuous sinusoid technology represents innovation in the design of stent platforms and will provide a future stent platform for newer technology, including drug-eluting stent platforms, drug-filled stents and core wire stents.


Assuntos
Desenho de Prótese/métodos , Stents , Ligas de Cromo , Ensaios Clínicos como Assunto , Humanos
13.
Circ J ; 75(5): 1120-9, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-21467655

RESUMO

BACKGROUND: The long-term impact of treating de novo coronary lesions in native vessels and challenging small vessel and long lesion subsets with TAXUS Liberté stents is unknown. This report examines the 3-year efficacy and safety from the TAXUS ATLAS program. METHODS AND RESULTS: TAXUS ATLAS WH, Small Vessel, and Long Lesion are non-randomized studies comparing TAXUS Liberté (n = 871), TAXUS Liberté 2.25 mm (n = 261), and TAXUS Liberté 38 mm (n = 150) stents, respectively, to case-matched TAXUS Express historical controls. TAXUS Liberté demonstrated comparable 3-year rates of major adverse cardiac events (19.0% vs. 20.2%, P = 0.51) in de novo lesions, reduced target lesion revascularization (TLR, 10.0% vs. 22.1%, P = 0.008) in small vessels, and reduced myocardial infarction (MI, 2.9% vs. 10.4%; P = 0.01) and stent thrombosis (ST, 0.0% vs. 3.9%, P = 0.03) in long lesions vs. TAXUS Express. After propensity score adjustment, no statistically significant effect of TAXUS Liberté on TLR (9.7% vs. 16.9%, P = 0.12) in small vessels or MI (2.9% vs. 7.9%, P = 0.05) in long lesions was noted, although reduced ST (0.0% vs. 2.7%, P = 0.02) remained in long lesions. Multivariate analyses demonstrated that TAXUS Liberté treatment significantly reduced TLR by 66% in small vessels, and MI by 75% in long lesions, vs. TAXUS Express. CONCLUSIONS: TAXUS Liberté suggests durable 3-year effectiveness in reducing restenosis and improved clinical outcomes in small vessels and long lesions compared with TAXUS Express.


Assuntos
Stents , Humanos , Taxus
16.
Cardiovasc Revasc Med ; 12(4): 247-57, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-21130708

RESUMO

BACKGROUND: The objective of this intravascular ultrasound (IVUS) analysis was to evaluate the vascular response of the thin-strut TAXUS Liberté stent compared with the otherwise identical TAXUS Express stent. METHODS AND MATERIALS: The TAXUS ATLAS and TAXUS ATLAS Long Lesion studies are nonrandomized trials comparing the thin-strut TAXUS Liberté stent to historical TAXUS Express controls from the TAXUS IV and TAXUS V trials. A total of 377 patients enrolled in the two TAXUS ATLAS studies were randomly selected for the IVUS subset and compared to 314 TAXUS Express IVUS controls. RESULTS: Despite increased lesion complexity in the TAXUS Liberté group, neointimal formation at 9 months was similar in both stents (TAXUS Liberté 13.8±11.0%; TAXUS Express 13.1±13.8%, P=.56). However, this neointima covered more of the overall stent in the TAXUS Liberté (67.9±32.5%) compared with the TAXUS Express (54.4±37.2%, P<.001), suggesting more uniform neointimal distribution. TAXUS Liberté also showed less pronounced negative remodeling at both stent edges and had significantly less (4.3% vs. 9.6%, P=.04) late incomplete stent apposition (ISA). CONCLUSIONS: Despite identical polymer and drug release characteristic, the thin-strut TAXUS Liberté stent demonstrates improved neointimal coverage, better edge remodeling, and less late ISA vs. TAXUS Express, hereby highlighting the importance of the platform design for drug-eluting stents.


Assuntos
Reestenose Coronária/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Stents Farmacológicos , Desenho de Prótese/métodos , Fármacos Cardiovasculares/administração & dosagem , Reestenose Coronária/prevenção & controle , Estenose Coronária/cirurgia , Vasos Coronários/efeitos dos fármacos , Vasos Coronários/cirurgia , Método Duplo-Cego , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Paclitaxel/administração & dosagem , Estudos Prospectivos , Stents , Resultado do Tratamento , Túnica Íntima/diagnóstico por imagem , Túnica Íntima/efeitos dos fármacos , Ultrassonografia de Intervenção/métodos
17.
JACC Cardiovasc Interv ; 3(5): 486-94, 2010 May.
Artigo em Inglês | MEDLINE | ID: mdl-20488404

RESUMO

OBJECTIVES: We sought to determine the 2-year impact of early and late-acquired incomplete stent apposition (ISA) on clinical events. BACKGROUND: The late clinical impact of early or late-acquired ISA in bare-metal stents (BMS) and TAXUS stents (Boston Scientific, Natick, Massachusetts) is debatable. METHODS: We evaluated 1,580 patients enrolled in the intravascular ultrasound (IVUS) substudies of TAXUS IV, V, VI and TAXUS-ATLAS WH, LL, and DS trials. RESULTS: There were 96 cases of early ISA in 26 (7.2%) BMS patients, 35 (9.7%) TAXUS Express patients (p = 0.28 vs. BMS), and 35 (7.3%) TAXUS Liberté patients (p = 0.21 vs. TAXUS Express, and p = 1.00 vs. BMS). Major adverse cardiovascular events were similar at 9 months in patients with early ISA versus control subjects with no ISA for BMS (3.8% vs. 15.2%, p = 0.13) and for TAXUS (11.6% vs. 8.8%, p = 0.45). There was no impact of early ISA on stent thrombosis. At 9-month follow-up, there were 36 cases of late-acquired ISA in 7 (2.7%) BMS patients, 17 (3.1%) patients with TAXUS slow-release (TAXUS Express or TAXUS Liberté), and 12 (15.4%) patients receiving TAXUS moderate-release. Over 2 ensuing years, major adverse cardiovascular events were similar in patients with late-acquired ISA versus control subjects with no ISA for BMS (14.3% vs. 7.9%, p = 0.54), TAXUS (overall, 8.3% vs. 8.1% p = 0.87), or TAXUS slow-release formulation (0% vs. 7.9%, p = 0.28). There was no impact of late-acquired ISA on stent thrombosis. CONCLUSIONS: Neither routinely detected acute ISA nor routinely detected late-acquired ISA in BMS or TAXUS patients was associated with adverse clinical events over long-term follow-up.


Assuntos
Angioplastia Coronária com Balão/instrumentação , Fármacos Cardiovasculares/administração & dosagem , Doenças Cardiovasculares/diagnóstico por imagem , Stents Farmacológicos , Paclitaxel/administração & dosagem , Stents , Ultrassonografia de Intervenção , Idoso , Angioplastia Coronária com Balão/efeitos adversos , Doenças Cardiovasculares/etiologia , Angiografia Coronária , Reestenose Coronária/diagnóstico por imagem , Reestenose Coronária/etiologia , Método Duplo-Cego , Feminino , Humanos , Estimativa de Kaplan-Meier , Masculino , Metais , Pessoa de Meia-Idade , Estudos Prospectivos , Desenho de Prótese , Trombose/diagnóstico por imagem , Trombose/etiologia , Fatores de Tempo , Resultado do Tratamento
18.
Am J Cardiol ; 105(8): 1060-4, 2010 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-20381653

RESUMO

The incidence and predictors of major adverse cardiac events after percutaneous coronary intervention of saphenous vein grafts have not been evaluated in the era of routine embolic protection device (EPD) use and the current standards of antiplatelet therapy. The Assessment of the Medtronic AVE Interceptor Saphenous Vein Graft Filter System (AMEthyst) is the largest randomized trial of vein graft intervention comparing the Interceptor EPD and either the GuardWire or FilterWire EPD as the control. The baseline demographic, procedural, and clinical characteristics and the 30-day major adverse cardiac events ([MACE] death, myocardial infarction, and repeat revascularization [either surgery or percutaneous coronary intervention] of the target vessel) were recorded for 748 patients who had undergone vein graft intervention with distal embolic protection. At 30 days, MACE had occurred in 58 patients (7.8%). The univariate predictors of MACE at 30 days included plaque volume (odds ratio 1.005/mm(3), p <0.0001), target lesion length (odds ratio 1.046/mm, p <0.001), vein graft degeneration score (odds ratio 1.631, p = 0.001), coronary narrowing classification (odds ratio 1.697, p = 0.004), reference vessel diameter (odds ratio 1.689, p = 0.004), and male gender (odds ratio 2.406, p = 0.046) and was independent of device type (p = 0.74). The plaque volume was the most important and only multivariate predictor of MACE. The highest quartile of plaque volume defined a subset at particular risk, despite EPD use (MACE 15.8% vs 5.0%, p <0.001). In conclusion, in a patient population in which EPD and preprocedure thienopyridine therapy were uniformly implemented, MACE occurred with an incidence of 7.8% at 30 days. An increasing plaque volume was the most important determinant of MACE and defined a population at particular risk.


Assuntos
Estenose Coronária/cirurgia , Stents Farmacológicos , Embolia/prevenção & controle , Infarto do Miocárdio/epidemiologia , Revascularização Miocárdica/efeitos adversos , Veia Safena/transplante , Idoso , Clopidogrel , Angiografia Coronária , Estenose Coronária/diagnóstico por imagem , Embolia/epidemiologia , Embolia/etiologia , Feminino , Humanos , Incidência , Masculino , Infarto do Miocárdio/diagnóstico , Infarto do Miocárdio/etiologia , Revascularização Miocárdica/métodos , Inibidores da Agregação Plaquetária/farmacologia , Prognóstico , Fatores de Risco , Taxa de Sobrevida , Ticlopidina/análogos & derivados , Ticlopidina/farmacologia , Estados Unidos/epidemiologia
19.
J Am Coll Cardiol ; 55(24): 2721-6, 2010 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-20399059

RESUMO

OBJECTIVES: This report describes the final results of the ARBITER 6-HALTS (Arterial Biology for the Investigation of the Treatment Effects of Reducing Cholesterol 6-HDL and LDL Treatment Strategies in Atherosclerosis) trial. BACKGROUND: The ARBITER 6-HALTS trial was terminated early on the basis of a pre-specified interim analysis showing superiority of niacin over ezetimibe on change in carotid intima-media thickness (CIMT). After termination, an additional 107 subjects completed a close-out assessment. METHODS: Patients with coronary heart disease (CHD) or CHD equivalent with low-density lipoprotein cholesterol <100 mg/dl and high-density lipoprotein cholesterol <50 mg/dl for men or 55 mg/dl for women while receiving stable statin treatment were randomly assigned to ezetimibe (10 mg/day) or extended-release niacin (target dose, 2,000 mg/day). The primary end point was change in mean CIMT, analyzed according to a last observation carried forward method. The relationships of study medication adherence, dosage, and cumulative exposure (product of adherence, dose, and time) with change in CIMT were explored. RESULTS: Results in 315 patients included 208 with 14-month follow-up and 107 after mean treatment of 7 +/- 3 months. Niacin (n = 154) resulted in significant reduction (regression) in mean CIMT (-0.0102 +/- 0.0026 mm; p < 0.001) and maximal CIMT (-0.0124 +/- 0.0036 mm; p = 0.001), whereas ezetimibe (n = 161) did not reduce mean CIMT (-0.0016 +/- 0.0024 mm; p = 0.88) or maximal CIMT (-0.0005 +/- 0.0029 mm; p = 0.88) compared with baseline. There was a significant difference between ezetimibe and niacin treatment groups on mean changes in CIMT, favoring niacin, for both mean CIMT (p = 0.016) and maximal CIMT (p = 0.01). Increased cumulative drug exposure was related to regression of CIMT with niacin, and progression of CIMT with ezetimibe. CONCLUSIONS: Niacin induces regression of CIMT and is superior to ezetimibe for patients taking statins. (Comparative Study of the Effect of Ezetimibe Versus Extended-Release Niacin on Atherosclerosis; NCT00397657).


Assuntos
Anticolesterolemiantes/administração & dosagem , Aterosclerose/tratamento farmacológico , HDL-Colesterol/efeitos dos fármacos , LDL-Colesterol/efeitos dos fármacos , Doença das Coronárias/tratamento farmacológico , Adesão à Medicação , Idoso , Aterosclerose/sangue , Aterosclerose/diagnóstico , Azetidinas/administração & dosagem , Artéria Carótida Primitiva/diagnóstico por imagem , HDL-Colesterol/sangue , LDL-Colesterol/sangue , Doença das Coronárias/sangue , Doença das Coronárias/diagnóstico , Relação Dose-Resposta a Droga , Ezetimiba , Feminino , Seguimentos , Humanos , Masculino , Niacina/administração & dosagem , Método Simples-Cego , Fatores de Tempo , Resultado do Tratamento , Túnica Íntima/diagnóstico por imagem , Ultrassonografia
20.
JACC Cardiovasc Interv ; 3(4): 403-11, 2010 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-20398868

RESUMO

OBJECTIVES: The aim of this study was to study the long-term clinical effects of routine angiographic follow-up and related reintervention after drug-eluting stenting. BACKGROUND: Prior stent trials have shown that protocol-mandated angiographic follow-up increases repeat interventions compared with clinical follow-up alone. The long-term clinical impact of this practice is unknown. METHODS: Long-term outcomes of patients assigned to routine angiographic follow-up in 3 large-scale TAXUS (Boston Scientific, Natick, Massachusetts) trials were compared with patients assigned to clinical follow-up alone, in a propensity score-adjusted patient-level meta-analysis. Outcomes were also compared in patients with treated versus untreated nonischemic intermediate lesions (quantitative angiographic stenosis between >or=40% and <70%) detected at angiographic follow-up. RESULTS: Target lesion revascularization (TLR) rates at 5 years were significantly higher in the angiographic compared with clinical follow-up cohort (18.3% vs. 11.1%, p < 0.001). This was due to more frequent treatment of intermediate lesions, but there was no associated reduction in rates of cardiac death or myocardial infarction (8.9% vs. 8.8%, p = 0.93). Of patients with nonischemic intermediate lesions, 17% who were not revascularized at the time of angiographic follow-up had a subsequent TLR, whereas 7% of patients who had TLR at this follow-up angiogram required additional revascularization during long-term follow-up. CONCLUSIONS: A strategy of routine angiographic follow-up increases oculostenotic revascularization of nonischemic intermediate lesions without affecting subsequent rates of cardiac death or myocardial infarction, and TLR was not required in 83% of those lesions. A conservative approach, in which repeat angiography is limited to patients with recurrent ischemia or progressive symptoms, minimizes repeat revascularization of nonischemic intermediate lesions and optimizes long-term event-free survival after drug-eluting stent implantation.


Assuntos
Angioplastia Coronária com Balão/instrumentação , Angiografia Coronária , Reestenose Coronária/diagnóstico por imagem , Reestenose Coronária/terapia , Estenose Coronária/diagnóstico por imagem , Estenose Coronária/terapia , Stents Farmacológicos , Ensaios Clínicos Controlados Aleatórios como Assunto , Idoso , Angioplastia Coronária com Balão/efeitos adversos , Angioplastia Coronária com Balão/mortalidade , Distribuição de Qui-Quadrado , Reestenose Coronária/etiologia , Reestenose Coronária/mortalidade , Estenose Coronária/mortalidade , Intervalo Livre de Doença , Feminino , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/diagnóstico por imagem , Infarto do Miocárdio/etiologia , Isquemia Miocárdica/diagnóstico por imagem , Isquemia Miocárdica/etiologia , Valor Preditivo dos Testes , Pontuação de Propensão , Modelos de Riscos Proporcionais , Desenho de Prótese , Medição de Risco , Fatores de Risco , Índice de Gravidade de Doença , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA