Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 171
Filtrar
1.
Phys Rev E ; 109(6-1): 064701, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-39020918

RESUMO

Polymer dispersed liquid crystal (PDLC) films are formed of droplets of liquid crystal (LC) held in a polymer matrix. Similar to aligned LC films, PDLCs exhibit the acousto-optic (AO) effect when excited by acoustic waves of sufficient amplitude, whereby the PDLC film becomes transparent in the excited regions (acoustic clearing). Despite decades of research there is still debate over the mechanisms of the AO effect for the case of LC films, with several competing theories, and AO effects in PDLC have not been studied theoretically. This paper explores the AO effect in PDLC both experimentally and theoretically, and attempts a theoretical description of the observed phenomena based on the theoretical approach by Selinger et al. for aligned LC films. The acousto-optic effect in PDLC is shown to be due to direct interaction of acoustic waves with LC droplets, rather than due to compression of the droplet itself. Polarizing microscopy revealed changes in droplet shape at excited points. This is consistent with reorientation as a contributing factor, possibly coexisting with flows at higher excitation powers. In previous experimental studies PDLC films were prepared with cover slides, in the same way as LC AO cells, significantly limiting applications by adding complexity to the design. Also, to exhibit AO clearing it was considered that the PDLC needed to be prepared with high LC concentrations (over 75% by weight). We demonstrate that no cover slide is necessary, and that PDLC coatings without a cover have improved sensitivity to acoustic waves. We demonstrate the AO effect for LC concentrations as low as 40% by weight. The ability to use standard composition PDLC, with no top cover, is paving the way to paint-on visual ultrasound sensors.

3.
Ultrasonics ; 141: 107352, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38820871

RESUMO

Wavefield imaging can be used for measuring the wavefield produced by an ultrasound transducer for medical and industrial applications, or for the detection and monitoring of defects in non-destructive testing. Typical wavefield imaging methods include interferometry/vibrometry, and the use of microphones and hydrophones. These involve scanning, making them time consuming, and microphones have limited resolution. An alternative method presented here uses thermochromic liquid crystal sensors which react to heat generated due to absorption of ultrasonic waves. The result is a colour scale that varies with temperature, with the temperature change dependent on ultrasonic displacement. Measurements of the resonant modes of a flexural ultrasonic transducer were taken between 320 kHz and 6.77 MHz. Temperature maps were obtained from photographs of the TLC sensor using the true-colour image processing method. The obtained temperature change across the transducer face was compared with displacement measurements taken using interferometry, showing excellent agreement in the position of the mode features and good resolution at lower frequencies. Thermal measurements were also taken to directly observe the heating of the transducer cap, showing the effect of the thermal conductivity of the transducer along with confirming the increased heat generated by the ultrasound absorption when a backing layer is used. The sensors show promise for fast transducer characterisation, with further potential applications in structural health monitoring and defect detection.

4.
Ultrasonics ; 140: 107300, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38537517

RESUMO

Acoustic field and vibration visualisation is important in a wide range of applications. Laser vibrometry is often used for such visualisation, however, the equipment has a high cost and requires significant user expertise, and the method can be slow, as it requires scanning point by point. Here we suggest a different approach to visualisation of acoustic fields in the kHz - MHz range, using paint-on or removable film sensors, which produce a direct visual map of ultrasound displacement. The sensors are based on a film containing thermochromic liquid crystals (TLC), along with a backing/underlay layer which improves absorption of ultrasound. The absorption generates heat, which can be seen by a change in colour of the TLC film. A removable sensor is used to visualise the resonant modes of an air-coupled flexural transducer operated from 410 kHz to 7.23 MHz, and to visualise 40 kHz standing waves in a Perspex plate. The thermal basis of the visualisation is confirmed using thermal imaging. The speed and cost of visualisation makes the new sensor attractive for use in condition monitoring, for fast assessment of transducer quality, or for analysis of acoustic field distribution in power ultrasonic systems.

5.
Biol Cybern ; 109(1): 63-73, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25201495

RESUMO

Bipedal gaits have been classified on the basis of the group symmetry of the minimal network of identical differential equations (alias cells) required to model them. Primary bipedal gaits (e.g., walk, run) are characterized by dihedral symmetry, whereas secondary bipedal gaits (e.g., gallop-walk, gallop- run) are characterized by a lower, cyclic symmetry. This fact has been used in tests of human odometry (e.g., Turvey et al. in P Roy Soc Lond B Biol 276:4309-4314, 2009, J Exp Psychol Hum Percept Perform 38:1014-1025, 2012). Results suggest that when distance is measured and reported by gaits from the same symmetry class, primary and secondary gaits are comparable. Switching symmetry classes at report compresses (primary to secondary) or inflates (secondary to primary) measured distance, with the compression and inflation equal in magnitude. The present research (a) extends these findings from overground locomotion to treadmill locomotion and (b) assesses a dynamics of sequentially coupled measure and report phases, with relative velocity as an order parameter, or equilibrium state, and difference in symmetry class as an imperfection parameter, or detuning, of those dynamics. The results suggest that the symmetries and dynamics of distance measurement by the human odometer are the same whether the odometer is in motion relative to a stationary ground or stationary relative to a moving ground.


Assuntos
Percepção de Distância/fisiologia , Marcha/fisiologia , Locomoção/fisiologia , Modelos Biológicos , Adolescente , Simulação por Computador , Teste de Esforço , Feminino , Humanos , Masculino , Rede Nervosa/fisiologia , Estatísticas não Paramétricas
6.
Rev Sci Instrum ; 85(2): 02B111, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24593551

RESUMO

Extraction of negative ions from a saddle antenna radio-frequency surface plasma source is considered. Several versions of new plasma generators with different antennas and magnetic field configurations were tested in the smal Oak Ridge National Laboratory Spallation Neutron Source Test Stand. The efficiency of positive ion generation in plasma has been improved to 200 mA/cm(2) kW from 2.5 mA/cm(2) kW. A small oven was developed for cesiation by cesium compounds and alloy decomposition. After cesiation, a current of negative ions to the collector was increased from 1 mA to 10 mA with 1.5 kW RF power in the plasma and longitudinal magnetic field Bl ∼ 250 G. The specific efficiency of H(-) production was increased to 20 mA/cm(2) kW from 2.5 mA/cm(2) kW.

7.
Rev Sci Instrum ; 85(2): 02B135, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24593575

RESUMO

The Spallation Neutron Source (SNS), a large scale neutron production facility, routinely operates with 30-40 mA peak current in the linac. Recent measurements have shown that our RF-driven internal antenna, Cs-enhanced, multi-cusp ion sources injects ∼55 mA of H(-) beam current (∼1 ms, 60 Hz) at 65-kV into a Radio Frequency Quadrupole (RFQ) accelerator through a closely coupled electrostatic Low-Energy Beam Transport system. Over the last several years a decrease in RFQ transmission and issues with internal antennas has stimulated source development at the SNS both for the internal and external antenna ion sources. This report discusses progress in improving internal antenna reliability, H(-) yield improvements which resulted from modifications to the outlet aperture assembly (applicable to both internal and external antenna sources) and studies made of the long standing problem of beam persistence with the external antenna source. The current status of the external antenna ion source will also be presented.

8.
Exp Brain Res ; 231(4): 383-96, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-24162860

RESUMO

"Quiet standing" is standing without intended movement. To the naked eye, a person "quiet standing" on a rigid surface of support is stationary. In the laboratory quiet standing is indexed by behavior (at the millimeter scale) of the center of pressure (COP), the point location of the vertical ground reaction force vector (GRF). We asked whether quiet standing is lateralized and whether the COP dynamics of the right and left legs differ. In answer, we reexamined a previous quiet standing experiment (Kinsella-Shaw et al. in J Mot Behav 38:251-264, 2006) that used dual, side-by-side, force plates to investigate effects of age and embedding environment. All participants, old (M age = 72.2 ± 4.90 years) and young (M age = 22.8 ± 0.83 years), were right handed and right footed. Cross-recurrence quantification of the anterior-posterior and mediolateral coordinates of each COP revealed that, independent of age, and with no right GRF bias, right-leg coordination was (1) more dynamically stable and less noisy than left-leg coordination and (2) more responsive to changes in degree of visible structure. The results are considered in the context of theories of laterality inclusive of lateralized differences in postural dynamics.


Assuntos
Envelhecimento/fisiologia , Lateralidade Funcional/fisiologia , Equilíbrio Postural/fisiologia , Adulto , Fatores Etários , Idoso , Fenômenos Biomecânicos/fisiologia , Feminino , Humanos , Perna (Membro)/fisiologia , Masculino , Modelos Teóricos , Postura/fisiologia , Adulto Jovem
9.
J Psycholinguist Res ; 42(2): 191-204, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-22485021

RESUMO

Reading a word may involve the spoken language in two ways: in the conversion of letters to phonemes according to the conventions of the language's writing system and the assimilation of phonemes according to the language's constraints on speaking. If so, then words that require assimilation when uttered would require a change in the phonemes produced by grapheme-phoneme conversion when read. In two experiments, each involving 40 fluent readers, we compared visual lexical decision on Korean orthographic forms that would require such a change (C stimuli) or not (NC stimuli). We found that NC words were accepted faster than C words, and C nonwords were rejected faster than NC nonwords. The results suggest that phoneme-to-phoneme transformations involved in uttering a word may also be involved in visually identifying the word.


Assuntos
Tomada de Decisões/fisiologia , Idioma , Reconhecimento Visual de Modelos/fisiologia , Leitura , Fala/fisiologia , Adulto , Humanos , Estimulação Luminosa , Tempo de Reação/fisiologia
10.
J Exp Psychol Hum Percept Perform ; 38(5): 1125-31, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-22731994

RESUMO

For skills that involve hitting a target, subsequent judgments of target size correlate with prior success in hitting that target. We used an archery context to examine the judgment-success relationship with varied target sizes in the absence of explicit knowledge of results. Competitive archers shot at targets 50 m away that varied in size among five diameters. Immediately after the arrow's release, its flight and landing were occluded and archers chose which of 18 miniature targets looked most like the distal target. Greater apparent size correlated with higher accuracy. In a second experiment, nonarchers merely aimed the bow (without an arrow) at varied targets. Apparent size was larger when the bow arm was stabilized than when it was not. Archery is seemingly an instance of affordance-based control: For an archer, the affordance of the target is the "hitableness" of its central regions, a property inclusive of his or her momentary, and perceptible, archery form.


Assuntos
Desempenho Psicomotor/fisiologia , Percepção de Tamanho/fisiologia , Esportes/fisiologia , Adolescente , Atletas/psicologia , Humanos , Masculino , Testes Neuropsicológicos , Esportes/psicologia
11.
J Exp Psychol Hum Percept Perform ; 38(4): 1014-25, 2012 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-22506786

RESUMO

Bipedal gaits have been classified on the basis of the group symmetry of the minimal network of identical differential equations (alias cells) required to model them. Primary gaits are characterized by dihedral symmetry, whereas secondary gaits are characterized by a lower, cyclic symmetry. This fact was used in a test of human odometry. Results suggest that when distance is measured and reported by gaits from the same symmetry class, primary and secondary gaits are comparable. Switching symmetry classes at report compresses (primary to secondary) or inflates (secondary to primary) measured distance, with the compression and inflation equal in magnitude. Lessons are drawn from modeling the dynamics of behaviors executed in parallel (e.g., interlimb coordination) to model the dynamics of human odometry, in which the behaviors are executed sequentially. The major observations are characterized in terms of a dynamics of sequentially coupled measure and report phases, with relative velocity as an order parameter, or equilibrium state, and difference in symmetry class as an imperfection parameter, or detuning, of that dynamic.


Assuntos
Fenômenos Biomecânicos/fisiologia , Marcha/fisiologia , Locomoção/fisiologia , Adulto , Humanos , Modelos Psicológicos , Testes Neuropsicológicos , Percepção Espacial/fisiologia , Adulto Jovem
12.
Rev Sci Instrum ; 83(2): 02A725, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22380234

RESUMO

The Spallation Neutron Source (SNS) now routinely operates nearly 1 MW of beam power on target with a highly persistent ∼38 mA peak current in the linac and an availability of ∼90%. H(-) beam pulses (∼1 ms, 60 Hz) are produced by a Cs-enhanced, multicusp ion source closely coupled with an electrostatic low energy beam transport (LEBT), which focuses the 65 kV beam into a radio frequency quadrupole accelerator. The source plasma is generated by RF excitation (2 MHz, ∼60 kW) of a copper antenna that has been encased with a thickness of ∼0.7 mm of porcelain enamel and immersed into the plasma chamber. The ion source and LEBT normally have a combined availability of ∼99%. Recent increases in duty-factor and RF power have made antenna failures a leading cause of downtime. This report first identifies the physical mechanism of antenna failure from a statistical inspection of ∼75 antennas which ran at the SNS, scanning electron microscopy studies of antenna surface, and cross sectional cuts and analysis of calorimetric heating measurements. Failure mitigation efforts are then described which include modifying the antenna geometry and our acceptance∕installation criteria. Progress and status of the development of the SNS external antenna source, a long-term solution to the internal antenna problem, are then discussed. Currently, this source is capable of delivering comparable beam currents to the baseline source to the SNS and, an earlier version, has briefly demonstrated unanalyzed currents up to ∼100 mA (1 ms, 60 Hz) on the test stand. In particular, this paper discusses plasma ignition (dc and RF plasma guns), antenna reliability, magnet overheating, and insufficient beam persistence.

13.
J Mot Behav ; 44(1): 47-52, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22269023

RESUMO

Humans and other animals can measure distances nonvisually by legged locomotion. Experiments typically employ an outbound measure (M) and an inbound report (R) phase. Previous research has found distance reproduction to be maximally accurate, when gait symmetry and speed of M and R are of like kind: Successful human odometry manifests at the level of the M-R system. In the present work, M was an experimenter-set distance produced by a blindfolded participant using a primary gait (walk, run). R was always by walk. Fast and slow versions of walk and run were adopted by participants, such that when M was fast R was slow, and vice versa. Distance was underestimated when M was slower than R and overestimated when M was faster than R. However, the pattern of participant-adopted velocities indicated that it was the instructions, not the speed as such, that yielded the pattern of results. The results are interpretable through a dynamical perspective and indicate speed is an imperfection parameter acting on the attractors of the M-R system.


Assuntos
Percepção de Distância/fisiologia , Corrida/fisiologia , Caminhada/fisiologia , Feminino , Marcha/fisiologia , Humanos , Corrida Moderada/fisiologia , Locomoção/fisiologia , Masculino , Adulto Jovem
14.
Philos Trans R Soc Lond B Biol Sci ; 366(1581): 3123-32, 2011 Nov 12.
Artigo em Inglês | MEDLINE | ID: mdl-21969694

RESUMO

Dynamic touching is effortful touching. It entails deformation of muscles and fascia and activation of the embedded mechanoreceptors, as when an object is supported and moved by the body. It is realized as exploratory activities that can vary widely in spatial and temporal extents (a momentary heft, an extended walk). Research has revealed the potential of dynamic touching for obtaining non-visual information about the body (e.g. limb orientation), attachments to the body (e.g. an object's height and width) and the relation of the body both to attachments (e.g. hand's location on a grasped object) and surrounding surfaces (e.g. places and their distances). Invariants over the exploratory activity (e.g. moments of a wielded object's mass distribution) seem to ground this 'information about'. The conception of a haptic medium as a nested tensegrity structure has been proposed to express the obtained information realized by myofascia deformation, by its invariants and transformations. The tensegrity proposal rationalizes the relative indifference of dynamic touch to the site of mechanical contact (hand, foot, torso or probe) and the overtness of exploratory activity. It also provides a framework for dynamic touching's fractal nature, and the finding that its degree of fractality may matter to its accomplishments.


Assuntos
Mãos/fisiologia , Mecanorreceptores/fisiologia , Músculo Esquelético/fisiologia , Tato/fisiologia , Fractais , Humanos , Percepção/fisiologia
15.
J Mot Behav ; 43(4): 285-94, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-21774605

RESUMO

The authors reexamined reported effects of age, illumination, and stationary visible structure on the net center of pressure (COP) derived from dual, side-by-side force plates (J. Kinsella-Shaw, S. Harrison, C. Colon-Semenza, & M. Turvey, 2006 ) from the perspective of axial postural control. They questioned how left and right COP(x)(t), COP(y)(t), and vertically oriented ground reactive force, GRF(z)(t), coordinated during quiet standing. The Cross-recurrence Quantification (CRQ) revealed that coordination was primarily between fluctuations of similar direction, with coordination of left and right COP(y) (t) (anteroposterior fluctuations) dominant. CRQ also revealed that (a) illumination and structure affected the interlimb dynamics of older (M age = 72.2 ± 4.90 years) participants more than their younger (M age = 22.8 ± 0.83 years) counterparts, and (b) older participants exhibited greater interlimb entrainment (dynamical stability) in the presence of greater interlimb noise.


Assuntos
Envelhecimento/fisiologia , Meio Ambiente , Perna (Membro)/fisiologia , Equilíbrio Postural/fisiologia , Percepção Visual/fisiologia , Adulto , Idoso , Feminino , Humanos , Masculino , Fenômenos Fisiológicos Musculoesqueléticos , Estimulação Luminosa , Percepção Espacial
16.
J Mot Behav ; 43(2): 87-93, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-21302174

RESUMO

The haptic subsystem of dynamic touch expresses a novel form of part-whole selective perception. When wielding a nonvisible rod grasped at some intermediate point along its length, an individual can attend to and report the length of a part of the rod (e.g., the segment forward of the hand) or the length of the whole rod. Both perceptions relate to the rod's mass moments about the point of grasp but in systematically different ways. Previous demonstrations of this part-whole selectivity have been in respect to rods grasped by hand or attached to a foot. The authors demonstrated the part-whole selectivity for nonvisible rods attached to the shoulder girdle and wielded primarily by movements of the trunk with benchmark performance provided by the same rods grasped and wielded by hand. Their results suggest that part-whole selectivity is a haptic capability general to the body.


Assuntos
Desempenho Psicomotor , Ombro , Percepção de Tamanho , Percepção do Tato , Mãos , Humanos , Distribuição Aleatória , Percepção de Peso
17.
Neurosci Lett ; 490(2): 126-9, 2011 Feb 25.
Artigo em Inglês | MEDLINE | ID: mdl-21184808

RESUMO

When a person standing upright raises an arm on cue, muscles of the left and right sides of the body exhibit changes prior to and specific to the responding arm. We had standing participants perform a visual lexical decision task ("is this letter string a word?"), responding yes by raising one arm and no by raising the other arm. We recorded onset of the arm movement and onset of electromyographic activity in thigh, trunk, and shoulder muscles. We observed the expected responding arm specificity and found that the onset difference favoring word decisions was evident in similar magnitude at all measurement sites, with the difference at the levels of thigh, trunk and shoulder muscles available 225, 189, and 120 ms, respectively, prior to its manifestation at the level of arm movement. We discuss including (a) whole body reaction time along with event-related potentials in determining the decision-response, brain-body temporal relation and (b) response execution along with response initiation in investigating mental chronometry.


Assuntos
Tomada de Decisões/fisiologia , Estimulação Luminosa/métodos , Postura/fisiologia , Desempenho Psicomotor/fisiologia , Tempo de Reação/fisiologia , Braço/fisiologia , Feminino , Humanos , Masculino , Movimento/fisiologia
18.
Atten Percept Psychophys ; 72(3): 721-35, 2010 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-20348578

RESUMO

The current research distinguishes two types of attention shifts: those entailed by perceptual learning and those entailed by changing intention. In perceptual learning, participants given feedback have been shown to gradually shift attention toward the optimal (i.e., specifying) information variable for the task. A shift in variable use is also expected when intention changes, because an intention to perceive some property entails attunement to information about that property. We compared the effects of feedback and intention in a dynamic (kinesthetic) touch task by representing both as changes of locus in an information space of inertial variables. Participants wielded variously sized, unseen, rectangular parallelepipeds and made length or width judgments about them. When given feedback, participants made gradual attentional shifts toward the optimal variable, which demonstrates the education of attention. When asked to report a new property, participants made large attentional jumps to the ballpark of the optimal variable for the new property. Exploratory movements were measured on 6 participants and were found to differ as a function of intention and to change with learning.


Assuntos
Atenção , Intenção , Aprendizagem , Tato , Adolescente , Retroalimentação , Feminino , Humanos , Masculino , Adulto Jovem
19.
Cogn Syst Res ; 11(2): 148-164, 2010 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-20191086

RESUMO

We examine Dubois's (2003) distinction between weak anticipation and strong anticipation. Anticipation is weak if it arises from a model of the system via internal simulations. Anticipation is strong if it arises from the system itself via lawful regularities embedded in the system's ordinary mode of functioning. The assumption of weak anticipation dominates cognitive science and neuroscience and in particular the study of perception and action. The assumption of strong anticipation, however, seems to be required by anticipation's ubiquity. It is, for example, characteristic of homeostatic processes at the level of the organism, organs, and cells. We develop the formal distinction between strong and weak anticipation by elaboration of anticipating synchronization, a phenomenon arising from time delays in appropriately coupled dynamical systems. The elaboration is conducted in respect to (a) strictly physical systems, (b) the defining features of circadian rhythms, often viewed as paradigmatic of biological behavior based in internal models, (c) Pavlovian learning, and (d) forward models in motor control. We identify the common thread of strongly anticipatory systems and argue for its significance in furthering understanding of notions such as "internal", "model" and "prediction".

20.
J Mot Behav ; 42(1): 85-97, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-20051351

RESUMO

Upright standing is always environmentally embedded and typically co-occurs with another (suprapostural) activity. In the present study, the authors investigate how these facts affect postural dynamics in an experiment in which younger (M age = 20.23 years, SD = 2.02 years) and older (M age = 75.26 years, SD = 4.87 years) participants performed a task of detecting letters in text or maintaining gaze within a target while standing upright in a structured or nonstructured stationary environment. They extracted the coefficients of drift (indexing attractor strength) and diffusion (indexing noise strength) from the center of pressure (COP) time series in anteroposterior (AP) and mediolateral (ML) axes. COP standard deviation decreased with drift and increased with diffusion. The authors found that structure reduced AP diffusion for both groups and that letter detection reduced younger SDAP (primarily by diffusion decrease) and increased older SDML (primarily by drift decrease). For older and younger participants, ML drift was lower during letter detection. Further, in older letter detection, larger visual contrast sensitivity was associated with larger ML drift and smaller SDML, raising the hypotheses that ML sway helps information detection and reflects neurophysiological age.


Assuntos
Fatores Etários , Meio Ambiente , Postura/fisiologia , Análise e Desempenho de Tarefas , Idoso , Análise de Variância , Atenção , Sensibilidades de Contraste/fisiologia , Fixação Ocular/fisiologia , Humanos , Modelos Biológicos , Equilíbrio Postural/fisiologia , Leitura , Processos Estocásticos , Percepção Visual , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA