RESUMO
BACKGROUND: Gastric sleeve stenosis (GSS) is described in 1%-4% of patients. OBJECTIVE: To evaluate the role of endoscopy in the management of stenosis after laparoscopic sleeve gastrectomy using a standardized approach according to the characteristic of stenosis. SETTING: Retrospective, observational, single-center study on patients referred from several bariatric surgery departments to an endoscopic referral center. METHODS: We enrolled 202 patients. All patients underwent endoscopy in a fluoroscopy setting, and a systematic classification of the type, site, and length of the GSS was performed. According to the characteristics of the stenosis, patients underwent pneumatic dilatation or placement of a self-expandable metal stent or a lumen-apposed metal stent. Failure of endoscopic treatment was considered an indication for redo surgery, whereas patients with partial or complete response were followed up for 2 years. In the event of a recurrence, a different endoscopic approach was used. RESULTS: We found inflammatory strictures in 4.5% of patients, pure narrowing in 11%, and functional stenosis in 84.5%. Stenosis was in the upper tract of the stomach in 53 patients, whereas medium and distal stenosis was detected in 138 and 11 patients, respectively, and short stenosis in 194 patients. A total of 126 patients underwent pneumatic dilatation, 8 self-expandable metal stent placement, 64 lumen-apposed metal stent positioning, and 36 combined therapy. The overall rate of endoscopy success was 69%. CONCLUSION: GSS should be considered to be a chronic disease, and the endoscopic approach seems to be the most successful treatment, with a prolonged positive outcome of 69%. Characteristics of the stenosis should guide the most suitable endoscopic approach.
Assuntos
Laparoscopia , Obesidade Mórbida , Humanos , Constrição Patológica/cirurgia , Estudos Retrospectivos , Obesidade Mórbida/cirurgia , Gastrectomia , Endoscopia , Stents , Resultado do TratamentoRESUMO
BACKGROUND AND AIMS: Endoscopy is effective in management of bariatric surgery (BS) adverse events (AEs) but a comprehensive evaluation of long-term results is lacking. Our aim is to assess the effectiveness of a standardized algorithm for the treatment of BS-AE. PATIENTS AND METHODS: We retrospectively analyzed 1020 consecutive patients treated in our center from 2012 to 2020, collecting data on demographics, type of BS, complications, and endoscopic treatment. Clinical success (CS) was evaluated considering referral delay, healing time, surgery, and complications type. Logistic regression was performed to identify variables of CS. RESULTS: In the study period, we treated 339 fistulae (33.2%), 324 leaks (31.8%), 198 post-sleeve gastrectomy twist/stenosis (19.4%), 95 post-RYGB stenosis (9.3 %), 37 collections (3.6%), 15 LAGB migrations (1.5%), 7 weight regains (0.7%), and 2 hemorrhages (0.2%). Main endoscopic treatments were as follows: pigtail-stent positioning under endoscopic view for both leaks (CS 86.1%) and fistulas (CS 77.2%), or under EUS-guidance for collections (CS 88.2%); dilations and/or stent positioning for sleeve twist/stenosis (CS 80.6%) and bypass stenosis (CS 81.5%). After a median (IQR) follow-up of 18.5 months (4.29-38.68), complications rate was 1.9%. We found a 1% increased risk of redo-surgery every 10 days of delay to the first endoscopic treatment. Endoscopically treated patients had a more frequent regular diet compared to re-operated patients. CONCLUSIONS: Endoscopic treatment of BS-AEs following a standardized algorithm is safe and effective. Early endoscopic treatment is associated with an increased CS rate.
Assuntos
Cirurgia Bariátrica , Obesidade Mórbida , Algoritmos , Fístula Anastomótica/cirurgia , Cirurgia Bariátrica/efeitos adversos , Endoscopia , Gastrectomia , Humanos , Obesidade Mórbida/cirurgia , Estudos Retrospectivos , Stents , Resultado do TratamentoRESUMO
BACKGROUND: Endoscopy plays a pivotal role in the management of adverse events (AE) following bariatric surgery. Leaks, fistulae, and post-operative collection after sleeve gastrectomy (SG) may occur in up to 10% of cases. OBJECTIVES: To evaluate the efficacy and safety of endoscopic internal drainage (EID) for the management of leak, fistula, and collection following SG. SETTING: Retrospective, observational, single center study on patients referred from several bariatric surgery departments to an endoscopic referral center. METHODS: EID was used as first-line treatment for the management of leaks, fistulae, and collections. Leaks and fistulae were treated with double pigtail stent (DPS) deployment in order to guarantee internal drainage and second intention cavity obliteration. Collections were treated with endoscropic ultrasound (EUS)-guided deployment of DPS or lumen apposing metal stents. RESULTS: A total of 617 patients (83.3% female; mean age, 43.1 yr) were enrolled in the study for leak (n = 300, 48.6%), fistula (n = 285, 46.2%), and collection (n = 32, 5.2%). Median follow-up was 19.5 months. Overall clinical success was 84.7% whereas 15.3% of cases required revisional surgery after EID failure. Clinical success according to type of AE was 89.5%, 78.5%, and 90% for leak, fistula, and collection, respectively. A total of 10 of 547 (1.8%) presented a recurrence during follow-up. A total of 28 (4.5%) AE related to the endoscopic treatment occurred. At univariate logistic regression predictors of failure were: fistula (OR 2.012), combined endoscopic approach (OR 2.319), need for emergency surgery (OR 1.755), and previous endoscopic treatment (OR 4.818). CONCLUSION: Early EID for the management of leak, fistula, and post-operative collection after SG seems a safe and effective first-line approach with good long-term results.
Assuntos
Fístula Gástrica , Obesidade Mórbida , Adulto , Fístula Anastomótica/etiologia , Fístula Anastomótica/cirurgia , Drenagem , Endoscopia , Feminino , Gastrectomia/efeitos adversos , Fístula Gástrica/etiologia , Fístula Gástrica/cirurgia , Humanos , Masculino , Obesidade Mórbida/cirurgia , Estudos Retrospectivos , Stents , Resultado do TratamentoRESUMO
BACKGROUND: Management of biliary disorders in patients with altered anatomy may be challenging. Endoscopic ultrasound (EUS)-guided gastrointestinal anastomosis using a lumen-apposing metal stent (LAMS) was introduced to allow endoscopic retrograde cholangiography (ERC) in such cases. However, the appropriate stent indwelling time remains uncertain. We report long-term LAMS deployment after duodenojejunal or jejunojejunal anastomosis (EUS-DJA) to allow endoscopic reinterventions in cases of recurrences. METHODS: 11 consecutive patients underwent EUS-DJA with long-standing LAMS between January 2017 and December 2018.âOver a 12-month period, ERC treatment was carried out with multiple endoscopic sessions across the DJA. RESULTS: Technical success was 91â% (10/11) for EUS-DJA and 100â% for ERC. Four patients presented stricture recurrence at a mean of 489 days (standard deviation [SD] 31.7) after the end of ERC treatment. A novel ERC across the LAMS anastomosis was feasible in all cases. At a mean of 781 days (SD 253.1), all LAMS remained in place with no evidence of complications. CONCLUSION: Long-term LAMS placement after EUS-DJA may be feasible and safe for direct access to the excluded limb.
Assuntos
Endossonografia , Stents , Anastomose Cirúrgica/efeitos adversos , Duodeno/cirurgia , Humanos , Ultrassonografia de IntervençãoRESUMO
INTRODUCTION: Treatment of pancreato-biliary disorders after gastric bypass is challenging due to altered anatomy. Several techniques have been proposed to overcome this condition; however, none has emerged as the gold standard treatment. Furthermore, a decision-making algorithm evaluating when and why apply one technique over another is still lacking. OBJECTIVES: To describe a novel trans-gastric approach to allow endoscopic retrograde cholangiopancreatography (ERCP) in Roux-en-Y gastric bypass (RYGB) anatomy soon after prior laparoscopic cholecystectomy (LC) and to propose a decision-making algorithm for selection of the most suitable technique according a tailored approach. SETTING: Private hospital. METHODS: Between January and March 2020, patients with Roux-en-Y gastric bypass anatomy referred to our tertiary center to undergo ERCP after recent laparoscopic cholecystectomy were retrospectively evaluated. A 20 french (Fr) gastrostomy was performed during cholecystectomy. A single-stage ERCP was carried out by means of temporary trans-gastric stent deployment over a 20 Fr gastrostomy. RESULTS: A total of 5 patients (mean age 41; mean body mass index 48.3) were enrolled. ERCP was performed after an average of 2 days from surgery. Technical and clinical success was achieved in 100%. No adverse events occurred. Spontaneous closure of the gastrostomy after its bedside removal was observed in all cases. CONCLUSIONS: Our approach allows to perform a single-stage ERCP in RYGB patients, early after LC, with no need of any other re-interventions. Any surgeon facing unexpected biliary disorders, during LC, can easily perform a 20 Fr gastrostomy thus allowing the patient to undergo early ERCP without any delay.
Assuntos
Derivação Gástrica , Obesidade Mórbida , Adulto , Colangiopancreatografia Retrógrada Endoscópica , Gastrostomia , Humanos , Obesidade Mórbida/cirurgia , Estudos Retrospectivos , StentsRESUMO
BACKGROUND: Post-operative collections are a recognized source of morbidity after abdominal surgery. Percutaneous drainage is currently considered the standard treatment but not all collections are accessible using this method. Since the adoption of EUS, endoscopic transmural drainage has become an attractive option in the management of such complications. The present study aimed to assess the efficacy, safety and modalities of endoscopic transmural drainage in the treatment of post-operative collections. METHODS: Data of all patients referred to our dedicated multidisciplinary facility from 2014 to 2017 for endoscopic drainage of symptomatic post-operative collections after failure of percutaneous drainage or when it was deemed impossible, were retrospectively analyzed. RESULTS: Thirty-two patients (17 males and 15 females) with a median age of 53 years old (range 31-74) were included. Collections resulted from pancreatic (n = 10), colorectal (n = 6), bariatric (n = 5), and other type of surgery (n = 11). Collection size was less than 5 cm in diameter in 10 (31%), between 5 and 10 cm in 17 (53%) ,and more than 10 cm in 5 (16%) patients. The median time from surgery to endoscopic drainage was 38 days (range 6-360). Eight (25%) patients underwent endoscopic guided drainage whereas 24 (75%) patients underwent EUS-guided drainage. Technical success was 100% and clinical success was achieved in 30 (93.4%) after a mean follow-up of 13.5 months (1.2-24.8). Overall complication was 12.5% including four patients who bled following trans-gastric drainage treated with conservative therapy. CONCLUSIONS: The present series suggests that endoscopic transmural drainage represents an interesting alternative in the treatment of post-operative collection when percutaneous drainage is not possible or fails.
Assuntos
Ascite/terapia , Cirurgia Bariátrica , Procedimentos Cirúrgicos do Sistema Digestório , Drenagem/métodos , Endossonografia/métodos , Complicações Pós-Operatórias/terapia , Ultrassonografia de Intervenção/métodos , Adulto , Idoso , Ascite/etiologia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Resultado do TratamentoRESUMO
Background and study aims Revision of endoscopic retrograde cholangiopancreatography (ERCP) may be necessary following previous biliary endoscopic sphincterotomy for recurrent biliary symptoms related to biliary stone recurrence, cholangitis or post-biliary endoscopic sphincterotomy (bEST) papillary stenosis and cholestasis. The aim of this retrospective study was to evaluate the clinical outcome and complication rate associated with re-cut, balloon dilation and biliary metal stenting in revision ERCP. Patients and methods From January 2010 to January 2015, 139 subjects with stigma of a previous sphincterotomy required a revision ERCP (64 Men/75 Women; mean age 71 years; range 32â-â101 years). The most appropriate technique (re-cut, balloon dilation or fully covered self-expandable metal stent [FCSEMS] placement) was tailored according to underlying pathologies and anatomical features. Results Technical success was achieved in all cases (100â%). Clinical success (definitive clearance of common bile duct stones and liver test normalization) was achieved in 127 out of 139 patients (91.4â%) with a mean follow up of 12 months. 12 clinical failures occurred: 11 patients required a new ERCP after an average of 9 months meanwhile 1 patient required surgery for definite treatment. The overall complication rate was 9â% (13â/139) with 5 acute complications (intra-procedural) and 8 short-term complications (before 1 month). Group specific overall complication rates were as follow: re-cut 11.5â% (8 bleeds and 3 perforations), balloon dilation 25â% (4 mild PEP [post-ERCP pancreatitis]), FCSEMS 14.3â% (1 moderate PEP), re-cutâ+âballoon dilation and re-cutâ+âFCSEMS 0â%. A statistically significant higher risk of post-ERCP pancreatitis was highlighted in the balloon dilation group meanwhile re-cut was burdened by a higher risk of bleeding and perforation. Conclusions Revision ERCP following previous bEST is a feasible procedure enabling clinical success in most cases. Different approaches are available and must be considered according to underlying pathologies. Re-cut is burdened by a higher risk of perforation and bleeding compared to balloon dilation and SEMS meanwhile balloon dilation is associated to increased risk of PEP.
RESUMO
BACKGROUND: A large number of patients who undergo laparoscopic sleeve gastrectomy present with surgical complications. Stenosis, in particular, occurs in .7%-4% of cases. OBJECTIVES: To report our experience, results, and long-term follow-up after pneumatic dilation of late functional helix stenosis after laparoscopic sleeve gastrectomy. SETTING: Multicenter study led by an endoscopic tertiary referral center. METHODS: Thirty-five patients were dilated initially at 30 mm. Thirteen out of 35 patients underwent a second dilation up to 35 mm. Only 8 patients underwent a third pneumatic dilation up to 40 mm. The stricture was localized in the mid-body of the sleeve in 32 patients overall; 3 had narrowing adjacent to the cardia. Eleven twists formed an acute angle between the 2 segments of the stomach, whereas 24 angles were obtuse. Seven out of 35 patients presented with persistent dilated pouch above the twist. Two patients were lost to follow-up. Overall outcome at an average follow-up of 15.5 months after primary surgery (range 7-49 mo) was as follows: 12 clinical failures and 1 technical failure (40%) and 60% (20 out of 33) clinical success. CONCLUSION: Pneumatic dilation of late functional helix stricture is an effective technique for treatment of dysphagia in the majority of patients treated. Complete helix stricture, defined in function of the angle within twist, as well as the presence of a persistently dilated gastric pouch above the kinking, seems to be correlated with higher failure rates.
Assuntos
Cirurgia Bariátrica/efeitos adversos , Gastrectomia/efeitos adversos , Laparoscopia/efeitos adversos , Gastropatias/terapia , Adulto , Anastomose Cirúrgica , Constrição Patológica/terapia , Transtornos de Deglutição/etiologia , Transtornos de Deglutição/cirurgia , Dilatação/métodos , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Obesidade Mórbida/cirurgia , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/cirurgia , Retratamento , Estudos Retrospectivos , Stents , Gastropatias/etiologia , Anormalidade Torcional/etiologia , Anormalidade Torcional/cirurgia , Resultado do Tratamento , Adulto JovemRESUMO
BACKGROUND: Roux-en-Y gastric bypass (RYGB) is complicated by a leak in 0-4.3% of cases. Treatment by fully covered stents has been reported to be associated with some life-threatening complications. We report our experience of insertion of double pigtail stents. METHODS: Thirty-three patients (20M, 43 years-20/65), presenting with a leak at an average of 10 days after RYGB (4-35), were treated by double pigtail stent insertion and a nasojejunal feeding tube. Sixty percent of these patients had undergone surgical drainage prior to stenting for control of sepsis. Thirty leaks were located at the top of staple line and three at the gastro-jejunal anastomosis. At a 4-weekly follow-up, ablation or re-stenting was performed depending on status of fistula closure and patients were placed on normal diet. RESULTS: At the first follow-up, 10/33 fistulae healed, one patient presented with clinical failure (3%) and needed surgery, and 22/33were re-stented. Twenty-one out of these 22 developed a secondary sub-clinical gastro-gastric fistula and one, instead, developed complex (gastro-gastric, gastro-colic) fistula. All (22) primary fistulae healed following four more weeks of treatment. Average treatment duration was of 61 days (28-99). Thirty-two patients (97%) at a follow-up of 1-33 months are asymptomatic. CONCLUSIONS: Leaks following RYGB can be successfully and safely managed by double pigtail stents. Upper gastric staple line leaks are responsible for the formation of a secondary sub-clinic gastro-gastric fistula which needs no additional treatment.
Assuntos
Fístula Anastomótica , Derivação Gástrica/efeitos adversos , Fístula Gástrica , Reoperação , Stents , Adulto , Fístula Anastomótica/etiologia , Fístula Anastomótica/cirurgia , Feminino , Fístula Gástrica/etiologia , Fístula Gástrica/cirurgia , Humanos , Masculino , Reoperação/educação , Reoperação/instrumentação , Reoperação/métodos , Gravação em VídeoRESUMO
BACKGROUND: The Over-The-Scope Clip (OTSC®, Ovesco Endoscopy GmbH, Tübingen, Germany) is an innovative clipping device that provides a strong tissue grasp and compression without provoking ischemia or laceration. In this retrospective study we evaluated immediate and long-term success rates of OTSC deployment in various pathologies of the gastrointestinal (GI) tract. METHODS: A total of 45 patients (35 female, 10 male) with an average age of 56 years old (range, 24-90 years) were treated with an OTSC for GI defects resulting from a diagnostic or interventional endoscopic procedure (acute setting group) or for fistula following abdominal surgery (chronic setting group). All procedures were performed with CO2 insufflation. RESULTS: From January 2012 to December 2015 a total of 51 OTSCs were delivered in 45 patients for different kinds of GI defects. Technical success was always achieved in the acute setting group with an excellent clip adherence and a clinical long-term success rate of 100% (15/15). Meanwhile, considering the chronic setting group, technical success was achieved in 50% of patients with a long-term clinical success of 37% (11/30); two minor complications occurred. A total of three patients died due to causes not directly related to clip deployment. Overall clinical success rate was achieved in 58% cases (26/45 patients). A mean follow-up period of 17 months was accomplished (range, 1-36 months). CONCLUSION: OTSC deployment is an effective and minimally-invasive procedure for GI defects in acute settings. It avoids emergency surgical repair and it allows, in most cases, completion of the primary endoscopic procedure. OTSC should be incorporated as an essential technique of today's modern endoscopic armamentarium in the management of GI defects in acute settings. OTSCs were less effective in cases of chronic defects.
RESUMO
BACKGROUND AND STUDY AIMS: Duodenal obstruction may prevent performance of endoscopic retrograde cholangiopancreatography (ERCP). Percutaneous transhepatic biliary drainage (PTBD) or Endoscopic ultrasonograhy-guided biliary access (EUS-BD) are alternative treatments but are associated with a higher morbidity and mortality rate. The aim of the study is to report overall technical success rate and clinical outcome with deployment of temporary fully or partially covered self-expanding duodenal stent (pc/fcSEMS) as a bridge to ERCP in case of inaccessible papilla due to duodenal strictures. PATIENTS AND METHODS: This retrospective study included 66 consecutive patients presenting with a duodenal stricture impeding the ability to perform an ERCP. Provisional duodenal stenting was performed as a bridge to ERCP. A second endoscopic session was performed to remove the provisional stent and to perform an ERCP. Afterward, a permanent duodenal stent was delivered if necessary. RESULTS: Sixty-six duodenal stents (17 pcSEMS and 49 fcSEMS) were delivered with a median indwelling time of 3.15 (1â-â7) days. Two migrations occurred in the pcSEMS group, 1 of which required lower endoscopy for retrieval. No other procedure-related complications were observed. At second endoscopy a successful ERCP was performed in 56 patients (85â%); 10 patients (15â%) with endoscopic failure underwent PTBD or EUS-BD. Forty patients needed permanent duodenal stenting. CONCLUSIONS: Provisional removable covered duodenal stenting as a bridge to ERCP for duodenal obstruction is safe procedure and in most cases allows successful performance of therapeutic ERCP. This technique could be a sound option as a step up approach before referring such cases for more complex techniques such as EUS-BD or PTBD.
RESUMO
BACKGROUND AND STUDY AIMS: Leaks following gastrointestinal surgery are a dreadful complication burdened by high morbidity and not irrelevant mortality. Endoscopic internal drainage (EID) has showed optimal results in the treatment of leaks following bariatric surgery. We report our experience with EID as first-line treatment for fistulas following surgery along all gastrointestinal tract.
RESUMO
OBJECTIVES: Several endoscopic techniques have been proposed for the management of post-sphincterotomy bleeding. Lately, self-expandable metal stents deployment has gained popularity especially as a rescue therapy when other endoscopic techniques fail. METHODS-RESULTS: We report the case report of a massive post-sphincterotomy bleeding in a patient with a self-expandable metal stent in the biliary tree. Despite the presence of a correctly positioned self-expandable metal stent, a new endoscopic session was required to control the bleeding. CONCLUSIONS: Self-expandable metal stent may be useful to manage post-endoscopic sphincterotomy bleeding. However, up to now there is no specifically designed self-expandable metal stent for such complication. Large new designed self-expandable metal stent may be a useful tool for biliary endoscopist.
Assuntos
Fístula Gástrica/terapia , Falha de Prótese/efeitos adversos , Baço/lesões , Stents/efeitos adversos , Adulto , Remoção de Dispositivo , Drenagem , Endoscopia Gastrointestinal , Gastrectomia/efeitos adversos , Fístula Gástrica/etiologia , Humanos , Masculino , Radiografia , Baço/diagnóstico por imagemRESUMO
BACKGROUND: Self-expandable metal stent (SEMS) placement is a minimally invasive treatment for palliation of malignant colorectal strictures and as a bridge to surgery. However, the use of SEMS for benign colorectal diseases is controversial. The purpose of this retrospective study is to evaluate the efficacy and safety of fully covered SEMS (FCSEMS) placement in postsurgical colorectal diseases. METHODS: From 2008 to 2014, 29 patients with 32 FCSEMS deployment procedures were evaluated. The indications for stent placement were: 17 anastomotic strictures (3/17 presented complete closure of the anastomosis); four anastomotic leaks; seven strictures associated with anastomotic leak; and one rectum-vagina fistula. RESULTS: Clinical success was achieved in 18 out of 29 patients (62.1%) being symptom-free at an average of 19 months. In the remaining 11 patients (37.9%), a different treatment was needed: four patients required multiple endoscopic dilations, 4 patients colostomy confection, one patient definitive ileostomy and three patients revisional surgery. The FCSEMS were kept in place for a mean period of 34 (range: 6-65) days. Major complications occurred in 12 out of 29 patients (41.4%) and consisted of stent migration. Minor complications included two cases of transient fever, eight cases of abdominal or rectal pain, and one case of tenesmus. CONCLUSION: FCSEMS are considered a possible therapeutic option for treatment of postsurgical strictures and leaks. However, their efficacy in guaranteeing long-term anastomotic patency and leak closure is moderate. A major complication is migration. The use of FCSEMS for colonic postsurgical pathologies should be carefully evaluated for each patient.