1.
Epilepsia ; 2024 Aug 14.
Artigo em Inglês | MEDLINE | ID: mdl-39141002

RESUMO

OBJECTIVE: The automated interpretation of clinical electroencephalograms (EEGs) using artificial intelligence (AI) holds the potential to bridge the treatment gap in resource-limited settings and reduce the workload at specialized centers. However, to facilitate broad clinical implementation, it is essential to establish generalizability across diverse patient populations and equipment. We assessed whether SCORE-AI demonstrates diagnostic accuracy comparable to that of experts when applied to a geographically different patient population, recorded with distinct EEG equipment and technical settings. METHODS: We assessed the diagnostic accuracy of a "fixed-and-frozen" AI model, using an independent dataset and external gold standard, and benchmarked it against three experts blinded to all other data. The dataset comprised 50% normal and 50% abnormal routine EEGs, equally distributed among the four major classes of EEG abnormalities (focal epileptiform, generalized epileptiform, focal nonepileptiform, and diffuse nonepileptiform). To assess diagnostic accuracy, we computed sensitivity, specificity, and accuracy of the AI model and the experts against the external gold standard. RESULTS: We analyzed EEGs from 104 patients (64 females, median age = 38.6 [range = 16-91] years). SCORE-AI performed equally well compared to the experts, with an overall accuracy of 92% (95% confidence interval [CI] = 90%-94%) versus 94% (95% CI = 92%-96%). There was no significant difference between SCORE-AI and the experts for any metric or category. SCORE-AI performed well independently of the vigilance state (false classification during awake: 5/41 [12.2%], false classification during sleep: 2/11 [18.2%]; p = .63) and normal variants (false classification in presence of normal variants: 4/14 [28.6%], false classification in absence of normal variants: 3/38 [7.9%]; p = .07). SIGNIFICANCE: SCORE-AI achieved diagnostic performance equal to human experts in an EEG dataset independent of the development dataset, in a geographically distinct patient population, recorded with different equipment and technical settings than the development dataset.

2.
JAMA Neurol ; 80(8): 805-812, 2023 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-37338864

RESUMO

Importance: Electroencephalograms (EEGs) are a fundamental evaluation in neurology but require special expertise unavailable in many regions of the world. Artificial intelligence (AI) has a potential for addressing these unmet needs. Previous AI models address only limited aspects of EEG interpretation such as distinguishing abnormal from normal or identifying epileptiform activity. A comprehensive, fully automated interpretation of routine EEG based on AI suitable for clinical practice is needed. Objective: To develop and validate an AI model (Standardized Computer-based Organized Reporting of EEG-Artificial Intelligence [SCORE-AI]) with the ability to distinguish abnormal from normal EEG recordings and to classify abnormal EEG recordings into categories relevant for clinical decision-making: epileptiform-focal, epileptiform-generalized, nonepileptiform-focal, and nonepileptiform-diffuse. Design, Setting, and Participants: In this multicenter diagnostic accuracy study, a convolutional neural network model, SCORE-AI, was developed and validated using EEGs recorded between 2014 and 2020. Data were analyzed from January 17, 2022, until November 14, 2022. A total of 30 493 recordings of patients referred for EEG were included into the development data set annotated by 17 experts. Patients aged more than 3 months and not critically ill were eligible. The SCORE-AI was validated using 3 independent test data sets: a multicenter data set of 100 representative EEGs evaluated by 11 experts, a single-center data set of 9785 EEGs evaluated by 14 experts, and for benchmarking with previously published AI models, a data set of 60 EEGs with external reference standard. No patients who met eligibility criteria were excluded. Main Outcomes and Measures: Diagnostic accuracy, sensitivity, and specificity compared with the experts and the external reference standard of patients' habitual clinical episodes obtained during video-EEG recording. Results: The characteristics of the EEG data sets include development data set (N = 30 493; 14 980 men; median age, 25.3 years [95% CI, 1.3-76.2 years]), multicenter test data set (N = 100; 61 men, median age, 25.8 years [95% CI, 4.1-85.5 years]), single-center test data set (N = 9785; 5168 men; median age, 35.4 years [95% CI, 0.6-87.4 years]), and test data set with external reference standard (N = 60; 27 men; median age, 36 years [95% CI, 3-75 years]). The SCORE-AI achieved high accuracy, with an area under the receiver operating characteristic curve between 0.89 and 0.96 for the different categories of EEG abnormalities, and performance similar to human experts. Benchmarking against 3 previously published AI models was limited to comparing detection of epileptiform abnormalities. The accuracy of SCORE-AI (88.3%; 95% CI, 79.2%-94.9%) was significantly higher than the 3 previously published models (P < .001) and similar to human experts. Conclusions and Relevance: In this study, SCORE-AI achieved human expert level performance in fully automated interpretation of routine EEGs. Application of SCORE-AI may improve diagnosis and patient care in underserved areas and improve efficiency and consistency in specialized epilepsy centers.


Assuntos
Inteligência Artificial , Epilepsia , Masculino , Humanos , Adulto , Epilepsia/diagnóstico , Eletroencefalografia , Redes Neurais de Computação , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA