Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Access Microbiol ; 5(11)2023.
Artigo em Inglês | MEDLINE | ID: mdl-38074112

RESUMO

The diagnosis of infective endophthalmitis is supported by microbiological work-up. Rapid work-up is critical to confirm clinical suspicion and appropriate antimicrobial therapy. We report the novel use of an automated liquid culture processing system (FAST system, Qvella, ON, Canada) in a vitreous fluid culture. A 59-year-old patient with post-operative endophthalmitis presented with acute right eye pain and blurred vision. Vitreous fluid collected for microbiology culture was of limited quantity and only inoculated to thioglycolate broth. The broth recovered beta-haemolytic, group G Streptococcus dysgalactiae susceptible to penicillin and vancomycin. Experimental application of the FAST system to purify the organism from broth culture yielded the same identification and susceptibility test results but 1 day sooner. Despite prompt treatment with appropriate antibiotics, including vancomycin and ceftazidime, disease progressed rapidly and required enucleation to achieve a stable therapeutic outcome. Use of automated processing of monomicrobial broth cultures has thus far focused on positive blood culture broths, but could potentially include other liquid-based cultures such as for sterile body fluids of critical nature.

2.
Microorganisms ; 10(10)2022 Oct 20.
Artigo em Inglês | MEDLINE | ID: mdl-36296352

RESUMO

Bloodstream infections are a leading cause of morbidity and mortality. The rapid diagnostic testing of positive blood cultures (PBCs) shortens times to effective therapy and the de-escalation of broad-spectrum empiric therapy. This is the first study examining the Qvella FASTTM System for the rapid (~20 min) purification of microorganisms directly from PBCs using BacT/Alert® FA/FAN bottles in the bioMérieux Virtuo instrument. We compared the performance of the FASTTM System Liquid ColonyTM (LC), for immediate downstream ID and phenotypic AST, to standard workflow involving colonies obtained by overnight subculture. The LC yielded a concordant species ID by VITEK MS in 121/138 (87.7%) samples, identifying 32 different Gram-positive and Gram-negative species with 3/123 (2.6%) discordances. Compared to standard workflow, direct AST of the LC using VITEK® 2 yielded 98.4% categorical agreement and 98.0% essential agreement. Very major error, major error, and minor error rates were 1.0%, 0.0%, and 1.8%, respectively, for Gram-negative organisms; and 1.9%, 0.2%, and 1.2%, respectively, for Gram-positive organisms. The median times from positive blood culture flag to results by FASTTM System for ID and AST were 7.8 h and 15.7 h, respectively, versus 22.4 h and 36.6 h for standard workflow, respectively. In conclusion, the FASTTM System provides reliable results for direct ID and AST from PBCs with significantly decreased turnaround times.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA