Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Polymers (Basel) ; 13(6)2021 Mar 22.
Artigo em Inglês | MEDLINE | ID: mdl-33809870

RESUMO

This paper describes a newly developed testing method for determination of the adhesivity of a film sintered from thermoplastic powder. This method is based on the modified EN 15337 standard. Application of this method enables an effective development of thermoplastic composites with enhanced adhesion between reinforcement and matrix and/or high-quality joints between plastics and dissimilar materials. The proposed method was successfully tested on a series of polyethylene powders treated in the oxygen atmosphere for 0-1200 s. Adhesion to metal and glass substrates in dependence on treatment conditions is described along with powder wettability and X-ray photoelectron spectroscopy analysis. The results show an increase in adhesion to metal by 580% and to glass by 1670% for the longest treatment time, compared to a nontreated powder. Sintering of treated powders revealed a strong influence of treatment time on the melting process. The XPS analysis confirmed the formation of new oxygen groups (C-O, C=O, O-C=O). The method reveals a specific behavior of powders based on treatment conditions, which is crucial for the optimization of plasma treatment for the improved adhesion, applicability of polymer powders, and a development of composite materials.

2.
BMC Musculoskelet Disord ; 15: 109, 2014 Mar 28.
Artigo em Inglês | MEDLINE | ID: mdl-24678698

RESUMO

BACKGROUND: At present time the number of implantations of joint replacements as well as their revisions increases. Higher demands are required on the quality and longevity of implants. The aim of this work was to determine the degree of oxidative degradation and the amount of free/residual radicals in selected ultra-high molecular weight polyethylene (UHMWPE) components of the joint replacements and demonstrate that the measured values are closely connected with quality and lifetime of the polymer components. METHODS: We tested both new (4 samples) and explanted (4 samples) UHMWPE polymers for total joint replacements. The samples were characterized by infrared spectroscopy (IR), electron spin resonance (ESR) and microhardness (MH) test. The IR measurements yielded the values of oxidation index and trans-vinylene index. The ESR measurements gave the free radicals concentration. RESULTS: In the group of new polyethylene components, we found oxidation index values ranging from 0.00-0.03 to 0.24. The trans-vinylene index values ranged from 0.044 to 0.080. The value of free radical concentration was zero in virgin and also in sample of Beznoska Company and non-zero in the other samples. In the group of explanted components, the measured values were associated with their history, micromechanical properties and performance in vivo. CONCLUSIONS: We demonstrated that measuring of oxidative damage may help the orthopaedic surgeon in estimating the quality of UHMWPE replacement component and thus radically to avoid early joint replacement failure due to worse polyethylene quality.


Assuntos
Materiais Biocompatíveis/química , Prótese de Quadril , Prótese do Joelho , Polietilenos/química , Cristalização , Espectroscopia de Ressonância de Spin Eletrônica , Radicais Livres/análise , Dureza , Humanos , Teste de Materiais , Oxirredução , Falha de Prótese , Reoperação , Espectrofotometria Infravermelho
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA