Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
1.
Acta Neurochir (Wien) ; 165(7): 1781-1790, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37014451

RESUMO

BACKGROUND: Classically, the torcular Herophili is described as the symmetric junction between the superior sagittal sinus (SSS), transverse sinuses (TSs), and straight sinus (SS). However, finding this pattern in practice is not standard. Anatomical variations are common, and different drainage patterns should be expected. Existing literature proposes highly detailed descriptions and classifications of this region. Still, a simplified and practical categorization is not available. METHODS: We present an anatomical finding of the torcular Herophili discovered on a cadaveric dissection. Then, we conducted a retrospective study examining the 100 most recent cranial magnetic resonance venographies (MRVs) from the Mayo Clinic, labeling them with a new proposed dural sinus classification system. Images were initially classified by two authors and further validated by a board-certified neurosurgeon and a board-certified neuroradiologist from our institution. To measure consistency in image identification, two additional international neurosurgeons were asked to classify a subset of the same MRV images, and their answers were compared. RESULTS: Of the MRV cohort, 33 patients were male and 67 were female. Their ages ranged from 18 to 86 years, with a mean of 47.35 years and a median of 49 years. Upon examination, 53 patients presented as confluent (53%), 9 as SSS divergent (9%), 25 as SS divergent (25%), 11 as circular (11%), and 2 as trifurcated (2%). The inter-rater reliability ranked very good; agreement between the two neurosurgeons was 83% (κ = 0.830, p < 0.0005). CONCLUSION: The confluence of the venous sinuses is a highly variable anatomical area that is rarely evaluated with neuroimaging before surgery. The classic textbook configuration is not the rule. Using a simplified classification system may increase awareness and hopefully patient safety by preparing the physician for anatomical variations that they will encounter in a surgical or clinical scenario.


Assuntos
Cavidades Cranianas , Seios Transversos , Humanos , Masculino , Feminino , Adolescente , Adulto Jovem , Adulto , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Estudos Retrospectivos , Reprodutibilidade dos Testes , Cavidades Cranianas/diagnóstico por imagem , Seios Transversos/diagnóstico por imagem , Seios Transversos/anatomia & histologia , Seio Sagital Superior/diagnóstico por imagem
2.
Cureus ; 14(5): e25448, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-35663684

RESUMO

Background Minimally invasive lateral lumbar interbody fusion (LLIF) offers advantages over traditional approaches, providing indirect decompression of neural elements and deformity correction while avoiding many challenges and risks of anterior and posterior approaches. Mastering this technique requires a specialized team, advanced equipment, and sufficient case exposure. Current training is limited to the classic educational model, and alternative training methods such as cadaver labs can be inconvenient, inaccessible, expensive, and incompatible with intraoperative neuromonitoring (IONM) systems. Objective The aim of this study was to create a proof-of-concept, low-cost, fully synthetic lateral lumbar surgical simulator and to increase awareness of the lack of current training alternatives. Methods Standard engineering design and expert interviews of attending neurosurgeons, nurses, engineers, and medical device representatives (n=20) were utilized to determine key elements for the simulator, physical characteristics of the components, and translational strategy. Physical and radiographic testing was performed on multiple thermoplastics to determine appropriateness for inclusion in the simulator. For evaluation of the concept, a descriptive slide deck and questionnaire were sent to 15 U.S. and 15 international surgeons who perform LLIF. Results The lateral access training model (LATM) features the following three components: torso casing, spine module, and IONM feature. This model utilizes operable ABS (acrylonitrile butadiene styrene) 3D-printed lumbar vertebrae, verified for anatomical accuracy and compatibility with fluoroscopy. Additionally, a novel neuromonitoring simulation algorithm was developed to train junior residents on neurological complications. To further highlight the need for lateral training models, 30/30 polled surgeons felt that this simulator has value for the field, 29/30 noted that they would have used the LATM if they had access during training, and 30/30 responded that they would encourage trainees to practice on the LATM. Conclusion The LATM is a first step to provide reliable and inexpensive basic lateral lumbar spine training. While this model is lacking some anatomical features, our simulator offers novel training elements for lateral lumbar transpsoas approaches, which lay the foundation for future models to be built. The need for this training exists, and current gaps in the approach to learning these complex techniques need to be filled due to the inconvenience, cost, and impracticability of standard cadaveric models.

3.
Oper Neurosurg (Hagerstown) ; 21(6): 523-532, 2021 11 15.
Artigo em Inglês | MEDLINE | ID: mdl-34561704

RESUMO

BACKGROUND: Brain mapping is the most reliable intraoperative tool for identifying surrounding functional cortical and subcortical brain parenchyma. Brain mapping procedures are nuanced and require a multidisciplinary team and a well-trained neurosurgeon. Current training methodology involves real-time observation and operation, without widely available surgical simulation. OBJECTIVE: To develop a patient-specific, anatomically accurate, and electrically responsive biomimetic 3D-printed model for simulating brain mapping. METHODS: Imaging data were converted into a 2-piece inverse 3D-rendered polyvinyl acetate shell forming an anatomically accurate brain mold. Functional and diffusion tensor imaging data were used to guide wire placement to approximate the projection fibers from the arm and leg areas in the motor homunculus. Electrical parameters were generated, and data were collected and processed to differentiate between the 2 tracts. For validation, the relationship between the electrical signal and the distance between the probe and the tract was quantified. Neurosurgeons and trainees were interviewed to assess the validity of the model. RESULTS: Material testing of the brain component showed an elasticity modulus of 55 kPa (compared to 140 kPa of cadaveric brain), closely resembling the tactile feedback a live brain. The simulator's electrical properties approximated that of a live brain with a voltage-to-distance correlation coefficient of r2 = 0.86. Following 32 neurosurgeon interviews, ∼96% considered the model to be useful for training. CONCLUSION: The realistic neural properties of the simulator greatly improve representation of a live surgical environment. This proof-of-concept model can be further developed to contain more complicated tractography, blood and cerebrospinal fluid circulation, and more in-depth feedback mechanisms.


Assuntos
Imagem de Tensor de Difusão , Procedimentos Neurocirúrgicos , Mapeamento Encefálico/métodos , Imagem de Tensor de Difusão/métodos , Humanos , Imageamento por Ressonância Magnética/métodos , Procedimentos Neurocirúrgicos/métodos , Impressão Tridimensional
4.
Oper Neurosurg (Hagerstown) ; 21(4): E355-E356, 2021 09 15.
Artigo em Inglês | MEDLINE | ID: mdl-34245154

RESUMO

Neurosurgical training is being challenged by rigorous work-hour restrictions and the COVID-19 pandemic.1 Now, more than ever, surgical simulation plays a pivotal role in resident education and psychomotor skill development. Three-dimensional (3D) printing technologies enable the construction of inexpensive, patient-specific, anatomically accurate physical models for a more convenient and realistic simulation of complex skull base approaches in a safe environment.2 All stages of the surgical procedure can be simulated, from positioning and exposure to deep microdissection, which has an unparalleled educational value. The complex approach-specific anatomy, narrow working angles, and pathoanatomic relationships can be readily explored from the surgeon's perspective or point of view.2,3 Furthermore, different thermoplastic polymers can be utilized to replicate the visual and tactile feedback of bone (cortical/cancellous), neurological, and vascular tissues.4 Retrosigmoid craniectomies are widely used in neurosurgery with various applications, including microvascular decompressions in patients with trigeminal neuralgia.5-7 Removal of the suprameatal tubercle (SMT) extends the retrosigmoid approach superiorly to the middle fossa and Meckel's cave, and anteriorly to the clivus.8,9 This maneuver may be necessary in patients with prominent SMTs obstructing the view of the trigeminal nerve and in patients with a more anterosuperior neurovascular conflict. This video illustrates a microsurgical training tool for learning and honing the technique of retrosigmoid craniectomy and suprameatal drilling using an affordable (29.00 USD) biomimetic 3D-printed simulator that closely recapitulates not only the anatomy but also the tactile feedback of drilling and manipulating neurological tissues (see Table and Graph 1; minute 07:11) as it happens at the time of surgery.

5.
World Neurosurg ; 143: e51-e59, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32585384

RESUMO

BACKGROUND: Pedicle screw placement is the most common method of fixation in the thoracic spine. Use of the "superior facet rule" allows the operator to locate the borders of the pedicle reliably using posterior landmarks alone. This study investigated the ability of 3-dimensionally (3D)-printed thoracic vertebrae, made from combined thermoplastic polymers, to demonstrate pedicle screw cannulation accurately using the superior facet as a reliable landmark. METHODS: An anonymized computed tomography scan of the thoracic spine was obtained. The T1-T12 thoracic vertebrae were anatomically segmented and 3D-printed. The pedicle diameters and distance from the midpoint of the superior facet to the ventral lamina were recorded. A total of 120 thoracic pedicles in 60 thoracic vertebral models were instrumented using a freehand technique based only on posterior landmarks. The vertebral models were then coronally cut and examined for medial or lateral violations of the pedicle after screw placement. RESULTS: A total of 120 pedicle screws were placed successfully within the 3D-printed thoracic vertebral models. Average measurements fell within 1 standard deviation of previous population studies. There were no pedicle wall violations using standard posterior element landmarks for instrumentation. There were 3 lateral violations of the vertebral body wall during screw placement, all attributable to the insertion technique. CONCLUSIONS: 3D-printed thoracic vertebral models using combined thermoplastic polymers can accurately demonstrate the anatomical ultrastructure and posterior element relationships of the superior facet rule for safe thoracic pedicle screw placement. This method of vertebral model prototyping could prove useful for surgical education and demonstrating spinal anatomy.


Assuntos
Pontos de Referência Anatômicos , Modelos Anatômicos , Parafusos Pediculares , Impressão Tridimensional , Fusão Vertebral/métodos , Vértebras Torácicas/cirurgia , Osso Esponjoso , Osso Cortical , Humanos , Tomografia Computadorizada por Raios X , Articulação Zigapofisária
6.
Cureus ; 12(3): e7466, 2020 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-32351845

RESUMO

A common cause of cervical radiculopathy from degenerative foraminal stenosis is severe uncovertebral hypertrophy. It is difficult to accomplish complete foraminal decompression in these cases with posterior techniques without the removal of a large portion of the facet joint. Total removal of the uncovertebral joint from an anterior approach allows for complete decompression of the exiting cervical nerve root and has been shown to be a safe technique. In this surgical video and technical report, we demonstrate the surgical anatomy and operative technique of a two-level anterior uncinatectomy during anterior discectomy and fusion (ACDF) for recurrent cervical radiculopathy after a previous multi-level posterior foraminotomy. The patient is a 67-year-old male with a progressive left arm and neck pain with radiographic, clinical, and electrophysiologic diagnostic evidence of active C6 and C7 radiculopathies from degenerative foraminal stenosis at the C5-6 and C6-7 levels. Posterior foraminotomies had been performed without significant improvement in his radicular pain. A repeat MRI demonstrated lateral foraminal stenosis from severe uncovertebral joint hypertrophy at the C5-6 and C6-7 levels. After acquiring informed consent from the patient, an anterior approach was performed with complete removal of the uncovertebral joints at both levels with discectomy and fusion. Postoperatively, the patient had complete resolution of his radicular pain and remained pain-free at the latest follow-up. Complete uncinatectomy and ACDF is an effective technique for complete foraminal decompression in cases of refractory radiculopathy and neck pain after unsuccessful posterior decompression.

7.
World Neurosurg ; 140: 173-179, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32360916

RESUMO

BACKGROUND: Three-dimensional (3D) printing is a powerful tool for replicating patient-specific anatomic features for education and surgical planning. The advent of "desktop" 3D printing has created a cost-effective and widely available means for institutions with limited resources to implement a 3D-printing workflow into their clinical applications. The ability to physically manipulate the desired components of a "dynamic" 3D-printed model provides an additional dimension of anatomic understanding. There is currently a gap in the literature describing a cost-effective and time-efficient means of creating dynamic brain tumor 3D-printed models. METHODS: Using free, open-access software (3D Slicer) for patient imaging to Standard Tessellation Language file conversion, as well as open access Standard Tessellation Language editing software (Meshmixer), both intraaxial and extraaxial brain tumor models of patient-specific pathology are created. RESULTS: A step-by-step methodology and demonstration of the software manipulation techniques required for creating cost-effective, multidimensional brain tumor models for patient education and surgical planning are exhibited using a detailed written guide, images, and a video display. CONCLUSIONS: In this technical note, we describe in detail the specific functions of free, open-access software and desktop 3D printing techniques to create dynamic and patient-specific brain tumor models for education and surgical planning.


Assuntos
Neoplasias Encefálicas/patologia , Imageamento Tridimensional/economia , Modelos Neurológicos , Impressão Tridimensional/economia , Análise Custo-Benefício , Humanos , Imageamento Tridimensional/métodos
8.
Cureus ; 12(4): e7738, 2020 Apr 20.
Artigo em Inglês | MEDLINE | ID: mdl-32455058

RESUMO

Background The recent COVID-19 pandemic has demonstrated the need for innovation in cost-effective and easily produced surgical simulations for trainee education that are not limited by physical confines of location. This can be accomplished with the use of desktop three-dimensional (3D) printing technology. This study describes the creation of a low-cost and open-access simulation for anatomical learning and pedicle screw placement in the lumbar spine, which is termed the SpineBox. Materials and methods An anonymized CT scan of the lumbar spine was obtained and converted into 3D software files of the L1-L5 vertebral bodies. A computer-assisted design (CAD) software was used to assemble the vertebral models into a simulator unit in anatomical order to produce an easily prototyped simulator. The printed simulator was layered with foam in order to replicate soft tissue structures. The models were instrumented with pedicle screws using standard operative technique and examined under fluoroscopy. Results Ten SpineBoxes were created using a single desktop 3D printer, with accurate replication of the cortico-cancellous interface using previously validated techniques. The models were able to be instrumented with pedicle screws successfully and demonstrated quality representation of bony structures under fluoroscopy. The total cost of model production was under $10. Conclusion The SpineBox represents the first open-access simulator for the instruction of spinal anatomy and pedicle screw placement. This study aims to provide institutions across the world with an economical and feasible means of spine surgical simulation for neurosurgical trainees and to encourage other rapid prototyping laboratories to investigate innovative means of creating educational surgical platforms in the modern era.

9.
Cureus ; 12(3): e7225, 2020 Mar 09.
Artigo em Inglês | MEDLINE | ID: mdl-32274283

RESUMO

Unstable traumatic cervical spine fracture is a commonly encountered neurosurgical issue. Concomitant vertebral artery injuries present a challenge in surgical decision-making regarding the timing and order of surgical intervention with respect to endovascular intervention and internal fixation of the unstable fracture. Currently, there are no studies that have specifically examined stroke rate or outcomes for patients who have vertebral artery injuries and unstable cervical spine fractures with respect to temporal treatment course. The purpose of this paper is to review the current evidence for the standards of diagnosis and management of vertebral artery injuries with coinciding unstable cervical spine injuries and propose an evidence-based algorithm for workup and treatment.

10.
Cureus ; 12(2): e7081, 2020 Feb 23.
Artigo em Inglês | MEDLINE | ID: mdl-32226682

RESUMO

Three-dimensional (3D) printing has revolutionized medical training and patient care. Clinically it is used for patient-specific anatomical modeling with respect to surgical procedures. 3D printing is heavily implemented for simulation to provide a useful tool for anatomical knowledge and surgical techniques. Fused deposition modeling (FDM) is a commonly utilized method of 3D printing anatomical models due to its cost-effectiveness. A potential disadvantage of FDM 3D printing complex anatomical shapes is the limitations of the modeling system in providing accurate representations of multifaceted ultrastructure, such as the facets of the lumbar spine. In order to utilize FDM 3D printing methods in an efficient manner, the pre-printing G-code assembly must be oriented according to the anatomical nature of the print. This article describes the approach that our institution's 3D printing laboratory has used to manipulate models' printing angles in regard to the print bed and nozzle, according to anatomical properties, thus creating quality and cost-effective anatomical spine models for education and procedural simulation.

11.
Clin Anat ; 33(6): 920-926, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32239547

RESUMO

Cervical radiculopathy from uncovertebral joint (UVJ) hypertrophy and nerve root compression often occurs anterior and lateral within the cervical intervertebral foramen, presenting a challenge for complete decompression through anterior cervical approaches owing to the intimate association with the vertebral artery and associated venous plexus. Complete uncinatectomy during anterior cervical discectomy and fusion (ACDF) is a controversial topic, many surgeons relying on indirect nerve root decompression from restoration of disc space height. However, in cases of severe UVJ hypertrophy, indirect decompression does not adequately address the underlying pathophysiology of anterolateral foraminal stenosis. Previous reports in the literature have described techniques involving extensive dissection of the cervical transverse process and lateral uncinate process (UP) in order to identify the vertebral artery for safe removal of the UP. Recent anatomical investigations have detailed the microanatomical organization of the fibroligamentous complex surrounding the UP and neurovascular structures. The use of the natural planes formed from the encapsulation of these connective tissue layers provides a safe passage for lateral UP dissection during anterior cervical approaches. This can be performed from within the disc space during ACDF to avoid extensive lateral dissection. In this article, we present our 10-year experience using an anatomy-based microsurgical technique for safe and complete removal of the UP during ACDF for cervical radiculopathy caused by UVJ hypertrophy.


Assuntos
Descompressão Cirúrgica/métodos , Discotomia/métodos , Microcirurgia/métodos , Radiculopatia/cirurgia , Fusão Vertebral/métodos , Articulação Zigapofisária/cirurgia , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA