Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Sci Rep ; 8(1): 9208, 2018 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-29907749

RESUMO

We present the Focus-Induced Photoresponse (FIP) technique, a novel approach to optical distance measurement. It takes advantage of a universally-observed phenomenon in photodetector devices, an irradiance-dependent responsivity. This means that the output from a sensor is not only dependent on the total flux of incident photons, but also on the size of the area in which they fall. If probe light from an object is cast on the detector through a lens, the sensor response depends on how far in or out of focus the object is. We call this the FIP effect. Here we demonstrate how to use the FIP effect to measure the distance to that object. We show that the FIP technique works with different sensor types and materials, as well as visible and near infrared light. The FIP technique operates on a working principle, which is fundamentally different from all established distance measurement methods and hence offers a way to overcome some of their limitations. FIP enables fast optical distance measurements with a simple single-pixel detector layout and minimal computational power. It allows for measurements that are robust to ambient light even outside the wavelength range accessible with silicon.

2.
Cytometry A ; 85(9): 746-55, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-24938222

RESUMO

Microfluidic flow cytometers are highly interesting candidates for biomedical point-of-care applications. However, the sensitivity, reliability, and throughput of these systems must be improved to provide the full functionality of established flow cytometric systems. One proposed method to improve fluorescence detection systems is to use spatial modulation techniques. We derive the noise-related statistics and calculate the coefficient of variation for a detection system with and without spatial modulation. We measure the noise properties of a nonmodulated microfluidic fluorescence particle detection system and analyze the possible performance gains using spatial modulation.


Assuntos
Citometria de Fluxo/métodos , Técnicas Analíticas Microfluídicas/métodos , Microfluídica/métodos , Fluorescência , Razão Sinal-Ruído
3.
Opt Express ; 21(24): 29921-6, 2013 Dec 02.
Artigo em Inglês | MEDLINE | ID: mdl-24514543

RESUMO

We demonstrate a method for the combination of UV-lithography and direct laser writing using two-photon polymerization (2PP-DLW). First a dye doped photoresist is used for UV-lithography. Adding an undoped photoresist on top of the developed structures enables three-dimensional alignment of the 2PP-DLW structures by detecting the spatially varying fluorescence of the two photoresists. Using this approach we show three dimensional alignment by adding 3D structures made by 2PP-DLW to a previously UV-exposed structure. Furthermore, a fluidic system with an integrated total internal reflection mirror to observe particles in a microfluidic channel is demonstrated.


Assuntos
Lentes , Técnicas Analíticas Microfluídicas/instrumentação , Impressão Molecular/métodos , Fotografação/métodos , Polímeros/química , Polímeros/efeitos da radiação , Desenho de Equipamento , Análise de Falha de Equipamento , Teste de Materiais , Fótons , Propriedades de Superfície/efeitos da radiação , Raios Ultravioleta
4.
Opt Express ; 20(27): 28855-61, 2012 Dec 17.
Artigo em Inglês | MEDLINE | ID: mdl-23263126

RESUMO

We demonstrate the fabrication of single mode optical waveguides by irradiating polydimethylsiloxane (PDMS) with a low cost Hg lamp through a conventional quartz mask. By increasing the refractive index of the irradiated areas, waveguiding is achieved with an attenuation of 0.47 dB/cm at a wavelength of 635 nm. The refractive index change is stable in ambient air and water for time periods of more than 3 months. The excitation of water-dispersed fluorescent nanoparticles in the evanescent field of the waveguide is demonstrated.


Assuntos
Dimetilpolisiloxanos/química , Dispositivos Ópticos , Refratometria/instrumentação , Ressonância de Plasmônio de Superfície/instrumentação , Transdutores , Desenho de Equipamento , Análise de Falha de Equipamento , Raios Ultravioleta
5.
Opt Express ; 20(6): 6357-64, 2012 Mar 12.
Artigo em Inglês | MEDLINE | ID: mdl-22418517

RESUMO

The fabrication and characterization of continuously tunable, solution-processed distributed feedback (DFB) lasers in the visible regime is reported. Continuous thin film thickness gradients were achieved by means of horizontal dipping of several conjugated polymer and blended small molecule solutions on cm-scale surface gratings of different periods. We report optically pumped continuously tunable laser emission of 13 nm in the blue, 16 nm in the green and 19 nm in the red spectral region on a single chip respectively. Tuning behavior can be described with the Bragg-equation and the measured thickness profile. The laser threshold is low enough that inexpensive laser diodes can be used as pump sources.


Assuntos
Lasers de Estado Sólido , Compostos Orgânicos/química , Desenho de Equipamento , Análise de Falha de Equipamento , Soluções
6.
Lab Chip ; 12(1): 197-203, 2012 Jan 07.
Artigo em Inglês | MEDLINE | ID: mdl-22086498

RESUMO

Detection of fluorescence particles is a key method of flow cytometry. We evaluate the performance of a design for a microfluidic fluorescence particle detection device. Due to the planar design with low layer thicknesses, we avoid optical components such as lenses or dichroic mirrors and substitute them with a shadow mask and colored film filters. A commercially available LED is used as the light source and a PIN-photodiode as detector. This design approach reduces component cost and power consumption and enables supplying the device with power from a standard USB port. From evaluation of this design, we obtain a maximum particle detection frequency of up to 600 particles per second at a sensitivity of better than 4.7 × 10(5) MESF (molecules of equivalent soluble fluorochrome) measured with particles for FITC sensitivity calibration. Lowering the flow rate increases the instrument sensitivity by an order of magnitude enabling the detection of particles with 4.5 × 10(4) MESF.


Assuntos
Citometria de Fluxo/instrumentação , Técnicas Analíticas Microfluídicas/instrumentação , Eletrônica , Desenho de Equipamento , Fluoresceína-5-Isotiocianato/química , Corantes Fluorescentes/química , Tamanho da Partícula , Sensibilidade e Especificidade , Espectrometria de Fluorescência
7.
J Am Chem Soc ; 133(49): 19602-5, 2011 Dec 14.
Artigo em Inglês | MEDLINE | ID: mdl-22085263

RESUMO

We show that polybis(thienyl)thienodia-thiazolethiophene (PDDTT), a high-performance semiconducting polymer for photodetectors and field-effect transistors, has strong performance dependence on annealing temperature. An unprecedented increase of 3 orders of magnitude is observed in both transistor and photoconductive properties. XRD and AFM evidence points to increased ordering in PDDTT films with annealing. This correlation highlights the importance that order has in determining performance in PDDTT and has possible implications in the design of polymers.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA