Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
JACC Cardiovasc Imaging ; 3(4): 343-8, 2010 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-20394894

RESUMO

OBJECTIVES: The purpose of this study was to understand the reason for variation in the sensitivity of different methods of detecting right-to-left shunts (RLS). BACKGROUND: Patent foramen ovale (PFO) is implicated in the pathogenesis of cryptogenic stroke, decompression illness, and migraine headaches. Intravenous agitated saline injections with tomographic imaging (transthoracic, transesophageal, and intracardiac echocardiography) has been used for detecting intracardiac shunts. Some patients with a high clinical suspicion of PFO have inconclusive echocardiographic study results. Transcranial Doppler (TCD) is an alternative method for detecting RLS that is not dependent on tomographic imaging. METHODS: Thirty-eight consecutive patients who were undergoing PFO closure had simultaneous transcranial Doppler and intracardiac echocardiography performed. Agitated saline injections were performed at rest, with Valsalva maneuver, and with forced expiration into a manometer to 40 mm Hg before and after closure, as well as 3 or more months after closure. Right atrial pressures were measured in the periprocedural period, and RLS were graded according to standard methods during these maneuvers. RESULTS: Right atrial pressures were significantly higher with Valsalva maneuver compared with rest (before closure 21.6 +/- 11.9 mm Hg vs. 6.6 +/- 2.6 mm Hg, p < 0.001; after closure 28.4 +/- 13.9 mm Hg vs. 6.8 +/- 2.6 mm Hg, p < 0.001) and with manometer compared with Valsalva maneuver (before closure 38.7 +/- 6.6 mm Hg vs. 21.6 +/- 11.9 mm Hg, p < 0.001; after closure 44.0 +/- 9.5 mm Hg vs. 28.4 +/- 13.9 mm Hg, p < 0.001). Intracardiac echocardiography underestimated shunting in 34% of patients with Valsalva maneuver or manometer after closure compared with TCD. CONCLUSIONS: Transcranial Doppler with immediate feedback provided by forced expiration against a manometer to 40 mm Hg is more sensitive than echocardiographic imaging for the detection of RLS. These observations have significant implications for determining the incidence of RLS in patients with stroke or migraine.


Assuntos
Circulação Cerebrovascular , Circulação Coronária , Ecocardiografia Transesofagiana , Forame Oval Patente/diagnóstico por imagem , Ultrassonografia Doppler Transcraniana , Adulto , Idoso , Função do Átrio Direito , Cateterismo Cardíaco/instrumentação , Feminino , Forame Oval Patente/complicações , Forame Oval Patente/fisiopatologia , Forame Oval Patente/terapia , Humanos , Ataque Isquêmico Transitório/diagnóstico por imagem , Ataque Isquêmico Transitório/etiologia , Ataque Isquêmico Transitório/fisiopatologia , Masculino , Manometria , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Pressão , Dispositivo para Oclusão Septal , Cloreto de Sódio , Acidente Vascular Cerebral/diagnóstico por imagem , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/fisiopatologia , Fatores de Tempo , Resultado do Tratamento , Manobra de Valsalva
2.
Catheter Cardiovasc Interv ; 75(5): 794-8, 2010 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-20146311

RESUMO

OBJECTIVES: To determine the safety and immediate efficacy after balloon aortic valvuloplasty (BAV) with a new, low-profile balloon. BACKGROUND: BAV has a continuing role in the management of high-risk patients with severe aortic stenosis (AS). BAV with traditional noncompliant balloons requires a large femoral arteriotomy and is associated with high rates of access site complications. METHODS: We retrospectively reviewed medical records of 20 consecutive patients undergoing BAV for severe AS. Retrograde transfemoral BAV was performed with a low-profile, compliant valvuloplasty balloon. Before and after BAV, transaortic gradients were measured invasively and by echocardiography, and aortic valve area (AVA) calculated. Access site complications, functional class and survival were recorded. RESULTS: Patients were 79 +/- 12 years old and had an estimated mortality from open aortic valve replacement of (12.5 +/- 9.6)%. By catheterization, mean aortic gradient fell from 44 +/- 15 to 29 +/- 10 mm Hg (P < 0.001) and AVA increased from 0.63 +/- 0.22 to 0.89 +/- 0.33 cm(2) (P < 0.001). New York Heart Association functional class improved from 3.5 +/- 0.7 to 2.7 +/- 0.8. Procedural mortality was 0%. There were no vascular complications or significant worsening of aortic regurgitation. CONCLUSION: Transfemoral BAV using a low-profile compliant balloon is feasible with acceptable immediate results and safety.


Assuntos
Estenose da Valva Aórtica/terapia , Cateterismo/instrumentação , Implante de Prótese de Valva Cardíaca/instrumentação , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Cateterismo/efeitos adversos , Complacência (Medida de Distensibilidade) , Ecocardiografia Doppler em Cores , Desenho de Equipamento , Artéria Femoral , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos , Hemodinâmica , Humanos , Pessoa de Meia-Idade , Recuperação de Função Fisiológica , Estudos Retrospectivos , Medição de Risco , Índice de Gravidade de Doença , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA