Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Diabetes Res Clin Pract ; 205: 110974, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37884063

RESUMO

AIMS: In recent-onset type 1 diabetes, clamp-derived C-peptide predicts good response to anti-CD3. Elevated proinsulin and proinsulin/C-peptide ratio (PI/CP) suggest increased metabolic/inflammatory beta cell burden. We reanalyzed trial data to compare the ability of baseline acutely glucose-stimulated proinsulin, C-peptide and PI/CP to predict functional outcome. METHODS: Eighty recent-onset type 1 diabetes patients participated in the placebo-controlled otelixizumab (GSK; NCT00627146) trial. Hyperglycemic clamps were performed at baseline, 6, 12 and 18 months, involving 3 h of induced euglycemia, followed by acutely raising and maintaining glycemia to ≥ 10 mmol/l for 140 min. Plasma proinsulin, C-peptide and PI/CP were determined after acute (minute 0 at 10 mmol/l; PI0, CP0, PI/CP0) and sustained glucose stimulation (AUC between minutes 60-140). Outcome was assessed as change in AUC60-140 C-peptide from baseline. RESULTS: In multiple linear regression, higher baseline (≥median [P50]) PI0 independently predicted preservation of beta cell function in response to anti-CD3 and interacted significantly with IAA. During follow-up, anti-CD3 tempered a further increase in PI/CP0, but not in PI0. CP0 outperformed PI0 and PI/CP0 for post-treatment monitoring. CONCLUSIONS: In recent-onset type 1 diabetes, elevated acutely glucose-stimulated proinsulin may complement or replace acutely or sustainedly stimulated C-peptide release for identifying good responders to anti-CD3, but not as outcome measure.


Assuntos
Diabetes Mellitus Tipo 1 , Proinsulina , Humanos , Proinsulina/metabolismo , Proinsulina/uso terapêutico , Diabetes Mellitus Tipo 1/tratamento farmacológico , Insulina/uso terapêutico , Glucose/uso terapêutico , Peptídeo C , Glicemia/metabolismo
2.
Ann Lab Med ; 42(5): 566-574, 2022 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-35470274

RESUMO

Background: Chloride measurement is crucial for calculating the anion gap. Bicarbonate can interfere with chloride measurements; however, there is no information on the specific types of electrodes affected or the changes in bicarbonate non-selectivity over time. We evaluated the interference of bicarbonate on chloride measurements using different electrodes and the stability of this interference over time. Methods: The effect of bicarbonate on chloride measured with electrodes of various manufacturers was assessed. When non-selectivity toward bicarbonate was observed, the stability of this interference during the electrode's lifetime was explored. The impact of the bicarbonate concentration on the calibrator was also evaluated. Results: Non-selectivity was observed for electrodes using quaternary ammonium salts (Beckman Coulter, Siemens, and Roche), with overestimated or underestimated chloride values observed at high or low bicarbonate concentrations, respectively. The degree of selectivity varied among electrodes. With the Roche electrode, interference became more pronounced over time, whereas the Siemens electrode appeared to gain selectivity during its lifetime. For the Roche system, adjusting the calibrator's bicarbonate concentration from 30 mmol/L to 20-24 mmol/L reduced the number of samples with unacceptable bias (>3%) from 77.3% to 12.6%. Lot-to-lot variations in the calibrator bicarbonate concentration increased the uncertainty of chloride measurements. Conclusions: The extent of bicarbonate-induced error varied according to the type, manufacturer, and wear of the electrode; the bicarbonate concentration in the calibrators and the tested sample; and the chloride content. Laboratories should be aware of the impact of bicarbonate on routine chloride measurements to establish appropriate QC procedures.


Assuntos
Bicarbonatos , Cloretos , Humanos , Eletrodos Seletivos de Íons
4.
Int J Lab Hematol ; 41(4): 448-455, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-31305028

RESUMO

INTRODUCTION: The analytical and clinical performance as well as the workflow efficiency of the novel, prototype Alinity hq hematology analyzer was evaluated in the clinical laboratory of Universitair Ziekenhuis Brussel, Department of Hematology, Brussels, Belgium. METHODS: Within-run and within-laboratory imprecision, linearity, and carryover were assessed using clinical blood samples and commercial blood products. Four hundred and seventeen samples were selected for method comparison with Abbott CELL-DYN Sapphire, and for flagging performance analysis in comparison with smear review and manual microscopic white blood cell (WBC) differential. RESULTS: Within-run and within-laboratory imprecision verification demonstrated low %CV for complete blood count and WBC differential results within the normal ranges (0.1%-10.4%), except for basophil granulocytes. The linearity of the analytical measuring ranges was verified for WBCs, red blood cells, hemoglobin, and platelets. Alinity hq results showed strong agreement with those of CELL-DYN Sapphire. Good correlation was demonstrated with manual WBC differential results, with negative bias for neutrophil (NEU) granulocytes, and positive bias for lymphocytes and monocytes. Blasts were detected with 75% sensitivity and 96% specificity at 1% blast threshold, and 100% sensitivity at 5% blast threshold. Immature granulocyte detection was more sensitive (81% vs 76%, P = 0.086) and specific (88% vs 78%, P = 0.0002) than with CELL-DYN Sapphire. Nucleated red blood cell detection was more sensitive (89% vs 63%, P < 0.001) and just slightly less specific (96% vs 99%, P = 0.0067) than with CELL-DYN Sapphire. Re-run and reflex testing rates were lower with Alinity hq. CONCLUSION: The Alinity hq hematology analyzer is suitable for clinical use.


Assuntos
Laboratórios Hospitalares , Humanos , Contagem de Leucócitos/instrumentação , Contagem de Leucócitos/métodos
5.
Diabetes Care ; 40(8): 1065-1072, 2017 08.
Artigo em Inglês | MEDLINE | ID: mdl-28701370

RESUMO

OBJECTIVE: We investigated whether islet autoantibody profile, HLA-DQ genotype, and age influenced a 20-year progression to diabetes from first autoantibody positivity (autoAb+) in first-degree relatives of patients with type 1 diabetes. RESEARCH DESIGN AND METHODS: Persistently islet autoAb+ siblings and offspring (n = 462) under 40 years of age were followed by the Belgian Diabetes Registry. AutoAbs against insulin (IAA), GAD (GADA), IA-2 antigen (IA-2A), and zinc transporter 8 (ZnT8A) were determined by radiobinding assay. RESULTS: The 20-year progression rate of multiple-autoAb+ relatives (n = 194) was higher than that for single-autoAb+ participants (n = 268) (88% vs. 54%; P < 0.001). Relatives positive for IAA and GADA (n = 54) progressed more slowly than double-autoAb+ individuals carrying IA-2A and/or ZnT8A (n = 38; P = 0.001). In multiple-autoAb+ relatives, Cox regression analysis identified the presence of IA-2A or ZnT8A as the only independent predictors of more rapid progression to diabetes (P < 0.001); in single-autoAb+ relatives, it identified younger age (P < 0.001), HLA-DQ2/DQ8 genotype (P < 0.001), and IAA (P = 0.028) as independent predictors of seroconversion to multiple positivity for autoAbs. In time-dependent Cox regression, younger age (P = 0.042), HLA-DQ2/DQ8 genotype (P = 0.009), and the development of additional autoAbs (P = 0.012) were associated with more rapid progression to diabetes. CONCLUSIONS: In single-autoAb+ relatives, the time to multiple-autoAb positivity increases with age and the absence of IAA and HLA-DQ2/DQ8 genotype. The majority of multiple-autoAb+ individuals progress to diabetes within 20 years; this occurs more rapidly in the presence of IA-2A or ZnT8A, regardless of age, HLA-DQ genotype, and number of autoAbs. These data may help to refine the risk stratification of presymptomatic type 1 diabetes.


Assuntos
Autoanticorpos/sangue , Diabetes Mellitus Tipo 1/sangue , Progressão da Doença , Antígenos HLA-DQ/genética , Sistema de Registros , Adolescente , Adulto , Bélgica , Criança , Pré-Escolar , Diabetes Mellitus Tipo 1/genética , Feminino , Seguimentos , Humanos , Lactente , Insulina/sangue , Masculino , Modelos de Riscos Proporcionais , Fatores de Risco , Inquéritos e Questionários , Adulto Jovem , Transportador 8 de Zinco/sangue
7.
PLoS One ; 11(12): e0166702, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27907006

RESUMO

BACKGROUND: The hyperglycemic clamp test, the gold standard of beta cell function, predicts impending type 1 diabetes in islet autoantibody-positive individuals, but the latter may benefit from less invasive function tests such as the proinsulin:C-peptide ratio (PI:C). The present study aims to optimize precision of PI:C measurements by automating a dual-label trefoil-type time-resolved fluorescence immunoassay (TT-TRFIA), and to compare its diagnostic performance for predicting type 1 diabetes with that of clamp-derived C-peptide release. METHODS: Between-day imprecision (n = 20) and split-sample analysis (n = 95) were used to compare TT-TRFIA (AutoDelfia, Perkin-Elmer) with separate methods for proinsulin (in-house TRFIA) and C-peptide (Elecsys, Roche). High-risk multiple autoantibody-positive first-degree relatives (n = 49; age 5-39) were tested for fasting PI:C, HOMA2-IR and hyperglycemic clamp and followed for 20-57 months (interquartile range). RESULTS: TT-TRFIA values for proinsulin, C-peptide and PI:C correlated significantly (r2 = 0.96-0.99; P<0.001) with results obtained with separate methods. TT-TRFIA achieved better between-day %CV for PI:C at three different levels (4.5-7.1 vs 6.7-9.5 for separate methods). In high-risk relatives fasting PI:C was significantly and inversely correlated (rs = -0.596; P<0.001) with first-phase C-peptide release during clamp (also with second phase release, only available for age 12-39 years; n = 31), but only after normalization for HOMA2-IR. In ROC- and Cox regression analysis, HOMA2-IR-corrected PI:C predicted 2-year progression to diabetes equally well as clamp-derived C-peptide release. CONCLUSIONS: The reproducibility of PI:C benefits from the automated simultaneous determination of both hormones. HOMA2-IR-corrected PI:C may serve as a minimally invasive alternative to the more tedious hyperglycemic clamp test.


Assuntos
Peptídeo C/sangue , Diabetes Mellitus Tipo 1/sangue , Hiperglicemia/sangue , Proinsulina/sangue , Adolescente , Adulto , Autoanticorpos/sangue , Criança , Pré-Escolar , Diabetes Mellitus Tipo 1/patologia , Jejum , Feminino , Teste de Tolerância a Glucose , Hemoglobinas Glicadas/metabolismo , Humanos , Hiperglicemia/patologia , Insulina/sangue , Resistência à Insulina/genética , Células Secretoras de Insulina/metabolismo , Células Secretoras de Insulina/patologia , Masculino , Prognóstico , Análise de Regressão
8.
J Clin Endocrinol Metab ; 101(4): 1490-7, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26859105

RESUMO

Glucose entropy was inversely correlated with insulin resistance in a series of non-diabetic individuals with low glucose variability. In long-standing type 1 diabetes, the inverse correlation between glucose entropy and insulin resistance is preserved, as lower glucose entropy is associated with higher BMI.


Assuntos
Glicemia/metabolismo , Diabetes Mellitus Tipo 1/fisiopatologia , Resistência à Insulina , Adolescente , Adulto , Idoso , Estudos de Casos e Controles , Criança , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Valores de Referência , Adulto Jovem
9.
Diabetologia ; 58(12): 2753-64, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26409458

RESUMO

AIMS/HYPOTHESIS: We examined whether measures of glycaemic variability (GV), assessed by continuous glucose monitoring (CGM) and self-monitoring of blood glucose (SMBG), can complement or replace measures of beta cell function and insulin action in detecting the progression of preclinical disease to type 1 diabetes. METHODS: Twenty-two autoantibody-positive (autoAb(+)) first-degree relatives (FDRs) of patients with type 1 diabetes who were themselves at high 5-year risk (50%) for type 1 diabetes underwent CGM, a hyperglycaemic clamp test and OGTT, and were followed for up to 31 months. Clamp variables were used to estimate beta cell function (first-phase [AUC5-10 min] and second-phase [AUC120-150 min] C-peptide release) combined with insulin resistance (glucose disposal rate; M 120-150 min). Age-matched healthy volunteers (n = 20) and individuals with recent-onset type 1 diabetes (n = 9) served as control groups. RESULTS: In autoAb(+) FDRs, M 120-150 min below the 10th percentile (P10) of controls achieved 86% diagnostic efficiency in discriminating between normoglycaemic FDRs and individuals with (impending) dysglycaemia. M 120-150 min outperformed AUC5-10 min and AUC120-150 min C-peptide below P10 of controls, which were only 59-68% effective. Among GV variables, CGM above the reference range was better at detecting (impending) dysglycaemia than elevated SMBG (77-82% vs 73% efficiency). Combined CGM measures were equally efficient as M 120-150 min (86%). Daytime GV variables were inversely correlated with clamp variables, and more strongly with M 120-150 min than with AUC5-10 min or AUC120-150 min C-peptide. CONCLUSIONS/INTERPRETATION: CGM-derived GV and the glucose disposal rate, reflecting both insulin secretion and action, outperformed SMBG and first- or second-phase AUC C-peptide in identifying FDRs with (impending) dysglycaemia or diabetes. Our results indicate the feasibility of developing minimally invasive CGM-based criteria for close metabolic monitoring and as outcome measures in trials.


Assuntos
Glicemia/análise , Diabetes Mellitus Tipo 1/sangue , Técnica Clamp de Glucose , Hiperglicemia/sangue , Adolescente , Adulto , Área Sob a Curva , Automonitorização da Glicemia , Peptídeo C/sangue , Criança , Feminino , Teste de Tolerância a Glucose , Hemoglobinas Glicadas/análise , Voluntários Saudáveis , Humanos , Células Secretoras de Insulina/metabolismo , Masculino , Adulto Jovem
10.
Diabetes Care ; 38(4): 644-51, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25583753

RESUMO

OBJECTIVE: Immune intervention trials in recent-onset type 1 diabetes would benefit from biomarkers associated with good therapeutic response. In the previously reported randomized placebo-controlled anti-CD3 study (otelixizumab; GlaxoSmithKline), we tested the hypothesis that specific diabetes autoantibodies might serve this purpose. RESEARCH DESIGN AND METHODS: In the included patients (n = 40 otelixizumab, n = 40 placebo), ß-cell function was assessed as area under the curve (AUC) C-peptide release during a hyperglycemic glucose clamp at baseline (median duration of insulin treatment: 6 days) and every 6 months until 18 months after randomization. (Auto)antibodies against insulin (I[A]A), GAD (GADA), IA-2 (IA-2A), and ZnT8 (ZnT8A) were determined on stored sera by liquid-phase radiobinding assay. RESULTS: At baseline, only better preserved AUC C-peptide release and higher levels of IAA were associated with better preservation of ß-cell function and lower insulin needs under anti-CD3 treatment. In multivariate analysis, IAA (P = 0.022) or the interaction of IAA and C-peptide (P = 0.013) independently predicted outcome together with treatment. During follow-up, good responders to anti-CD3 treatment (i.e., IAA(+) participants with relatively preserved ß-cell function [≥ 25% of healthy control subjects]) experienced a less pronounced insulin-induced rise in I(A)A and lower insulin needs. GADA, IA-2A, and ZnT8A levels were not influenced by anti-CD3 treatment, and their changes showed no relation to functional outcome. CONCLUSIONS: There is important specificity of IAA among other diabetes autoantibodies to predict good therapeutic response of recent-onset type 1 diabetic patients to anti-CD3 treatment. If confirmed, future immune intervention trials in type 1 diabetes should consider both relatively preserved functional ß-cell mass and presence of IAA as inclusion criteria.


Assuntos
Anticorpos Monoclonais Humanizados/uso terapêutico , Diabetes Mellitus Tipo 1/sangue , Diabetes Mellitus Tipo 1/tratamento farmacológico , Anticorpos Anti-Insulina/sangue , Células Secretoras de Insulina/efeitos dos fármacos , Adolescente , Adulto , Biomarcadores/sangue , Criança , Diabetes Mellitus Tipo 1/diagnóstico , Diabetes Mellitus Tipo 1/fisiopatologia , Feminino , Humanos , Insulina/uso terapêutico , Células Secretoras de Insulina/fisiologia , Masculino , Prognóstico , Fatores de Tempo , Resultado do Tratamento , Adulto Jovem
11.
J Clin Endocrinol Metab ; 100(2): 551-60, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25405499

RESUMO

CONTEXT AND OBJECTIVE: In preparation of future prevention trials, we aimed to identify predictors of 3-year diabetes onset among oral glucose tolerance test (OGTT)- and hyperglycemic clamp-derived metabolic markers in persistently islet autoantibody positive (autoAb(+)) offspring and siblings of patients with type 1 diabetes (T1D). DESIGN: The design is a registry-based study. SETTING: Functional tests were performed in a hospital setting. PARTICIPANTS: Persistently autoAb(+) first-degree relatives of patients with T1D (n = 81; age 5-39 years). MAIN OUTCOME MEASURES: We assessed 3-year predictive ability of OGTT- and clamp-derived markers using receiver operating characteristics (ROC) and Cox regression analysis. Area under the curve of clamp-derived first-phase C-peptide release (AUC(5-10 min); min 5-10) was determined in all relatives and second-phase release (AUC(120-150 min); min 120-150) in those aged 12-39 years (n = 62). RESULTS: Overall, the predictive ability of AUC(5-10 min) was better than that of peak C-peptide, the best predictor among OGTT-derived parameters (ROC-AUC [95%CI]: 0.89 [0.80-0.98] vs 0.81 [0.70-0.93]). Fasting blood glucose (FBG) and AUC(5-10 min) provided the best combination of markers for prediction of diabetes within 3 years; (ROC-AUC [95%CI]: 0.92 [0.84-1.00]). In multivariate Cox regression analysis, AUC(5-10 min)) (P = .001) was the strongest independent predictor and interacted significantly with all tested OGTT-derived parameters. AUC(5-10 min) below percentile 10 of controls was associated with 50-70% progression to T1D regardless of age. Similar results were obtained for AUC(120-150 min). CONCLUSIONS: Clamp-derived first-phase C-peptide release can be used as an efficient and simple screening strategy in persistently autoAb(+) offspring and siblings of T1D patients to predict impending diabetes.


Assuntos
Autoanticorpos/sangue , Filho de Pais com Deficiência , Diabetes Mellitus Tipo 1/sangue , Irmãos , Adolescente , Adulto , Criança , Pré-Escolar , Diabetes Mellitus Tipo 1/imunologia , Feminino , Intolerância à Glucose , Teste de Tolerância a Glucose , Humanos , Insulina/sangue , Masculino , Valor Preditivo dos Testes , Curva ROC , Adulto Jovem
12.
Diabetes ; 62(4): 1345-50, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-23160529

RESUMO

We investigated whether HLA-A*24 typing complements screening for HLA-DQ and for antibodies (Abs) against insulin, GAD, IA-2 (IA-2A), and zinc transporter-8 (ZnT8A) for prediction of rapid progression to type 1 diabetes (T1D). Persistently Ab(+) siblings/offspring (n = 288; aged 0-39 years) of T1D patients were genotyped for HLA-DQA1-DQB1 and HLA-A*24 and monitored for development of diabetes within 5 years of first Ab(+). HLA-A*24 (P = 0.009), HLA-DQ2/DQ8 (P = 0.001), and positivity for IA-2A ± ZnT8A (P < 0.001) were associated with development of T1D in multivariate analysis. The 5-year risk increased with the number of the above three markers present (n = 0: 6%; n = 1: 18%; n = 2: 46%; n = 3: 100%). Positivity for one or more markers identified a subgroup of 171 (59%) containing 88% of rapid progressors. The combined presence of HLA-A*24 and IA-2A(+) ± ZnT8A(+) defined a subgroup of 18 (6%) with an 82% diabetes risk. Among IA-2A(+) ± ZnT8A(+) relatives, identification of HLA-A*24 carriers in addition to HLA-DQ2/DQ8 carriers increased screening sensitivity for relatives at high Ab- and HLA-inferred risk (64% progression; P = 0.002). In conclusion, HLA-A*24 independently predicts rapid progression to T1D in Ab(+) relatives and complements IA-2A, ZnT8A, and HLA-DQ2/DQ8 for identifying participants in immunointervention trials.


Assuntos
Autoanticorpos/sangue , Diabetes Mellitus Tipo 1/genética , Predisposição Genética para Doença , Antígeno HLA-A24/sangue , Adolescente , Criança , Diabetes Mellitus Tipo 1/imunologia , Feminino , Antígeno HLA-A24/genética , Antígeno HLA-A24/metabolismo , Humanos , Masculino , Fatores de Risco , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA