Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Appl Radiat Isot ; 68(4-5): 735-7, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-19939686

RESUMO

A gynaecological applicator consisting of a metallic intra-uterine tube with a plastic vaginal applicator and an HDR Ir-192 source have been simulated with MCNP5 (Monte Carlo code). A solid phantom has been designed to perform measurements around the applicator with radiochromic films. The isodose curves obtained are compared with curves calculated with the F4MESH tally of MCNP5 with a good agreement. A pinpoint ionization chamber has been used to evaluate dose at some reference points.


Assuntos
Braquiterapia/instrumentação , Modelos Biológicos , Radiometria/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Neoplasias Uterinas/fisiopatologia , Neoplasias Uterinas/radioterapia , Simulação por Computador , Desenho Assistido por Computador , Desenho de Equipamento , Análise de Falha de Equipamento , Feminino , Humanos , Método de Monte Carlo , Dosagem Radioterapêutica , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
2.
Radiother Oncol ; 51(3): 249-56, 1999 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-10435820

RESUMO

BACKGROUND AND PURPOSE: Several commercially available p-type diodes do not provide sufficient build-up for in-vivo dosimetry in 'higher' energy photon beams, and only limited information could be found in the literature describing the correction factor variation and/or the achievable accuracy for in-vivo dosimetry methods in this energy range. The first aim of this study is to assess and analyze the variation of diode correction factors for entrance dose measurements at higher photon energies. In a second step the total build up thickness of the diode has been modified in order to minimize the correction factor variation. MATERIALS AND METHODS: Diode correction factors accounting for non-reference conditions (field size, source surface distance, tray, wedge, and block) are determined in 18-25 MV photon beams provided by different treatment units for Scanditronix p-type diodes recommended for higher energy photon beams: old type and new type EDP-20, and EDP-30 diodes. Hemispherical build-up caps of different materials (copper, iron, lead) are used to increase the total build-up thickness. Perturbation effects with and without additional build-up caps are assessed for the three diode types. RESULTS: For unmodified diodes field size correction factors (C(FS)) vary between 1.7% and 6%, dependent on diode type and treatment unit. For example, for an old type EDP-20 the C(FS) variation at 18 MV is much higher on a GE linac (5%) as compared to the Philips machine (1.7%). Depending on diode type, this variation can be reduced to 1-2% when adding additional build-up. The variation of source to surface distance correction factors is almost independent of build-up thickness. By adding additional build-up the influence of trays and blocks can be almost eliminated. CONCLUSIONS: The correction factor variation of unmodified diodes reflects the variation of the electron contamination with treatment geometry. A total build-up thickness of 30 mm is found to be the 'best compromise' for the three types of diodes investigated when measuring entrance doses in the energy range between 18 and 25 MV.


Assuntos
Radioterapia de Alta Energia/instrumentação , Relação Dose-Resposta à Radiação , Humanos , Aceleradores de Partículas , Radiometria , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Alta Energia/métodos , Valores de Referência
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA