RESUMO
The aim of this study was to evaluate different techniques for diagnosing wound infection in wounds healing by second intention in horses and to assess the effect of a vortex and sonication protocol on quantitative bacteriology in specimens with a histologically confirmed biofilm. In 50 wounds healing by second intention, a clinical assessment, a quantitative swab, a semi-quantitative swab, and a swab for cytology were compared to a quantitative tissue biopsy (reference standard). Part of the biopsy specimen was examined histologically for evidence of a biofilm. There was a significant, high correlation (P<0.001; r=0.747) between the outcome of the quantitative swabs and the quantitative biopsies. The semi-quantitative swabs showed a significant, moderate correlation with the quantitative biopsies (P<0.001; ρ=0.524). Higher white blood cell counts for cytology were significantly associated with lower log10 colony-forming units (CFU) in the wounds (P=0.02). Wounds with black granulation tissue showed significantly higher log10 CFU (P=0.003). Specimens with biofilms did not yield higher bacteriological counts after a vortex and sonication protocol was performed to release bacteria from the biofilm. Based on these findings, a quantitative swab is an acceptable non-invasive alternative to a quantitative biopsy for quantifying bacterial load in equine wounds healing by second intention.
Assuntos
Carga Bacteriana/veterinária , Biópsia/veterinária , Doenças dos Cavalos/microbiologia , Manejo de Espécimes/veterinária , Cicatrização , Infecção dos Ferimentos/veterinária , Animais , Biofilmes , Doenças dos Cavalos/terapia , Cavalos , Manejo de Espécimes/métodos , Infecção dos Ferimentos/microbiologia , Infecção dos Ferimentos/terapiaRESUMO
The aim of this study was to compare the accuracy, precision, inter- and intra-operator reliability of a new laser beam (LB) wound camera and a digital photoplanimetry-based (DPB) method for measuring the dimensions of equine wounds. Forty-one wounds were created on equine cadavers. The area, circumference, maximum depth and volume of each wound were measured four times with both techniques by two operators. A silicone cast was made of each wound and served as the reference standard to measure the wound dimensions. The DPB method had a higher accuracy and precision in determining the wound volume compared with the LB camera, which had a higher accuracy in determining the wound area and maximum depth and better precision in determining the area and circumference. The LB camera also had a significantly higher overall inter-operator reliability for measuring the wound area, circumference and volume. In contrast, the DPB method had poor intra-operator reliability for the wound circumference. The LB camera was more user-friendly than the DPB method. The LB wound camera is recommended as the better objective method to assess the dimensions of wounds in horses, despite its poorer performance for the measurement of wound volume. However, if the wound measurements are performed by one operator on cadavers or animals under general anaesthesia, the DPB method is a less expensive and valid alternative.