1.
Med Phys ; 28(12): 2518-21, 2001 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-11797955

RESUMO

One of our linear accelerators is equipped with a free-movable treatment couch. An additional projects was to develop a system that first protects the free-movable couch against collisions, secondly build a remote control for moving the couch from outside the treatment room and finally implement this remote control/limitation system in an automatic position algorithm using an electronic portal image. The latter has been the subject of an on-going departmental investigation on intra-fractional correction of set-up errors. A few years ago, we developed a limitation system to protect both the table and the accelerator against collisions. In this paper we describe the second part of this project, the remote control system.


Assuntos
Desenho de Equipamento , Aceleradores de Partículas/instrumentação , Radioterapia/instrumentação , Algoritmos , Fenômenos Biofísicos , Biofísica
2.
Med Phys ; 27(2): 354-8, 2000 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-10718139

RESUMO

A computerized remote control for a Siemens ZXT treatment couch was implemented and its characteristics were investigated to establish its feasibility for on-line setup corrections, using portal imaging. Communication with the table was obtained by connecting it via a serial line to a work station. The treatment couch enables "goto" commands in the three main directions and around the isocenter. The accuracy of the movements after giving such a command was checked and the time for each movement was recorded. First, the movements into a single direction were studied (range of -4 to +4 cm and -4 degrees to +4 degrees). Each command was repeated four times. Second, the table was moved into the three main directions simultaneously. For this experiment a clinically relevant three-dimensional (3-D) normal distribution of shifts was used [N = 200, standard deviation (SD) 5 mm in the three main directions]. This latter experiment was done twice: without and with rotations (a distribution with SD 1 degrees). During the first experiment, with shifts into one direction, no systematic deviations were found. The overall accuracy of the shifts was 0.6 mm (1 SD) in each direction and 0.04 degrees (1 SD) for the rotations. The time required for a translation ranged between 4 and 13 s and for the rotation between 8 and 20 s. The second experiment with the 3-D distribution of setup errors yielded an error in the 3-D vector length equal to 0.96 mm (1 SD), independent of rotations. Shifts were performed in less than 11 s for 95% of the cases without rotations. When rotations were also performed, 95% of the movements finished in less than 16 s. In conclusion, the table movements are accurate and enable on-line setup corrections in daily clinical practice.


Assuntos
Radioterapia Assistida por Computador , Radioterapia Conformacional/métodos , Estudos de Viabilidade , Humanos , Sistemas On-Line , Postura , Radioterapia Assistida por Computador/instrumentação , Radioterapia Assistida por Computador/métodos , Radioterapia Conformacional/instrumentação , Software , Interface Usuário-Computador
3.
Med Phys ; 25(6): 897-9, 1998 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-9650179

RESUMO

Because of the capability of free movement in the treatment room, we recently introduced a Hercules treatment couch on one of our linear accelerators. One of the advantages of this couch is that it allows for a more flexible way of patient setup and that it can be moved entirely out of the way to enable treatment with a hospital bed. A disadvantage, however, is that the couch can hit a wall or a cover of the accelerator accidentally. A limitation system has been developed to protect both the table and the accelerator against such collisions.


Assuntos
Aceleradores de Partículas/instrumentação , Aceleradores de Partículas/estatística & dados numéricos , Algoritmos , Leitos , Fenômenos Biofísicos , Biofísica , Humanos , Microcomputadores , Movimento (Física) , Neoplasias/radioterapia