Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Pediatr Crit Care Med ; 24(8): 652-661, 2023 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-37092829

RESUMO

OBJECTIVES: Diaphragm ultrasound is a novel alternative to esophageal pressure measurements in the evaluation of diaphragm function and activity, but data about its reliability in a pediatric setting are lacking. We aimed to compare the esophageal pressure swing (∆P es , gold standard) with the diaphragmatic thickening fraction (DTF) as a measure of inspiratory effort in sedated children. Additionally, we studied the effect of positive end-expiratory pressure (PEEP) on the end-expiratory thickness of the diaphragm (DT ee ). DESIGN: Prospective open-label non-randomized interventional physiological cohort study. SETTING: Operating room in tertiary academic hospital. PATIENTS: Children 28 days to 13 years old scheduled for elective surgery with general anesthesia, spontaneously breathing through a laryngeal mask airway, were eligible for inclusion. Exclusion criteria were disorders or previous surgery of the diaphragm, anticipated difficult airway or acute cardiopulmonary disease. All measurements were performed prior to surgery. INTERVENTIONS: Patients were subjected to different levels of respiratory load, PEEP and anesthetic depth in a total of seven respiratory conditions. MEASUREMENTS AND MAIN RESULTS: The esophageal pressure and diaphragm thickening fraction were simultaneously recorded for five breaths at each respiratory condition. The relation between ∆P es and DTF was studied in a mixed model. We analyzed 407 breaths in 13 patients. Both DTF ( p = 0.03) and ∆Pes ( p = 0.002) could detect respiratory activity, and ∆P es and DTF were associated across respiratory conditions ( p < 0.001; R2 = 31%). With increasing inspiratory load, ∆P es increased significantly, while DTF did not ( p = 0.08). Additionally, DT ee did not differ significantly between 10, 5, and 0 cm H 2 O PEEP ( p = 0.08). CONCLUSIONS: In spontaneously breathing sedated children and across different respiratory conditions, DTF could differentiate minimal or no inspiratory effort from substantial inspiratory effort and was associated with ∆P es . Increased efforts resulted in higher ∆P es but not larger DTF.


Assuntos
Diafragma , Respiração Artificial , Humanos , Criança , Diafragma/diagnóstico por imagem , Estudos Prospectivos , Estudos de Viabilidade , Reprodutibilidade dos Testes , Estudos de Coortes , Respiração Artificial/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA