Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 33
Filtrar
1.
Head Face Med ; 20(1): 24, 2024 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-38627712

RESUMO

OBJECTIVES: A randomized controlled clinical trial of dental implants was conducted to compare the clinical properties of a novel electrochemically deposited calcium phosphate coating to those of a common marketed surface treatment. MATERIAL AND METHODS: Forty implants of the same brand and type were placed in 20 fully edentulous participants requiring mandibular implantation. The two study groups were defined by the surface treatment of the implants. 20 implants in the control group were coated via a commercial electrochemical surface treatment that forms a mixture of brushite and hydroxyapatite, while the remaining 20 in the test group were coated with a novel electrochemical Smart Bioactive Trabecular Coating (SBTC®). A split-mouth design was employed, with each participants receiving one control implant in one mandibular side and a test implant in the other. To mitigate potential operator-handedness bias, control and test implants were randomly assigned to mandibular sides. All cases underwent digital planning, implant placement with a static surgical guide, and participants received locator-anchored full-arch dentures. The primary outcome was implant stability (measured using Osstell ISQ) assessed at insertion, loading, and then 3 months, 9 months, and 2 years post-insertion. The secondary outcome was bone level change (in millimeters) over the 2-year observation period. Oral health-related quality of life (OHRQL) was monitored using the OHIP-14 questionnaire. Complications and adverse events were recorded. RESULTS: Successful osseointegration and implant stability were achieved in all cases, allowing loading. ISQ values steadily increased throughout the observation period. While no significant differences were observed between the SBTC® and control coatings, the test group exhibited a higher ISQ gain. Bone resorption was somewhat lower in the SBTC® but not significantly so. Patients' OHRQL significantly improved after denture delivery and remained stable throughout the follow-up. No complications or adverse events were observed. CONCLUSIONS: Based on the study results, we conclude that the new surface treatment is a safe alternative to the widely used control surface, demonstrating similar osseointegrative properties and time-dependent bone level changes. Further research may explore the broader implications of these findings. TRIAL REGISTRATION: The study is registered on clinicaltrials.gov under the identifier ID: NCT06034171.


Assuntos
Implantes Dentários , Boca Edêntula , Humanos , Implantação Dentária Endóssea/métodos , Qualidade de Vida , Osseointegração , Resultado do Tratamento , Prótese Dentária Fixada por Implante/métodos , Planejamento de Prótese Dentária
2.
Orv Hetil ; 163(52): 2062-2066, 2022 Dec 25.
Artigo em Húngaro | MEDLINE | ID: mdl-36566438

RESUMO

INTRODUCTION: In our study, we aimed to investigate whether the COVID-19 infection itself or the vaccination against it affect the differentiation of T cells in the thymus, and whether the reduction in T cell counts observed in the blood of COVID-19-infected individuals is also observed at the tissue level in the thymus. METHOD: Data from a total of 55 thymectomy patients were processed to create three groups: 1) the pre-COVID-19 (PC) group included 22 patients, 12 women and 10 men, who underwent thymectomy between 2008 and 2013; 2) in the no-COVID-19 (NC) group (patients without verified infection or vaccination), 20 patients, 11 women and 9 men, underwent thymectomy in 2020-2021; 3) the vaccinated or infected COVID-19 (VIC) group included 13 patients, 4 women and 9 men, who underwent thymectomy also in 2020-2021. The pathological samples were immunohistochemically tested for CD4, CD8, CD25 and FOXP3 to verify the helper, cytotoxic and regulatory T cells. RESULTS: The VIC group had significantly lower values for CD4, compared to the PC and NC groups. The FOXP3 value was significantly lower in the VIC and NC groups compared to the PC group. No significant differences were found for CD8 and CD25 between the groups studied. DISCUSSION: The COVID-19 infection or vaccination affects the T cell composition of the thymus. Decreased expression of CD4 has been demonstrated in the VIC group, which confirms a decrease in the T cell counts that also occurs in the thymus. The low FOXP3 levels observed in the NC group during the COVID-19 era, compared to the PC group, may be indicative of a high rate of asymptomatic coronavirus infections and a worsening of immunetolerance. CONCLUSION: First in the world, we have verified that the helper T cell composition of the thymus in COVID-19 infection era is reduced, and in the asymptomatic patients the immune function is decreased as well. Orv Hetil. 2022; 163(52): 2062-2066.


Assuntos
COVID-19 , Pandemias , Linfócitos T , Timo , Feminino , Humanos , Masculino , COVID-19/imunologia , COVID-19/prevenção & controle , Fatores de Transcrição Forkhead/metabolismo , Timo/imunologia , Contagem de Linfócitos , Linfócitos T/imunologia , Vacinação
3.
BMJ Open ; 12(7): e057872, 2022 07 06.
Artigo em Inglês | MEDLINE | ID: mdl-35793921

RESUMO

INTRODUCTION: Early recognition and effective treatment of internal bleeding impose a cardinal challenge for trauma teams. The reduction of the superior mesenteric artery (SMA) blood flow is among the first compensatory responses to blood loss, thus being a promising candidate as a diagnostic tool for occult haemorrhage. Unfortunately, methods for monitoring the SMA flow have not been elaborated to date. Nevertheless, animal experiments suggest that exhaled methane (CH4) levels correspond to the SMA perfusion. We hypothesise that real-time detection of CH4 concentrations in the exhaled air is an applicable technique for the early recognition of haemorrhage in severely injured patients. We also hypothesise that exhaled CH4 levels reflect the volume of blood loss more accurately than conventional markers of blood loss and shock such as shock index, haemoglobin, base deficit, lactate, end-tidal carbon dioxide and sublingual microcirculatory indices. METHODS AND ANALYSIS: One hundred and eleven severely injured (Injury Severity Score ≥16), intubated, bleeding patients sustaining blunt trauma will be included in this prospective observational study. Blood loss will be detected with CT and estimated with CT-linked radiologic software. Exhaled CH4 concentrations will be monitored by attaching a near-infrared laser technique-based photoacoustic spectroscopy apparatus to the exhalation outlet of the ventilator on patient arrival. The primary outcome is the volume of blood loss. Need for massive transfusion and 24-hour mortality will constitute secondary outcomes. The relation of exhaled CH4 to study outcomes and its performance in predicting blood loss in comparison with conventional shock markers and microcirculatory indices will be tested. ETHICS AND DISSEMINATION: Our protocol (ID: 5400/2021-SZTE) has been registered on ClinicalTrials.gov (NCT04987411) and complies with the Declaration of Helsinki and has been approved by the medical ethics committee at the University of Szeged (Ref.nr.:121/2021-SZTE RKEB). It is in data collection phase, theresults will be shared with the scientific community through publication in a peer-reviewed journal. TRIAL REGISTRATION NUMBER: NCT04987411; ClinicalTrials.gov, registered on 27 July 2021.


Assuntos
Expiração , Ferimentos não Penetrantes , Animais , Hemorragia/complicações , Hemorragia/etiologia , Metano , Microcirculação , Estudos Observacionais como Assunto , Ferimentos não Penetrantes/complicações
4.
Int J Mol Sci ; 23(14)2022 Jul 07.
Artigo em Inglês | MEDLINE | ID: mdl-35886901

RESUMO

There is growing evidence regarding the role of mitochondrial dysfunction in osteoarthritis (OA) and rheumatoid arthritis (RA). However, quantitative comparison of synovial mitochondrial derangements in these main arthritis forms is missing. A prospective clinical study was conducted on adult patients undergoing knee surgery. Patients were allocated into RA and OA groups based on disease-specific clinical scores, while patients without arthritis served as controls. Synovial samples were subjected to high-resolution respirometry to analyze mitochondrial functions. From the total of 814 patients, 109 cases were enrolled into the study (24 RA, 47 OA, and 38 control patients) between 1 September 2019 and 31 December 2021. The decrease in complex I-linked respiration and dyscoupling of mitochondria were characteristics of RA patients, while both arthritis groups displayed reduced OxPhos activity compared to the control group. However, no significant difference was found in complex II-related activity between the OA and RA groups. The cytochrome C release and H2O2 formation were increased in both arthritis groups. Mitochondrial dysfunction was present in both arthritis groups; however, to a different extent. Consequently, mitochondrial protective agents may have major benefits for arthritis patients. Based on our current study, we recommend focusing on respiratory complex I in rheumatoid arthritis research.


Assuntos
Artrite Reumatoide , Osteoartrite , Adulto , Artrite Reumatoide/metabolismo , Humanos , Peróxido de Hidrogênio/metabolismo , Mitocôndrias , Osteoartrite/metabolismo , Estudos Prospectivos , Líquido Sinovial/metabolismo , Membrana Sinovial/metabolismo
5.
Front Surg ; 9: 822560, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35360436

RESUMO

Surgical procedures cause stress, which can induce an inflammatory response and reduce immune function. Following video-assisted thoracoscopic surgery (VATS), non-intubated thoracic surgery (NITS) was developed to further reduce surgical stress in thoracic surgical procedures. This article reviews the pathophysiology of the NITS procedure and its potential for reducing the negative effects of mechanical one-lung ventilation (mOLV). In NITS with spontaneous ventilation, the negative side effects of mOLV are prevented or reduced, including volutrauma, biotrauma, systemic inflammatory immune responses, and compensatory anti-inflammatory immune responses. The pro-inflammatory and anti-inflammatory cytokines released from accumulated macrophages and neutrophils result in injury to the alveoli during mOLV. The inflammatory response is lower in NITS than in relaxed-surgery cases, causing a less-negative effect on immune function. The increase in leukocyte number and decrease in lymphocyte number are more moderate in NITS than in relaxed-surgery cases. The ventilation/perfusion match is better in spontaneous one-lung ventilation than in mOLV, resulting in better oxygenation and cardiac output. The direct effect of relaxant drugs on the acetylcholine receptors of macrophages can cause cytokine release, which is lower in NITS. The locoregional anesthesia in NITS is associated with a reduced cytokine release, contributing to a more physiological postoperative immune function.

6.
Clin Oral Investig ; 26(1): 1035-1043, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34401946

RESUMO

OBJECTIVES: To compare the accuracy of implant placement performed with either a surgical motor or a torque wrench as part of a half-guided surgical protocol. MATERIALS AND METHODS: Implant insertion with half-guided surgical protocol was utilized by surgical motor (machine-driven group) or torque wrench (manual group) in the posterior maxilla. After the healing period, accuracy comparison between planned and actual implant positions was performed based on preoperative cone beam computed tomography and postoperative digital intraoral scans. Coronal, apical, and angular deviations, insertion time, and insertion torque were evaluated. RESULTS: Forty patients were treated with 1 implant each; 20 implants were inserted with a surgical motor and 20 implants with a torque wrench. Global coronal and apical deviations were 1.20 ± 0.46 mm and 1.45 ± 0.79 mm in the machine-driven group, and 1.13 ± 0.38 mm and 1.18 ± 0.28 mm in the manual group (respectively). The mean angular deviation was 4.82 ± 2.07° in the machine-driven group and 4.11 ± 1.63° in the manual group. Mean insertion torque was 21.75 ± 9.75 Ncm in the machine-driven group, compared to 18.75 ± 7.05 Ncm in the manual group. Implant placement duration was 9.25 ± 1.86 s in the machine-driven group at a speed of 50 rpm, and 36.40 ± 8.15 s in the manual group. CONCLUSION: No significant difference was found between the two groups in terms of accuracy and mean insertion torque, while machine-driven implant placement was significantly less time-consuming. CLINICAL RELEVANCE: Optimal implant placement accuracy utilized by half-guided surgical protocol can be achieved with both machine-driven and torque wrench insertion. TRIAL REGISTRATION: ID: NCT04854239.


Assuntos
Implantes Dentários , Cirurgia Assistida por Computador , Tomografia Computadorizada de Feixe Cônico , Implantação Dentária Endóssea , Humanos , Maxila/diagnóstico por imagem , Maxila/cirurgia , Estudos Prospectivos
7.
BMC Sports Sci Med Rehabil ; 13(1): 149, 2021 Nov 25.
Artigo em Inglês | MEDLINE | ID: mdl-34823577

RESUMO

BACKGROUND: Anterior cruciate ligament injury arises when the knee anterior ligament fibers are stretched, partially torn, or completely torn. Operated patients either end up re-injuring their reconstructed anterior cruciate ligament or majority develop early osteoarthritis regardless of the remarkable improvements of surgical techniques and the widely available rehabilitation best practices. New mechanism theories of non-contact anterior cruciate ligament injury and delayed onset muscle soreness could provide a novel perspective how to respond to this clinical challenge. MAIN BODY: A tri-phasic injury model is proposed for these non-contact injuries. Mechano-energetic microdamage of the proprioceptive sensory nerve terminals is suggested to be the first-phase injury that is followed by a harsher tissue damage in the second phase. The longitudinal dimension is the third phase and that is the equivalent of the repeated bout effect of delayed onset muscle soreness. Current paper puts this longitudinal injury phase into perspective as the phase when the long-term memory consolidation and reconsolidation of this learning related neuronal injury evolves and the phase when the extent of the neuronal regeneration is determined. Reinstating the mitochondrial energy supply and 'breathing capacity' of the injured proprioceptive sensory neurons during this period is emphasized, as avoiding fatigue, overuse, overload and re-injury. CONCLUSIONS: Extended use, minimum up to a year or even longer, of a current rehabilitation technique, namely moderate intensity low resistance stationary cycling, is recommended preferably at the end of the day. This exercise therapeutic strategy should be a supplementation to the currently used rehabilitation best practices as a knee anti-aging maintenance effort.

8.
Eur Surg Res ; 62(4): 229-237, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34482309

RESUMO

PURPOSE: The aim was to examine the predictive value of the hypovolemic shock classification currently accepted by the Advanced Trauma Life Support (ATLS) program over the previous one, which used only vital signs (VS) for patient allocation. The primary outcome was 30-day mortality; as secondary outcome, heart rate (HR), systolic blood pressure (SBP), Glasgow Coma Scale (GCS) and base deficit (BD) data were compared and investigated in terms of mortality prediction. METHODS: Retrospective analysis at a level I trauma center between 2014 and 2019. Adult patients treated by trauma teams were allocated into severity classes (I-IV) based on the criteria of the current and previous ATLS classifications, respectively. The prognostic values for the classifications were determined with Fisher's exact test and χ2 test for independence, and compared with the 2-proportion Z test. The individual variables were analyzed with receiver-operating characteristic (ROC) analyses. RESULTS: A total of 156 patients met the inclusion criteria. Mortality was effectively predicted by both classifications, and there was no statistically significant difference between the predictive performances. According to ROC analyses, GCS, BD and SBP had significant prognostic values while HR change was ineffective in this regard. CONCLUSIONS: The currently used ATLS shock classification does not appear to be superior to the VS-based previous classification. GCS, BD and SBP are useful parameters to predict the prognosis. Changes in HR do not reflect the clinical course accurately; thus, further studies will be needed to determine the value of this parameter in trauma-associated hypovolemic-hemorrhagic shock conditions.


Assuntos
Choque , Ferimentos e Lesões , Adulto , Escala de Coma de Glasgow , Humanos , Curva ROC , Estudos Retrospectivos , Choque/classificação , Centros de Traumatologia , Ferimentos e Lesões/classificação
9.
BMC Musculoskelet Disord ; 22(1): 730, 2021 Aug 24.
Artigo em Inglês | MEDLINE | ID: mdl-34429099

RESUMO

Patient-specific Instrumentation (PSI) is an innovative technique aiding the precise implementation of the preoperative plan during total knee arthroplasty (TKA) by using patient-specific guides and cutting blocks. Despite of the theoretical advantages, studies have reported contradictory results, thus there is no consensus regarding the overall effectiveness of PSI. Through the critical assessment of a meta-analysis published lately, this correspondence aims to highlight the complexity of comparing the efficacy of PSI to standard instrumentation (SI). The accuracy of component alignment, patient-reported outcome measures (PROMs), surgery time, blood loss, transfusion rate, and postoperative complications are commonly used outcomes for investigating the efficacy of PSI-aided TKA. By assessing component alignment, the expertise of the surgeon(s) should be taken into consideration, since PSI may not provide benefits for expert surgeons but might improve accuracy and patient safety during the learning curve of novice surgeons. With respect to PROMs and postoperative complications, PSI may not improve short-term results; however, long-term follow up data is missing. Regarding transfusion rates, favorable trends can be observed, but further studies utilizing recent data are needed for a clear conclusion. When assessing surgery time, we suggest focusing on operating room turnover instead of procedure time.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Artroplastia do Joelho/efeitos adversos , Humanos , Duração da Cirurgia , Medidas de Resultados Relatados pelo Paciente , Navios
10.
Injury ; 52 Suppl 1: S74-S77, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-32067776

RESUMO

Diabetes is a common disease that potentially interferes with healing processes after lower limb trauma. In our presented case a trimalleolar ankle fracture with undiscovered serious soft-tissue injuries resulted in chronic soft-tissue complications in a diabetic patient, requiring three and a half months of hospitalization in a higher level center and the application of state-of-the-art wound treatment, including vacuum-assisted closure therapy, Integra bioengineered skin substitute, split-thickness skin-grafting, and methods enhancing wound healing, such as polarized light therapy and transdermal CO2 delivery. The presented case emphasizes the importance of soft-tissue care and multidisciplinary approach in diabetic trauma patients with poor compliance.


Assuntos
Avulsões Cutâneas , Diabetes Mellitus , Traumatismos da Perna , Lesões dos Tecidos Moles , Avulsões Cutâneas/diagnóstico por imagem , Avulsões Cutâneas/cirurgia , Humanos , Traumatismos da Perna/cirurgia , Transplante de Pele , Lesões dos Tecidos Moles/cirurgia , Resultado do Tratamento
11.
Injury ; 52 Suppl 1: S7-S14, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-32674886

RESUMO

BACKGROUND: Tracheobronchial injuries are rare but feasibly life-threatening conditions. A prompt diagnosis and early management can be lifesaving. Due to the unspecific symptoms and indirect radiological signs the diagnosis often delays. OBJECTIVES: We present a short series of patients suffering from tracheobronchial airway laceration. All the three patients had blunt thoracic or neck trauma and showed early signs of tracheobronchial injury. In the first case a 44-year-old woman was crushed by a bus. Subcutaneous emphysema, pneumothorax on chest computed tomography and hypoxaemia despite of chest tube suggested the presence of an airway injury. During operation a 4-cm-long tear of the trachea and a complete transection of the right main bronchus were found. In the second case a 12-year-old girl was crossed by a truck trailer. Early signs were respiratory failure, extended subcutaneous emphysema, blood clot in the larynx, pneumothorax on both sides. Chest CT showed pneumomediastinum. During the operation a longitudinal laceration was found separating the two main bronchi at the bifurcation. In the third case a 9-year-old boy was injured in a car accident, when the seat-belt crossed his neck. Spreading subcutaneous emphysema, pneumomediastinum and an overinflated endotracheal tube's cuff were found on CT. A completely transected trachea between the first and second tracheal rings was found. All three patients required fast intubation and bronchoscopic examination to confirm the diagnosis, and to identify the site of lacerations. All the patients underwent primary reconstruction and recovered successfully. CONCLUSIONS: In case of suspected tracheobronchial injury, a high index of suspicion is required for early diagnosis. Most commonly respiratory distress, subcutaneous emphysema and pneumothorax are found on physical examination. Prompt intubation below the site of the injury and early laryngo- or bronchoscopic examination have priority, as we did in our cases. A primary anastomosis is required with minimal resection during urgent operation. A better outcome is to be expected when extubation is done early after surgery. We offer ordinal steps that should be taken to lead to a prompt management and good long-term outcome based on the literature and our experiences.


Assuntos
Enfisema Mediastínico , Pneumotórax , Traumatismos Torácicos , Ferimentos não Penetrantes , Adulto , Brônquios/diagnóstico por imagem , Brônquios/lesões , Brônquios/cirurgia , Criança , Feminino , Humanos , Masculino , Traqueia/diagnóstico por imagem , Traqueia/lesões , Traqueia/cirurgia , Ferimentos não Penetrantes/diagnóstico por imagem , Ferimentos não Penetrantes/cirurgia
13.
Injury ; 52 Suppl 1: S3-S6, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33280891

RESUMO

INTRODUCTION: We examined the endosteal and periosteal circulations in a patient with fracture non-union who had undergone excessive osteosynthesis applications (two long plates had been placed medially and laterally on the left tibia extending from the proximal 2/7 to the distal 6/7 parts of the bone, while a tibial component of a total knee prosthesis with a long stem had been inserted at the same time). METHODS: Concomitant perfusion changes were determined in the anterolateral and anteromedial periosteal sheath of the non-united bone ends and intramedullary nearest the osteosynthesis materials during their surgical removal on re-operation. The blood flow in the periosteum and endosteum was recorded by a laser-Doppler flowmetric device using a novel approach. Control measurements were made at identical points of the right tibia. RESULTS: Considerably lower blood flow values were measured along the tibial periosteal region of the re-operated limb than on the contralateral side (the average perfusion unit (PU) was 76 vs. 106 PU, respectively). Perfusion values were markedly lower in the endosteal region (average values of approx. 30 PU) in the control tibia and were even more diminished in the re-operated tibial endosteum (average 9 PU). CONCLUSIONS: Our study was conducted to characterize the microcirculatory changes of a long bone in response to intramedullary implantation and to provide quantitative data on the insufficiency of local perfusion in a patient with fracture non-union. Our results highlight the association between local perfusion failure and the unfavorable outcome (i.e. fracture non-union), confirming that the vital aspects of the microcirculation should not be disregarded when aiming for mechanical stability. Microcirculatory measurements constitute a new area of improvement in planning the adequate treatment for fracture non-unions with an unclear aetiology. Further refinement of the laser-Doppler technique could have potential benefits for bone surgery and postoperative trauma care in the future.


Assuntos
Artroplastia do Joelho , Fraturas da Tíbia , Placas Ósseas , Fixação Interna de Fraturas , Humanos , Microcirculação , Periósteo , Tíbia/cirurgia , Fraturas da Tíbia/diagnóstico por imagem , Fraturas da Tíbia/cirurgia
14.
Eur J Trauma Emerg Surg ; 46(4): 737-741, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32712775

RESUMO

PURPOSE: In the absence of effective treatment options, the recent SARS-CoV2 pandemic poses a great challenge to the health and social sectors worldwide. Hereby, we would like to share our proposals in the hope that it will prove helpful for our colleagues in this difficult time. METHODS: The present recommendations are based on the opinion of experts as well as the experience of a group of traumatologists directly involved in the organization of traumatology wards. The reassignment of the healthcare personnel, the separation of the potentially infected patients and the different levels of restriction on the trauma care are all key elements of our protocol. RESULTS: Since the first SARS-CoV2-positive case was confirmed in Hungary, our trauma surgeons were able to avoid contamination with the help of the new guidelines, without reducing the quality of trauma care. CONCLUSION: Reasonably adjusted patient care protocols in every medical field are key to contain the spread of infection and to avoid public health crisis. Sharing experience can be an important element of a successful fight against the recent pandemic.


Assuntos
Protocolos Clínicos , Infecções por Coronavirus , Controle de Infecções , Pandemias , Pneumonia Viral , Centros de Traumatologia/organização & administração , Ferimentos e Lesões , Betacoronavirus , COVID-19 , Infecções por Coronavirus/epidemiologia , Infecções por Coronavirus/prevenção & controle , Procedimentos Clínicos , Humanos , Hungria/epidemiologia , Controle de Infecções/métodos , Controle de Infecções/organização & administração , Inovação Organizacional , Pandemias/prevenção & controle , Pneumonia Viral/epidemiologia , Pneumonia Viral/prevenção & controle , SARS-CoV-2 , Ferimentos e Lesões/epidemiologia , Ferimentos e Lesões/cirurgia
15.
Clin Oral Implants Res ; 31(5): 417-430, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-31958166

RESUMO

OBJECTIVES: A randomized clinical trial was conducted to compare all three known static guided surgery protocols (pilot, partial, and full) with each other and with freehand surgery in terms of accuracy, under the same conditions. MATERIAL AND METHODS: A total of 207 implants of the same brand and type were placed in 101 partially edentulous volunteers in need of implantation in the mandible or maxilla or both. All cases were digitally planned, and the comparison of the planned and actual implant positions was performed using a medical image analysis software with dedicated algorithms. The primary outcome variable was angular deviation (AD, degrees). The secondary outcome variables were coronal global deviation (CGD, mm), apical global deviation (AGD, mm), and voxel overlap (VO, %). RESULTS: AD showed stepwise improvement in significant steps as the amount of guidance increased. The highest mean AD (7.03° ± 3.44) was obtained by freehand surgery and the lowest by fully guided surgery (3.04° ± 1.51). As for the secondary outcome variables, all guided protocols turned out to be significantly superior to freehand surgery, but they were not always significantly different from each other. CONCLUSIONS: As for the comparison that this study sought to perform, it can be said that the static guided approach significantly improves the accuracy of dental implant surgery as compared to freehand surgery. Furthermore, the results suggest that any degree of guidance yields better results than freehand surgery and that increasing the level of guidance increases accuracy.


Assuntos
Implantes Dentários , Cirurgia Assistida por Computador , Desenho Assistido por Computador , Implantação Dentária , Implantação Dentária Endóssea , Humanos , Maxila , Planejamento de Assistência ao Paciente
16.
Neurosci Lett ; 714: 134561, 2020 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-31629032

RESUMO

Clinical studies have shown that schizophrenia is accompanied by hypoalgesia. Accordingly, we have previously reported that a chronic schizophrenia-related rat substrain (Wisket) showed decreased acute heat pain sensitivity. The aim of the present study was to determine the mechanical pain sensitivity and the effects of opioid ligands in a chronic osteoarthritic pain model generated using Wisket rats. Our previous molecular biological studies indicated that the impairment in opioid and cannabinoid receptor functions observed in these animals did not explain their altered pain sensitivity. Therefore, we aimed to investigate another endogenous antinociceptive system, i.e., the oxytocinergic system (which is also implicated in schizophrenia) via the determination the brain-region specific oxytocin receptor mRNA expression in Wisket rats. Osteoarthritis was induced in male adult control Wistar rats without any interventions and in Wisket rats after juvenile social isolation and ketamine treatment. The degree of allodynia and the effects of systemic morphine or intrathecal endomorphin-1 administration were determined. Furthermore, the expression of the oxytocin receptor mRNA was assessed in different brain structures (prefrontal cortex, striatum, diencephalon, brainstem, and olfactory bulb). A lower degree of allodynia was observed in the Wisket group compared with control animals 1 and 2 weeks after the induction of osteoarthritis, which was accompanied by a comparable degree of edema. Systemically or intrathecally applied opioids caused similar time-response curves in both groups, with apparently shorter effects in Wisket animals. The expression of the oxytocin receptor mRNA was lower in most of the brain regions (with the exception of the diencephalon) investigated in Wisket rats vs. the control animals. In summary, both acute and chronic hypoalgesia (as nonspecific symptoms in patients with schizophrenia) can be simulated in Wisket animals as endophenotypes despite the impairment of the endogenous antinociceptive systems evaluated. Thus, this model might be an appropriate tool for further investigation of the molecular basis of altered pain perception in schizophrenia.


Assuntos
Encéfalo/metabolismo , Modelos Animais de Doenças , Nociceptividade/fisiologia , Osteoartrite/fisiopatologia , Ratos , Receptores de Ocitocina/genética , Esquizofrenia/fisiopatologia , Distúrbios Somatossensoriais/fisiopatologia , Analgésicos Opioides/farmacologia , Animais , Articulação do Tornozelo , Encéfalo/efeitos dos fármacos , Tronco Encefálico , Dor Crônica , Diencéfalo , Inibidores Enzimáticos , Antagonistas de Aminoácidos Excitatórios , Expressão Gênica , Hiperalgesia , Ácido Iodoacético , Ketamina , Masculino , Morfina/farmacologia , Neostriado , Nociceptividade/efeitos dos fármacos , Bulbo Olfatório , Oligopeptídeos/farmacologia , Osteoartrite/induzido quimicamente , Córtex Pré-Frontal , RNA Mensageiro/metabolismo , Receptores de Ocitocina/metabolismo , Esquizofrenia/genética , Esquizofrenia/metabolismo , Isolamento Social
17.
Oral Health Prev Dent ; 17(4): 309-316, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31093616

RESUMO

PURPOSE: The purpose of our study was to evaluate the impact of different irrigation fluid temperatures on intraosseous temperature increment during guided and freehand implant site preparation. MATERIALS AND METHODS: Bovine rib segments were used. Temperature was detected using K-type thermocouples. The studied groups were defined as combinations of the following: drilling speed (1500, 2000 RPM), drill diameter (2.0, 2.5, 3.0, 3.5 mm), surgical method (guided, freehand), and irrigation fluid temperature (10°C, 15°C, 20°C). The data were analysed with Kruskal-Wallis analysis of variance (ANOVA) and ANOVA, as appropriate. RESULTS: At 1500 RPM, guided drilling with 20°C irrigation fluid yielded temperature values exceeding the necrotic threshold (47°C) when performed with bits of 3.0 and 3.5 mm diameters. Meanwhile, 15°C irrigation managed to keep the mean increment below 8.0°C at the diameter of 3.5 mm for both guided and freehand surgery. However, 10°C irrigation cancelled every statistically significant difference between guided and freehand groups. At 2000 RPM and with 20°C irrigation, mean peak temperatures exceeded the necrotic threshold at the diameters 3.0 and 3.5 mm (guided) and 3.5 mm (freehand). When applying 10°C irrigation, though, all measurements indicated peak temperatures in the safe zone. CONCLUSION: Drillings at 1500 and 2000 RPM, in a guided setting, cause temperature elevations that exceed the necrotic threshold. A speed of 2000 RPM drilling may produce potentially harmful temperatures also in a freehand setting. 10°C and 15°C irrigation kept temperature increments in the safe zone at 2000 RPM and 1500 RPM, respectively.


Assuntos
Instrumentos Odontológicos , Temperatura Alta , Análise de Variância , Animais , Bovinos , Temperatura
18.
Orv Hetil ; 160(9): 338-342, 2019 Mar.
Artigo em Húngaro | MEDLINE | ID: mdl-30798624

RESUMO

INTRODUCTION: In our study, we analyzed one of the Hungarian population's most frequent injuries, the hip fracture, focusing mainly on the lateral femoral neck and the pertrochanteric fractures. According to the classification of the Swiss Association for Ostheosynthesis (AO), we focused on 31-A1 and 31-A2 fractures, the incidence of which increases by ageing. METHOD: Between 2010 and 2016, we analyzed the data of 1179 patients. All of the fractures were stabilized with intramedullary nails. 992 patients received Stryker Gamma3®, whereas 187 patients' fractures were solved with Synthes PFNA® nail. In all cases, closed reduction method was used with fluoroscopy on an extension table. The surgeries were done in general or epidural anesthesia and performed by traumatology residents or specialists using standard lateral exploration. Data were collected using GEPACS software and statistical analysis was done with MS Excel. RESULTS: Cut-out occurred in 33 cases (2,79%): out of that 21 (1.78%) were left sided and 12 were (1,01%) right sided. 29 (87.87%) patients were treated with Gamma3 nail, and in 4 (12,12%) cases PFNA nail was used. The average TAD-index was 18 mm. CONCLUSION: According to recommendations of the TAD-index value, when using dynamic hip screw, it should be 20 mm or lower. The average index value was 18 mm which was equal in the complicated and non-complicated groups. Our study shows that the cut-out is independent from the TAD-index value, thus this recommendation cannot be applied for intramedullary nails. Orv Hetil. 2019; 160(9): 338-342.


Assuntos
Pinos Ortopédicos , Parafusos Ósseos , Fixação Intramedular de Fraturas/instrumentação , Fraturas do Quadril/cirurgia , Humanos , Prognóstico , Resultado do Tratamento
20.
Orv Hetil ; 160(5): 172-178, 2019 Feb.
Artigo em Húngaro | MEDLINE | ID: mdl-30686031

RESUMO

INTRODUCTION: Chest injuries cause a significant number of pneumothorax (PTX) and hemothorax (HTX). The most commonly used treatment is chest-tube drainage. The position of the tube is a prime necessity to achieve adequate drainage. AIM: To analyze the duration of chest drainage at the occurrence of PTX and HTX. To find what the underlying cause of drainage insufficiency is and whether there is any relation between the surgical qualification needed to the procedure. METHOD: Clinical data of 110 injured patients from 2011 to 2015 were collected and retrospectively analyzed. In the case of tube breaking or drainage insufficiency it was investigated if repositioning, usage of new tubes or insertion of additional tubes resolved the drainage insufficiency. Authors investigated the location of the tube on x-ray and CT, and the connection between the drainage insufficiency and the surgical qualifications needed to the procedure. RESULTS: The average duration of chest drainage was 6.5 days. The duration of drainage was shorter by 1.9 days regarding the tube inserted in the middle section of the chest compared to the upper one and shorter by 1.2 days regarding the tube inserted in the lower section of the chest compared to the upper one. In the case of HTX, the duration of drainage was shorter by 2.8 days regarding the lower and by 3.6 days regarding the middle section compared to the upper position. Drainage insufficiency occurred in 30% of all cases. The duration of chest drainage was shorter after application of new tubes (9.5 days) than after reposition (10.2 days), but there was no significant difference. CONCLUSION: Chest injury is a wide entity, thus one standard protocol cannot be developed on the management of these injuries. Authors concluded that drainage duration decreases significantly if the position of the tube is in the middle or lower section of the chest. The high occurrence of drainage insufficiency was caused by inadequate tube positioning and tube breaking. The practical qualification of trauma surgeons did not play a significant role regarding the prevalence of drainage insufficiency rather if the tube positioning was appropriate. Orv Hetil. 2019; 160(5): 172-178.


Assuntos
Tubos Torácicos , Drenagem/métodos , Traumatismos Torácicos/diagnóstico por imagem , Traumatismos Torácicos/terapia , Adulto , Feminino , Hemotórax/diagnóstico por imagem , Hemotórax/etiologia , Hemotórax/terapia , Humanos , Hungria , Masculino , Pneumotórax/diagnóstico por imagem , Pneumotórax/etiologia , Pneumotórax/terapia , Estudos Retrospectivos , Traumatismos Torácicos/complicações , Cirurgia Torácica Vídeoassistida , Tomografia Computadorizada por Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA