Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 256
Filtrar
2.
J Cardiovasc Electrophysiol ; 35(4): 832-842, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38448797

RESUMO

INTRODUCTION: Cryoablation therapy for pulmonary vein isolation (PVI) to treat paroxysmal atrial fibrillation (PAF) is well established. A novel 28 mm cryoballoon system designed to operate under low pressure to safely reach a lower nadir temperature and maintain constant balloon size during cooling has not been prospectively studied in a large patient population for safety and efficacy. The FROZEN AF (NCT04133168) trial was an international multicenter, open-label, prospective, single-arm study on the safety and performance of a novel cryoballoon system for treatment of PAF. METHODS AND RESULTS: The study enrolled patients at 44 sites in 10 countries across North America, Europe, and Asia. Subjects were indicated for PVI treatment of PAF and had failed or were intolerant of one or more antiarrhythmic drugs. Procedural outcomes were defined based on the 2017 HRS consensus statement. Follow-up was performed at 7 days, 3, 6, and 12 months. Data are reported as mean ± SD or median (IQR). PVI was performed with a 28 mm cryoballoon in 325 drug refractory PAF patients. Complete PVI was achieved in 95.7% of patients. In cryoablation lesions longer than 60 s, 60.1% of PV isolations required only a single cryoballoon application. Procedure related complications included: phrenic nerve palsy [temporary 4 (1.2%), persistent 0 (0.0%)], cardiac tamponade/perforation 2 (0.6%), and air embolism 1 (0.3%). Freedom from documented atrial arrhythmia recurrence at 12 months was 79.9% (AF 82.7%, AFL 96.5%, AT 98.1%), antiarrhythmic drugs (AAD) were continued or re-initiated in 26.8% of patients after the 3-month blanking period. Additionally, an extension arm enrolled 50 pts for treatment with 28/31 mm variable size cryoballoon. A single temporary PNP occurred in this group, which resolved before discharge. Freedom from documented recurrence at 12 months in these pts was 82.0%. CONCLUSIONS: This novel cryoballoon may facilitate PVI to treat PAF, providing more options to address the variety of anatomies present in patients with PAF. This cryoballoon system proved to be safe and effective for treatment of patients with drug refractory or drug intolerant PAF.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Traumatismos Cardíacos , Veias Pulmonares , Humanos , Antiarrítmicos/uso terapêutico , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Fibrilação Atrial/epidemiologia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Criocirurgia/efeitos adversos , Criocirurgia/métodos , Traumatismos Cardíacos/etiologia , Estudos Prospectivos , Veias Pulmonares/cirurgia , Recidiva , Resultado do Tratamento
6.
J Am Coll Cardiol ; 83(5): 611-631, 2024 Feb 06.
Artigo em Inglês | MEDLINE | ID: mdl-38296406

RESUMO

Direct-to-consumer (D2C) wearables are becoming increasingly popular in cardiovascular health management because of their affordability and capability to capture diverse health data. Wearables may enable continuous health care provider-patient partnerships and reduce the volume of episodic clinic-based care (thereby reducing health care costs). However, challenges arise from the unregulated use of these devices, including questionable data reliability, potential misinterpretation of information, unintended psychological impacts, and an influx of clinically nonactionable data that may overburden the health care system. Further, these technologies could exacerbate, rather than mitigate, health disparities. Experience with wearables in atrial fibrillation underscores these challenges. The prevalent use of D2C wearables necessitates a collaborative approach among stakeholders to ensure effective integration into cardiovascular care. Wearables are heralding innovative disease screening, diagnosis, and management paradigms, expanding therapeutic avenues, and anchoring personalized medicine.


Assuntos
Custos de Cuidados de Saúde , Humanos , Reprodutibilidade dos Testes
7.
Ann Noninvasive Electrocardiol ; 29(1): e13097, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-37997698

RESUMO

The ECG diagnosis of LVH is predominantly based on the QRS voltage criteria. The classical paradigm postulates that the increased left ventricular mass generates a stronger electrical field, increasing the leftward and posterior QRS forces, reflected in the augmented QRS amplitude. However, the low sensitivity of voltage criteria has been repeatedly documented. We discuss possible reasons for this shortcoming and proposal of a new paradigm. The theoretical background for voltage measured at the body surface is defined by the solid angle theorem, which relates the measured voltage to spatial and non-spatial determinants. The spatial determinants are represented by the extent of the activation front and the distance of the recording electrodes. The non-spatial determinants comprise electrical characteristics of the myocardium, which are comparatively neglected in the interpretation of the QRS patterns. Various clinical conditions are associated with LVH. These conditions produce considerable diversity of electrical properties alterations thereby modifying the resultant QRS patterns. The spectrum of QRS patterns observed in LVH patients is quite broad, including also left axis deviation, left anterior fascicular block, incomplete and complete left bundle branch blocks, Q waves, and fragmented QRS. Importantly, the QRS complex can be within normal limits. The new paradigm stresses the electrophysiological background in interpreting QRS changes, i.e., the effect of the non-spatial determinants. This postulates that the role of ECG is not to estimate LV size in LVH, but to understand and decode the underlying electrical processes, which are crucial in relation to cardiovascular risk assessment.


Assuntos
Sistema de Condução Cardíaco , Hipertrofia Ventricular Esquerda , Humanos , Hipertrofia Ventricular Esquerda/diagnóstico , Eletrocardiografia , Arritmias Cardíacas , Bloqueio de Ramo
8.
J Cardiovasc Electrophysiol ; 35(3): 583-591, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37811553

RESUMO

BACKGROUND: Height, left ventricular (LV) size, and sex were proposed as additional criteria for patient selection for cardiac resynchronization therapy (CRT) but their connections with the QRS complex in left bundle branch block (LBBB) are little investigated. We evaluated these. METHODS: Among patients with "true" LBBB, QRS duration (QRSd) and amplitude, and LV hypertrophy indices, were correlated with patient's height and LV mass, and compared between sexes. RESULTS: In this study cohort (n = 220; 60 ± 12 years; left ventricular ejection fraction [LVEF] 21 ± 7%; mostly New York Heart Association II-III, QRSd 165 ± 19 ms; 57% female; 70% responders [LVEF increased ≥5%]), LV mass was increased in all patients. QRS amplitude did not correlate with LV mass or height in any individual lead or with Sokolow-Lyon or Cornell-Lyon indices. QRSd did not correlate with height. In contrast, QRSd correlated strongly with LV mass (r = .51). CRT response rate was greater in women versus men (84% vs. 58%, p < .001) despite shorter QRSd [7% shorter (p < .0001)]. QRSd normalized for height resulted in a 2.7% and for LV mass 24% greater index in women. CONCLUSION: True LBBB criteria do not exclude HF patients with increased LV mass. QRS amplitudes do not correlate with height or LV mass. Height does not affect QRSd. However, QRSd correlates with LV size. QRSd normalized for LV mass results in 24% greater value in women in the direction of sex-specific responses. LV mass may be a significant nonelectrical modifier of QRSd for CRT.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Masculino , Humanos , Feminino , Bloqueio de Ramo/diagnóstico , Bloqueio de Ramo/terapia , Volume Sistólico/fisiologia , Função Ventricular Esquerda/fisiologia , Resultado do Tratamento , Eletrocardiografia , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Terapia de Ressincronização Cardíaca/métodos
9.
medRxiv ; 2023 Dec 06.
Artigo em Inglês | MEDLINE | ID: mdl-38106113

RESUMO

Background: Studies have reported that female sex predicts superior cardiac resynchronization therapy (CRT) response. One theory is that this association is related to smaller female heart size, thus increased "relative dyssynchrony" at given QRS durations (QRSd). Objective: To investigate the mechanisms of sex-specific CRT response relating to heart size, relative dyssynchrony, cardiomyopathy type, QRS morphology, and other patient characteristics. Methods: A post-hoc analysis of the MORE-CRT MPP trial (n=3739, 28% female), with a sub-group analysis of patients with non-ischaemic cardiomyopathy (NICM) and left bundle branch block (LBBB) (n=1308, 41% female) to control for confounding characteristics. A multivariable analysis examined predictors of response to 6 months of conventional CRT, including sex and relative dyssynchrony, measured by QRSd/LVEDV (left ventricular end-diastolic volume). Results: Females had a higher CRT response rate than males (70.1% vs. 56.8%, p<0.0001). Subgroup analysis: Regression analysis of the NICM LBBB subgroup identified QRSd/LVEDV, but not sex, as a modifier of CRT response (p<0.0039). QRSd/LVEDV was significantly higher in females (0.919) versus males (0.708, p<0.001). CRT response was 78% for female patients with QRSd/LVEDV>median value, compared to 68% < median value (p=0.012). Association between CRT response and QRSd/LVEDV was strongest at QRSd<150ms. Conclusions: In the NICM LBBB population, increased relative dyssynchrony in females, who have smaller heart sizes than their male counterparts, is a driver of sex-specific CRT response, particularly at QRSd <150ms. Females may benefit from CRT at a QRSd <130ms, opening the debate on whether sex-specific QRSd cut-offs or QRS/LVEDV measurement should be incorporated into clinical guidelines.

13.
Europace ; 25(9)2023 08 02.
Artigo em Inglês | MEDLINE | ID: mdl-37622591

RESUMO

This reviews the transition of remote monitoring of patients with cardiac electronic implantable devices from curiosity to standard of care. This has been delivered by technology evolution from patient-activated remote interrogations at appointed intervals to continuous monitoring that automatically flags clinically actionable information to the clinic for review. This model has facilitated follow-up and received professional society recommendations. Additionally, continuous monitoring has provided a new level of granularity of diagnostic data enabling extension of patient management from device to disease management. This ushers in an era of digital medicine with wider applications in cardiovascular medicine.


Assuntos
Fármacos Cardiovasculares , Humanos , Eletrônica , Coração , Tecnologia , Gerenciamento Clínico
14.
Heart Rhythm ; 20(11): 1489-1490, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37558080
15.
Lancet ; 402(10408): 1147-1157, 2023 09 30.
Artigo em Inglês | MEDLINE | ID: mdl-37634520

RESUMO

BACKGROUND: Continuous automatic optimisation of cardiac resynchronisation therapy (CRT), stimulating only the left ventricle to fuse with intrinsic right bundle conduction (synchronised left ventricular stimulation), might offer better outcomes than conventional CRT in patients with heart failure, left bundle branch block, and normal atrioventricular conduction. This study aimed to compare clinical outcomes of adaptive CRT versus conventional CRT in patients with heart failure with intact atrioventricular conduction and left bundle branch block. METHODS: This global, prospective, randomised controlled trial was done in 227 hospitals in 27 countries across Asia, Australia, Europe, and North America. Eligible patients were aged 18 years or older with class 2-4 heart failure, an ejection fraction of 35% or less, left bundle branch block with QRS duration of 140 ms or more (male patients) or 130 ms or more (female patients), and a baseline PR interval 200 ms or less. Patients were randomly assigned (1:1) via block permutation to adaptive CRT (an algorithm providing synchronised left ventricular stimulation) or conventional biventricular CRT using a device programmer. All patients received device programming but were masked until procedures were completed. Site staff were not masked to group assignment. The primary outcome was a composite of all-cause death or intervention for heart failure decompensation and was assessed in the intention-to-treat population. Safety events were collected and reported in the intention-to-treat population. This study is registered with ClinicalTrials.gov, NCT02205359, and is closed to accrual. FINDINGS: Between Aug 5, 2014, and Jan 31, 2019, of 3797 patients enrolled, 3617 (95·3%) were randomly assigned (1810 to adaptive CRT and 1807 to conventional CRT). The futility boundary was crossed at the third interim analysis on June 23, 2022, when the decision was made to stop the trial early. 1568 (43·4%) of 3617 patients were female and 2049 (56·6%) were male. Median follow-up was 59·0 months (IQR 45-72). A primary outcome event occurred in 430 of 1810 patients (Kaplan-Meier occurrence rate 23·5% [95% CI 21·3-25·5] at 60 months) in the adaptive CRT group and in 470 of 1807 patients (25·7% [23·5-27·8] at 60 months) in the conventional CRT group (hazard ratio 0·89, 95% CI 0·78-1·01; p=0·077). System-related adverse events were reported in 452 (25·0%) of 1810 patients in the adaptive CRT group and 440 (24·3%) of 1807 patients in the conventional CRT group. INTERPRETATION: Compared with conventional CRT, adaptive CRT did not significantly reduce the incidence of all-cause death or intervention for heart failure decompensation in the included population of patients with heart failure, left bundle branch block, and intact AV conduction. Death and heart failure decompensation rates were low with both CRT therapies, suggesting a greater response to CRT occurred in this population than in patients in previous trials. FUNDING: Medtronic.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Humanos , Masculino , Feminino , Bloqueio de Ramo/etiologia , Bloqueio de Ramo/terapia , Estudos Prospectivos , Resultado do Tratamento , Terapia de Ressincronização Cardíaca/efeitos adversos , Terapia de Ressincronização Cardíaca/métodos , Volume Sistólico , Eletrocardiografia
16.
J Electrocardiol ; 81: 85-93, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37647776

RESUMO

The ECG diagnosis of LVH is predominantly based on the QRS voltage criteria, i.e. the increased QRS complex amplitude in defined leads. The classical ECG diagnostic paradigm postulates that the increased left ventricular mass generates a stronger electrical field, increasing the leftward and posterior QRS forces. These increased forces are reflected in the augmented QRS amplitude in the corresponding leads. However, the clinical observations document increased QRS amplitude only in the minority of patients with LVH. The low sensitivity of voltage criteria has been repeatedly documented. We discuss possible reasons for this shortcoming and proposal of a new paradigm.


Assuntos
Eletrocardiografia Ambulatorial , Hipertrofia Ventricular Esquerda , Humanos , Hipertrofia Ventricular Esquerda/diagnóstico , Eletrocardiografia , Sistema de Condução Cardíaco
17.
J Arrhythm ; 39(3): 250-302, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-37324757

RESUMO

Remote monitoring is beneficial for the management of patients with cardiovascular implantable electronic devices by impacting morbidity and mortality. With increasing numbers of patients using remote monitoring, keeping up with higher volume of remote monitoring transmissions creates challenges for device clinic staff. This international multidisciplinary document is intended to guide cardiac electrophysiologists, allied professionals, and hospital administrators in managing remote monitoring clinics. This includes guidance for remote monitoring clinic staffing, appropriate clinic workflows, patient education, and alert management. This expert consensus statement also addresses other topics such as communication of transmission results, use of third-party resources, manufacturer responsibilities, and programming concerns. The goal is to provide evidence-based recommendations impacting all aspects of remote monitoring services. Gaps in current knowledge and guidance for future research directions are also identified.

18.
Heart Rhythm ; 20(9): e92-e144, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37211145

RESUMO

Remote monitoring is beneficial for the management of patients with cardiovascular implantable electronic devices by impacting morbidity and mortality. With increasing numbers of patients using remote monitoring, keeping up with higher volume of remote monitoring transmissions creates challenges for device clinic staff. This international multidisciplinary document is intended to guide cardiac electrophysiologists, allied professionals, and hospital administrators in managing remote monitoring clinics. This includes guidance for remote monitoring clinic staffing, appropriate clinic workflows, patient education, and alert management. This expert consensus statement also addresses other topics such as communication of transmission results, use of third-party resources, manufacturer responsibilities, and programming concerns. The goal is to provide evidence-based recommendations impacting all aspects of remote monitoring services. Gaps in current knowledge and guidance for future research directions are also identified.


Assuntos
Desfibriladores Implantáveis , Tecnologia de Sensoriamento Remoto , Humanos
19.
Europace ; 25(5)2023 05 19.
Artigo em Inglês | MEDLINE | ID: mdl-37208301

RESUMO

Remote monitoring is beneficial for the management of patients with cardiovascular implantable electronic devices by impacting morbidity and mortality. With increasing numbers of patients using remote monitoring, keeping up with higher volume of remote monitoring transmissions creates challenges for device clinic staff. This international multidisciplinary document is intended to guide cardiac electrophysiologists, allied professionals, and hospital administrators in managing remote monitoring clinics. This includes guidance for remote monitoring clinic staffing, appropriate clinic workflows, patient education, and alert management. This expert consensus statement also addresses other topics such as communication of transmission results, use of third-party resources, manufacturer responsibilities, and programming concerns. The goal is to provide evidence-based recommendations impacting all aspects of remote monitoring services. Gaps in current knowledge and guidance for future research directions are also identified.


Assuntos
Monitorização Fisiológica , Telemetria , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA