Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
Eur J Dent ; 2024 May 02.
Artigo em Inglês | MEDLINE | ID: mdl-38698613

RESUMO

OBJECTIVE: The aim of this study was to evaluate the accuracy of the Root ZX II (RZX), Raypex 6 (RAY), EPex Pro (EPEX), and CanalPro (CNP) electronic foramen locators (EFLs) in different foraminal morphologies (fully formed foramen, immature foramen with parallel walls, and immature foramen with divergent walls); this article also evaluated the influence of different penetration levels (0.0 mm and -1.0 mm). MATERIALS AND METHODS: Thirty single-rooted human premolars were accessed and had their cervical/middle thirds prepared with SX ProTaper files. The apical foramens (AF) were standardized to 250 µm and the initial root canal length (RCL1) was measured under 16x magnification with aid of a digital caliper. Using the alginate model, electronic measurements (EM) were taken 1.0 mm up to AF (EM1/-1) and at AF (EM1/0), always using adjusted hand K-files. The root apexes were then cross-sectioned 3.0 mm from the foramen; then, new RCL (RCL2) and electronic measurements were performed (EM2/-1 and EM2/0.0). Finally, retropreparations were performed with instruments SX ProTaper files introduced 4.0 mm in the apicocervical direction. Then new RCL (RCL3) and electronic measurements (EM3/-1 and EM3/0) were performed. STATISTICAL ANALYSIS: Values were tabulated and tested for normality using the Shapiro-Wilk test, which yielded nonparametric distributions of the data. Data were subjected to the Kruskal-Wallis and Dunn tests to estimate possible differences between devices as a function of foramen morphology and/or apical limit. The significance level was set at 5.0%. RESULTS: In general, the EFLs were accurate in determining the RCL. Statistically significant differences were observed between EPEX and RAY at 0.0, when measuring the divergent AF canals (p < 0.05). Regarding the different foramen morphologies in each EFL, RZX and EPEX showed no interference (p > 0.05), whereas RAY and CNP had lower accuracy levels at 0.0 with divergent AF (p < 0.05). CONCLUSION: The four devices evaluated are accurate to determine the RCL in the conditions tested. The apical limit of penetration did not have significant influence on their accuracy. Conversely, the presence of divergence in the AF walls negatively influenced de RAY and CNP precisions at the foraminal level.

2.
Clin Oral Investig ; 26(2): 1293-1298, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34406466

RESUMO

OBJECTIVE: This study aimed to evaluate the accuracy of the auto apical function in the maintenance of the apical limit of instrumentation during glide path procedures when associated to OGP kinematics of Tri Auto ZX2, compared to the continuous rotation of the same motor, as well as Root ZX II and VDW Gold. MATERIALS AND METHODS: Forty-eight extracted human mandibular single-rooted premolars were selected. After endodontic access, cervical pre-flaring was performed using size 30, 0.10 taper rotary instruments, and the apical foramen size was standardized to 200 µm. Teeth were randomly divided into four groups (n = 12) according to the device and kinematics. For all the groups, the Auto Apical Stop function (AAS) was set to the 0.0 mark. Glide path instruments size 25, .01 taper were activated inside the canals until the apical limit was reached. Then, the files were fixed with cyanoacrylate to the teeth and decoupled from the equipment. Data were statistically analyzed in GraphPad Prism 6.0 software with the significance set at 5% (Kruskal-Wallis tests). RESULTS: There was no difference in the mean deviation between the groups. No significant difference was found among the groups when the distributions and percentages of differences between the file tip and the apical foramen were compared (P > 0.05). CONCLUSION: The use of auto apical function at the 0.0 mark of all tested devices provided an adequate control of the apical limit during glide path preparation. Foramen locating accuracy of Tri Auto ZX2 in OGP kinematics was similar to those of Tri Auto ZX2, Root ZX II, and VDW Gold in continuous kinematics. CLINICAL RELEVANCE: Clinical strategies in canal negotiation and glide path as OGP motion associated to electronic foramen locators could reduce iatrogenic risk of deviation and file fractures and create an easier initial preparation to facilitate endodontic procedures.


Assuntos
Cavidade Pulpar , Preparo de Canal Radicular , Fenômenos Biomecânicos , Eletrônica , Humanos , Odontometria , Ápice Dentário
3.
J Biomed Mater Res B Appl Biomater ; 109(3): 348-357, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-32830897

RESUMO

To assess the effect of biodentine (BD) and MTA-angelus (MTA) on biocompatibility, BMP2, BMP4, and osteocalcin (OC) expression. Subcutaneously implanted tubes of four groups (MTA, BD, Control, and Sham) were kept over 15, 30, and 60 days; histological analyses were performed using H&E and Von Kossa; ELISA quantified IL-1ß and IL-8 expression; and qRT-PCR verified gene expression of BMPs and OC. Sham showed slight changes in profile/intensity of inflammatory infiltrate in all periods. Control had an inflammatory score significantly higher than Sham at 15 days (p < .05). BD revealed a similar inflammatory response to Sham, without significant changes over periods. MTA group exhibited an increase in chronic inflammatory profile at 30 days, with significant reduction at 60 days, when compared to Sham (p < .05). At 30/60 days, experimental groups presented birefringent areas. At 30/60 days, BD and MTA significantly increase IL-1ß compared to Control, whereas an increase in IL-8 was observed only in BD. At 30/60 days, BD produces an expression of BMP2 whereas MTA influenced BMP4 and OC. Materials tested are biocompatible and they have osteoinductive activity; the materials influenced the expression of the tested mediators differently, suggesting different affinities with the substrate and the dental substrates.


Assuntos
Materiais Biocompatíveis/farmacologia , Bismuto/farmacologia , Proteína Morfogenética Óssea 2/biossíntese , Proteína Morfogenética Óssea 4/biossíntese , Calcificação Fisiológica/efeitos dos fármacos , Compostos de Cálcio/farmacologia , Óxidos/farmacologia , Materiais Restauradores do Canal Radicular/farmacologia , Silicatos/farmacologia , Animais , Masculino , Ratos , Ratos Wistar
4.
J Contemp Dent Pract ; 22(11): 1232-1236, 2021 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-35343446

RESUMO

AIM AND OBJECTIVE: To evaluate morphologic changes in the main foramen after enlargement with four different systems. MATERIALS AND METHODS: One hundred and twenty canals (buccal of maxillary molars and mesial of mandibular molars) with patency and apical foramen ≤200 µm were included. These apical foramina were photographed and then randomly divided into four experimental groups, according to the ProDesign Logic (PDL), ProDesign R (PDR), twisted file adaptive (TFA), and WaveOne Gold (WOG) systems, all of which were composed of three sequential instruments (Glidepath, #25 and #35). Root canals were prepared 1 mm beyond the main foramen (n = 30). The specimens were photographed again to capture intermediate (#25) and final enlargement (#35) images. These were analyzed using an image software that allowed comparison of the enlarged area and shape of the main foramen. RESULTS: In the Intragroup comparison, the Friedman's test showed a statistical difference between each phase of foramen enlargement (p <0.05). In the intergroup comparison, the percentage of foramen enlargement showed statistically significant difference between Groups PDR and TFA only in the analysis from #25 to #35, with 42.88 and 67.34% of foramen area widening, respectively. Relative to the final foramen shape, 81.7% were observed to be circular, 17.5% oval, and 0.8% flattened. CONCLUSION: Our results showed that foramen enlargement allowed an increase in area, maintained the circular shape of the foramen in the majority of cases, irrespective of the system used, and was a feasible option for use during preparation of the root canal system.


Assuntos
Níquel , Preparo de Canal Radicular , Cavidade Pulpar/anatomia & histologia , Cavidade Pulpar/diagnóstico por imagem , Desenho de Equipamento , Preparo de Canal Radicular/métodos , Titânio
5.
J Contemp Dent Pract ; 20(4): 405-408, 2019 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-31308268

RESUMO

AIM: This study was aimed to analyze, through an ex vivo test, the durability of two rotary systems used in curved root canals of extracted molars. MATERIALS AND METHODS: At first, 150 upper and lower molars were selected, presenting curvature at least in one of the root canals. They underwent access cavity and radiographed with a # 15 file into the canal to determine their maximum curvatures, classified as schneider. The teeth with one or more curved canals were included in this study. Finally, 120 curved root canals were statistically divided into six sets of 20 curved canals. Two rotatory systems, K3 XF (RCS sequence) and twisted file (Large Kit), both treatment R-Phase, were analyzed. Three kits were used for each system, each one instrumented one of the six sets of 20 curved canals. File deformations were noted, and the files were used until a fracture occurs or until completion of 20 canals preparation. Fractured files before the end of the instrumentation of the 20 canals were replaced, continuing the full instrumentation set. Statistical analysis was performed by analysis of variance (ANOVA) (p >0.05), and a qualitative assessment was also made. RESULTS: It was found that there was no statistical difference between the K3 XF and TF systems regarding fracture. CONCLUSION: There were no statistical differences between the K3 XF systems in the RCS sequence and the twisted file kit Large system, as to the number of instrumented conduits to the deformation or fracture. CLINICAL SIGNIFICANCE: The findings of this study reinforce that, it is necessary to choose files that support curved roots preventing accidents inside the root canal. Therefore, it is important for professionals to have knowledge and command of these protocols to obtain more satisfactory results.


Assuntos
Cavidade Pulpar , Preparo de Canal Radicular , Dente Molar , Tratamento do Canal Radicular , Rotação , Titânio
6.
J Contemp Dent Pract ; 19(9): 1087-1094, 2018 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-30287709

RESUMO

AIM: The purpose of this study was to evaluate the influence of widening the apical root canal preparation (RCP) on the efficiency of different ethylenediaminetetraacetic acid (EDTA) agitation protocols on smear layer removal: EDTA; EDTA + Easy Clean in rotary movement (ECROT); EDTA + Easy Clean in reciprocating movement (ECREC); and EDTA + Passive ultrasonic irrigation (PUI). MATERIALS AND METHODS: A total of 80 mandibular premolars had their crowns sectioned and then were divided into two groups according to widening: size 25 or 40, 0.08 taper. Sequentially they were once again allocated to subgroups according to the agitation protocol performing eight experimental groups (n = 10). Ten additional teeth were prepared for controls (C+/C-). The specimens were then submitted to the cleaning protocols and thereafter cleaved and microphotographed by variable pressure scanning electron microscopy (SEM) at previously determined points along their root thirds (750*). Scores were attributed to the images, and data were analyzed by the Kruskal-Wallis, Student-Newman-Keuls and Friedman tests. RESULTS: A higher widening was observed to have a positive influence on cleaning efficiency offering significant differences in global and apical third evaluations (p < 0.05). Relative to the agitation, significant differences were observed mainly in the apical third, with PUI and ECROT providing the best results (p < 0.05); no difference for C+ was observed when higher widening was employed. CONCLUSION: A greater widening of the apical third provided a significant improvement in the action of the agitation/activation protocols. Moreover, the PUI and ECROT activation methods were shown to be superior to the use of EDTA solely, particularly in the apical third. CLINICAL SIGNIFICANCE: The findings of this study reinforce the need for clinical use of additional methods to complement cleaning. Therefore, it is important for professionals to have knowledge and command of these protocols to obtain more satisfactory results.


Assuntos
Cavidade Pulpar/ultraestrutura , Ácido Edético/administração & dosagem , Microscopia Eletrônica de Varredura , Irrigantes do Canal Radicular/administração & dosagem , Preparo de Canal Radicular/métodos , Irrigação Terapêutica/métodos , Ápice Dentário , Dente Pré-Molar , Humanos , Mandíbula , Camada de Esfregaço , Ultrassom
7.
Scanning ; 37(2): 126-30, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25652816

RESUMO

To compare the time dispensed and the surface characteristics when a root-end resection was performed with a surgical ultrasonic device (VarioSurg, NSK, Japan) or with a Zekrya bur. Forty distal roots of freshly extracted mandibular molars were selected and divided into four different groups: (G1) stainless steel insert with ultrasound; (G2) diamond insert with ultrasound; (G3) stainless steel and diamond inserts with ultrasound, and (G4) Zekrya burs. The time required for the root-end resection was timed and the surface characteristics were evaluated via scanning electronic microscopy. The median times for the root-end resections were: 115.9 s for G1, 249.8 s for G2, 112.7 s for G3, and 7.44 s for G4, the latter presented a smoother root-end surface. There was no statistically significant difference in the comparisons between G3 group and G4 group (Zekrya burs). The other groups where the root-end resections were with ultrasonic devices proportioned a prolonged time to resection with irregular surfaces.


Assuntos
Apicectomia/métodos , Microscopia Eletrônica de Varredura , Propriedades de Superfície , Ápice Dentário/diagnóstico por imagem , Ápice Dentário/cirurgia , Dente Molar/diagnóstico por imagem , Dente Molar/cirurgia , Tempo , Ultrassonografia
8.
Artigo em Inglês | MEDLINE | ID: mdl-17703968

RESUMO

OBJECTIVE: The aim of this study was to perform a comparative analysis of precision of 3 apex locators: Root ZX, Elements Diagnostic Unit and Apex Locator, and RomiAPEX D-30. STUDY DESIGN: Forty extracted single-rooted human teeth were selected. After endodontic access, measurement of the anatomical tooth length was visually performed by insertion of a K-file size 10 until its tip could be observed at the apical foramen with aid of a light microscope at 8x magnification. Following, the teeth were placed in a plastic box with alginate and electronically measured with the 3 apex locators at 1-mm short of the apical foramen. RESULTS: The results revealed a precision rate of 97.5% for Root ZX, 95% for Elements Diagnostic Unit and Apex Locator, and 92.5% for RomiAPEX D-30, with no statistically significant difference between them (chi-square test, P > .05). CONCLUSION: The results confirm that all these electronic devices can accurately determine the root canal length within 1 mm from the apical constriction.


Assuntos
Instrumentos Odontológicos , Cavidade Pulpar/anatomia & histologia , Odontometria/instrumentação , Preparo de Canal Radicular/instrumentação , Ápice Dentário/anatomia & histologia , Eletrônica Médica , Humanos , Reprodutibilidade dos Testes
9.
J Endod ; 33(4): 484-7, 2007 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-17368345

RESUMO

This study evaluated the time, occurrence of fracture, and quality of apical cavity preparation with three different ultrasonic diamond tips: Satelec, Trinity, and a new type, CVD (chemical vapor deposition), using scanning electron microscopy (SEM) analysis. Thirty human single-rooted premolars were selected, submitted to apicectomy, and prepared with ultrasonic tips; impressions were then obtained. The presence of fractures was evaluated on the impressions, and the quality of preparation was evaluated by SEM analysis of teeth and scoring by two examiners. The group prepared with the CVD tips exhibited the shorter preparation time and did not present fractures. There was no statistically significant difference in the quality of preparation for the three tips. The three brands of ultrasonic tips produced adequate grinding without altering the morphology of the apical foramen.


Assuntos
Cavidade Pulpar/ultraestrutura , Preparo de Canal Radicular/instrumentação , Ápice Dentário/ultraestrutura , Terapia por Ultrassom/instrumentação , Apicectomia , Dente Pré-Molar/ultraestrutura , Cavidade Pulpar/lesões , Diamante , Desenho de Equipamento , Humanos , Teste de Materiais , Microscopia Eletrônica de Varredura , Propriedades de Superfície , Fatores de Tempo , Ápice Dentário/lesões
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA