Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
Expert Rev Mol Diagn ; 21(3): 333-342, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-33849372

RESUMO

Background: Here we compare the performance of the high-throughput BD COR System (COR) to the Viper LT System (Viper) using the BD Onclarity HPV assay.Research Design and Methods: Remnant clinical specimens, contrived specimens in SurePath (BD) and PreservCyt (Hologic) media, and prospective clinical specimens in BD Cervical Brush Diluent (CBD) were tested. Outcomes included intra-laboratory agreement of Onclarity results on COR and inter-system agreement between COR and Viper.Results: Onclarity reproducibility on COR resulted in standard deviation and correlation of variation of Ct values ranging from 0.14 to 1.98 and 0.49% to 2.15%, respectively, for contrived specimens, and 0.9-3.08 and 2.89-9.21%, respectively, for clinical specimens. In the COR and Viper clinical agreement study, OPA for Onclarity ranged from 97.1%-98.9%, depending on the collection media type. PPA values for pooled, HPV(+) specimens at low positive (C95), and moderate positive (3XC95) target concentrations were ≥95.0% and 100%, respectively; PPA values associated with HPV 16, 18, 31, 45, 33/58, 52, 35/39/68, 51, and 56/59/66, individually, ranged from 93.8%-100%.Conclusions: Onclarity performance on COR is equivalent to Viper, and is accurate and reproducible for detection of all high-risk HPV genotypes, with a throughput of 330 results from a single 8-hour shift.


Assuntos
Infecções por Papillomavirus , Neoplasias do Colo do Útero , Feminino , Humanos , Papillomaviridae/genética , Infecções por Papillomavirus/diagnóstico , Estudos Prospectivos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Neoplasias do Colo do Útero/diagnóstico
4.
BMC Infect Dis ; 15: 544, 2015 Nov 25.
Artigo em Inglês | MEDLINE | ID: mdl-26607224

RESUMO

BACKGROUND: Identification of human papillomavirus (HPV) DNA in cervical tissue is important for understanding cervical carcinogenesis and for evaluating cervical cancer prevention approaches. However, HPV genotyping using formalin-fixed, paraffin-embedded (FFPE) tissues is technically challenging. We evaluated the performance of four commonly used genotyping methods on FFPE cervical specimens conducted in different laboratories and compared to genotyping results from cytological samples. METHODS: We included 60 pairs of exfoliated-cell and FFPE specimens from women with histologically confirmed cervical intraepithelial lesions grade 2 or 3. Cytology specimens were genotyped using the Linear Array assay. Four expert laboratories processed tissue specimens using different preparation methods and then genotyped the resultant sample preparations using four different HPV genotyping methods: SPF10-PCR DEIA LiPA25 (version 1), Inno-LiPA, Linear Array and the Onclarity assay. Percentage agreement, kappa statistics and McNemar's chi-square were calculated for each comparison of different methods and specimen types. RESULTS: Overall agreement with respect to carcinogenic HPV status for FFPE samples between different methods was: 81.7, 86.7 and 91.7% for Onclarity versus Inno-LiPA, Linear Array and SPF-LiPA25, respectively; 81.7 and 85.0% for Linear Array versus Inno-LiPA and SPF-LiPA25, respectively; and 86.7% for SPF-LiPA25 versus Inno-LiPA. Type-specific agreement was >88.3% for all pair-wise comparisons. Comparisons with cytology specimens resulted in overall agreements from 80 to 95% depending on the method and type-specific agreement was >90% for most comparisons. CONCLUSIONS: Our data demonstrate that the four genotyping methods run by expert laboratories reliably detect HPV DNA in FFPE specimens with some variation in genotype-specific detection.


Assuntos
Colo do Útero/patologia , Colo do Útero/virologia , DNA Viral/isolamento & purificação , Técnicas de Genotipagem , Papillomaviridae/genética , Inclusão em Parafina , Adulto , Feminino , Genótipo , Humanos , Pessoa de Meia-Idade , Tipagem Molecular/métodos , Papillomaviridae/isolamento & purificação , Reação em Cadeia da Polimerase/métodos , Manejo de Espécimes/métodos , Manejo de Espécimes/normas , Neoplasias do Colo do Útero/patologia , Neoplasias do Colo do Útero/virologia , Displasia do Colo do Útero/patologia , Displasia do Colo do Útero/virologia
5.
Gynecol Oncol ; 138(3): 573-8, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26148763

RESUMO

BACKGROUND: In US cervical screening, immediate colposcopy is recommended for women with HPV-positive ASC-US (equivocal) cytology. We evaluated whether partial typing by Onclarity™ (BD) might identify HPV-positive women with low enough CIN3+ risk to permit 1-year follow-up instead. METHODS: The NCI-Kaiser Permanente Northern California Persistence and Progression cohort includes a subset of 13,890 women aged 21+ with HC2 (Qiagen)-positive ASC-US at enrollment; current median follow-up is 3.0years. Using stratified random sampling, we typed 2079 archived enrollment specimens including 329 women subsequently diagnosed with CIN3+, 563 with CIN2, and 1187 with

Assuntos
Células Escamosas Atípicas do Colo do Útero/virologia , Papillomaviridae/genética , Infecções por Papillomavirus/virologia , Lesões Intraepiteliais Escamosas Cervicais/virologia , Displasia do Colo do Útero/virologia , Neoplasias do Colo do Útero/virologia , Adulto , Células Escamosas Atípicas do Colo do Útero/patologia , Feminino , Genótipo , Humanos , Lesões Intraepiteliais Escamosas Cervicais/patologia , Neoplasias do Colo do Útero/patologia , Esfregaço Vaginal/métodos , Adulto Jovem
6.
Am J Clin Pathol ; 142(1): 43-50, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24926084

RESUMO

OBJECTIVES: To compare the performance of the BD Onclarity HPV Assay (BD Diagnostics, Sparks, MD) in BD SurePath liquid-based cytology media with that of Hybrid Capture 2 (HC2, Qiagen, Germantown, MD) samples co-collected in specimen transport medium in an adjudicated patient cohort. METHODS: The performance of the BD Onclarity HPV Assay using BD SurePath media was compared with that of HC2 samples co-collected in specimen transport medium using 541 archived samples from a multicenter US clinical trial with histologically adjudicated cervical biopsy specimens. RESULTS: The sensitivity for cervical intraepithelial neoplasia (CIN) 2 positivity (n - 104) was 90.4% (95% confidence interval [CI], 83-95) and 93.3% (95% CI, 87-97) and specificity was 76.9% (95% CI, 73-81) and 77.8% (95% CI, 74-82) for the BD assay and HC2, respectively. Nine cases of CIN 2+ had results discordant with the high-risk HPV assay. All were found to have been correctly classified with the BD assay using a novel WAVE denaturing high-performance liquid chromatography double-stranded DNA sequencing method. CONCLUSIONS: The clinical performance of The BD Onclarity HPV Assay with respect to histology end points was similar to HC2. Moreover, discordant analysis revealed improved performance of the BD assay with respect to ability to provide extended genotyping information and lack of cross-reactivity with low-risk HPV types associated with cellular abnormalities. The relative risks for CIN 3 disease for HPV 31 and HPV 33/58 (combined) were comparable to that of HPV 18 in this population, suggesting that these genotypes may warrant monitoring in future studies.


Assuntos
Colo do Útero/virologia , Papillomaviridae/isolamento & purificação , Infecções por Papillomavirus/diagnóstico , Kit de Reagentes para Diagnóstico/normas , Displasia do Colo do Útero/diagnóstico , Neoplasias do Colo do Útero/diagnóstico , Adulto , DNA Viral/análise , DNA Viral/genética , Feminino , Humanos , Papillomaviridae/genética , Infecções por Papillomavirus/virologia , Gravidez , Sensibilidade e Especificidade , Neoplasias do Colo do Útero/virologia , Displasia do Colo do Útero/virologia
7.
J Clin Microbiol ; 51(8): 2702-6, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23678069

RESUMO

We evaluated the effect of storage at 2 to 8°C on the stability of human genomic and human papillomavirus (HPV) DNA stored in BD SurePath and Hologic PreservCyt liquid-based cytology media. DNA retained the ability to be extracted and PCR amplified for more than 2.5 years in both medium types. Prior inability to detect DNA in archived specimens may have been due to failure of the extraction method to isolate DNA from fixed cells.


Assuntos
Técnicas Citológicas/métodos , DNA Viral/isolamento & purificação , Papillomaviridae/isolamento & purificação , Manejo de Espécimes/métodos , Virologia/métodos , Meios de Cultura/química , DNA Viral/genética , Humanos , Papillomaviridae/genética , Refrigeração , Fatores de Tempo
8.
J Clin Microbiol ; 49(8): 3029-32, 2011 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-21632892

RESUMO

Using archived specimens, we evaluated a new automated real-time PCR assay (BD Diagnostics) that detects all carcinogenic human papillomaviruses (HPV) and provides HPV genotyping for seven of them, including HPV16 and HPV18, the two most carcinogenic HPV genotypes. We found comparable results with Hybrid Capture 2 (HC2) for detection of carcinogenic HPV (n = 473) and with Linear Array and Line Blot Assay (n = 371) for detection of individual HPV genotypes.


Assuntos
Técnicas de Diagnóstico Molecular/métodos , Papillomaviridae/classificação , Papillomaviridae/isolamento & purificação , Infecções por Papillomavirus/virologia , Reação em Cadeia da Polimerase em Tempo Real/métodos , Virologia/métodos , Adulto , DNA Viral/genética , Feminino , Genótipo , Humanos , Papillomaviridae/genética , Papillomaviridae/patogenicidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA