Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 113
Filtrar
1.
Int J Mol Sci ; 25(2)2024 Jan 17.
Artigo em Inglês | MEDLINE | ID: mdl-38256197

RESUMO

The accumulation of protein aggregates defines distinct, yet overlapping pathologies such as Alzheimer's disease (AD), dementia with Lewy bodies (DLB), and frontotemporal dementia (FTD). In this study, we investigated ATG5, UBQLN2, ULK1, and LC3 concentrations in 66 brain specimens and 120 plasma samples from AD, DLB, FTD, and control subjects (CTRL). Protein concentration was measured with ELISA kits in temporal, frontal, and occipital cortex specimens of 32 AD, 10 DLB, 10 FTD, and 14 CTRL, and in plasma samples of 30 AD, 30 DLB, 30 FTD, and 30 CTRL. We found alterations in ATG5, UBQLN2, ULK1, and LC3 levels in patients; ATG5 and UBQLN2 levels were decreased in both brain specimens and plasma samples of patients compared to those of the CTRL, while LC3 levels were increased in the frontal cortex of DLB and FTD patients. In this study, we demonstrate alterations in different steps related to ATG5, UBQLN2, and LC3 autophagy pathways in DLB and FTD patients. Molecular alterations in the autophagic processes could play a role in a shared pathway involved in the pathogenesis of neurodegeneration, supporting the hypothesis of a common molecular mechanism underlying major neurodegenerative dementias and suggesting different potential therapeutic targets in the autophagy pathway for these disorders.


Assuntos
Doença de Alzheimer , Demência Frontotemporal , Doença por Corpos de Lewy , Doença de Pick , Humanos , Autofagia , Proteínas Relacionadas à Autofagia , Proteínas Adaptadoras de Transdução de Sinal
2.
Microb Drug Resist ; 30(1): 50-54, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37851491

RESUMO

Candida auris is a concerning pathogen in health care due to its ability to spread in medical settings. In this study, we characterized the genome of three C. auris clinical isolates collected in the Emilia-Romagna region of Northeastern Italy from January 2020 to May 2021. Whole-genome sequencing was performed using Illumina iSeq 100 and Oxford Nanopore MinION systems. Genomes were assembled with Flye. Phylogenetic analysis was carried out with RaxML. The ERG11, TAC1b, and FKS1 genes were examined for known substitutions associated with resistance to azoles and caspofungin using Diamond. All three C. auris isolates belonged to clade I (South Asian lineage) and showed high minimum inhibitory concentrations for fluconazole. Two of the three isolates were closely related to the first Italian index case of C. auris occurred in the 2019 and carried similar mutations associated to azole resistance. The third isolate showed a greater phylogenetic distance from these strains and had a different genetic determinant not previously seen in Italy. Our data suggest that two C. auris clinical isolates may have been epidemiologically related to the first outbreak previously observed in Italy, while the remaining isolate may have originated from a different source. Further research is needed to understand C. auris transmission and resistance and to control its spread.


Assuntos
Antifúngicos , Candidíase , Humanos , Antifúngicos/farmacologia , Candidíase/tratamento farmacológico , Candidíase/epidemiologia , Candida , Candida auris , Filogenia , Farmacorresistência Fúngica/genética , Testes de Sensibilidade Microbiana , Antibacterianos/farmacologia , Azóis
3.
J Clin Med ; 12(5)2023 Feb 28.
Artigo em Inglês | MEDLINE | ID: mdl-36902700

RESUMO

Candida auris is an emerging fungus that represents a serious health threat globally. In Italy, the first case was detected in July 2019. Then, one case was reported to the Ministry of Health (MoH) on January 2020. Nine months later, a huge number of cases were reported in northern Italy. Overall, 361 cases were detected in 17 healthcare facilities between July 2019 and December 2022 in the Liguria, Piedmont, Emilia-Romagna, and Veneto regions, including 146 (40.4%) deaths. The majority of cases (91.8%) were considered as colonised. Only one had a history of travel abroad. Microbiological data on seven isolates showed that all but one strain (85.7%) were resistant to fluconazole. All the environmental samples tested negative. Weekly screening of contacts was performed by the healthcare facilities. Infection prevention and control (IPC) measures were applied locally. The MoH nominated a National Reference Laboratory to characterise C. auris isolates and store the strains. In 2021, Italy posted two messages through the Epidemic Intelligence Information System (EPIS) to inform on the cases. On February 2022, a rapid risk assessment indicated a high risk for further spread within Italy, but a low risk of spread to other countries.

4.
Diagnostics (Basel) ; 13(4)2023 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-36832229

RESUMO

The analysis of synovial fluid is a crucial step in the diagnosis of prosthetic joint infections (PJIs). Recently several studies illustrated the efficacy of synovial calprotectin in supporting the diagnosis of PJI. In this study, synovial calprotectin was analyzed by a commercial stool test to explore whether it might accurately predict PJIs. The synovial fluids of 55 patients were analyzed and calprotectin levels were compared to other synovial biomarkers of PJI. Of the 55 synovial flu-ids, 12 patients were diagnosed with PJI and 43 with an aseptic failure of the implant. Specificity, sensitivity, and AUC of calprotectin resulted in 0.944, 0.80, and 0.852 (95%CI: 0.971-1.00), respectively, with a set threshold of 529.5 µg/g. Calprotectin had a statistically relevant correlation with the synovial leucocyte counts (rs = 0.69, p < 0.001) and the percentage of synovial neutrophils (rs = 0.61, p < 0.001). From this analysis, it can be concluded that synovial calprotectin is a valuable biomarker that correlates with other established indicators of local infection, and the use of a commercial lateral flow stool test could be a cost-effective strategy delivering rapid and reliable results and supporting the diagnostic process of PJI.

5.
Front Cell Infect Microbiol ; 13: 1128822, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36824688

RESUMO

Introduction: As we approach the post-antibiotic era, the development of innovative antimicrobial strategies that carry out their activities through non-specific mechanisms could limit the onset and spread of drug resistance. In this context, the use of nanogranular coatings of multielement nanoparticles (NPs) conjugated to the surface of implantable biomaterials might represent a strategy to reduce the systemic drawbacks by locally confining the NPs effects against either prokaryotic or eukaryotic cells. Methods: In the present study, two new multielement nanogranular coatings combining Ag and Cu with either Ti or Mg were synthesized by a gas phase physical method and tested against pathogens isolated from periprosthetic joint infections to address their potential antimicrobial value and toxicity in an in vitro experimental setting. Results: Overall, Staphylococcus aureus, Staphylococcus epidermidis and Escherichia coli displayed a significantly decreased adhesion when cultured on Ti-Ag-Cu and Mg-Ag-Cu coatings compared to uncoated controls, regardless of their antibiotic resistance traits. A dissimilar behavior was observed when Pseudomonas aeruginosa was cultured for 30 and 120 minutes upon the surface of Ti-Ag-Cu and Mg-Ag-Cu-coated discs. Biofilm formation was mainly reduced by the active effect of Mg-Ag-Cu compared to Ti-Ag-Cu and, again, coatings had a milder effect on P. aeruginosa, probably due to its exceptional capability of attachment and matrix production. These data were further confirmed by the evaluation of bacterial colonization on nanoparticle-coated discs through confocal microscopy. Finally, to exclude any cytotoxic effects on eukaryotic cells, the biocompatibility of NPs-coated discs was studied. Results demonstrated a viability of 95.8% and 89.4% of cells cultured in the presence of Ti-Ag-Cu and Mg-Ag-Cu discs, respectively, when compared to negative controls. Conclusion: In conclusion, the present study demonstrated the promising anti-adhesive features of both Ti-Ag-Cu and Mg-Ag-Cu coatings, as well as their action in hampering the biofilm formation, highlighting the safe use of the tested multi-element families of nanoparticles as new strategies against bacterial attachment to the surface of biomedical implants.


Assuntos
Anti-Infecciosos , Infecções Estafilocócicas , Humanos , Materiais Revestidos Biocompatíveis/farmacologia , Antibacterianos/farmacologia , Anti-Infecciosos/farmacologia , Staphylococcus aureus , Complicações Pós-Operatórias
6.
Radiol Med ; 128(3): 340-346, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36786971

RESUMO

PURPOSE: To investigate whether artificial intelligence (AI) can differentiate septic from non-septic total hip arthroplasty (THA) failure based on preoperative MRI features. MATERIALS AND METHODS: We included 173 patients (98 females, age: 67 ± 12 years) subjected to first-time THA revision surgery after preoperative pelvis MRI. We divided the patients into a training/validation/internal testing cohort (n = 117) and a temporally independent external-testing cohort (n = 56). MRI features were used to train, validate and test a machine learning algorithm based on support vector machine (SVM) to predict THA infection on the training-internal validation cohort with a nested fivefold validation approach. Machine learning performance was evaluated on independent data from the external-testing cohort. RESULTS: MRI features were significantly more frequently observed in THA infection (P < 0.001), except bone destruction, periarticular soft-tissue mass, and fibrous membrane (P > 0.005). Considering all MRI features in the training/validation/internal-testing cohort, SVM classifier reached 92% sensitivity, 62% specificity, 79% PPV, 83% NPV, 82% accuracy, and 81% AUC in predicting THA infection, with bone edema, extracapsular edema, and synovitis having been the best predictors. After being tested on the external-testing cohort, the classifier showed 92% sensitivity, 79% specificity, 89% PPV, 83% NPV, 88% accuracy, and 89% AUC in predicting THA infection. SVM classifier showed 81% sensitivity, 76% specificity, 66% PPV, 88% NPV, 80% accuracy, and 74% AUC in predicting THA infection in the training/validation/internal-testing cohort based on the only presence of periprosthetic bone marrow edema on MRI, while it showed 68% sensitivity, 89% specificity, 93% PPV, 60% NPV, 75% accuracy, and 79% AUC in the external-testing cohort. CONCLUSION: AI using SVM classifier showed promising results in predicting THA infection based on MRI features. This model might support radiologists in identifying THA infection.


Assuntos
Artroplastia de Quadril , Feminino , Humanos , Pessoa de Meia-Idade , Idoso , Artroplastia de Quadril/efeitos adversos , Inteligência Artificial , Imageamento por Ressonância Magnética/métodos , Algoritmos , Edema , Estudos Retrospectivos
7.
J Orthop Res ; 41(8): 1840-1847, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-36606419

RESUMO

This retrospective study was undertaken to (i) define the most appropriate thresholds for serum d-dimer and fibrinogen for differentiating aseptic failure from periprosthetic joint infection (PJI) and (ii) evaluate the predictive value of our d-dimer and fibrinogen threshold compared to previously proposed thresholds. This observational cohort study included consecutive patients who had undergone total knee arthroplasty (TKA) revision between January 2019 and December 2020. International Consensus Meeting diagnostic criteria were used to identify patients affected by the prosthetic infection. Receiver operating characteristic curve analyses assessed the predictive value of the parameters, and the areas under the curves were evaluated. We included 125 patients with a median age of 69 years (53-82) affected by painful TKA. Fifty-seven patients (47%) had PJI. Patients with PJI had higher median d-dimer, fibrinogen, ESR, and CRP when compared to patients believed to be free of PJI. The best threshold values for d-dimer and fibrinogen were 1063 ng/ml (sensitivity 0.72, specificity 0.74) and 420 mg/dl (sensitivity 0.67 and specificity 0.82), respectively. A d-dimer level >1063 ng/ml combined with a fibrinogen level >420 mg/dl had a sensitivity of 0.52, and a specificity of 0.90. We found that an increased d-dimer beyond 1063 ng/ml showed a better predictive value than the previously proposed threshold. The combined determination of d-dimer and fibrinogen displayed high specificity and should be considered an excellent tool to rule out an infection. The accuracy of the proposed cutoffs is more effective than previously reported.


Assuntos
Artrite Infecciosa , Artroplastia de Quadril , Infecções Relacionadas à Prótese , Humanos , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Fibrinogênio/análise , Proteína C-Reativa , Biomarcadores , Estudos Retrospectivos , Artroplastia de Quadril/efeitos adversos , Sedimentação Sanguínea , Infecções Relacionadas à Prótese/diagnóstico , Artrite Infecciosa/diagnóstico , Sensibilidade e Especificidade
8.
Mol Psychiatry ; 27(12): 5227-5234, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36028569

RESUMO

Alzheimer's disease (AD) is an irreversible neurodegenerative disorder that affects millions of people worldwide. AD pathogenesis is intricate. It primarily involves two main molecular players-amyloid-ß (Aß) and tau-which actually have an intrinsic trend to generate molecular assemblies that are toxic to neurons. Incomplete knowledge of the molecular mechanisms inducing the onset and sustaining the progression of the disease, as well as the lack of valid models to fully recapitulate the pathogenesis of human disease, have until now hampered the development of a successful therapy for AD. The overall experience with clinical trials with a number of potential drugs-including the recent outcomes of studies with monoclonal antibodies against Aß-seems to indicate that Aß-targeting is not effective if it is not accompanied by an efficient challenge of Aß neurotoxic properties. We took advantage from the discovery of a naturally-occurring variant of Aß (AßA2V) that has anti-amyloidogenic properties, and designed a novel bio-inspired strategy for AD based on the intranasal delivery of a six-mer peptide (Aß1-6A2V) retaining the anti-amyloidogenic abilities of the full-length AßA2V variant. This approach turned out to be effective in preventing the aggregation of wild type Aß and averting the synaptic damage associated with amyloidogenesis in a mouse model of AD. The results of our preclinical studies inspired by a protective model already existing in nature, that is the human heterozygous AßA2V carriers which seem to be protected from AD, open the way to an unprecedented and promising approach for the prevention of the disease in humans.


Assuntos
Doença de Alzheimer , Amiloide , Animais , Camundongos , Doença de Alzheimer/patologia , Doença de Alzheimer/terapia , Amiloide/antagonistas & inibidores , Peptídeos beta-Amiloides/uso terapêutico , Modelos Animais de Doenças
9.
Front Surg ; 9: 850342, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35372461

RESUMO

Hemoglobin and its associated blood values are important laboratory biomarkers that mirror the strength of constitution of patients undergoing spine surgery. Along with the clinical determinants available during the preadmission visit, it is important to explore their potential for predicting clinical success from the patient's perspective in order to make the pre-admission visit more patient-centered. We analyzed data from 1,392 patients with spine deformity, disc disease, or spondylolisthesis enrolled between 2016 and 2019 in our institutional Spine Registry. Patient-reported outcome measure at 17 months after surgery was referred to the Oswestry disability index. High preoperative hemoglobin was found to be the strongest biochemical determinant of clinical success along with high red blood cells count, while low baseline disability, prolonged hospitalization, and long surgical times were associated with poor recovery. The neural network model of these predictors showed a fair diagnostic performance, having an area under the curve of 0.726 and a sensitivity of 86.79%. However, the specificity of the model was 15.15%, thus providing to be unreliable in forecasting poor patient-reported outcomes. In conclusion, preoperative hemoglobin may be one of the key biomarkers on which to build appropriate predictive models of long-term recovery after spine surgery, but it is necessary to include multidimensional variables in the models to increase the reliability at the patient's level.

10.
Microorganisms ; 10(3)2022 Feb 28.
Artigo em Inglês | MEDLINE | ID: mdl-35336102

RESUMO

Understanding how bacteria adapt their social behavior to environmental changes is of crucial importance from both biological and clinical perspectives. Staphylococcus aureus is among the most common infecting agents in orthopedics, but its recalcitrance to the immune system and to antimicrobial treatments in the physiological microenvironment are still poorly understood. By means of optical and confocal microscopy, image pattern analysis, and mathematical modeling, we show that planktonic biofilm-like aggregates and sessile biofilm lifestyles are two co-existing and interacting phases of the same environmentally adaptive developmental process and that they exhibit substantial differences when S. aureus is grown in physiological fluids instead of common lab media. Physicochemical properties of the physiological microenvironment are proposed to be the key determinants of these differences. Besides providing a new tool for biofilm phenotypic analysis, our results suggest new insights into the social behavior of S. aureus in physiological conditions and highlight the inadequacy of commonly used lab media for both biological and clinical studies of bacterial development.

11.
J Clin Lab Anal ; 36(5): e24363, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-35334493

RESUMO

BACKGROUND: Serological tests can be used to detect antibodies in the serum of subject's after SARS-CoV-2 infection and vaccination. Currently, variability in antibody titers and the availability of a multiplicity of serological tests have made it necessary to highlight their appropriateness and limitations in various diagnostic settings. METHODS: This study is part of Covidiagnostix, a multicenter project aimed at the assessment of the health technology used in SARS-CoV-2 serological tests. Based on data gained from the analysis of over 5000 subjects, a selected number of serum samples, representative of different diagnostic settings, were analyzed first by qualitative immunoassays (IgA, M, and G MILLIPLEX® SARS-CoV-2 tests based on Luminex® ) to define the immunoglobulins serum composition and subsequently by four serological diagnostic tests (Elecsys Anti-SARS-CoV-2 and Elecsys Anti-SARS-CoV-2 S by Roche, SARS-CoV-2 IgG by Siemens Healthcare, and CHORUS SARS-CoV-2 "NEUTRALIZING" Ab by DIESSE). The first WHO International Standard for SARS-CoV-2 was also analyzed using the same methods. RESULTS: This study evaluated the antibody content and titer of the WHO Standard and serum of subjects with/without previous infection and before/after vaccination for SARS-CoV-2. CONCLUSION: The definition of antibodies in the WHO standard and the analysis of serum samples allowed for the identification of the appropriateness of serological tests in each diagnostic setting, increasing the effectiveness of the resulting laboratory data. Furthermore, we found that it would be optimal to produce new international standards against the S1 domain and RBD of the SARS-CoV-2 spike protein for a more effective serological monitoring of vaccination.


Assuntos
COVID-19 , SARS-CoV-2 , Anticorpos Antivirais , COVID-19/diagnóstico , Humanos , Testes Sorológicos , Glicoproteína da Espícula de Coronavírus
12.
BMC Surg ; 22(1): 68, 2022 Feb 25.
Artigo em Inglês | MEDLINE | ID: mdl-35216567

RESUMO

BACKGROUND: Periprosthetic hip infections with severe proximal femoral bone loss may require the use of limb salvage techniques, but no agreement exists in literature regarding the most effective treatment. Aim of this study is to analyze the infection eradication rate and implant survival at medium-term follow-up in patients treated with megaprostheses for periprosthetic hip infections with severe bone loss. METHODS: Twenty-one consecutive patients were retrospectively reviewed at a mean 64-month follow-up (24-120). Functional and pain scores, microbiological, radiological and intraoperative findings were registered. Kaplan Meier survival analysis and log rank test were used for infection free survival and implant survival analyses. RESULTS: The infection eradication rate was 90.5%, with an infection free survival of 95.2% at 2 years (95%CI 70.7-99.3) and 89.6%(95%CI 64.3-97.3) at 5 years. Only two patients required major implant revisions for aseptic implant loosening. The most frequent complication was dislocation (38.1%). The major revision-free survival of implants was 95.2% (95%CI 70.7-99.3) at 2 years and 89.6% (95%CI 64.3-97.3) at 5 years. The overall implant survival was 83.35% (CI95% 50.7-93.94) at 2 and 5 years. Subgroup analyses (cemented versus cementless MPs, coated versus uncoated MPs) revealed no significant differences at log rank test, but its reliability was limited by the small number of patients included. CONCLUSIONS: Proximal femoral arthroplasty is useful to treat periprosthetic hip infections with severe bone loss, providing good functional results with high infection eradication rates and rare major revisions at medium-term follow-up. No conclusions can be drawn on the role of cement and coatings.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Artroplastia de Quadril/efeitos adversos , Artroplastia de Quadril/métodos , Seguimentos , Prótese de Quadril/efeitos adversos , Humanos , Desenho de Prótese , Falha de Prótese , Reoperação/efeitos adversos , Reprodutibilidade dos Testes , Estudos Retrospectivos , Resultado do Tratamento
13.
J Arthroplasty ; 37(3): 565-573, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-34822929

RESUMO

BACKGROUND: We evaluated the reliability of intraoperative assessment of leukocyte esterase (LE) in synovial fluid samples from patients undergoing reimplantation following implant removal and spacer insertion for periprosthetic joint infection (PJI). Our hypothesis was that a positive intraoperative LE test would be a better predictor of persistent infection than either serum C-reactive protein (CRP) or erythrocyte sedimentation rate (ESR) or the combination of serum CRP and ESR. METHODS: The records of 76 patients who received a 2-stage exchange for PJI were retrospectively reviewed. Synovial fluid was collected for LE measurement during surgery before arthrotomy in 79 procedures. Receiver operating characteristic curves were generated. Sensitivity, specificity, positive predictive value, negative predictive value, accuracy, and area under the curve (AUC) of LE, CRP, ESR, and CRP + ESR were calculated. RESULTS: Sensitivity, specificity, positive predictive value, and negative predictive value of the LE assay were 82%, 99%, 90%, and 97%, respectively. Receiver operating characteristic analysis revealed an LE threshold of 1.5 between the first (negative) and the second (positive) level of the ordinal variable, so that a grade starting from 1+ was accurate for a diagnosis of persistent infection (AUC 0.9044). The best thresholds for the CRP and the ESR assay were 8.25 mg/L (82% sensitivity, 84% specificity, AUC 0.8416) and 45 mm/h (55% sensitivity, 87% specificity, AUC 0.7493), respectively. CONCLUSION: The LE strip test proved a reliable tool to diagnose persistence of infection and outperformed the serum CRP and ESR assays. The strip test provides a valuable intraoperative diagnostic during second-stage revision for PJI.


Assuntos
Artroplastia de Quadril , Infecções Relacionadas à Prótese , Biomarcadores , Sedimentação Sanguínea , Proteína C-Reativa/análise , Hidrolases de Éster Carboxílico , Humanos , Infecções Relacionadas à Prótese/diagnóstico , Infecções Relacionadas à Prótese/cirurgia , Reimplante , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade , Líquido Sinovial/química
14.
Clin Chem Lab Med ; 59(12): 2019-2026, 2021 Nov 25.
Artigo em Inglês | MEDLINE | ID: mdl-34614550

RESUMO

OBJECTIVES: After exceptional research efforts, several vaccines were developed against SARS-CoV-2 which sustains the pandemic COVID-19. The Comirnaty vaccine showed high efficacy in clinical trials and was the first to be approved for its distribution to the general population. We evaluated the immune response induced by the first vaccine dose in different sex/age groups and subjects with or without naturally present anti-SARS-CoV-2 antibodies. METHODS: As part of an Italian multicenter project (Covidiagnostix), serum samples from 4,290 health-professionals were serologically tested the day of the first vaccination dose, and 21 days later, using two different instrumentations (Siemens-Healthineers and Roche). RESULTS: In total, 97% of samples showed the presence of specific antibodies 21 days after the vaccination dose; the percentage of non-responders increased with age in both genders. Remarkably, naturally seropositive individuals showed antibody persistence up to 11 months and an exceptionally higher vaccination response compared to subjects never infected by SARS-CoV-2. CONCLUSIONS: This study highlighted the importance of the serological test i) to identify naturally SARS-CoV-2 seropositive individuals and ii) to evaluate the antibody level elicited by the first vaccination dose. Both tests, highlighted differences in the immune response, when subjects were stratified by sex and age, and between naturally seropositive and seronegative subjects. The data obtained show how serological tests could play a crucial role in the triage of the population subjected to the vaccination campaign for COVID-19. The definition of suitable instrumentation-specific thresholds is needed to correctly follow eventually acquired post-vaccination immunity in the general population.


Assuntos
Anticorpos Antivirais/sangue , Vacinas contra COVID-19/administração & dosagem , COVID-19/prevenção & controle , Programas de Imunização , Adulto , Idoso , Idoso de 80 Anos ou mais , COVID-19/imunologia , COVID-19/virologia , Vacinas contra COVID-19/imunologia , Feminino , Pessoal de Saúde , Humanos , Imunidade Humoral , Imunoensaio , Masculino , Pessoa de Meia-Idade , SARS-CoV-2/isolamento & purificação , Adulto Jovem
15.
Antimicrob Resist Infect Control ; 10(1): 123, 2021 08 19.
Artigo em Inglês | MEDLINE | ID: mdl-34412693

RESUMO

BACKGROUND: Carbapenem-resistant Acinetobacter baumannii (CRAB) infection outbreaks are difficult to control and sometimes require cohorting of CRAB-positive patients or temporary ward closure for environmental cleaning. We aimed at controlling the deadly 2018 CRAB outbreak in a 12 bed- intensive care unit (ICU) including 9 beds in a 220 m2 open space. We implemented a new multimodal approach without ward closure, cohorting or temporarily limiting admissions. METHODS: A five-component bundle was introduced in 2018 including reinforcement of hand hygiene and sample extension of screening, application of contact precautions to all patients, enhanced environmental sampling and the one-time application of a cycling radical environmental cleaning and disinfection procedure of the entire ICU. The ICU-CRAB incidence density (ID), ICU alcohol-based hand rub consumption and antibiotic use were calculated over a period of 6 years and intervention time series analysis was performed. Whole genome sequencing analysis (WGS) was done on clinical and environmental isolates in the study period. RESULTS: From January 2013, nosocomial ICU-CRAB ID decreased from 30.4 CRAB cases per 1000 patients-days to zero cases per 1000 patients-days. Our intervention showed a significant impact (-2.9 nosocomial ICU-CRAB cases per 1000 bed-days), while no influence was observed for antibiotic and alcohol-based hand rub (AHR) consumption. WGS demonstrated that CRAB strains were clonally related to an environmental reservoir which confirms the primary role of the environment in CRAB ICU spreading. CONCLUSION: A five-component bundle of continuous hand hygiene improvement, extended sampling at screening including the environment, universal contact precautions and a novel cycling radical environmental cleaning and disinfection procedure proved to be effective for permanently eliminating CRAB spreading within the ICU. Cohorting, admission restriction or ICU closure were avoided.


Assuntos
Infecções por Acinetobacter/prevenção & controle , Carbapenêmicos/farmacologia , Infecção Hospitalar/prevenção & controle , Farmacorresistência Bacteriana , Controle de Infecções/métodos , Infecções por Acinetobacter/epidemiologia , Acinetobacter baumannii/efeitos dos fármacos , Gestão de Antimicrobianos , Infecção Hospitalar/epidemiologia , Infecção Hospitalar/microbiologia , Surtos de Doenças/prevenção & controle , Higiene das Mãos , Higienizadores de Mão , Hospitais Universitários , Humanos , Unidades de Terapia Intensiva , Itália , Centros de Atenção Terciária , Sequenciamento Completo do Genoma
16.
Clin Chim Acta ; 522: 144-151, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34425105

RESUMO

BACKGROUND AND AIMS: Vaccines, to limit SARS-CoV-2 infection, were produced and reliable assays are needed for their evaluation. The WHO produced an International-Standard (WHO-IS) to facilitate the standardization/comparison of serological methods. The WHO-IS, produced in limited amount, was never tested for reproducibility. This study aims at developing a reproducible and accessible working standard (WS) to complement the WHO-IS. MATERIALS AND METHODS: Sera from vaccinated individuals were used to produce the WSs. The WHO-IS, the WSs and single serum samples (n = 48) were tested on 6 quantitative serological devices. Neutralization assays were performed for the 48 samples and compared with their antibody titers. RESULTS: The WS carry an antibody titer 20-fold higher than the WHO-IS. It was reproducible, showed both good linearity and insignificant intra- and inter-laboratory variability. However, the WSs behave differently from the WHO-IS. Analysis of the 48 samples showed that single correlation factors are not sufficient to harmonize results from different assays. Yet, all the devices predict neutralization activity based on the antibody titer. CONCLUSIONS: A reproducible and highly concentrated WS, specific for IgG against SARS-CoV-2 Spike-glycoprotein was produced. Such characteristics make it particularly suited for the harmonization of commercially available assays and the consequent evaluation of post-vaccinated individuals.


Assuntos
COVID-19 , SARS-CoV-2 , Anticorpos Neutralizantes , Anticorpos Antivirais , Humanos , Testes de Neutralização , Reprodutibilidade dos Testes
17.
BMC Infect Dis ; 21(1): 416, 2021 May 04.
Artigo em Inglês | MEDLINE | ID: mdl-33947342

RESUMO

BACKGROUND: Prosthetic joint infection (PJI) is one of the most feared complications following total arthroplasty surgeries. Gram-positive bacteria are the most common microorganisms implicated in PJIs, while infections mediated by fungi only account for 1% of cases. When dealing with PJIs, a two-stage revision arthroplasty is widely used. Briefly, a spacer is introduced until re-implantation of the definitive prosthesis to provide skeleton stabilization while delivering antibiotics in the site of the infection. Sometimes, antimicrobial therapy may fail, but the isolation of a second microorganism from the spacer is uncommon and even less frequent that of a yeast. CASE PRESENTATION: Here is described a case of a 75-year-old woman who underwent two-stage revision surgery of the left hip prosthesis secondary to a Staphylococcus capitis infection, whose spacer was found to be infected by Candida albicans at a later time. Briefly, the patient underwent revision surgery of the hip prosthesis for a suspected PJI. After the debridement of the infected tissue, an antibiotic-loaded spacer was implanted. The microbiological analysis of the periprosthetic tissues and the implant depicted a S. capitis infection that was treated according to the antimicrobial susceptibility profile of the clinical isolate. Three months later, the patient was admitted to the emergency room due to local inflammatory signs. Synovial fluid was sent to the laboratory for culture. No evidence of S. capitis was detected, however, a yeast was identified as Candida albicans. Fifteen days later, the patient was hospitalized for the removal of the infected spacer. Microbiological cultures confirmed the results of the synovial fluid analysis. According to the susceptibility profile, the patient was treated with fluconazole (400 mg/day) for 6 months. Seven months later, the patient underwent second-stage surgery. The microbiological tests on the spacer were all negative. After 12 months of follow-up, the patient has fully recovered and no radiological signs of infection have been detected. CONCLUSIONS: Given the exceptionality of this complication, it is important to report these events to better understand the clinical outcomes after the selected therapeutic options to prevent and forestall the development of either bacterial or fungal spacer infections.


Assuntos
Candidíase/cirurgia , Prótese de Quadril/efeitos adversos , Infecções Relacionadas à Prótese/microbiologia , Infecções Relacionadas à Prótese/cirurgia , Infecções Estafilocócicas/cirurgia , Idoso , Antibacterianos/uso terapêutico , Artroplastia de Quadril , Candida albicans/isolamento & purificação , Candidíase/microbiologia , Feminino , Humanos , Reoperação , Infecções Estafilocócicas/microbiologia , Staphylococcus capitis/patogenicidade
18.
Eur J Clin Microbiol Infect Dis ; 40(9): 1891-1898, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-33839972

RESUMO

In response to the rapidly evolving of SARS-CoV-2 infection, numerous serological tests have been developed but their sensitivity and specificity are unclear. We collected serum samples of patients and health-care professionals to assess the accuracy of chemiluminescent (CLIA) and two lateral flow immunochromatographic assays (LFIA) to determine IgG and IgM antibodies to SARS-CoV-2 virus. We calculated the φ correlation for qualitative results and test accuracy, adopting the following case definition: either real-time-PCR positivity or serological positivity with at least two different tests. We analyzed 259 samples, obtaining strong correlation between CLIA and both LFIA for IgG (φ=0.9), and moderate correlation for IgM (φ=0.6). For patients, the sensitivity was suboptimal for all methods (CLIA 81%, LFIA A 85%, LFIA B 78%), while it was poor in asymptomatic health-care workers (CLIA 50%, LFIA A 50%, LFIA B 33%). Overall, CLIA is more sensitive and specific for the determination of both IgG and IgM, whilst both LFIA methods reported good sensitivity and specificity for IgG, but scarce sensitivity for the IgM determination. The determination of SARS-CoV-2-specific IgG is useful to detect infection 6 days from symptom onset.


Assuntos
Anticorpos Antivirais/sangue , Teste Sorológico para COVID-19/métodos , Teste Sorológico para COVID-19/normas , COVID-19/sangue , Imunoglobulina G/sangue , Imunoglobulina M/sangue , SARS-CoV-2/imunologia , Adulto , Idoso , Idoso de 80 Anos ou mais , COVID-19/virologia , Estudos Transversais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Sensibilidade e Especificidade , Adulto Jovem
19.
Front Med (Lausanne) ; 8: 582896, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33842494

RESUMO

Italy was one of the worst affected European countries during the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) pandemic. More than 50% of Italian cases occurred in the northern region of Lombardy, where the saturation of health services between March and April 2020 forced hospitals to allocate patients according to available resources. Eighteen severe coronavirus disease 2019 (COVID-19) patients were admitted to our hospital needing intensive support. Given the disease fatality, we investigated the patients' characteristics to identify mortality predictors. We counted seven deaths from multiple organ failure, two from septic shock, and two from collapsed lungs. The maximum case fatality was observed in patients who contracted SARS-CoV-2 in hospitals. The fatal outcome was associated with the following baseline characteristics: polymorbidity (OR 2.519, p = 0.048), low body mass index (OR 2.288, p = 0.031), low hemoglobin (OR 3.012, p = 0.046), and antithrombin III (OR 1.172, p = 0.048), along with a worsening of PaO2/FiO2 ratio in the first 72 h after admission (OR 1.067, p = 0.031). The occurrence of co-infections during hospitalization was associated with a longer need for intensive care (B = 4.511, p = 0.001). More information is needed to inform intensive care for patients with severe COVID-19, but our findings would certainly contribute to shed some light on this unpredictable and multifaceted disease.

20.
J Arthroplasty ; 36(8): 2962-2967, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-33814266

RESUMO

BACKGROUND: To diagnose periprosthetic joint infection (PJI) preoperatively, ultrasound-guided joint aspiration (US-JA) may not be performed when effusion is minimal or absent. We aimed to report and investigate the diagnostic performance of ultrasound-guided periprosthetic biopsy (US-PB) of synovial tissue to obtain joint samples in patients without fluid around the implants. METHODS: One-hundred nine patients (55 men; mean age: 68 ± 13 years) with failed total hip arthroplasty (THA) who underwent revision surgery performed preoperative US-JA or US-PB to rule out PJI. RESULTS: Sixty-nine of 109 patients had joint effusion and underwent US-JA, while the remaining 40 with dry joint required US-PB. Thirty-five of 109 patients (32.1%) had PJI, while 74/109 (67.9%) had aseptic THA failure. No immediate complications were observed in both groups. Technical success of US-PB was 100%, as the procedure was carried on as planned in all cases. Sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of US-JA were 52.2%, 97.8%, 92.3%, 80.3%, and 82.6%, while for US-PB, they were 41.7%, 100%, 100%, 80%, and 82.5%, respectively, with no significant difference (P = .779). Using the final diagnosis as reference standard, we observed a moderate agreement with both US-JA (k = 0.56) and US-PB (k = 0.50). CONCLUSION: We present a novel US-guided technique to biopsy periprosthetic synovial tissue of failed THA to rule out PJI. We found similar diagnostic performance as compared with traditional US-JA. This supports future larger studies on this procedure that might be applied in patients without joint effusion.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Infecções Relacionadas à Prótese , Idoso , Idoso de 80 Anos ou mais , Artroplastia de Quadril/efeitos adversos , Biomarcadores , Biópsia , Prótese de Quadril/efeitos adversos , Humanos , Masculino , Pessoa de Meia-Idade , Infecções Relacionadas à Prótese/diagnóstico , Infecções Relacionadas à Prótese/etiologia , Infecções Relacionadas à Prótese/cirurgia , Reoperação , Sensibilidade e Especificidade , Líquido Sinovial , Ultrassonografia de Intervenção
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA