Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Basic Res Cardiol ; 112(6): 61, 2017 09 13.
Artigo em Inglês | MEDLINE | ID: mdl-28905113

RESUMO

Baseline assessment of functional stenosis severity has been proposed as a practical alternative to hyperemic indices. However, intact autoregulation mechanisms may affect intracoronary hemodynamics. The aim of this study was to investigate the effect of changes in aortic pressure (Pa) and heart rate (HR) on baseline coronary hemodynamics and functional stenosis assessment. In 15 patients (55 ± 3% diameter stenosis) Pa, intracoronary pressure (Pd) and flow velocity were obtained at control, and during atrial pacing at 120 bpm, increased Pa (+30 mmHg) with intravenous phenylephrine (PE), and elevated Pa while pacing at sinus heart rate (PE + sHR). We derived rate pressure product (RPP = systolic Pa × HR), baseline microvascular resistance (BMR = Pd/velocity), and stenosis resistance [BSR = (Pa - Pd)/velocity] as well as whole-cycle Pd/Pa. Tachycardia (120 ± 1 bpm) raised RPP by 74% vs. CONTROL: Accordingly, BMR decreased by 27% (p < 0.01) and velocity increased by 36% (p < 0.05), while Pd/Pa decreased by 0.05 ± 0.02 (p < 0.05) and BSR remained similar to control. Raising Pa to 121 ± 3 mmHg (PE) with concomitant reflex bradycardia increased BMR by 26% (p < 0.001) at essentially unchanged RPP and velocity. Consequently, BSR and Pd/Pa were only marginally affected. During PE + sHR, velocity increased by 21% (p < 0.01) attributable to a 46% higher RPP (p < 0.001). However, BMR, BSR, and Pd/Pa remained statistically unaffected. Nonetheless, the interventions tended to increase functional stenosis severity, causing Pd/Pa and BSR of borderline lesions to cross the diagnostic threshold. In conclusion, coronary microvascular adaptation to physiological conditions affecting metabolic demand at rest influences intracoronary hemodynamics, which may lead to altered basal stenosis indices used for clinical decision-making.


Assuntos
Adaptação Fisiológica/fisiologia , Pressão Arterial/fisiologia , Estenose Coronária/diagnóstico , Estenose Coronária/fisiopatologia , Frequência Cardíaca/fisiologia , Circulação Coronária/fisiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
2.
Am J Physiol Heart Circ Physiol ; 303(4): H422-8, 2012 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-22730389

RESUMO

Depending on stenosis severity, collateral flow can be a confounding factor in the determination of coronary hyperemic microvascular resistance (HMR). Under certain assumptions, the calculation of HMR can be corrected for collateral flow by incorporating the wedge pressure (P(w)) in the calculation. However, although P(w) > 25 mmHg is indicative of collateral flow, P(w) does in part also reflect myocardial wall stress neglected in the assumptions. Therefore, the aim of this study was to establish whether adjusting HMR by P(w) is pertinent for a diagnostically relevant range of stenosis severities as expressed by fractional flow reserve (FFR). Accordingly, intracoronary pressure and Doppler flow velocity were measured a total of 95 times in 29 patients distal to a coronary stenosis before and after stepwise percutaneous coronary intervention. HMR was calculated without (HMR) and with P(w)-based adjustment for collateral flow (HMR(C)). FFR ranged from 0.3 to 1. HMR varied between 1 and 5 and HMR(C) between 0.5 and 4.2 mmHg·cm(-1)·s. HMR was about 37% higher than HMR(C) for stenoses with FFR < 0.6, but for FFR > 0.8, the relative difference was reduced to 4.4 ± 3.4%. In the diagnostically relevant range of FFR between 0.6 and 0.8, this difference was 16.5 ± 10.4%. In conclusion, P(w)-based adjustment likely overestimates the effect of potential collateral flow and is not needed for the assessment of coronary HMR in the presence of a flow-limiting stenosis characterized by FFR between 0.6 and 0.8 or for nonsignificant lesions.


Assuntos
Circulação Colateral , Circulação Coronária , Estenose Coronária/diagnóstico , Estenose Coronária/fisiopatologia , Microcirculação , Idoso , Angioplastia Coronária com Balão , Cateterismo Cardíaco , Estenose Coronária/terapia , Ecocardiografia Doppler , Eletrocardiografia , Feminino , Reserva Fracionada de Fluxo Miocárdico , Humanos , Hiperemia/fisiopatologia , Masculino , Pessoa de Meia-Idade , Modelos Cardiovasculares , Valor Preditivo dos Testes , Pressão Propulsora Pulmonar , Índice de Gravidade de Doença , Resultado do Tratamento
3.
Med Biol Eng Comput ; 47(2): 233-9, 2009 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-19205771

RESUMO

Wave intensity analysis (WIA) is beginning to be applied to the coronary circulation both to better understand coronary physiology and as a diagnostic tool. Separation of wave intensity (WI) into forward and backward traveling components requires knowledge of pulse wave velocity at the point of measurement, which at present cannot accurately be determined in human coronary vessels. This prompted us to study the sensitivity of wave separation to variations in wave speed. An estimate of wave speed (SPc) was calculated based on measured distal intracoronary pressure and Doppler velocity in normal and diseased coronary vessels of patients during hyperemia. Changes of the area under separated WI waveforms were determined for a range of wave speeds from 25 to 200% of the calculated value. Variations in wave speed between half to twice the calculated value did not substantially alter separated WI. In conclusion, although SPc lacks accuracy in determining local coronary wave speed it is within limits still applicable for wave separation in coronary WIA.


Assuntos
Vasos Coronários/fisiologia , Modelos Cardiovasculares , Velocidade do Fluxo Sanguíneo/fisiologia , Pressão Sanguínea/fisiologia , Circulação Coronária , Estenose Coronária/fisiopatologia , Humanos , Fluxo Pulsátil/fisiologia , Processamento de Sinais Assistido por Computador
4.
Am J Physiol Heart Circ Physiol ; 295(5): H2054-60, 2008 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-18790830

RESUMO

The effect of alpha1-receptor blockade with urapidil on coronary blood flow and left ventricular function has been attributed to relief of diffuse coronary vasoconstriction following percutaneous coronary intervention (PCI). We hypothesized that an increase in diastolic time fraction (DTF) contributes to the beneficial action of urapidil. In eleven patients with a 63% (SD 13) diameter stenosis, ECG, aortic pressure (Pa) and distal intracoronary pressure (Pd), and blood flow velocity were recorded at baseline and throughout adenosine-induced hyperemia. Measurements were obtained before and after PCI and after subsequent alpha1-receptor blockade with urapidil (10 mg ic). DTF was determined from the ECG and the Pa waveform. Functional parameters such as coronary flow velocity reserve, fractional flow reserve, and an index of hyperemic microvascular resistance (HMR) were assessed. Urapidil administration after PCI induced an upward shift in the DTF-heart rate relationship, resulting in a 3.1% (SD 2.7) increase in hyperemic DTF at a constant heart rate (P < 0.005) due to a shorter duration of systole. Hyperemic Pa and Pd decreased, respectively, by 6.1% (SD 6.6; P < 0.05) and 5.7% (SD 5.8; P < 0.01) after alpha1-blockade. Although epicardially measured functional parameters were on average not altered by alpha1-blockade due to concurrent changes in pressure and heart rate, HMR decreased by urapidil in those patients where coronary pressure remained constant. In conclusion, alpha1-receptor blockade after PCI produced a modest but significant prolongation of DTF at a given heart rate, thereby providing an adjunctive beneficial mechanism for improving subendocardial perfusion, which critically depends on DTF.


Assuntos
Antagonistas de Receptores Adrenérgicos alfa 1 , Antagonistas Adrenérgicos alfa/uso terapêutico , Angioplastia Coronária com Balão , Circulação Coronária/efeitos dos fármacos , Estenose Coronária/terapia , Hemodinâmica/efeitos dos fármacos , Piperazinas/uso terapêutico , Idoso , Pressão Sanguínea/efeitos dos fármacos , Terapia Combinada , Estenose Coronária/metabolismo , Estenose Coronária/fisiopatologia , Diástole/efeitos dos fármacos , Feminino , Frequência Cardíaca/efeitos dos fármacos , Humanos , Masculino , Pessoa de Meia-Idade , Receptores Adrenérgicos alfa 1/metabolismo , Fatores de Tempo , Resultado do Tratamento , Resistência Vascular/efeitos dos fármacos , Vasodilatação/efeitos dos fármacos
5.
Am J Physiol Heart Circ Physiol ; 292(5): H2349-55, 2007 May.
Artigo em Inglês | MEDLINE | ID: mdl-17220185

RESUMO

The aim of this study was to assess the influence of a second guidewire on the diagnostic accuracy of functional parameters of coronary lesion severity. Sixty-five patients with intermediate coronary lesions underwent myocardial perfusion scintigraphy. Fractional flow reserve (FFR), coronary flow velocity reserve (CFVR), and hyperemic stenosis resistance (HSR) index (HSR = stenosis pressure gradient / velocity) were determined in 77 lesions. Distal pressure and velocity were acquired simultaneously (dual wire) and sequentially (single wire) with two sensor-equipped guidewires. Overall, functional parameters deteriorated from single- to dual-wire assessment. In patients without ischemia, the good diagnostic performance of FFR, CFVR, and HSR deteriorated significantly (P < 0.001) when assessed by dual wires, with an increase in the number of false-positive results. This trend was more pronounced for HSR, since the presence of a second wire reduced maximal velocity and increased the pressure gradient. The presence of two guidewires, especially across a myocardial perfusion scintigraphy-induced nonsignificant lesion, is associated with overestimation of the hemodynamically assessed lesion severity and, therefore, is likely to have a major impact on clinical decision making. This underscores the advantage of a dual-sensor-equipped guidewire for the evaluation of stenosis severity by combined pressure and velocity measurements.


Assuntos
Cateterismo Cardíaco/métodos , Circulação Coronária , Estenose Coronária/diagnóstico , Estenose Coronária/fisiopatologia , Índice de Gravidade de Doença , Idoso , Idoso de 80 Anos ou mais , Estenose Coronária/classificação , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Resistência Vascular
6.
Circulation ; 111(1): 76-82, 2005 Jan 04.
Artigo em Inglês | MEDLINE | ID: mdl-15611371

RESUMO

BACKGROUND: Coronary microvascular resistance during maximal hyperemia is generally assumed to be unaffected by percutaneous coronary interventions (PCIs). We assessed a velocity-based index of hyperemic microvascular resistance (h-MR(v)) by using prototypes of a novel, dual-sensor (Doppler velocity and pressure)-equipped guidewire before and after PCI to test this hypothesis. METHODS AND RESULTS: Aortic pressure, flow velocity (h-v), and pressure (h-P(d)) distal to 24 coronary lesions were measured simultaneously during maximal hyperemia induced by intracoronary adenosine. Measurements were obtained in the reference vessel before PCI and in the target vessel before and after PCI, stenting, and ultrasound-guided, upsized stenting. h-P(d) increased from 57.9+/-17.0 to 85.5+/-15.6 mm Hg, and h-MR(v) (ie, h-P(d)/h-v) decreased from 2.74+/-1.40 to 1.58+/-0.61 mm Hg x cm(-1) . s after stenting (both P<0.001). The reduction in h-MR(v) accounted for 34% of the decrease in total coronary resistance achieved by PCI. h-MR(v) of the target vessel after PCI was lower than that of the corresponding reference vessel despite a higher h-P(d) in the reference vessel (P<0.01). Post-PCI baseline MR(v) was correlated with baseline P(d) before PCI (P<0.01). CONCLUSIONS: PCI-induced restoration of P(d) resulted in a reduction of h-MR(v) in accordance with the pressure dependence of h-MR(v). The decrease in h-MR(v) to a level below that of the corresponding reference vessel in the immediate post-PCI period and a lowered baseline MR(v) suggest microvascular remodeling induced by long-term exposure to a low-pressure environment.


Assuntos
Angioplastia Coronária com Balão , Circulação Coronária , Vasos Coronários/fisiopatologia , Resistência Vascular , Adenosina , Idoso , Angina Pectoris/fisiopatologia , Angina Pectoris/terapia , Angioplastia Coronária com Balão/instrumentação , Pressão Sanguínea , Angiografia Coronária , Feminino , Hemodinâmica , Humanos , Hiperemia/fisiopatologia , Masculino , Microcirculação , Pessoa de Meia-Idade , Stents , Ultrassonografia de Intervenção , Vasodilatadores
7.
Circulation ; 109(6): 756-62, 2004 Feb 17.
Artigo em Inglês | MEDLINE | ID: mdl-14970112

RESUMO

BACKGROUND: Lack of high-fidelity simultaneous measurements of pressure and flow velocity distal to a coronary artery stenosis has hampered the study of stenosis pressure drop-velocity (DeltaP-v) relationships in patients. METHODS AND RESULTS: A novel 0.014-inch dual-sensor (pressure and Doppler velocity) guidewire was used in 15 coronary lesions to obtain per-beat averages of pressure drop and velocity after an intracoronary bolus of adenosine. DeltaP-v relations from resting to maximal hyperemic velocity were constructed before and after stepwise executed percutaneous coronary intervention (PCI). Before PCI, half of the DeltaP-v relations revealed the presence of a compliant stenosis, which was stabilized by angioplasty. Fractional flow reserve (FFR), coronary flow reserve (CFVR), and velocity-based indices of stenosis resistance (h-SRv) and microvascular resistance (h-MRv) at maximal hyperemia were compared. Stepwise PCI significantly lowered h-SRv, with an initial marked reduction in hyperemic pressure drop followed by further gains in velocity. A concomitant significant reduction of h-MRv accounted for half of the gain in velocity after PCI. The average magnitude of absolute incremental hemodynamic changes was highest for h-SRv (56.8+/-39.2%) compared with CFVR (35.3+/-34.5%, P<0.005) or FFR (19.5+/-25.2%, P<0.0001). CONCLUSIONS: DeltaP-v relations comprehensively visualize improvements in coronary hemodynamics after PCI. h-SRv is a powerful and sensitive descriptor of the functional gain achieved by PCI, combining information about both pressure gradient and velocity, which are oppositely affected by PCI. Simultaneous assessment of stenosis and microvascular resistance may provide a valuable tool for guidance of PCI.


Assuntos
Angioplastia Coronária com Balão , Cateterismo Cardíaco/instrumentação , Circulação Coronária , Estenose Coronária/diagnóstico , Estenose Coronária/terapia , Velocidade do Fluxo Sanguíneo , Pressão Sanguínea , Angiografia Coronária , Feminino , Hemodinâmica , Humanos , Masculino , Pessoa de Meia-Idade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA