1.
Fetal Diagn Ther ; 38(3): 170-8, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25790745

RESUMO

OBJECTIVE: The aim of this study is to evaluate the interest in the in utero treatment of twin anemia-polycythemia sequence (TAPS). METHODS: The obstetrical and neonatal data on all cases of TAPS followed up in our institution between 2006 and 2013 were reviewed. Statistical analyses were conducted using Bayesian methods. RESULTS: Twenty cases of TAPS were included. Laser therapy or intrauterine transfusion (IUT) was performed on the donor twin in 9 cases. Eleven cases were included in the 'nontreated' group (managed expectantly or diagnosed at birth). The gestational age at diagnosis was lower in the group with treated TAPS [difference (diff) = -22.20 days (-57.13, 14.28), probability (Pr) (diff >0) = 10.6%]. The rate of preterm premature rupture of membranes was higher in the group with treated TAPS [diff = 22.5% (-14, 57), Pr (diff >0) = 89%], but overall mortality was similar. The interval between diagnosis and delivery was longer [diff = 44.37 days (9.41, 77.90), Pr (diff >0) = 99.2%], the TAPS resolution rate was higher [diff = 49.9% (12, 81), Pr (diff >0) = 99.4%], and the neonatal transfusion rate was lower [diff = -30.5% (-60, 0), Pr (diff >0) = 2.6%] in the treated group. CONCLUSION: In utero treatment for TAPS is associated with a higher resolution rate of TAPS and a longer time between diagnosis and birth, but overall mortality is the same as with expectant management.


Assuntos
Anemia/terapia , Transfusão de Sangue Intrauterina/métodos , Transfusão Feto-Fetal/terapia , Fotocoagulação a Laser , Policitemia/terapia , Adulto , Anemia/cirurgia , Feminino , Transfusão Feto-Fetal/cirurgia , Idade Gestacional , Humanos , Policitemia/cirurgia , Gravidez , Resultado do Tratamento
2.
Prenat Diagn ; 35(3): 281-8, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25484182

RESUMO

OBJECTIVE: The aim of this study is to analyze the relevance of the prenatal and postnatal diagnostic parameters of twin anemia-polycythemia sequence (TAPS). METHODS: Diagnostic data of all cases of TAPS followed in our institution between 2006 and 2013 were reviewed. Statistical analyses were conducted using Bayesian methods. RESULTS: Twenty cases of TAPS were included. We found a relationship between the hemoglobin level and the middle cerebral artery peak systolic velocity (coefficient -0.25 [-0.34, -0.15], Pr(coef < 0) = 99.99%). Sensitivity and specificity of the prenatal diagnosis were 71% and 50%, respectively, regarding the correspondence with postnatal diagnosis. There was no correlation between the number [odds ratio (OR) = 0.89 [0.72, 1.10], Pr(OR > 1) = 14.8%)], the mean diameter (OR = 0.98 [0.32, 3.06], Pr(OR > 1) = 48.9%), or the total diameter (OR = 0.79 [0.36, 1.53], Pr(OR > 1) = 26.3%) of arteriovenous anastomoses and the severity of TAPS. CONCLUSION: Middle cerebral artery peak systolic velocity is a reliable tool for estimating the hemoglobin level in cases of TAPS. The correspondence between prenatal and postnatal diagnosis is imperfect. Further studies are required to evaluate opportunity of widening postnatal diagnostic criteria. © 2014 John Wiley & Sons, Ltd.


Assuntos
Anemia Neonatal/diagnóstico , Velocidade do Fluxo Sanguíneo , Transfusão Feto-Fetal/diagnóstico , Hemoglobinas/metabolismo , Artéria Cerebral Média/diagnóstico por imagem , Policitemia/diagnóstico , Gravidez de Gêmeos , Gêmeos Monozigóticos , Adulto , Anemia Neonatal/diagnóstico por imagem , Anemia Neonatal/metabolismo , Teorema de Bayes , Estudos de Coortes , Feminino , Transfusão Feto-Fetal/diagnóstico por imagem , Transfusão Feto-Fetal/metabolismo , Idade Gestacional , Humanos , Recém-Nascido , Policitemia/diagnóstico por imagem , Policitemia/metabolismo , Gravidez , Estudos Prospectivos , Ultrassonografia Pré-Natal , Adulto Jovem