Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 40
Filtrar
1.
J Am Geriatr Soc ; 67(7): 1370-1378, 2019 07.
Artigo em Inglês | MEDLINE | ID: mdl-30892695

RESUMO

OBJECTIVE: To determine whether burden of multiple chronic conditions (MCCs) influences the risk of receiving inappropriate vs appropriate device therapies. DESIGN: Retrospective cohort study. SETTING: Seven US healthcare delivery systems. PARTICIPANTS: Adults with left ventricular systolic dysfunction receiving an implantable cardioverter-defibrillator (ICD) for primary prevention. MEASUREMENTS: Data on 24 comorbid conditions were captured from electronic health records and categorized into quartiles of comorbidity burden (0-3, 4-5, 6-7 and 8-16). Incidence of ICD therapies (shock and antitachycardia pacing [ATP] therapies), including appropriateness, was collected for 3 years after implantation. Outcomes included time to first ICD therapy, total ICD therapy burden, and risk of inappropriate vs appropriate ICD therapy. RESULTS: Among 2235 patients (mean age = 69 ± 11 years, 75% men), the median number of comorbidities was 6 (interquartile range = 4-8), with 98% having at least two comorbidities. During a mean 2.2 years of follow-up, 18.3% of patients experienced at least one appropriate therapy and 9.9% experienced at least one inappropriate therapy. Higher comorbidity burden was associated with an increased risk of first inappropriate therapy (adjusted hazard ratio [HR] = 1.94 [95% confidence interval {CI} = 1.14-3.31] for 4-5 comorbidities; HR = 2.25 [95% CI = 1.25-4.05] for 6-7 comorbidities; and HR = 2.91 [95% CI = 1.54-5.50] for 8-16 comorbidities). Participants with 8-16 comorbidities had a higher total burden of ICD therapy (adjusted relative risk [RR] = 2.12 [95% CI = 1.43-3.16]), a higher burden of inappropriate therapy (RR = 3.39 [95% CI = 1.67-6.86]), and a higher risk of receiving inappropriate vs appropriate therapy (RR = 1.74 [95% CI = 1.07-2.82]). Comorbidity burden was not significantly associated with receipt of appropriate ICD therapies. Patterns were similar when separately examining shock or ATP therapies. CONCLUSIONS: In primary prevention ICD recipients, MCC burden was independently associated with an increased risk of inappropriate but not appropriate device therapies. Comorbidity burden should be considered when engaging patients in shared decision making about ICD implantation.


Assuntos
Desfibriladores Implantáveis , Multimorbidade , Disfunção Ventricular Esquerda/terapia , Idoso , Morte Súbita Cardíaca/prevenção & controle , Feminino , Humanos , Masculino , Prevenção Primária , Estudos Retrospectivos , Fatores de Risco , Estados Unidos
2.
J Am Heart Assoc ; 7(7)2018 03 26.
Artigo em Inglês | MEDLINE | ID: mdl-29581222

RESUMO

BACKGROUND: Primary prevention implantable cardioverter-defibrillators (ICDs) reduce mortality in selected patients with left ventricular systolic dysfunction by delivering therapies (antitachycardia pacing or shocks) to terminate potentially lethal arrhythmias; inappropriate therapies also occur. We assessed device therapies among adults receiving primary prevention ICDs in 7 healthcare systems. METHODS AND RESULTS: We linked medical record data, adjudicated device therapies, and the National Cardiovascular Data Registry ICD Registry. Survival analysis evaluated therapy probability and predictors after ICD implant from 2006 to 2009, with attention to Centers for Medicare and Medicaid Services Coverage With Evidence Development subgroups: left ventricular ejection fraction, 31% to 35%; nonischemic cardiomyopathy <9 months' duration; and New York Heart Association class IV heart failure with cardiac resynchronization therapy defibrillator. Among 2540 patients, 35% were <65 years old, 26% were women, and 59% were white. During 27 (median) months, 738 (29%) received ≥1 therapy. Three-year therapy risk was 36% (appropriate, 24%; inappropriate, 12%). Appropriate therapy was more common in men (adjusted hazard ratio [HR], 1.84; 95% confidence interval [CI], 1.43-2.35). Inappropriate therapy was more common in patients with atrial fibrillation (adjusted HR, 2.20; 95% CI, 1.68-2.87), but less common among patients ≥65 years old versus younger (adjusted HR, 0.72; 95% CI, 0.54-0.95) and in recent implants (eg, in 2009 versus 2006; adjusted HR, 0.66; 95% CI, 0.46-0.95). In Centers for Medicare and Medicaid Services Coverage With Evidence Development analysis, inappropriate therapy was less common with cardiac resynchronization therapy defibrillator versus single chamber (adjusted HR, 0.55; 95% CI, 0.36-0.84); therapy risk did not otherwise differ for Centers for Medicare and Medicaid Services Coverage With Evidence Development subgroups. CONCLUSIONS: In this community cohort of primary prevention patients receiving ICD, therapy delivery varied across demographic and clinical characteristics, but did not differ meaningfully for Centers for Medicare and Medicaid Services Coverage With Evidence Development subgroups.


Assuntos
Arritmias Cardíacas/prevenção & controle , Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis , Cardioversão Elétrica/instrumentação , Prevenção Primária/instrumentação , Disfunção Ventricular Esquerda/terapia , Idoso , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/mortalidade , Arritmias Cardíacas/fisiopatologia , Centers for Medicare and Medicaid Services, U.S. , Cardioversão Elétrica/efeitos adversos , Cardioversão Elétrica/mortalidade , Feminino , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Estados Unidos , Disfunção Ventricular Esquerda/diagnóstico , Disfunção Ventricular Esquerda/mortalidade , Disfunção Ventricular Esquerda/fisiopatologia , Função Ventricular Esquerda
3.
J Am Heart Assoc ; 6(11)2017 Nov 09.
Artigo em Inglês | MEDLINE | ID: mdl-29122811

RESUMO

BACKGROUND: In US clinical practice, many patients who undergo placement of an implantable cardioverter-defibrillator (ICD) for primary prevention of sudden cardiac death receive dual-chamber devices. The superiority of dual-chamber over single-chamber devices in reducing the risk of inappropriate ICD shocks in clinical practice has not been established. The objective of this study was to compare risk of adverse outcomes, including inappropriate shocks, between single- and dual-chamber ICDs for primary prevention. METHODS AND RESULTS: We identified patients receiving a single- or dual-chamber ICD for primary prevention who did not have an indication for pacing from 15 hospitals within 7 integrated health delivery systems in the Longitudinal Study of Implantable Cardioverter-Defibrillators from 2006 to 2009. The primary outcome was time to first inappropriate shock. ICD shocks were adjudicated for appropriateness. Other outcomes included all-cause hospitalization, heart failure hospitalization, and death. Patient, clinician, and hospital-level factors were accounted for using propensity score weighting methods. Among 1042 patients without pacing indications, 54.0% (n=563) received a single-chamber device and 46.0% (n=479) received a dual-chamber device. In a propensity-weighted analysis, device type was not significantly associated with inappropriate shock (hazard ratio, 0.91; 95% confidence interval, 0.59-1.38 [P=0.65]), all-cause hospitalization (hazard ratio, 1.03; 95% confidence interval, 0.87-1.21 [P=0.76]), heart failure hospitalization (hazard ratio, 0.93; 95% confidence interval, 0.72-1.21 [P=0.59]), or death (hazard ratio, 1.19; 95% confidence interval, 0.93-1.53 [P=0.17]). CONCLUSIONS: Among patients who received an ICD for primary prevention without indications for pacing, dual-chamber devices were not associated with lower risk of inappropriate shock or differences in hospitalization or death compared with single-chamber devices. This study does not justify the use of dual-chamber devices to minimize inappropriate shocks.


Assuntos
Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis/efeitos adversos , Insuficiência Cardíaca/terapia , Prevenção Primária/métodos , Sistema de Registros , Idoso , Morte Súbita Cardíaca/epidemiologia , Desenho de Equipamento , Feminino , Insuficiência Cardíaca/mortalidade , Humanos , Incidência , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Taxa de Sobrevida/tendências , Resultado do Tratamento , Estados Unidos/epidemiologia
4.
Heart ; 103(7): 529-537, 2017 04.
Artigo em Inglês | MEDLINE | ID: mdl-27742796

RESUMO

OBJECTIVE: Patients with chronic kidney disease (CKD) have higher risk of sudden cardiac death; however, they may not receive implantable cardioverter defibrillators (ICDs), in part due to higher risk of complications. We evaluated whether CKD is associated with greater risk of device-delivered shocks/antitachycardia pacing (ATP) therapies among patients receiving a primary prevention ICD. METHODS: We studied participants in the observational Cardiovascular Research Network Longitudinal Study of Implantable Cardioverter Defibrillators. CKD was defined as estimated glomerular filtration rate (eGFR) <60 mL/min/1.73 m2. Outcomes included all delivered shocks/ATPs therapies and type of shock/ATP therapies (inappropriate or appropriate, determined by physician adjudication) within the 3 years. We evaluated the associations between CKD and time to first device therapy, burden of device therapy, and inappropriate versus appropriate device therapy, adjusting for demographics, comorbidity, laboratory values and medication use. RESULTS: Among 2161 participants, 1066 (49.3%) had CKD (eGFR 44±11 mL/min/1.73 m2) at ICD implantation. During mean of 2.26±0.89 years, 9.8% and 18.5% of participants had at least one inappropriate and appropriate shock/ATP therapies, respectively. CKD was not associated with time to first shock/ATP therapies (adjusted HR 0.87, 95% CI 0.73 to 1.05), overall burden of shock/ATP therapies (adjusted relative rate 0.93, 95% CI 0.74 to 1.17) or inappropriate versus appropriate shock/ATP therapies (adjusted relative risk 0.88, 95% CI 0.68 to 1.14) compared with not having CKD. CONCLUSIONS: In adults receiving a primary prevention ICD, mild-to-moderate CKD was not associated with the timing, burden or appropriateness of subsequent device therapy. Potential concern for inappropriate ICD-delivered therapies should not preclude ICDs among eligible patients with CKD.


Assuntos
Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis , Cardioversão Elétrica/instrumentação , Insuficiência Cardíaca/terapia , Rim/fisiopatologia , Prevenção Primária/instrumentação , Insuficiência Renal Crônica/fisiopatologia , Idoso , Idoso de 80 Anos ou mais , Morte Súbita Cardíaca/etiologia , Cardioversão Elétrica/efeitos adversos , Feminino , Taxa de Filtração Glomerular , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/fisiopatologia , Humanos , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Falha de Prótese , Insuficiência Renal Crônica/diagnóstico , Insuficiência Renal Crônica/mortalidade , Fatores de Risco , Volume Sistólico , Fatores de Tempo , Resultado do Tratamento , Estados Unidos , Função Ventricular Esquerda
5.
J Am Heart Assoc ; 4(6): e002005, 2015 Jun 02.
Artigo em Inglês | MEDLINE | ID: mdl-26037083

RESUMO

BACKGROUND: Patient sex and age may influence rates of death after receiving an implantable cardioverter-defibrillator for primary prevention. Differences in outcomes other than mortality and whether these differences vary by heart failure symptoms, etiology, and left ventricular ejection fraction are not well characterized. METHODS AND RESULTS: We studied 2954 patients with left ventricular ejection fraction ≤0.35 undergoing first-time implantable cardioverter-defibrillator for primary prevention within the Cardiovascular Research Network; 769 patients (26%) were women, and 2827 (62%) were aged >65 years. In a median follow-up of 2.4 years, outcome rates per 1000 patient-years were 109 for death, 438 for hospitalization, and 111 for heart failure hospitalizations. Procedure-related complications occurred in 8.36%. In multivariable models, women had significantly lower risks of death (hazard ratio 0.67, 95% CI 0.56 to 0.80) and heart failure hospitalization (hazard ratio 0.82, 95% CI 0.68 to 0.98) and higher risks for complications (hazard ratio 1.38, 95% CI 1.01 to 1.90) than men; patients aged >65 years had higher risks of death (hazard ratio 1.55, 95% CI 1.30 to 1.86) and heart failure hospitalization (hazard ratio 1.25, 95% CI 1.05 to 1.49) than younger patients. Age and sex differences were generally consistent in strata according to symptoms, etiology, and severity of left ventricular systolic dysfunction, except the higher risk of complications in women, which differed by New York Heart Association classification (P=0.03 for sex-New York Heart Association interaction), and the risk of heart failure hospitalization in older patients, which differed by etiology of heart failure (P=0.05 for age-etiology interaction). CONCLUSIONS: The burden of adverse outcomes after receipt of an implantable cardioverter-defibrillator for primary prevention is substantial and varies according to patient age and sex. These differences in outcome generally do not vary according to baseline heart failure characteristics.


Assuntos
Desfibriladores Implantáveis/estatística & dados numéricos , Fatores Etários , Idoso , Doenças Cardiovasculares/mortalidade , Doenças Cardiovasculares/cirurgia , Desfibriladores Implantáveis/efeitos adversos , Feminino , Insuficiência Cardíaca/mortalidade , Hospitalização/estatística & dados numéricos , Humanos , Masculino , Pessoa de Meia-Idade , Implantação de Prótese/mortalidade , Implantação de Prótese/estatística & dados numéricos , Fatores de Risco , Fatores Sexuais , Estados Unidos/epidemiologia
6.
Am J Cardiol ; 115(2): 196-201, 2015 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-25465932

RESUMO

The efficacy of omega-3 polyunsaturated fatty acids (n-3 PUFAs) in preventing recurrence of atrial fibrillation (AF) is controversial and their effects on inflammation and oxidative stress in this population are not known. This study examined the effects of high-dose marine n-3 PUFAs added to conventional therapy on the recurrence of AF and on markers of inflammation and oxidative stress. Patients with paroxysmal or persistent AF were randomized to n-3 PUFAs (4 g/day; n = 126) or placebo (n = 64) in a 2:1 ratio in a prospective, double-blind, placebo-controlled, parallel group study. The primary outcome was time to recurrence of AF. Secondary outcomes were changes in biomarkers of inflammation (serum interleukin [IL]-6, IL-8, IL-10, tissue necrosis factor alpha, monocyte chemoattractant protein-1, and vascular endothelial growth factor), N-terminal-pro-brain-type natriuretic peptide, and oxidative stress (urinary F2-isoprostanes). AF recurred in 74 patients (58.7%) randomized to n-3 PUFAs and in 30 patients (46.9%) who received placebo; time to recurrence of AF did not differ significantly in the 2 groups (hazard ratio 1.20; 95% confidence interval 0.76 to 1.90, adjusted p = 0.438). Compared with placebo, n-3 PUFAs did not result in clinically meaningful changes in concentrations of inflammatory markers, N-terminal-pro-brain-type natriuretic peptide or F2-isoprostanes. In conclusion, in patients with paroxysmal or persistent AF, treatment with n-3 PUFAs 4 g/day did not reduce the recurrence of AF, nor was it associated with clinically important effects on concentrations of markers of inflammation and oxidative stress. (Clinical trial registration number, NCT 00552084.).


Assuntos
Fibrilação Atrial/metabolismo , Suplementos Nutricionais , Ácidos Graxos Ômega-3/farmacologia , Inflamação/dietoterapia , Estresse Oxidativo , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/prevenção & controle , Biomarcadores/sangue , Citocinas/sangue , Método Duplo-Cego , Feminino , Seguimentos , Humanos , Incidência , Inflamação/metabolismo , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Recidiva , Resultado do Tratamento , Estados Unidos/epidemiologia
7.
BMJ Case Rep ; 20142014 Feb 11.
Artigo em Inglês | MEDLINE | ID: mdl-24518395

RESUMO

A 59-year-old man presented to the emergency department with lightheadedness. He had started intranasal administration of ophthalmic timolol for the prevention of epistaxis associated with hereditary haemorrhagic telangiectasia approximately 3 weeks earlier with excellent response. His heart rate was about half its normal rate, an ECG revealed sinus bradycardia, and it was determined he had significant cardiac issues in his family history. Essentially all other tests were normal. The discontinuation of the intranasal use of timolol resolved any further episodes of lightheadedness and bradycardia. It was determined through genetic testing that he is an intermediate metaboliser of CYP2D6, the main enzyme contributing to the metabolism of timolol. This explains the development of the bradycardia after intranasal timolol use. The metabolising variants of CYP2D6 need to be considered when prescribing medications metabolised by this enzyme, so possible adverse effects can be avoided.


Assuntos
Antagonistas Adrenérgicos beta/efeitos adversos , Bradicardia/induzido quimicamente , Epistaxe/prevenção & controle , Telangiectasia Hemorrágica Hereditária/complicações , Timolol/efeitos adversos , Administração Intranasal , Antagonistas Adrenérgicos beta/metabolismo , Citocromo P-450 CYP2D6/genética , Citocromo P-450 CYP2D6/metabolismo , Epistaxe/etiologia , Humanos , Masculino , Pessoa de Meia-Idade , Soluções Oftálmicas , Timolol/metabolismo
8.
Am J Cardiol ; 112(12): 1973-9, 2013 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-24075284

RESUMO

Dabigatran has been associated with greater risk of myocardial infarction (MI) than warfarin. It is unknown whether the increased risk is unique to dabigatran, an adverse effect shared by other oral direct thrombin inhibitors (DTIs), or the result of a protective effect of warfarin against MI. To address these questions, we systematically searched MEDLINE and performed a meta-analysis on randomized trials that compared oral DTIs with warfarin for any indication with end point of MIs after randomization. We furthermore performed a secondary meta-analysis on atrial fibrillation stroke prevention trials with alternative anticoagulants compared with warfarin with end point of MIs after randomization. A total of 11 trials (39,357 patients) that compared warfarin to DTIs (dabigatran, ximelagatran, and AZD0837) were identified. In these trials, patients treated with oral DTIs were more likely to experience an MI than their counterparts treated with warfarin (285 of 23,333 vs 133 of 16,024, odds ratio 1.35, 95% confidence interval 1.10 to 1.66, p = 0.005). For secondary analysis, 8 studies (69,615 patients) were identified that compared warfarin with alternative anticoagulant including factor Xa inhibitors, DTIs, aspirin, and clopidogrel. There was no significant advantage in the rate of MIs with the use of warfarin versus comparators (odds ratio 1.06, 95% confidence interval 0.85 to 1.34, p = 0.59). In conclusion, our data suggest that oral DTIs were associated with increased risk of MI. This increased risk appears to be a class effect of these agents, not a specific phenomenon unique to dabigatran or protective effect of warfarin. These findings support the need for enhanced postmarket surveillance of oral DTIs and other novel agents.


Assuntos
Antitrombinas/efeitos adversos , Benzimidazóis/efeitos adversos , Infarto do Miocárdio/induzido quimicamente , beta-Alanina/análogos & derivados , Amidinas/efeitos adversos , Anticoagulantes/uso terapêutico , Fibrilação Atrial/complicações , Fibrilação Atrial/tratamento farmacológico , Azetidinas/efeitos adversos , Benzilaminas/efeitos adversos , Dabigatrana , Humanos , Ensaios Clínicos Controlados Aleatórios como Assunto , Acidente Vascular Cerebral/complicações , Varfarina/uso terapêutico , beta-Alanina/efeitos adversos
9.
Circ Cardiovasc Qual Outcomes ; 5(6): e78-85, 2012 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23170006

RESUMO

BACKGROUND: Implantable cardioverter-defibrillators (ICDs) are increasingly used for primary prevention after randomized, controlled trials demonstrating that they reduce the risk of death in patients with left ventricular systolic dysfunction. The extent to which the clinical characteristics and long-term outcomes of unselected, community-based patients with left ventricular systolic dysfunction undergoing primary prevention ICD implantation in a real-world setting compare with those enrolled in the randomized, controlled trials is not well characterized. This study is being conducted to address these questions. METHODS AND RESULTS: The study cohort includes consecutive patients undergoing primary prevention ICD placement between January 1, 2006 and December 31, 2009 in 7 health plans. Baseline clinical characteristics were acquired from the National Cardiovascular Data Registry ICD Registry. Longitudinal data collection is underway, and will include hospitalization, mortality, and resource use from standardized health plan data archives. Data regarding ICD therapies will be obtained through chart abstraction and adjudicated by a panel of experts in device therapy. Compared with the populations of primary prevention ICD therapy randomized, controlled trials, the cohort (n=2621) is on average significantly older (by 2.5-6.5 years), more often female, more often from racial and ethnic minority groups, and has a higher burden of coexisting conditions. The cohort is similar, however, to a national population undergoing primary prevention ICD placement. CONCLUSIONS: Patients undergoing primary prevention ICD implantation in this study differ from those enrolled in the randomized, controlled trials that established the efficacy of ICDs. Understanding a broad range of health outcomes, including ICD therapies, will provide patients, clinicians, and policy makers with contemporary data to inform decision-making.


Assuntos
Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis , Cardioversão Elétrica/instrumentação , Prevenção Primária/métodos , Disfunção Ventricular Esquerda/terapia , Idoso , Distribuição de Qui-Quadrado , Morte Súbita Cardíaca/etiologia , Cardioversão Elétrica/efeitos adversos , Cardioversão Elétrica/mortalidade , Feminino , Hospitalização , Humanos , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Sistema de Registros , Projetos de Pesquisa , Fatores de Tempo , Resultado do Tratamento , Estados Unidos , Disfunção Ventricular Esquerda/complicações , Disfunção Ventricular Esquerda/diagnóstico , Disfunção Ventricular Esquerda/mortalidade
10.
ACM BCB ; 2012: 313-320, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32355913

RESUMO

Genome-wide association studies (GWAS) analyze genetic variation (SNPs) across the entire human genome, searching for SNPs that are associated with certain phenotypes, most often diseases, such as breast cancer. In GWAS, we seek a ranking of SNPs in terms of their relevance to the given phenotype. However, because certain SNPs are known to be highly correlated with one another across individuals, it can be beneficial to take into account these correlations when ranking. If a SNP appears associated with the phenotype, and we question whether this association is real, the extent to which its neighbors (correlated SNPs) also appear associated can be informative. Therefore, we propose CollectRank, a ranking approach which allows SNPs to reinforce one another via the correlation structure. CollectRank is loosely analogous to the well-known PageRank algorithm. We first evaluate CollectRank on synthetic data generated from a variety of genetic models under different settings. The numerical results suggest CollectRank can significantly outperform common GWAS methods at the cost of a small amount of extra computation. We further evaluate CollectRank on two real-world GWAS on breast cancer and atrial fibrillation/flutter, and CollectRank performs well in both studies. We finally provide a theoretical analysis that also suggests CollectRank's advantages.

11.
Artigo em Inglês | MEDLINE | ID: mdl-23367189

RESUMO

Electronic Health Records (EHR) contain large amounts of useful information that could potentially be used for building models for predicting onset of diseases. In this study, we have investigated the use of free-text and coded data in Marshfield Clinic's EHR, individually and in combination for building machine learning based models to predict the first ever episode of atrial fibrillation and/or atrial flutter (AFF). We trained and evaluated our AFF models on the EHR data across different time intervals (1, 3, 5 and all years) prior to first documented onset of AFF. We applied several machine learning methods, including naïve bayes, support vector machines (SVM), logistic regression and random forests for building AFF prediction models and evaluated these using 10-fold cross-validation approach. On text-based datasets, the best model achieved an F-measure of 60.1%, when applied exclusively to coded data. The combination of textual and coded data achieved comparable performance. The study results attest to the relative merit of utilizing textual data to complement the use of coded data for disease onset prediction modeling.


Assuntos
Fibrilação Atrial/diagnóstico , Flutter Atrial/diagnóstico , Registros Eletrônicos de Saúde , Humanos
12.
BMC Med Educ ; 10: 5, 2010 Jan 25.
Artigo em Inglês | MEDLINE | ID: mdl-20100347

RESUMO

BACKGROUND: Available evidence suggests that international medical graduates have improved the availability of U.S. health care while maintaining academic standards. We wondered whether studies had been conducted to address how international graduates were treated in the post-graduate selection process compared to U.S. graduates. METHODS: We conducted a Medline search for research on the selection process. RESULTS: Two studies provide strong evidence that psychiatry and family practice programs respond to identical requests for applications at least 80% more often for U.S. medical graduates than for international graduates. In a third study, a survey of surgical program directors, over 70% perceived that there was discrimination against international graduates in the selection process. CONCLUSIONS: There is sufficient evidence to support action against discrimination in the selection process. Medical organizations should publish explicit proscriptions of discrimination against international medical graduates (as the American Psychiatric Association has done) and promote them in diversity statements. They should develop uniform and transparent policies for program directors to use to select applicants that minimize the possibility of non-academic discrimination, and the accreditation organization should monitor whether it is occurring. Whether there should be protectionism for U.S. graduates or whether post-graduate medical education should be an unfettered meritocracy needs to be openly discussed by medicine and society.


Assuntos
Médicos Graduados Estrangeiros , Internato e Residência , Preconceito , Humanos , Literatura de Revisão como Assunto , Estados Unidos
13.
Clin Med Res ; 8(1): 1-6, 2010 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-19920163

RESUMO

OBJECTIVE: Determine and compare the prevalence of known risk factors for cardiovascular disease among unselected individuals presenting with their first ever episode of atrial flutter (AFL) and atrial fibrillation (AF). STUDY DESIGN AND SETTING: We evaluated 11 pre-selected clinical variables including age, sex, smoking history and other potential cardiac risk factors. Using the resources of the Marshfield Epidemiologic Study Area, a population-based database, all newly diagnosed cases of either AFL or AF in the region during a 4-year period were identified. RESULTS: Among the 472 incident cases, 76 (16.1%) had AFL and 396 (83.9%) had AF. Compared to those with AF, subjects with AFL were more likely to have had a history of chronic obstructive pulmonary disease (25% vs. 12%, P = 0.006), heart failure (28% vs. 17%, P = 0.05), and smoking (49% vs. 37%, P = 0.06). Hypertension, on the other hand, was more common among individuals with AF (63% vs. 47%, P = 0.01). CONCLUSION: This study represents the first report to evaluate potential differences in the conditions associated with the development of AFL versus AF. Research into the mechanisms of atrial arrhythmogenesis may lead to improved preventive and therapeutic interventions.


Assuntos
Fibrilação Atrial/diagnóstico , Flutter Atrial/diagnóstico , Adulto , Idoso , Idoso de 80 Anos ou mais , Fibrilação Atrial/classificação , Fibrilação Atrial/complicações , Flutter Atrial/classificação , Flutter Atrial/complicações , Estudos de Coortes , Comorbidade , Eletrocardiografia/métodos , Eletrofisiologia/métodos , Feminino , Humanos , Hipertensão/patologia , Masculino , Pessoa de Meia-Idade , Doença Pulmonar Obstrutiva Crônica/complicações , Doença Pulmonar Obstrutiva Crônica/diagnóstico , Risco , Fatores de Risco
14.
Am Heart J ; 158(2): 224-9, 2009 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-19619698

RESUMO

BACKGROUND: Fewer women than men undergo implantable cardioverter defibrillator (ICD) implantation for the primary prevention of sudden cardiac death. The criteria used to select patients for ICD implantation may be more permissive among men than for women. We hypothesized that women who undergo primary prevention ICD implantation more often meet strict trial enrollment criteria for this therapy. METHODS: We studied 59,812 patients in the National Cardiovascular Data Registry ICD registry undergoing initial primary prevention ICD placement between January 2005 and April 2007. Patients were classified as meeting or not meeting enrollment criteria of either the MADIT-II or SCD-HeFT trials. Multivariable analyses assessed the association between gender and concordance with trial criteria adjusting for demographic, clinical, and system characteristics. RESULTS: Among the cohort, 27% (n = 16,072) were women. Overall, 85.2% of women and 84.5% of men met enrollment criteria of either trial (P = .05). In multivariable analyses, women were equally likely to meet trial criteria (OR 1.04, 95% CI 0.99-1.10) than men. Significantly more women than men met the trial enrollment criteria among patients older than age 65 (86.6% of women vs 85.3% of men, OR 1.11, 95% CI 1.03-1.19), but this difference was not found among younger patients (82.5% of women vs 83.0% of men, OR 0.97, 95% CI 0.89-1.07). CONCLUSIONS: In a national cohort undergoing primary prevention ICD implantation, older women were only slightly more likely then men to meet the enrollment criteria for MADIT II or SCD-HeFT. Relative overutilization in men is not an important explanation for gender differences in ICD implantation.


Assuntos
Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis/estatística & dados numéricos , Seleção de Pacientes , Prevenção Primária , Idoso , Idoso de 80 Anos ou mais , Estudos de Coortes , Definição da Elegibilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Sistema de Registros , Fatores Sexuais , Estados Unidos
15.
Circulation ; 119(8): 1078-84, 2009 Mar 03.
Artigo em Inglês | MEDLINE | ID: mdl-19221223

RESUMO

BACKGROUND: Women are at higher risk than men for adverse events with certain invasive cardiac procedures. Our objective was to compare rates of in-hospital adverse events in men and women receiving implantable cardioverter- defibrillator (ICD) therapy in community practice. METHODS AND RESULTS: Using the National Cardiovascular Data Registry ICD Registry, we identified patients undergoing first-time ICD implantation between January 2006 and December 2007. Outcomes included in-hospital adverse events after ICD implantation. Multivariable analysis assessed the association between gender and in-hospital adverse events, with adjustment for demographic, clinical, procedural, physician, and hospital characteristics. Of 161,470 patients, 73% were male, and 27% were female. Women were more likely to have a history of heart failure (81% versus 77%, P<0.01), worse New York Heart Association functional status (57% versus 50% in class III and IV, P<0.01), and nonischemic cardiomyopathy (44% versus 27%, P<0.01) and were more likely to receive biventricular ICDs (39% versus 34%, P<0.01). In unadjusted analyses, women were more likely to experience any adverse event (4.4% versus 3.3%, P<0.001) and major adverse events (2.0% versus 1.1%, P<0.001). In multivariable models, women had a significantly higher risk of any adverse event (OR 1.32, 95% CI 1.24 to 1.39) and major adverse events (OR 1.71, 95% CI 1.57 to 1.86). CONCLUSIONS: Women are more likely than men to have in-hospital adverse events related to ICD implantation. Efforts are needed to understand the reasons for higher ICD implantation-related adverse event rates in women and to develop strategies to reduce the risk of these events.


Assuntos
Desfibriladores Implantáveis/efeitos adversos , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Caracteres Sexuais , Idoso , Idoso de 80 Anos ou mais , Estudos de Coortes , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/prevenção & controle , Sistema de Registros , Fatores de Risco
16.
Blood ; 111(8): 4106-12, 2008 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-18250228

RESUMO

Warfarin is an effective, commonly prescribed anticoagulant used to treat and prevent thrombotic events. Because of historically high rates of drug-associated adverse events, warfarin remains underprescribed. Further, interindividual variability in therapeutic dose mandates frequent monitoring until target anticoagulation is achieved. Genetic polymorphisms involved in warfarin metabolism and sensitivity have been implicated in variability of dose. Here, we describe a novel variant that influences warfarin requirements. To identify additional genetic variants that contribute to warfarin requirements, screening of DNA variants in additional genes that code for drug-metabolizing enzymes and drug transport proteins was undertaken using the Affymetrix drug-metabolizing enzymes and transporters panel. A DNA variant (rs2108622; V433M) in cytochrome P450 4F2 (CYP4F2) was associated with warfarin dose in 3 independent white cohorts of patients stabilized on warfarin representing diverse geographic regions in the United States and accounted for a difference in warfarin dose of approximately 1 mg/day between CC and TT subjects. Genetic variation of CYP4F2 was associated with a clinically relevant effect on warfarin requirement.


Assuntos
Sistema Enzimático do Citocromo P-450/genética , Polimorfismo de Nucleotídeo Único/genética , Varfarina/administração & dosagem , Varfarina/farmacologia , Família 4 do Citocromo P450 , Frequência do Gene , Genótipo , Humanos , Modelos Genéticos , Reprodutibilidade dos Testes
17.
Value Health ; 11(3): 365-75, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-17854433

RESUMO

OBJECTIVES: Losses to follow-up and administrative censoring can cloud the interpretation of trial-based economic evaluations. A number of investigators have examined the impact of different levels of adjustment for censoring, including nonadjustment, adjustment of effects only, and adjustment for both costs and effects. Nevertheless, there is a lack of research on the impact of censoring on decision-making. The objective of this study was to estimate the impact of adjustment for censoring on the interpretation of cost-effectiveness results and expected value of perfect information (EVPI), using a trial-based analysis that compared rate- and rhythm-control treatments for persons with atrial fibrillation. METHODS: Three different levels of adjustment for censoring were examined: no censoring of cost and effects, censoring of effects only, and censoring of both costs and effects. In each case, bootstrapping was used to estimate the uncertainty incosts and effects, and the EVPI was calculated to determine the potential worth of further research. RESULTS: Censoring did not impact the adoption decision. Nevertheless, this was not the case for the decision uncertainty or the EVPI. For a threshold of $50,000 per life-year, the EVPI varied between $626,000 (partial censoring) to $117 million (full censoring) for the eligible US population. CONCLUSIONS: The level of adjustment for censoring in trial-based cost-effectiveness analyses can impact on the decisions to fund a new technology and to devote resources for further research. Only when censoring is taken into account for both costs and effects are these decisions appropriately addressed.


Assuntos
Antiarrítmicos/economia , Antiarrítmicos/uso terapêutico , Fibrilação Atrial/economia , Fibrilação Atrial/terapia , Tomada de Decisões , Modelos Econômicos , Idoso , Análise Custo-Benefício , Feminino , Humanos , Masculino , Taxa de Sobrevida
18.
J Interv Card Electrophysiol ; 19(3): 157-64, 2007 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-17805953

RESUMO

OBJECTIVES: We compared characteristics and mortality of patients from a community population meeting enrollment criteria of the second Multicenter Automatic Defibrillator Implantation Trial (MADIT II) to those of the MADIT II subjects. BACKGROUND: MADIT II showed that implantable cardioverter-defibrillators (ICDs) reduce mortality in patients with myocardial infarction (MI) and low left ventricular ejection fraction (LVEF)

Assuntos
Desfibriladores Implantáveis , Infarto do Miocárdio/epidemiologia , Infarto do Miocárdio/mortalidade , Adulto , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Estudos de Coortes , Análise Custo-Benefício , Feminino , Geografia , Humanos , Masculino , Pessoa de Meia-Idade , Risco , Sensibilidade e Especificidade , Função Ventricular Esquerda
19.
Clin Med Res ; 5(1): 8-16, 2007 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-17456829

RESUMO

OBJECTIVES: Warfarin is a commonly prescribed anticoagulant drug used to prevent thromboses that may arise as a consequence of orthopedic and vascular surgery or underlying cardiovascular disease. Warfarin is associated with a notoriously narrow therapeutic window where small variations in dosing may result in hemorrhagic or thrombotic complications. To ultimately improve dosing of warfarin, we evaluated models for stable maintenance dose that incorporated both clinical and genetic factors. METHOD: A model was constructed by evaluating the contribution to dosing variability of the following clinical factors: age, gender, body surface area, and presence or absence of prosthetic heart valves or diabetes. The model was then sequentially expanded by incorporating polymorphisms of cytochrome P450 (CYP) 2C9; vitamin K 2,3 epoxide reductase complex, subunit 1 (VKORC1); gamma carboxylase; factor VII; and apolipoprotein (Apo) E genes. RESULTS: Of genetic factors evaluated in the model, CYP2C9 and VKORC1 each contributed substantially to dose variability, and together with clinical factors explained 56% of the individual variability in stable warfarin dose. In contrast, gamma carboxylase, factor VII and Apo E polymorphisms contributed little to dose variability. CONCLUSION: The importance of CYP2C9 and VKORC1 to patient-specific dose of warfarin has been confirmed, while polymorphisms of gamma carboxylase, factor VII and Apo E genes did not substantially contribute to predictive models for stable warfarin dose.


Assuntos
Anticoagulantes/uso terapêutico , Hidrocarboneto de Aril Hidroxilases/genética , Doenças Cardiovasculares/tratamento farmacológico , Oxigenases de Função Mista/genética , Farmacogenética/métodos , Varfarina/administração & dosagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Ácidos Carboxílicos/metabolismo , Citocromo P-450 CYP2C9 , Esquema de Medicação , Feminino , Testes Genéticos , Humanos , Masculino , Pessoa de Meia-Idade , Polimorfismo Genético , Vitamina K Epóxido Redutases
20.
Cardiology ; 107(4): 412-4, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17284905

RESUMO

A 45-year-old man was diagnosed with new-onset atrial fibrillation. Control of ventricular rate led to spontaneous conversion to sinus rhythm. Subsequent electrocardiograms revealed ST segment changes characteristic of Brugada syndrome. Electrophysiology study demonstrated inducible ventricular fibrillation. During the placement of an implantable cardiac defibrillator the patient was found to have a persistent left superior vena cava. Persistent left superior vena cava is present in 0.3% of cases in autopsy series. To date, persistent left superior vena cava has not been reported in association with Brugada syndrome. We report such a case.


Assuntos
Fibrilação Atrial/terapia , Síndrome de Brugada/terapia , Veia Cava Superior/anormalidades , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Síndrome de Brugada/complicações , Síndrome de Brugada/diagnóstico , Desfibriladores Implantáveis , Cardioversão Elétrica , Eletrocardiografia , Humanos , Masculino , Pessoa de Meia-Idade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA