Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Front Mol Biosci ; 11: 1371426, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38572446

RESUMO

Background: During the last decade, Germany has seen an increased prevalence and a redistribution from undetected to diagnosed diabetes mellitus. Due to this substantial epidemiological development, the number of people with documented type 2 diabetes was 8.7 million in 2022. An estimated two million undiagnosed subjects are to be added. Beyond that, the life expectancy of diabetic subjects is increasing due to more responsive health systems in terms of care. Possible reasons include improved screening of at-risk individuals, the introduction of HbA1c for diagnosis in 2010, and the higher use of risk scores. Additionally, quality aspects of the laboratory methodology should be taken into consideration. Methods: Epidemiology and clinical management of diabetes in Germany are presented in the light of publications retrieved by a selective search of the PubMed database. Additionally, the data from German external quality assessment (EQA) surveys for the measurands glucose in plasma and HbA1c in whole blood, reviewed from 2010 until 2022, were evaluated. Above this, data concerning the analytical performance of near-patient glucometer devices, according to the ISO norm 15197:2013, were analyzed. Results: Two laboratory aspects are in good accordance with the observation of an increase in the diabetes mellitus prevalence when retrospectively reviewing the period 2010 to 2022: First, the analytical performance according to the ISO norm 15197:2013 of the glucometer devices widely used by patients with diabetes for the glucose self-testing, has improved during this period. Secondly, concerning the EQA program of INSTAND, the number of participating laboratories raised significantly in Germany. The spreads of variations of the specified results for plasma glucose remained unchanged between 2010 and 2022, whereas for HbA1c a significant decrease of the result scattering could be observed. Conclusion: These retrospectively established findings testify to an excellent analytical quality of laboratory diagnostics for glucose and HbA1c throughout Germany which may be involved in a better diagnosis and therapy of previously undetected diabetes mellitus.

2.
Front Mol Biosci ; 11: 1373114, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38601324

RESUMO

Background: Quality control (QC), quality assurance, and standardization are crucial for modern diagnostic testing in the field of medical microbiology. The need for efficient QC to ensure accurate laboratory results, treatment, and infection prevention has led to significant efforts in standardizing assay reagents and workflows. External quality assessment (EQA) schemes, like those offered by INSTAND, play a vital role in evaluating in-house and commercial routine diagnostic assays, regarded as mandatory by national and global guidelines. The recent impact of polymerase chain reaction/nucleic acid amplification technology (PCR/NAAT) assays in medical microbiology requires that high-performing assays be distinguished from inadequately performing ones, especially those made by inexperienced suppliers. Objectives: The study assesses the evolving diagnostic performance trends over 2 decades for the detection of EHEC/STEC, Borrelia (B.) burgdorferi, and MRSA/cMRSA. It explores the historical context of assay utilization, participant engagement, and rates of correct results in EQA schemes. The research seeks to identify patterns in assay preferences, participant proficiency, and the challenges encountered in detecting emerging variants or clinical strains. Results: The study highlights the decline in in-house PCR assay usage, the emergence of new diagnostic challenges, and educational aspects within EQA schemes. Specific examples, such as the inclusion, in certain EQA surveys, of EHEC strains carrying stx-2f or B. miyamotoi, highlight the role of EQAs in increasing awareness and diagnostic capabilities. Advancements in MRSA detection, especially through the adoption of commercial assays, demonstrate the impact that technology evolution has had on diagnostic performance. Conclusion: Achieving excellence in diagnostic molecular microbiology involves a multifaceted approach, including well-evaluated assays, careful instrumentation selection, and structured training programs. EQA schemes contribute significantly to this pursuit by providing insights into the evolving diagnostic landscape and identifying areas for improvement in the diagnostic workflow as well as in PCR/NAAT assay design.

3.
Front Mol Biosci ; 11: 1345356, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38357630

RESUMO

As hormonal disorders are linked to several diseases, the accurate quantitation of steroid hormone levels in serum is crucial in order to provide patients with a reliable diagnosis. Mass spectrometry-based methods are regarded as having the highest level of specificity and sensitivity. However, immunoassays are more commonly used in routine diagnostics to measure steroid levels as they are more cost effective and straightforward to conduct. This study analyzes the external quality assessment results for the measurement of testosterone, progesterone and 17ß-estradiol in serum using immunoassays between early 2020 and May 2022. As reference measurement procedures are available for the three steroid hormones, the manufacturer-specific biases were normalized to the reference measurement values. The manufacturer-specific coefficients of variation were predominantly inconspicuous, below 20% for the three hormones when outliers are disregarded, however there were large differences between the various manufacturer collectives. For some collectives, the median bias to the respective reference measurement value was repeatedly greater than ±35%, which is the acceptance limit defined by the German Medical Association. In the case of testosterone and progesterone determination, some collectives tended to consistently over- or underestimate analyte concentrations compared to the reference measurement value, however, for 17ß-estradiol determination, both positive and negative biases were observed. This insufficient level of accuracy suggests that cross-reactivity continues to be a fundamental challenge when antibody detection is used to quantify steroids with a high structural similarity. Distinct improvements in standardization are required to provide accurate analysis and thus, reliable clinical interpretations. The increased accuracy of the AX immunoassay for testosterone measurement, as observed in the INSTAND EQAs between 2020 and 2022, could be the result of a recalibration of the assay and raises hope for further improvement of standardization of immunoassay-based steroid hormone analyses in the coming years.

4.
Sci Rep ; 13(1): 13206, 2023 08 14.
Artigo em Inglês | MEDLINE | ID: mdl-37580353

RESUMO

The COVID-19 pandemic illustrated the important role of diagnostic tests, including lateral flow tests (LFTs), in identifying patients and their contacts to slow the spread of infections. INSTAND performed external quality assessments (EQA) for SARS-CoV-2 antigen detection with lyophilized and chemically inactivated cell culture supernatant of SARS-CoV-2 infected Vero cells. A pre-study demonstrated the suitability of the material. Participants reported qualitative and/or quantitative antigen results using either LFTs or automated immunoassays for five EQA samples per survey. 711 data sets were reported for LFT detection in three surveys in 2021. This evaluation focused on the analytical sensitivity of different LFTs and automated immunoassays. The inter-laboratory results showed at least 94% correct results for non-variant of concern (VOC) SARS-CoV-2 antigen detection for viral loads of ≥ 4.75 × 106 copies/mL and SARS-CoV-2 negative samples. Up to 85% had success for a non-VOC viral load of ~ 1.60 × 106 copies/mL. A viral load of ~ 1.42 × 107 copies/mL of the Delta VOC was reported positive in > 96% of results. A high specificity was found with almost 100% negative SARS-CoV-2 antigen results for HCoV 229E and HCoV NL63 positive samples. Quantitative results correlated with increasing SARS-CoV-2 viral load but showed a broad scatter. This study shows promising SARS-CoV-2 antigen test performance of the participating laboratories, but further investigations with the now predominant Omicron VOC are needed.


Assuntos
COVID-19 , SARS-CoV-2 , Chlorocebus aethiops , Animais , Humanos , Pandemias , Células Vero , COVID-19/diagnóstico , COVID-19/epidemiologia , Testes Imunológicos , Sensibilidade e Especificidade
5.
Diagnostics (Basel) ; 13(12)2023 Jun 09.
Artigo em Inglês | MEDLINE | ID: mdl-37370914

RESUMO

The glycoproteins alpha-fetoprotein (AFP) and carcinoembryonic antigen (CEA) have long been approved as biomarkers for diagnosing and monitoring tumors. International Reference Preparations (IRPs) have been around since 1975. Nevertheless, manufacturer-dependent differences have been reported, indicating a lack of harmonization. This paper analyzes data from 15 external quality assessment (EQA) surveys conducted worldwide between 2018 and 2022. The aim was to gain insight into the longitudinal development of manufacturer-dependent differences for CEA and AFP. In each survey, participating laboratories received two samples with different tumor marker levels. Inter- and intra-assay variability was analyzed and the mean 80% and 90% of the manufacturer collectives were compared to the evaluation criteria of the German Medical Association (RiliBÄK). The median EQA results for CEA revealed manufacturer-dependent differences between the highest and lowest collective of up to 100%; for AFP, the median differences mostly remained below 40%. The coefficients of variation were predominantly low for both markers. We concluded that the current assays for AFP and CEA detection are better harmonized than previously reported. The assays displayed a good robustness; however, a narrowing of the current assessment limits in EQA schemes could further enhance the quality of laboratory testing.

6.
PLoS One ; 18(4): e0285203, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37115793

RESUMO

BACKGROUND: In May 2022, the monkeypox virus (MPXV) spread into non-endemic countries and the global community was quick to test the lessons learned from the SARS-CoV-2 pandemic. Due to its symptomatic resemblance to other diseases, like the non-pox virus varicella zoster (chickenpox), polymerase chain reaction methods play an important role in correctly diagnosing the rash-causing pathogen. INSTAND quickly established a new external quality assessment (EQA) scheme for MPXV and orthopoxvirus (OPXV) DNA detection to assess the current performance quality of the laboratory tests. METHODS: We analyzed quantitative and qualitative data of the first German EQA for MPXV and OPXV DNA detection. The survey included one negative and three MPXV-positive samples with different MPX viral loads. The threshold cycle (Ct) or other measures defining the quantification cycle (Cq) were analyzed in an assay-specific manner. A Passing Bablok fit was used to investigate the performance at laboratory level. RESULTS: 141 qualitative datasets were reported by 131 laboratories for MPXV detection and 68 qualitative datasets by 65 laboratories for OPXV detection. More than 96% of the results were correctly identified as negative and more than 97% correctly identified as positive. An analysis of the reported Ct/Cq values showed a large spread of these values of up to 12 Ct/Cq. Nevertheless, there is a good correlation of results for the different MPXV concentrations at laboratory level. Only a few quantitative results in copies/mL were reported (MPXV: N = 5; OPXV: N = 2), but the results correlated well with the concentration differences between the EQA samples, which were to a power of ten each. CONCLUSION: The EQA results show that laboratories performed well in detecting both MPXV and OPXV. However, Ct/Cq values should be interpreted with caution when conclusions are drawn about the viral load as long as metrological traceability is not granted.


Assuntos
COVID-19 , Mpox , Orthopoxvirus , Humanos , Monkeypox virus/genética , SARS-CoV-2/genética
7.
Front Public Health ; 10: 883564, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35558533

RESUMO

Background: A multi-dimensional model can be a useful tool for estimating the general impact of disease on the different sectors of the healthcare system. We chose the sexually transmitted disease syphilis for our model due to the good quality of reported data in Germany. Methods: The model included gender- and age-stratified incident cases of syphilis (in- and outpatients) provided by a German statutory health insurance company, as well as seroprevalence data on syphilis in first-time blood donors. Age standardized rates were calculated based on the standard German population. The test quality was assessed by extrapolating the number of false-positive and false-negative results based on data from Europe-wide external quality assessment (EQA) schemes. The model analysis was validated with the reported cases and diagnosis-related group (DRG)-statistics from 2010 to 2012. The annual direct and indirect economic burden was estimated based on the outcomes of our model. Results: The standardized results were slightly higher than the results reported between 2010 and 2012. This could be due to an underassessment of cases in Germany or due to limitations of the dataset. The number of estimated inpatients was predicted with an accuracy of 89.8 %. Results from EQA schemes indicated an average sensitivity of 92.8 % and an average specificity of 99.9 % for the recommended sequential testing for syphilis. Based on our model, we estimated a total average minimal annual burden of €20,292,110 for syphilis on the German healthcare system between 2010 and 2012. Conclusions: The linking of claims data, results from EQA schemes, and blood donor surveillance can be a useful tool for assessing the burden of disease on the healthcare system. It can help raise awareness in populations potentially at risk for infectious diseases, demonstrate the need to educate potential risk groups, and may help with predictive cost calculations and planning.


Assuntos
Sífilis , Atenção à Saúde , Humanos , Pacientes Ambulatoriais , Estudos Retrospectivos , Estudos Soroepidemiológicos , Sífilis/diagnóstico , Sífilis/epidemiologia
8.
PLoS One ; 17(1): e0262656, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35051208

RESUMO

SARS-CoV-2, the cause of COVID-19, requires reliable diagnostic methods to track the circulation of this virus. Following the development of RT-qPCR methods to meet this diagnostic need in January 2020, it became clear from interlaboratory studies that the reported Ct values obtained for the different laboratories showed high variability. Despite this the Ct values were explored as a quantitative cut off to aid clinical decisions based on viral load. Consequently, there was a need to introduce standards to support estimation of SARS-CoV-2 viral load in diagnostic specimens. In a collaborative study, INSTAND established two reference materials (RMs) containing heat-inactivated SARS-CoV-2 with SARS-CoV-2 RNA loads of ~107 copies/mL (RM 1) and ~106 copies/mL (RM 2), respectively. Quantification was performed by RT-qPCR using synthetic SARS-CoV-2 RNA standards and digital PCR. Between November 2020 and February 2021, German laboratories were invited to use the two RMs to anchor their Ct values measured in routine diagnostic specimens, with the Ct values of the two RMs. A total of 305 laboratories in Germany were supplied with RM 1 and RM 2. The laboratories were requested to report their measured Ct values together with details on the PCR method they used to INSTAND. This resultant 1,109 data sets were differentiated by test system and targeted gene region. Our findings demonstrate that an indispensable prerequisite for linking Ct values to SARS-CoV-2 viral loads is that they are treated as being unique to an individual laboratory. For this reason, clinical guidance based on viral loads should not cite Ct values. The RMs described were a suitable tool to determine the specific laboratory Ct for a given viral load. Furthermore, as Ct values can also vary between runs when using the same instrument, such RMs could be used as run controls to ensure reproducibility of the quantitative measurements.


Assuntos
Teste de Ácido Nucleico para COVID-19/métodos , COVID-19/diagnóstico , Testes Diagnósticos de Rotina/métodos , RNA Viral/genética , Reação em Cadeia da Polimerase Via Transcriptase Reversa/métodos , SARS-CoV-2/genética , Carga Viral/métodos , COVID-19/epidemiologia , COVID-19/virologia , Genes Virais , Alemanha/epidemiologia , Humanos , Reprodutibilidade dos Testes
9.
Int J Infect Dis ; 104: 85-91, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33359066

RESUMO

OBJECTIVES: The aim of this study was to evaluate the development and status quo of the quality of high throughput in vitro diagnostic testing for tetanus and diphtheria antitoxin antibody (ATX) concentrations based on external quality assessment (EQA) data. METHODS: We analyzed manufacturer-specific data of 22 EQA surveys-each for the detection of tetanus and diphtheria ATX-to check the diagnostic strength of the corresponding in vitro diagnostic systems. RESULTS: While the results were mostly well aligned, individual surveys showed widely dispersed ATX concentrations. The medians of manufacturer collectives deviated from the overall median by up to 8.9-fold in the case of diphtheria ATX and by up to 3.5-fold in the case of tetanus ATX. Such a distribution in the results is particularly critical in the cut-off range for immunity and may lead to an incorrect assessment of vaccination status. CONCLUSION: These results were surprising as there are International Standards for both ATX; however, the results may be linked to the high ATX concentration of the reference material, which deviates considerably from clinically significant concentrations. To increase the accuracy and diagnostic strength of both assays, we recommend a recalibration of the test systems and verification of their traceability to the International Standards.


Assuntos
Antitoxina Diftérica/sangue , Antitoxina Tetânica/sangue , Difteria/imunologia , Humanos , Técnicas Imunológicas/normas , Ensaio de Proficiência Laboratorial , Tétano/imunologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA