Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
J Gen Intern Med ; 36(7): 1914-1920, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33483828

RESUMO

BACKGROUND: In several settings, a shorter time to diagnosis has been shown to lead to improved clinical outcomes. The implementation of a rapid laboratory testing allows for a pre-visit testing in the outpatient clinic, meaning that test results are available during the first outpatient visit. OBJECTIVE: To determine whether the pre-visit laboratory testing leads to a shorter time to diagnosis in the general internal medicine outpatient clinic. DESIGN: An "on-off" trial, allocating subjects to one of two treatment arms in consecutive alternating blocks. PARTICIPANTS: All new referrals to the internal medicine outpatient clinic of a university hospital were included, excluding second opinions. A total of 595 patients were eligible; one person declined to participate, leaving data from 594 patients for analysis. INTERVENTION: In the intervention group, patients had a standardized pre-visit laboratory testing before the first visit. MAIN MEASURES: The primary outcome was the time to diagnosis. Secondary outcomes were the correctness of the preliminary diagnosis on the first day, health care utilization, and patient and physician satisfaction. KEY RESULTS: There was no difference in time to diagnosis between the two groups (median 35 days vs 35 days; hazard ratio 1.03 [0.87-1.22]; p = .71). The pre-visit testing group had higher proportions of both correct preliminary diagnoses on day 1 (24% vs 14%; p = .003) and diagnostic workups being completed on day 1 (10% vs 3%; p < .001). The intervention group had more laboratory tests done (50.0 [interquartile range (IQR) 39.0-69.0] vs 43.0 [IQR 31.0-68.5]; p < .001). Otherwise, there were no differences between the groups. CONCLUSIONS: Pre-visit testing did not lead to a shorter overall time to diagnosis. However, a greater proportion of patients had a correct diagnosis on the first day. Further studies should focus on customizing pre-visit laboratory panels, to improve their efficacy. TRIAL REGISTRATION: NL5009.


Assuntos
Instituições de Assistência Ambulatorial , Humanos , Encaminhamento e Consulta
2.
Ultrasound Obstet Gynecol ; 51(5): 596-603, 2018 May.
Artigo em Inglês | MEDLINE | ID: mdl-28370518

RESUMO

OBJECTIVE: To evaluate the cost-effectiveness of combining cervical-length (CL) measurement and fetal fibronectin (fFN) testing in women with symptoms of preterm labor between 24 and 34 weeks' gestation. METHODS: This was a model-based cost-effectiveness analysis evaluating seven test-treatment strategies based on CL measurement and/or fFN testing in women with symptoms of preterm labor from a societal perspective, in which neonatal outcomes and costs were weighted. Estimates of disease prevalence, test accuracy and costs were based on two recently performed nationwide cohort studies in The Netherlands. RESULTS: Strategies using fFN testing and CL measurement separately to predict preterm delivery are associated with higher costs and incidence of adverse neonatal outcomes compared with strategies that combine both tests. Additional fFN testing when CL is 15-30 mm was considered cost effective, leading to a cost saving of €3919 per woman when compared with a treat-all strategy, with a small deterioration in neonatal health outcomes, namely one additional perinatal death and 21 adverse outcomes per 10 000 women with signs of preterm labor (incremental cost-effectiveness ratios €39 million and €1.9 million, respectively). Implementing this strategy in The Netherlands, a country with about 180 000 deliveries annually, could lead to an annual cost saving of between €2.4 million and €7.6 million, with only a small deterioration in neonatal health outcomes. CONCLUSION: In women with symptoms of preterm labor at 24-34 weeks' gestation, performing additional fFN testing when CL is between 15 and 30 mm is a viable and cost-saving strategy. Copyright © 2017 ISUOG. Published by John Wiley & Sons Ltd.


Assuntos
Medida do Comprimento Cervical/economia , Colo do Útero/química , Fibronectinas/análise , Trabalho de Parto Prematuro/economia , Estudos de Coortes , Análise Custo-Benefício , Feminino , Idade Gestacional , Hospitalização/economia , Hospitalização/estatística & dados numéricos , Humanos , Recém-Nascido , Países Baixos , Trabalho de Parto Prematuro/diagnóstico , Valor Preditivo dos Testes , Gravidez
3.
Int J Lab Hematol ; 38 Suppl 1: 100-9, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-27161194

RESUMO

Verification of hematology analyzers (automated blood cell counters) is mandatory before new hematology analyzers may be used in routine clinical care. The verification process consists of several items which comprise among others: precision, accuracy, comparability, carryover, background and linearity throughout the expected range of results. Yet, which standard should be met or which verification limit be used is at the discretion of the laboratory specialist. This paper offers practical guidance on verification and quality control of automated hematology analyzers and provides an expert opinion on the performance standard that should be met by the contemporary generation of hematology analyzers. Therefore (i) the state-of-the-art performance of hematology analyzers for complete blood count parameters is summarized, (ii) considerations, challenges, and pitfalls concerning the development of a verification plan are discussed, (iii) guidance is given regarding the establishment of reference intervals, and (iv) different methods on quality control of hematology analyzers are reviewed.


Assuntos
Hematologia/instrumentação , Controle de Qualidade , Automação , Contagem de Células Sanguíneas , Hematologia/normas , Humanos , Guias de Prática Clínica como Assunto
4.
BJOG ; 123(12): 1965-1971, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26667313

RESUMO

OBJECTIVE: To evaluate whether in symptomatic women, the combination of quantitative fetal fibronectin (fFN) testing and cervical length (CL) improves the prediction of preterm delivery (PTD) within 7 days compared with qualitative fFN and CL. DESIGN: Post hoc analysis of frozen fFN samples of a nationwide cohort study. SETTING: Ten perinatal centres in the Netherlands. POPULATION: Symptomatic women between 24 and 34 weeks of gestation. METHODS: The risk of PTD <7 days was estimated in predefined CL and fFN strata. We used logistic regression to develop a model including quantitative fFN and CL, and one including qualitative fFN (threshold 50 ng/ml) and CL. We compared the models' capacity to identify women at low risk (<5%) for delivery within 7 days using a reclassification table. MAIN OUTCOME MEASURES: Spontaneous delivery within 7 days after study entry. RESULTS: We studied 350 women, of whom 69 (20%) delivered within 7 days. The risk of PTD in <7 days ranged from 2% in the lowest fFN group (<10 ng/ml) to 71% in the highest group (>500 ng/ml). Multivariable logistic regression showed an increasing risk of PTD in <7 days with rising fFN concentration [10-49 ng/ml: odds ratio (OR) 1.3, 95% confidence interval (95% CI) 0.23-7.0; 50-199 ng/ml: OR 3.2, 95% CI 0.79-13; 200-499 ng/ml: OR 9.0, 95% CI 2.3-35; >500 ng/ml: OR 39, 95% CI 9.4-164] and shortening of the CL (OR 0.86 per mm, 95% CI 0.82-0.90). Use of quantitative fFN instead of qualitative fFN resulted in reclassification of 18 (5%) women from high to low risk, of whom one (6%) woman delivered within 7 days. CONCLUSION: In symptomatic women, quantitative fFN testing does not improve the prediction of PTD within 7 days compared with qualitative fFN testing in combination with CL measurement in terms of reclassification from high to low (<5%) risk, but it adds value across the risk range. TWEETABLE ABSTRACT: Quantitative fFN testing adds value to qualitative fFN testing with CL measurement in the prediction of PTD.


Assuntos
Medida do Comprimento Cervical , Fibronectinas , Colo do Útero/química , Estudos de Coortes , Feminino , Humanos , Recém-Nascido , Trabalho de Parto Prematuro , Valor Preditivo dos Testes , Nascimento Prematuro
5.
Ultrasound Obstet Gynecol ; 40(6): 636-41, 2012 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-22374827

RESUMO

OBJECTIVE: To assess the association between first-trimester crown-rump length (CRL) and the risk of spontaneous preterm birth before 32 weeks' gestation. METHODS: We performed a matched case-control study of 129 women with spontaneous preterm birth at < 32 weeks' gestation (cases) and 129 women with term deliveries (controls) using data stored in the ultrasound and obstetric databases of our tertiary referral center. Cases and controls were individually matched based on maternal age, parity, history of preterm birth and medical indication for antenatal care. Fetal CRL measured between 8 + 0 and 13 + 6 weeks was expressed as multiples of the median (MoM) expected CRL, based on last menstrual period. We investigated the association between CRL-MoM and spontaneous preterm birth using logistic regression analysis. RESULTS: CRL-MoM was not associated with spontaneous preterm birth: odds ratio (OR) 1.10 (95% CI, 0.89-1.36) per 0.10 MoM increase in CRL. Timing of measurement did not influence the model (P = 0.59). This was confirmed when restricting the analysis to the 93 pairs with CRL measurements made between 10 + 0 and 13 + 6 weeks: OR for preterm birth 1.07 (95% CI, 0.83-1.37) per 0.10 MoM increase in CRL. CONCLUSION: A short CRL in the first trimester is not associated with spontaneous preterm birth before 32 weeks' gestation, thus short CRL cannot be used to identify women at increased risk of preterm birth.


Assuntos
Estatura Cabeça-Cóccix , Nascimento Prematuro/etiologia , Adulto , Estudos de Casos e Controles , Feminino , Idade Gestacional , Humanos , Idade Materna , Gravidez , Primeiro Trimestre da Gravidez , Ultrassonografia Pré-Natal
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA