Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
Curr Probl Diagn Radiol ; 53(1): 96-101, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-37914652

RESUMO

RATIONALE AND OBJECTIVES: Communication with and within the Radiology Department is typically initiated over phone, face-to-face or general-purpose chat, causing frequent interruptions, additional mental workload, workflow inefficiencies and diagnostic errors. We developed and evaluated a new communication solution that aims to reduce avoidable interruptions caused by technologist-radiologist communication. MATERIALS AND METHODS: Following an iterative design process with future end users, a scalable web-based software solution, RadConnect, was developed enabling a chat-based communication workflow between a technologist and a radiologist. As a first experimental implementation, technologists can send categorized tickets to a radiology section account. Radiologists receive the tickets in a worklist that is prioritized by urgency. Consented radiologists and technologists performed scripted tasks in 2 hr sessions and completed a structured questionnaire on perceived value and comparison to standard communication modes. RESULTS: Of 17 participants from three academic European institutes, 65% (11/17) believed they would use RadConnect frequently; 53% (9/17) believed that it reduces phone calls >80%; and 88% (15/17) believed it adds value compared to general-purpose enterprise chat applications. DISCUSSION: Participants recognized the value of RadConnect especially its categorized tickets, prioritized worklist and role-based interaction model. Inter-institute differences in perceived value of RadConnect may have been caused by technologist-radiologist proximity and communication alternatives in the institutions. CONCLUSION: Chat-based role-based communication might be a viable mode of communication between technologists and radiologists to reduce avoidable interruptions. Tailoring the chat solution to the needs of and tightly integrated with the radiology workflow is valued by future end users after exposure to the tool in a simulated environment.


Assuntos
Radiologia , Humanos , Radiografia , Radiologistas , Carga de Trabalho , Comunicação
2.
Diagn Interv Imaging ; 104(5): 243-247, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36681532

RESUMO

PURPOSE: The purpose of this study was to develop a method for generating synthetic MR images of macrotrabecular-massive hepatocellular carcinoma (MTM-HCC). MATERIALS AND METHODS: A set of abdominal MR images including fat-saturated T1-weighted images obtained during the arterial and portal venous phases of enhancement and T2-weighted images of 91 patients with MTM-HCC, and another set of MR abdominal images from 67 other patients were used. Synthetic images were obtained using a 3-step pipeline that consisted in: (i), generating a synthetic MTM-HCC tumor on a neutral background; (ii), randomly selecting a background among the 67 patients and a position inside the liver; and (iii), merging the generated tumor in the background at the specified location. Synthetic images were qualitatively evaluated by three radiologists and quantitatively assessed using a mix of 1-nearest neighbor classifier metric and Fréchet inception distance. RESULTS: A set of 1000 triplets of synthetic MTM-HCC images with consistent contrasts were successfully generated. Evaluation of selected synthetic images by three radiologists showed that the method gave realistic, consistent and diversified images. Qualitative and quantitative evaluation led to an overall score of 0.64. CONCLUSION: This study shows the feasibility of generating realistic synthetic MR images with very few training data, by leveraging the wide availability of liver backgrounds. Further studies are needed to assess the added value of those synthetic images for automatic diagnosis of MTM-HCC.


Assuntos
Carcinoma Hepatocelular , Neoplasias Hepáticas , Humanos , Carcinoma Hepatocelular/diagnóstico por imagem , Carcinoma Hepatocelular/patologia , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/patologia , Imageamento por Ressonância Magnética/métodos , Meios de Contraste
3.
Eur Radiol ; 32(7): 4780-4790, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35142898

RESUMO

OBJECTIVE: This study aimed to develop and investigate the performance of a deep learning model based on a convolutional neural network (CNN) for the automatic segmentation of polycystic livers at CT imaging. METHOD: This retrospective study used CT images of polycystic livers. To develop the CNN, supervised training and validation phases were performed using 190 CT series. To assess performance, the test phase was performed using 41 CT series. Manual segmentation by an expert radiologist (Rad1a) served as reference for all comparisons. Intra-observer variability was determined by the same reader after 12 weeks (Rad1b), and inter-observer variability by a second reader (Rad2). The Dice similarity coefficient (DSC) evaluated overlap between segmentations. CNN performance was assessed using the concordance correlation coefficient (CCC) and the two-by-two difference between the CCCs; their confidence interval was estimated with bootstrap and Bland-Altman analyses. Liver segmentation time was automatically recorded for each method. RESULTS: A total of 231 series from 129 CT examinations on 88 consecutive patients were collected. For the CNN, the DSC was 0.95 ± 0.03 and volume analyses yielded a CCC of 0.995 compared with reference. No statistical difference was observed in the CCC between CNN automatic segmentation and manual segmentations performed to evaluate inter-observer and intra-observer variability. While manual segmentation required 22.4 ± 10.4 min, central and graphics processing units took an average of 5.0 ± 2.1 s and 2.0 ± 1.4 s, respectively. CONCLUSION: Compared with manual segmentation, automated segmentation of polycystic livers using a deep learning method achieved much faster segmentation with similar performance. KEY POINTS: • Automatic volumetry of polycystic livers using artificial intelligence method allows much faster segmentation than expert manual segmentation with similar performance. • No statistical difference was observed between automatic segmentation, inter-observer variability, or intra-observer variability.


Assuntos
Aprendizado Profundo , Inteligência Artificial , Humanos , Processamento de Imagem Assistida por Computador/métodos , Fígado/diagnóstico por imagem , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos
4.
Eur Radiol ; 32(5): 3248-3259, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-35001157

RESUMO

OBJECTIVE: To train and to test for prostate zonal segmentation an existing algorithm already trained for whole-gland segmentation. METHODS: The algorithm, combining model-based and deep learning-based approaches, was trained for zonal segmentation using the NCI-ISBI-2013 dataset and 70 T2-weighted datasets acquired at an academic centre. Test datasets were randomly selected among examinations performed at this centre on one of two scanners (General Electric, 1.5 T; Philips, 3 T) not used for training. Automated segmentations were corrected by two independent radiologists. When segmentation was initiated outside the prostate, images were cropped and segmentation repeated. Factors influencing the algorithm's mean Dice similarity coefficient (DSC) and its precision were assessed using beta regression. RESULTS: Eighty-two test datasets were selected; one was excluded. In 13/81 datasets, segmentation started outside the prostate, but zonal segmentation was possible after image cropping. Depending on the radiologist chosen as reference, algorithm's median DSCs were 96.4/97.4%, 91.8/93.0% and 79.9/89.6% for whole-gland, central gland and anterior fibromuscular stroma (AFMS) segmentations, respectively. DSCs comparing radiologists' delineations were 95.8%, 93.6% and 81.7%, respectively. For all segmentation tasks, the scanner used for imaging significantly influenced the mean DSC and its precision, and the mean DSC was significantly lower in cases with initial segmentation outside the prostate. For central gland segmentation, the mean DSC was also significantly lower in larger prostates. The radiologist chosen as reference had no significant impact, except for AFMS segmentation. CONCLUSIONS: The algorithm performance fell within the range of inter-reader variability but remained significantly impacted by the scanner used for imaging. KEY POINTS: • Median Dice similarity coefficients obtained by the algorithm fell within human inter-reader variability for the three segmentation tasks (whole gland, central gland, anterior fibromuscular stroma). • The scanner used for imaging significantly impacted the performance of the automated segmentation for the three segmentation tasks. • The performance of the automated segmentation of the anterior fibromuscular stroma was highly variable across patients and showed also high variability across the two radiologists.


Assuntos
Aprendizado Profundo , Próstata , Algoritmos , Humanos , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Masculino , Pelve , Próstata/diagnóstico por imagem
5.
Eur Radiol ; 32(6): 4292-4303, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35029730

RESUMO

OBJECTIVES: To compare the lung CT volume (CTvol) and pulmonary function tests in an interstitial lung disease (ILD) population. Then to evaluate the CTvol loss between idiopathic pulmonary fibrosis (IPF) and non-IPF and explore a prognostic value of annual CTvol loss in IPF. METHODS: We conducted in an expert center a retrospective study between 2005 and 2018 on consecutive patients with ILD. CTvol was measured automatically using commercial software based on a deep learning algorithm. In the first group, Spearman correlation coefficients (r) between forced vital capacity (FVC), total lung capacity (TLC), and CTvol were calculated. In a second group, annual CTvol loss was calculated using linear regression analysis and compared with the Mann-Whitney test. In a last group of IPF patients, annual CTvol loss was calculated between baseline and 1-year CTs for investigating with the Youden index a prognostic value of major adverse event at 3 years. Univariate and log-rank tests were calculated. RESULTS: In total, 560 patients (4610 CTs) were analyzed. For 1171 CTs, CTvol was correlated with FVC (r: 0.86) and TLC (r: 0.84) (p < 0.0001). In 408 patients (3332 CT), median annual CTvol loss was 155.7 mL in IPF versus 50.7 mL in non-IPF (p < 0.0001) over 5.03 years. In 73 IPF patients, a relative annual CTvol loss of 7.9% was associated with major adverse events (log-rank, p < 0.0001) in univariate analysis (p < 0.001). CONCLUSIONS: Automated lung CT volume may be an alternative or a complementary biomarker to pulmonary function tests for the assessment of lung volume loss in ILD. KEY POINTS: • There is a good correlation between lung CT volume and forced vital capacity, as well as for with total lung capacity measurements (r of 0.86 and 0.84 respectively, p < 0.0001). • Median annual CT volume loss is significantly higher in patients with idiopathic pulmonary fibrosis than in patients with other fibrotic interstitial lung diseases (155.7 versus 50.7 mL, p < 0.0001). • In idiopathic pulmonary fibrosis, a relative annual CT volume loss higher than 9.4% is associated with a significantly reduced mean survival time at 2.0 years versus 2.8 years (log-rank, p < 0.0001).


Assuntos
Fibrose Pulmonar Idiopática , Doenças Pulmonares Intersticiais , Humanos , Fibrose Pulmonar Idiopática/diagnóstico por imagem , Pulmão/diagnóstico por imagem , Doenças Pulmonares Intersticiais/diagnóstico por imagem , Medidas de Volume Pulmonar , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos , Capacidade Vital
6.
Med Phys ; 49(2): 1108-1122, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34689353

RESUMO

PURPOSE: In computed tomography (CT) cardiovascular imaging, the numerous contrast injection protocols used to enhance structures make it difficult to gather training datasets for deep learning applications supporting diverse protocols. Moreover, creating annotations on noncontrast scans is extremely tedious. Recently, spectral CT's virtual-noncontrast images (VNC) have been used as data augmentation to train segmentation networks performing on enhanced and true-noncontrast (TNC) scans alike, while improving results on protocols absent of their training dataset. However, spectral data are not widely available, making it difficult to gather specific datasets for each task. As a solution, we present a data augmentation workflow based on a trained image translation network, to bring spectral-like augmentation to any conventional CT dataset. METHOD: The conventional CT-to-spectral image translation network (HUSpectNet) was first trained to generate VNC from conventional housnfied units images (HU), using an unannotated spectral dataset of 1830 patients. It was then tested on a second dataset of 300 spectral CT scans by comparing VNC generated through deep learning (VNCDL ) to their true counterparts. To illustrate and compare our workflow's efficiency with true spectral augmentation, HUSpectNet was applied to a third dataset of 112 spectral scans to generate VNCDL along HU and VNC images. Three different three-dimensional (3D) networks (U-Net, X-Net, and U-Net++) were trained for multilabel heart segmentation, following four augmentation strategies. As baselines, trainings were performed on contrasted images without (HUonly) and with conventional gray-values augmentation (HUaug). Then, the same networks were trained using a proportion of contrasted and VNC/VNCDL images (TrueSpec/GenSpec). Each training strategy applied to each architecture was evaluated using Dice coefficients on a fourth multicentric multivendor single-energy CT dataset of 121 patients, including different contrast injection protocols and unenhanced scans. The U-Net++ results were further explored with distance metrics on every label. RESULTS: Tested on 300 full scans, our HUSpectNet translation network shows a mean absolute error of 6.70 ± 2.83 HU between VNCDL and VNC, while peak signal-to-noise ratio reaches 43.89 dB. GenSpec and TrueSpec show very close results regardless of the protocol and used architecture: mean Dice coefficients (DSCmean ) are equal with a margin of 0.006, ranging from 0.879 to 0.938. Their performances significantly increase on TNC scans (p-values < 0.017 for all architectures) compared to HUonly and HUaug, with DSCmean of 0.448/0.770/0.879/0.885 for HUonly/HUaug/TrueSpec/GenSpec using the U-Net++ architecture. Significant improvements are also noted for all architectures on chest-abdominal-pelvic scans (p-values < 0.007) compared to HUonly and for pulmonary embolism scans (p-values < 0.039) compared to HUaug. Using U-Net++, DSCmean reaches 0.892/0.901/0.903 for HUonly/TrueSpec/GenSpec on pulmonary embolism scans and 0.872/0.896/0.896 for HUonly/TrueSpec/GenSpec on chest-abdominal-pelvic scans. CONCLUSION: Using the proposed workflow, we trained versatile heart segmentation networks on a dataset of conventional enhanced CT scans, providing robust predictions on both enhanced scans with different contrast injection protocols and TNC scans. The performances obtained were not significantly inferior to training the model on a genuine spectral CT dataset, regardless of the architecture implemented. Using a general-purpose conventional-to-spectral CT translation network as data augmentation could therefore contribute to reducing data collection and annotation requirements for machine learning-based CT studies, while extending their range of application.


Assuntos
Tórax , Tomografia Computadorizada por Raios X , Coração/diagnóstico por imagem , Humanos , Processamento de Imagem Assistida por Computador , Razão Sinal-Ruído , Fluxo de Trabalho
7.
Res Diagn Interv Imaging ; 4: 100018, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37284031

RESUMO

Objectives: We evaluated the contribution of lung lesion quantification on chest CT using a clinical Artificial Intelligence (AI) software in predicting death and intensive care units (ICU) admission for COVID-19 patients. Methods: For 349 patients with positive COVID-19-PCR test that underwent a chest CT scan at admittance or during hospitalization, we applied the AI for lung and lung lesion segmentation to obtain lesion volume (LV), and LV/Total Lung Volume (TLV) ratio. ROC analysis was used to extract the best CT criterion in predicting death and ICU admission. Two prognostic models using multivariate logistic regressions were constructed to predict each outcome and were compared using AUC values. The first model ("Clinical") was based on patients' characteristics and clinical symptoms only. The second model ("Clinical+LV/TLV") included also the best CT criterion. Results: LV/TLV ratio demonstrated best performance for both outcomes; AUC of 67.8% (95% CI: 59.5 - 76.1) and 81.1% (95% CI: 75.7 - 86.5) respectively. Regarding death prediction, AUC values were 76.2% (95% CI: 69.9 - 82.6) and 79.9% (95%IC: 74.4 - 85.5) for the "Clinical" and the "Clinical+LV/TLV" models respectively, showing significant performance increase (+ 3.7%; p-value<0.001) when adding LV/TLV ratio. Similarly, for ICU admission prediction, AUC values were 74.9% (IC 95%: 69.2 - 80.6) and 84.8% (IC 95%: 80.4 - 89.2) respectively corresponding to significant performance increase (+ 10%: p-value<0.001). Conclusions: Using a clinical AI software to quantify the COVID-19 lung involvement on chest CT, combined with clinical variables, allows better prediction of death and ICU admission.

8.
Int J Comput Assist Radiol Surg ; 16(10): 1699-1709, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34363582

RESUMO

PURPOSE: Recently, machine learning has outperformed established tools for automated segmentation in medical imaging. However, segmentation of cardiac chambers still proves challenging due to the variety of contrast agent injection protocols used in clinical practice, inducing disparities of contrast between cavities. Hence, training a generalist network requires large training datasets representative of these protocols. Furthermore, segmentation on unenhanced CT scans is further hindered by the challenge of obtaining ground truths from these images. Newly available spectral CT scanners allow innovative image reconstructions such as virtual non-contrast (VNC) imaging, mimicking non-contrasted conventional CT studies from a contrasted scan. Recent publications have demonstrated that networks can be trained using VNC to segment contrasted and unenhanced conventional CT scans to reduce annotated data requirements and the need for annotations on unenhanced scans. We propose an extensive evaluation of this statement. METHOD: We undertake multiple trainings of a 3D multi-label heart segmentation network with (HU-VNC) and without (HUonly) VNC as augmentation, using decreasing training dataset sizes (114, 76, 57, 38, 29, 19 patients). At each step, both networks are tested on a multi-vendor, multi-centric dataset of 122 patients, including different protocols: pulmonary embolism (PE), chest-abdomen-pelvis (CAP), heart CT angiography (CTA) and true non-contrast scans (TNC). An in-depth comparison of resulting Dice coefficients and distance metrics is performed for the networks trained on the largest dataset. RESULTS: HU-VNC-trained on 57 patients significantly outperforms HUonly trained on 114 regarding CAP and TNC scans (mean Dice coefficients of 0.881/0.835 and 0.882/0.416, respectively). When trained on the largest dataset, significant improvements in all labels are noted for TNC and CAP scans (mean Dice coefficient of 0.882/0.416 and 0.891/0.835, respectively). CONCLUSION: Adding VNC images as training augmentation allows the network to perform on unenhanced scans and improves segmentations on other imaging protocols, while using a reduced training dataset.


Assuntos
Processamento de Imagem Assistida por Computador , Tomografia Computadorizada por Raios X , Angiografia por Tomografia Computadorizada , Coração , Humanos , Tórax
9.
Eur Radiol ; 31(2): 795-803, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-32813105

RESUMO

OBJECTIVES: To assess the diagnostic performances of chest CT for triage of patients in multiple emergency departments during COVID-19 epidemic, in comparison with reverse transcription polymerase chain reaction (RT-PCR) test. METHOD: From March 3 to April 4, 2020, 694 consecutive patients from three emergency departments of a large university hospital, for which a hospitalization was planned whatever the reasons, i.e., COVID- or non-COVID-related, underwent a chest CT and one or several RT-PCR tests. Chest CTs were rated as "Surely COVID+," "Possible COVID+," or "COVID-" by experienced radiologists. Sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were calculated using the final RT-PCR test as standard of reference. The delays for CT reports and RT-PCR results were recorded and compared. RESULTS: Among the 694 patients, 287 were positive on the final RT-PCR exam. Concerning the 694 chest CT, 308 were rated as "Surely COVID+", 34 as "Possible COVID+," and 352 as "COVID-." When considering only the "Surely COVID+" CT as positive, accuracy, sensitivity, specificity, PPV, and NPV reached 88.9%, 90.2%, 88%, 84.1%, and 92.7%, respectively, with respect to final RT-PCR test. The mean delay for CT reports was three times shorter than for RT-PCR results (187 ± 148 min versus 573 ± 327 min, p < 0.0001). CONCLUSION: During COVID-19 epidemic phase, chest CT is a rapid and most probably an adequately reliable tool to refer patients requiring hospitalization to the COVID+ or COVID- hospital units, when response times for virological tests are too long. KEY POINTS: • In a large university hospital in Lyon, France, the accuracy, sensitivity, specificity, PPV, and NPV of chest CT for COVID-19 reached 88.9%, 90.2%, 88%, 84.1%, and 92.7%, respectively, using RT-PCR as standard of reference. • The mean delay for CT reports was three times shorter than for RT-PCR results (187 ± 148 min versus 573 ± 327 min, p < 0.0001). • Due to high accuracy of chest CT for COVID-19 and shorter time for CT reports than RT-PCR results, chest CT can be used to orient patients suspected to be positive towards the COVID+ unit to decrease congestion in the emergency departments.


Assuntos
COVID-19/diagnóstico por imagem , Triagem , Idoso , Idoso de 80 Anos ou mais , COVID-19/epidemiologia , Serviço Hospitalar de Emergência , Epidemias , Feminino , França , Hospitais Universitários , Humanos , Masculino , Valor Preditivo dos Testes , SARS-CoV-2 , Fatores de Tempo , Tomografia Computadorizada por Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA