Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
PLoS One ; 11(9): e0162879, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27657729

RESUMO

INTRODUCTION: Objective of our study was to determine the agreement between version 1 (v1) and v2 of the Prostate Imaging Reporting and Data System (PI-RADS) for evaluation of multiparametric prostate MRI (mpMRI) and to compare their diagnostic accuracy, their inter-observer agreement and practicability. MATERIAL AND METHODS: mpMRI including T2-weighted imaging, diffusion-weighted imaging (DWI) and dynamic contrast-enhanced imaging (DCE) of 54 consecutive patients, who subsequently underwent MRI-guided in-bore biopsy were re-analyzed according to PI-RADS v1 and v2 by two independent readers. Diagnostic accuracy for detection of prostate cancer (PCa) was assessed using ROC-curve analysis. Agreement between PI-RADS versions and observers was calculated and the time needed for scoring was determined. RESULTS: MRI-guided biopsy revealed PCa in 31 patients. Diagnostic accuracy for detection of PCa was equivalent with both PI-RADS versions for reader 1 with sensitivities and specificities of 84%/91% (AUC = 0.91 95%CI[0.8-1]) for PI-RADS v1 and 100%/74% (AUC = 0.92 95% CI[0.8-1]) for PI-RADS v2. Reader 2 achieved similar diagnostic accuracy with sensitivity and specificity of 74%/91% (AUC = 0.88 95%CI[0.8-1]) for PI-RADS v1 and 81%/91% (AUC = 0.91 95%CI[0.8-1]) for PI-RADS v2. Agreement between scores determined with different PI-RADS versions was good (reader 1: κ = 0.62, reader 2: κ = 0.64). Inter-observer agreement was moderate with PI-RADS v2 (κ = 0.56) and fair with v1 (κ = 0.39). The time required for building the PI-RADS score was significantly lower with PI-RADS v2 compared to v1 (24.7±2.3 s vs. 41.9±2.6 s, p<0.001). CONCLUSION: Agreement between PI-RADS versions was high and both versions revealed high diagnostic accuracy for detection of PCa. Due to better inter-observer agreement for malignant lesions and less time demand, the new PI-RADS version could be more practicable for clinical routine.

2.
J Vasc Interv Radiol ; 14(1): 41-51, 2003 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-12525585

RESUMO

PURPOSE: To report a prospective study to evaluate safety, effectiveness, and midterm patency of self-expanding stent-grafts in patients with femoropopliteal occlusive disease. MATERIALS AND METHODS: Sixty-three Hemobahn stent-grafts were used in 52 patients for treatment of medium- or long-segment (>3 cm) occlusions (82.7%) and stenoses (17.3%) of the femoropopliteal artery. The mean length of vessel segments covered was 10.9 cm +/- 5.13. Follow-up with documentation of clinical symptoms, assessment of Rutherford clinical stage of peripheral vascular disease, and color-coded duplex sonography was performed at discharge, at 1, 3, 6, 12, 18, and 24 months after implantation, and yearly thereafter. Mean follow-up duration was 23.8 months +/- 6.9 (range, 8-36 mo). Follow-up data at 12 and 24 months after treatment were available for 47 of 52 (90.4%) and 31 of 52 patients (59.6%), respectively. RESULTS: Device implantation was technically successful in all 52 patients, yielding an overall technical success rate of 100%. Procedure-related complications were observed in 12 of 52 patients (23.1%) and consisted of distal embolization (n = 4, 7.7%), minor groin hematoma (n = 7, 13.5%), and arteriovenous fistula (n = 1, 1.9%), but prolonged hospitalization and further medical, interventional, or surgical measures were not required. Stent-graft placement induced an initial improvement of the mean resting ankle-brachial index from 0.54 +/- 0.12 to 0.89 +/- 0.14 (P <.01). Primary patency rates at 12 and 24 months were 78.4% +/- 5.8 and 74.1% +/- 6.2, respectively. Primary assisted patency rates were 82.4% +/- 5.3 at 12 months and 80.3% +/- 5.6 at 24 months. Secondary patency rates at 12 and 24 months were 88.3% +/- 4.5 and 83.2% +/- 5.5, respectively. There was no significant difference (log-rank test, P >.3) between primary patency rates in patients grouped according to lengths of implanted grafts (ie, length of the treated lesions). CONCLUSION: Endovascular placement of Hemobahn stent-grafts for percutaneous treatment of medium- to long-segment high-grade stenoses and occlusions of the femoropopliteal artery is a safe procedure with excellent initial success rates and promising midterm results.


Assuntos
Arteriopatias Oclusivas/terapia , Implante de Prótese Vascular/métodos , Artéria Femoral , Claudicação Intermitente/terapia , Artéria Poplítea , Stents , Idoso , Idoso de 80 Anos ou mais , Angiografia Digital , Angioplastia com Balão , Arteriopatias Oclusivas/complicações , Arteriopatias Oclusivas/diagnóstico por imagem , Feminino , Artéria Femoral/cirurgia , Humanos , Claudicação Intermitente/etiologia , Masculino , Pessoa de Meia-Idade , Artéria Poplítea/cirurgia , Estudos Prospectivos , Resultado do Tratamento , Grau de Desobstrução Vascular
3.
J Vasc Interv Radiol ; 13(3): 257-66, 2002 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-11875085

RESUMO

PURPOSE: To report on a prospective two-center study to evaluate safety and effectiveness of a self-expanding nitinol coil stent in patients with femoropopliteal obstructive disease. MATERIALS AND METHODS: The IntraCoil nitinol stent was used in 37 patients (28 men and nine women; mean age, 62.4 y plus minus 10.7; range, 43-81 y) presenting with high-grade stenoses (n = 23) or short (<3 cm) occlusions (n = 17) of the superficial femoral artery (SFA; n = 33) or popliteal artery (n = 4). Indications for stent placement were significant residual stenosis (>30%) or dissection after angioplasty. Follow-up evaluations with measurement of the Doppler ankle-brachial index (ABI), assessment of Rutherford clinical stage, and color-coded duplex sonography were performed at discharge and 1, 3, 6, 12, and 18 months thereafter. Primary endpoints of the study were immediate technical and clinical success and 1-year patency. RESULTS: Initial technical success was achieved in all patients. In 10 patients (27%), more than one 40-mm-long device had to be implanted for total lesion coverage; in three patients (8.1%), stents were placed in two separate segments of the SFA simultaneously. The total number of stents deployed was 50. Stent placement induced an initial improvement of the ABI from 0.54 plus minus 0.2 to 0.92 plus minus 0.11 (P <.01). Follow-up data for 12 months after treatment are available for 29 of 37 patients (78.4%); mean follow-up is 15.6 months (range, 1-26 mo). Primary patency rates at 6 and 12 months were 97.1% (SE = 2.9) and 86.2% (SE = 6.5). The primary assisted patency rate was 100% at 12 months. CONCLUSION: Endovascular placement of the IntraCoil self-expanding nitinol coil stent for salvage of failed angioplasty in patients with femoropopliteal obstructive disease is an effective and safe procedure with promising mid-term results.


Assuntos
Arteriopatias Oclusivas/terapia , Artéria Femoral , Doenças Vasculares Periféricas/terapia , Artéria Poplítea , Stents/efeitos adversos , Adulto , Idoso , Idoso de 80 Anos ou mais , Ligas , Angioplastia com Balão/efeitos adversos , Constrição Patológica/terapia , Feminino , Humanos , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Seleção de Pacientes , Segurança , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA