RESUMO
OBJECTIVE: To investigate the feasibility of fluorescence molecular imaging (FMI), using cetuximab-800CW, as an intraoperative tool to determine surgical margins in penile squamous cell carcinoma (PSCC). PATIENTS AND METHODS: A total of 11 patients with PSCC received 75 mg cetuximab followed by 15 mg cetuximab-800CW 2 days before surgery. FMI of the whole excision specimen and tissue slices was performed. Fluorescence visualisation was correlated to histopathology. Based on tumour and healthy tissue regions of interest, mean fluorescence intensity was calculated for each individual patient. RESULTS: Significant differences between tumour and healthy mean fluorescence intensity were found with tumour-to-background ratios of a median (IQR) of 1.51 (0.99) and a mean (SD) of 1.51 (0.32) in the excision specimen and tissue slices, respectively. One patient showed a high relative fluorescence intensity with a signal-to-background ratio of 1.79, corresponding to a tumour-positive margin on fresh frozen sectioning. CONCLUSION: In this Phase I study we showed that cetuximab-800CW seems suitable to discriminate PSCC from background tissue. The tracer was well tolerated, and no false positive spots were seen.
Assuntos
Antineoplásicos Imunológicos , Carcinoma de Células Escamosas , Cetuximab , Neoplasias Penianas , Humanos , Masculino , Cetuximab/administração & dosagem , Neoplasias Penianas/cirurgia , Neoplasias Penianas/patologia , Neoplasias Penianas/tratamento farmacológico , Pessoa de Meia-Idade , Idoso , Carcinoma de Células Escamosas/cirurgia , Carcinoma de Células Escamosas/patologia , Carcinoma de Células Escamosas/tratamento farmacológico , Antineoplásicos Imunológicos/uso terapêutico , Antineoplásicos Imunológicos/administração & dosagem , Estudos de Viabilidade , Cirurgia Assistida por Computador/métodos , Imagem Óptica/métodos , Margens de ExcisãoRESUMO
Significance: Surgical excision is the main treatment for solid tumors in oral squamous cell carcinomas, where wide local excision (achieving a healthy tissue margin of >5 mm around the excised tumor) is the goal as it results in reduced local recurrence rates and improved overall survival. Aim: No clinical methods are available to assess the complete surgical margin intraoperatively while the patient is still on the operating table; and while recent intraoperative back-bench fluorescence-guided surgery approaches have shown promise for detecting "positive" inadequate margins (<1 mm), they have had limited success in the detection of "close" inadequate margins (1 to 5 mm). Here, a dual aperture fluorescence ratio (dAFR) approach was evaluated as a means of improving detection of close margins. Approach: The approach was evaluated on surgical specimens from patients who were administered a tumor-specific fluorescent imaging agent (cetuximab-800CW) prior to surgery. The dAFR approach was compared directly against standard wide-field fluorescence imaging and pathology measurements of margin thickness in specimens from three patients and a total of 12 margin locations (1 positive, 5 close, and 6 clear margins). Results: The area under the receiver operating characteristic curve, representing the ability to detect close compared to clear margins (>5 mm) was found to be 1.0 and 0.57 for dAFR and sAF, respectively. Improvements in dAFR were found to be statistically significant (p<0.02). Conclusions: These results provide evidence that the dAFR approach potentially improves detection of close surgical margins.