Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Pharm Dev Technol ; 28(8): 724-742, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37493413

RESUMO

In the present study, novel gastroretentive bilayer tablets were developed that are promising for the once-a-day oral delivery of the drug candidate MT-1207. The gastroretentive layer consisted of a combination of hydrophilic and hydrophobic polymers, namely polyethylene oxide and Kollidon® SR. A factorial experiment was conducted, and the results revealed a non-effervescent gastroretentive layer that, unlike most gastroretentive layers reported in the literature, was easy to prepare, and provided immediate tablet buoyancy (mean floating lag time of 1.5 s) that lasted over 24 h in fasted state simulated gastric fluid (FaSSGF) pH 1.6, irrespective of the drug layer, thereby allowing a 24-hour sustained release of MT-1207 from the drug layer of the tablets. Furthermore, during in vitro buoyancy testing of the optimised bilayer tablets in media of different pH values (1.0, 3.0, 6.0), the significant difference (one-way ANOVA, p < 0.001) between the respective total floating times indicated that stomach pH effects on tablet buoyancy are important to be considered during the development of non-effervescent gastroretentive formulations and the choice of dosing regimen. To the best of our knowledge, this has not been reported before, and it should probably be factored in when designing dosing regimens. Finally, a pharmacokinetic study in Beagle dogs indicated a successful in vivo 24-hour sustained release of MT-1207 from the optimised gastroretentive bilayer tablet formulations with the drug plasma concentration remaining above the estimated minimum effective concentration of 1 ng/mL at the 24-hour timepoint and also demonstrated the gastroretentive capabilities of the hydrophilic and hydrophobic polymer combination. The optimised formulations will be forwarded to clinical development.


Assuntos
Polímeros , Animais , Cães , Preparações de Ação Retardada/química , Polímeros/química , Solubilidade , Comprimidos/química
2.
Pharmaceutics ; 13(10)2021 Sep 30.
Artigo em Inglês | MEDLINE | ID: mdl-34683884

RESUMO

There have been many efforts to improve oral drug bioavailability and therapeutic efficacy and patient compliance. A variety of controlled-release oral delivery systems have been developed to meet these needs. Gastroretentive drug delivery technologies have the potential to achieve retention of the dosage form in the upper gastrointestinal tract (GIT) that can be sufficient to ensure complete solubilisation of the drugs in the stomach fluids, followed by subsequent absorption in the stomach or proximal small intestine. This can be beneficial for drugs that have an "absorption window" or are absorbed to a different extent in various segments of the GIT. Therefore, gastroretentive technologies in tandem with controlled-release strategies could enhance both the therapeutic efficacy of many drugs and improve patient compliance through a reduction in dosing frequency. The paper reviews different gastroretentive drug delivery technologies and controlled-release strategies that can be combined and summarises examples of formulations currently in clinical development and commercially available gastroretentive controlled-release products. The different parameters that need to be considered and monitored during formulation development for these pharmaceutical applications are highlighted.

3.
Pharm Dev Technol ; 26(3): 349-361, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33430679

RESUMO

Hypertension is one of the most common chronic cardiovascular disorders. Sustained-release formulations are developed to maintain drug therapeutic levels throughout the treatment of hypertension, to promote patient compliance and improve patient outcomes. We have developed and tested in in vivo trials a once-a-day tablet formulation for the novel antihypertensive drug MT-1207. The tablets based upon a hydrophilic polymer matrix underwent post-compression parameter and physicochemical characterisations, along with in vitro drug release testing. The most promising formulation containing 31% w/w HPMC K15M gave a 24-hour release of MT-1207 with an almost constant release rate up to 20 hours. Follow in in vivo studies were carried out in Beagle dogs for the optimised sustained-release tablets in comparison to immediate-release tablets. The results showed that a sustained release of MT-1207 from the new formulation was achieved with a drug t1/2 2-2.5 times longer than the immediate-release tablets. Moreover, the AUC0-24h values of both sustained- and immediate-release tablets were identical at the same dose of 30 mg, indicating that the same amount of drug was absorbed in each case. For treatments based upon MT-1207, this development is significant for future commercial exploitation via scale-up and further trials, and for improved patient outcomes.


Assuntos
Anti-Hipertensivos/administração & dosagem , Preparações de Ação Retardada/química , Animais , Anti-Hipertensivos/sangue , Cães , Liberação Controlada de Fármacos , Feminino , Derivados da Hipromelose/química , Masculino , Solubilidade , Comprimidos
4.
Eur J Pharm Biopharm ; 156: 40-49, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-32882421

RESUMO

During the OrBiTo project, our knowledge on the gastrointestinal environment has improved substantially and biorelevant media composition have been refined. The aim of this study was to propose optimized biorelevant testing conditions for modified release products, to evaluate the reproducibility of the optimized compendial apparatus III (USP apparatus III) and compendial apparatus IV (USP apparatus IV, open-loop mode) dissolution methods and to evaluate the usefulness of these methods to forecast the direction of food effects, if any, based on the results of two «ring¼ studies and by using two model modified release (MR) products, Ciproxin / Cipro XR and COREG CR. Six OrBiTo partners participated in each of the ring studies. All laboratories were provided with standard protocols, pure drug substance, and dose units. For the USP apparatus III, the dissolution methods applied to Ciproxin / Cipro XR, a monolithic MR product of an active pharmaceutical ingredient (API) with moderate aqueous solubility, were robust with low intra- and inter-laboratory data variability. Data from all partners were in line on a qualitative basis with food effect data in humans. For the USP apparatus IV, the dissolution methods applied to COREG CR, a multiparticulate, pH dependent, MR product of an API with low and pH dependent solubility led to high intra- and inter- laboratory data variability. Data from all partners were in line, on a qualitative basis, with the previously observed food effects in humans.


Assuntos
Química Farmacêutica/métodos , Ciprofloxacina/farmacocinética , Liberação Controlada de Fármacos , Interações Alimento-Droga , Trato Gastrointestinal , Disponibilidade Biológica , Ciprofloxacina/administração & dosagem , Ciprofloxacina/química , Combinação de Medicamentos , Liberação Controlada de Fármacos/fisiologia , Interações Alimento-Droga/fisiologia , Trato Gastrointestinal/efeitos dos fármacos , Trato Gastrointestinal/fisiologia , Humanos , Hidrocortisona/química , Hidrocortisona/farmacocinética , Solubilidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA