Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 20
Filtrar
1.
Lab Med ; 55(2): 162-168, 2024 Mar 07.
Artigo em Inglês | MEDLINE | ID: mdl-37294928

RESUMO

OBJECTIVE: To investigate the association of immune response with vaccination adverse effects at peak anti-receptor-binding domain spike subunit 1 (anti-RBDS1) IgG after full vaccination with Comirnaty, Spikevax, or Vaxzevria. METHODS: Anti-RBDS1 IgG concentrations after vaccination were determined in healthy adults vaccinated with the Comirnaty, Spikevax, and Vaxzevria vaccines. The association of reactogenicity and peak antibody response after vaccination was tested. RESULTS: Anti-RBDS1 IgG values were significantly higher in the Comirnaty and Spikevax group, compared with the Vaxzevria group (P < .001). Fever and muscle pain were found to be significant independent predictors of peak anti-RBDS1 IgG in the Comirnaty and Spikevax groups (P = .03 and P = .02, respectively). The multivariate model, adjusted for covariates, showed that no association between reactogenicity and peak antibody concentrations was found in the Comirnaty, Spikevax, and Vaxzevria groups. CONCLUSIONS: No association between reactogenicity and peak anti-RBDS1 IgG after vaccination with the Comirnaty, Spikevax, and Vaxzevria vaccine was found.


Assuntos
Vacinas contra COVID-19 , COVID-19 , Imunogenicidade da Vacina , Imunoglobulina G , Adulto , Humanos , Vacina de mRNA-1273 contra 2019-nCoV , Vacina BNT162 , ChAdOx1 nCoV-19 , COVID-19/prevenção & controle , Vacinas contra COVID-19/imunologia
2.
Int J Mol Sci ; 24(4)2023 Feb 17.
Artigo em Inglês | MEDLINE | ID: mdl-36835450

RESUMO

Melatonin is the main hormone that regulates the sleep cycle, and it is mostly produced by the pineal gland from the amino acid tryptophan. It has cytoprotective, immunomodulatory, and anti-apoptotic effects. Melatonin is also one of the most powerful natural antioxidants, directly acting on free radicals and the intracellular antioxidant enzyme system. Furthermore, it participates in antitumor activity, hypopigmentation processes in hyperpigmentary disorders, anti-inflammatory, and immunomodulating activity in inflammatory dermatoses, maintaining the integrity of the epidermal barrier and thermoregulation of the body. Due predominantly to its positive influence on sleep, melatonin can be used in the treatment of sleep disturbances for those with chronic allergic diseases accompanied by intensive itching (such as atopic dermatitis and chronic spontaneous urticaria). According to the literature data, there are also many proven uses for melatonin in photoprotection and skin aging (due to melatonin's antioxidant effects and role in preventing damage due to DNA repair mechanisms), hyperpigmentary disorders (e.g., melasma) and scalp diseases (such as androgenic alopecia and telogen effluvium).


Assuntos
Alopecia em Áreas , Dermatite Atópica , Melatonina , Humanos , Melatonina/metabolismo , Pele/metabolismo , Antioxidantes/metabolismo , Dermatite Atópica/patologia
4.
Biomol Biomed ; 23(1): 176-186, 2023 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-36036057

RESUMO

High prevalence and mortality of prostate cancer (PCa) are well known global health issues. Novel biomarkers for better identifying patients with PCa are the subject of extensive research. Prostate specific antigen (PSA) shows low specificity in screening and diagnostics, leading to unnecessary biopsies and health costs. Eighty patients with PCa and benign prostate hyperplasia (BPH) were included in the study. We analyzed CAV1 gene expression and methylation in tissue. CAV1 cfDNA methylation from blood and seminal plasma was accessed as a potential PCa biomarker. Although methylation in blood plasma did not differ between PCa and BPH patients, methylation in seminal plasma showed better PCa biomarker performances than tPSA (AUC 0.63 vs. AUC 0.52). Discrimination of BPH and Gleason grade group 1 PCa patients from patients with higher Gleason grade groups revealed very good performance as well (AUC 0.72). CAV1 methylation is useful biomarker with potential for further seminal plasma cfDNA research, but its diagnostic accuracy should be improved, as well as general knowledge about cfDNA in seminal plasma.


Assuntos
Ácidos Nucleicos Livres , Hiperplasia Prostática , Neoplasias da Próstata , Masculino , Humanos , Metilação , Ácidos Nucleicos Livres/metabolismo , Caveolina 1/genética , Neoplasias da Próstata/diagnóstico , Biomarcadores/metabolismo
5.
Acta Clin Croat ; 62(2): 373-377, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38549588

RESUMO

Chronic spontaneous urticaria (CSU) is a dermatological disorder accompanied by itching that greatly affects the quality of life and quality of sleep. Therefore, it is assumed that CSU patients consequently experience reduced melatonin secretion and lower values of serum or salivary melatonin. This pilot study included 20 patients with CSU (chronic urticaria of unknown etiology that lasts for more than 6 weeks) and 10 healthy controls. All subjects were examined by a dermatovenereologist-allergist, as well as an oral pathologist, to exclude oral pathological conditions. Salivary melatonin levels were determined by ELISA and all subjects completed a standardized Dermatology Life Quality Index questionnaire and Pittsburgh Sleep Quality Index on the same day they gave a saliva sample for analysis. According to our results, 86% of CSU patients had decreased values of salivary melatonin, and lower salivary melatonin values significantly correlated with a reduced quality of life in CSU patients. This study was the first to analyze melatonin in CSU patients, also suggesting a possible new therapeutic option for the treatment of CSU.


Assuntos
Urticária Crônica , Melatonina , Urticária , Humanos , Qualidade de Vida , Projetos Piloto , Melatonina/uso terapêutico , Doença Crônica
6.
Acta Stomatol Croat ; 56(2): 154-161, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35821725

RESUMO

Objectives: To determine the differences between pediatric patients with eating disorders (ED) and the control group in the amount of saliva and the concentration of total amylase and electrolytes in saliva, and to evaluate the correlation between the saliva changes and nutritional status. Material and methods: The study included 101 participants (14.34 ±1.99 years), out of which 50 participants with ED subgroups and 51 participants in the control group. Data were statistically analyzed (Mann-Whitney, Kruskal-Wallis, chi-square, Spearman rank correlation test, α=0.05). Results: No significant differences in salivary volume between the groups were found. A significant difference in the volume of saliva secreted in the 5th and 15th minute was found between the anorexia nervosa and bulimia nervosa subgroups. The examined anthropometric parameters were marginally or significantly positively associated with saliva volume at 5 and 15 minutes, noting a more significant correlation of the same at 15 than at 5 minutes. The patients with ED had a significantly higher concentration of inorganic phosphates in saliva while the concentrations of other electrolytes and total amylase in saliva did not differ significantly. Conclusions: Nutritional status affects salivation. There is a difference in saliva volume in pediatric patients with different ED disorders. Variations in saliva electrolytes in pediatric patients with ED are possible.

7.
Clin Chem Lab Med ; 60(5): 714-725, 2022 04 26.
Artigo em Inglês | MEDLINE | ID: mdl-35212494

RESUMO

OBJECTIVES: Hemolysis is associated with erroneous or delayed results. Objectives of the study were to compare four different methods for obtaining hemolysis in vitro on three different analyzers. METHODS: Hemolysis was prepared with addition of pure hemoglobin into serum pool, osmotic shock, aspiration through blood collection needle, freezing/thawing of whole blood. Biochemistry parameters were measured in duplicate at Architect c8000 (Abbott, Abbott Park, USA), Beckman Coulter AU680 (Beckman Coulter, Brea, USA) and Cobas 6000 c501 (Roche, Mannheim, Germany), according to manufacturers' declarations. Cut-off value was defined as the highest value of H index with corresponding bias lower than acceptance criteria. RESULTS: We were not able to obtain results with freezing protocol. On all three platforms, lowest number of analytes were sensitive to hemolysis at H=0.5 using method of adding free hemoglobin. When osmotic shock was used, cut-off values for the most analytes were generally met at lower values. Hemolysis significantly interfered with measurement of potassium and lactate dehydrogenase (LD) at H=0.5 on all platforms. The most of the tested analytes had the lowest acceptable H index when aspiration method was used. At the low level of hemolysis (H=0.8) glucose, sodium, potassium, chloride, phosphate, and LD were affected on all analyzers, with some additional analytes depending on the manufacturer. CONCLUSIONS: Hemolysis interference differs on different analyzers and according to protocol for obtaining hemolysis. Aspiration method was generally the most sensitive to hemolysis interference, while addition of free Hb was the most resistant.


Assuntos
Hemólise , Sódio , Testes Hematológicos , Hemoglobinas/análise , Humanos , Soro/química
8.
Cancers (Basel) ; 13(18)2021 Sep 19.
Artigo em Inglês | MEDLINE | ID: mdl-34572923

RESUMO

Prostate cancer (PC) is the most common malignancy in men. Common characteristic involved in PC pathogenesis are disturbed lipid metabolism and abnormal cholesterol accumulation. Cholesterol can be further utilized for membrane or hormone synthesis while cholesterol biosynthesis intermediates are important for oncogene membrane anchoring, nucleotide synthesis and mitochondrial electron transport. Since cholesterol and its biosynthesis intermediates influence numerous cellular processes, in this review we have described cholesterol homeostasis in a normal cell. Additionally, we have illustrated how commonly deregulated signaling pathways in PC (PI3K/AKT/MTOR, MAPK, AR and p53) are linked with cholesterol homeostasis regulation.

9.
Front Cell Dev Biol ; 9: 686149, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34552921

RESUMO

While tissue biopsy has for the longest time been the gold-standard in biomedicine, precision/personalized medicine is making the shift toward liquid biopsies. Cell-free DNA (cfDNA) based genetic and epigenetic biomarkers reflect the molecular status of its tissue-of-origin allowing for early and non-invasive diagnostics of different pathologies. However, selection of preanalytical procedures (including cfDNA isolation) as well as analytical methods are known to impact the downstream results. Calls for greater standardization are made continuously, yet comprehensive assessments of the impact on diagnostic parameters are lacking. This study aims to evaluate the preanalytic and analytic factors that influence cfDNA diagnostic parameters in blood and semen. Text mining analysis has been performed to assess cfDNA research trends, and identify studies on isolation methods, preanalytical and analytical impact. Seminal and blood plasma were tested as liquid biopsy sources. Traditional methods of cfDNA isolation, commercial kits (CKs), and an in-house developed protocol were tested, as well as the impact of dithiothreitol (DTT) on cfDNA isolation performance. Fluorimetry, qPCR, digital droplet PCR (ddPCR), and bioanalyzer were compared as cfDNA quantification methods. Fragment analysis was performed by qPCR and bioanalyzer while the downstream application (cfDNA methylation) was analyzed by pyrosequencing. In contrast to blood, semen as a liquid biopsy source has only recently begun to be reported as a liquid biopsy source, with almost half of all publications on it being review articles. Experimental data revealed that cfDNA isolation protocols give a wide range of cfDNA yields, both from blood and seminal plasma. The addition of DTT to CKs has improved yields in seminal plasma and had a neutral/negative impact in blood plasma. Capillary electrophoresis and fluorometry reported much higher yields than PCR methods. While cfDNA yield and integrity were highly impacted, cfDNA methylation was not affected by isolation methodology or DTT. In conclusion, NucleoSnap was recognized as the kit with the best overall performance. DTT improved CK yields in seminal plasma. The in-house developed protocol has shown near-kit isolation performance. ddPCR LINE-1 assay for absolute detection of minute amounts of cfDNA was established and allowed for quantification of samples inhibited in qPCR. cfDNA methylation was recognized as a stable biomarker unimpacted by cfDNA isolation method. Finally, semen was found to be an abundant source of cfDNA offering potential research opportunities and benefits for cfDNA based biomarkers development related to male reproductive health.

10.
Cancers (Basel) ; 13(9)2021 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-33922968

RESUMO

Prostate cancer (PCa) is the most commonly diagnosed neoplasm among men. Since it often resembles benign prostate hyperplasia (BPH), biomarkers with a higher differential value than PSA are required. Epigenetic biomarkers in liquid biopsies, especially miRNA, could address this challenge. The absolute expression of miR-375-3p, miR-182-5p, miR-21-5p, and miR-148a-3p were quantified in blood plasma and seminal plasma of 65 PCa and 58 BPH patients by digital droplet PCR. The sensitivity and specificity of these microRNAs were determined using ROC curve analysis. The higher expression of miR-182-5p and miR-375-3p in the blood plasma of PCa patients was statistically significant as compared to BPH (p = 0.0363 and 0.0226, respectively). Their combination achieved a specificity of 90.2% for predicting positive or negative biopsy results, while PSA cut-off of 4 µg/L performed with only 1.7% specificity. In seminal plasma, miR-375-3p, miR-182-5p, and miR-21-5p showed a statistically significantly higher expression in PCa patients with PSA >10 µg/L compared to ones with PSA ≤10 µg/L. MiR-182-5p and miR-375-3p in blood plasma show higher performance than PSA in discriminating PCa from BPH. Seminal plasma requires further investigation as it represents an obvious source for PCa biomarker identification.

11.
Cancers (Basel) ; 14(1)2021 Dec 31.
Artigo em Inglês | MEDLINE | ID: mdl-35008352

RESUMO

Seminoma (SE) is the most frequent type of testicular tumour, affecting predominantly young men. Early detection and diagnosis of SE could significantly improve life quality and reproductive health after diagnosis and treatment. Copy number variation (CNV) has already been associated with various cancers as well as SE. In this study, we selected four genes (MAGEC2, NANOG, RASSF1A, and KITLG) for CNV analysis in genomic DNA (gDNA), which are located on chromosomes susceptible to gains, and whose aberrant expression was already detected in SE. Furthermore, CNV was analysed in cell-free DNA (cfDNA) from seminal plasma. Analysis was performed by droplet digital polymerase chain reaction (ddPCR) on gDNA from SE and nonmalignant testicular tissue. Seminal plasma cfDNA from SE patients before and after surgery was analysed, as well as from healthy volunteers. The CNV hotspot in gDNA from SE tissue was detected for the first time in all analysed genes, and for two genes, NANOG and KITLG it was reflected in cfDNA from seminal plasma. Although clinical value is yet to be determined, presented data emphasize a potential use of CNV as a potential SE biomarker from a liquid biopsy.

12.
Biochem Med (Zagreb) ; 30(2): 020501, 2020 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-32550812

RESUMO

Within the last several years, frequency of vitamin D testing has multiplied substantially all over the world, since it has been shown to have an important role in many diseases and conditions. Even though liquid chromatography - tandem mass spectrometry (LC-MS/MS) has been identified as "gold standard" method for vitamin D measurement, most laboratories still use immunochemistry methods. Besides analytical problems (hydrophobicity, low circulating concentrations, ability to bind to lipids, albumins and vitamin D binding protein, presence of multiple vitamin D metabolites and variable ratios of 25(OH)D2 and 25(OH)D3 in the blood), vitamin D shows great preanalytical variability, since its concentration is drastically influenced by seasonal changes, exposure to sun, type of clothes or sun block creams. Vitamin D is mostly measured in serum or plasma, but new studies are showing importance of measuring vitamin D in pleural effusions, breast milk, urine, synovial fluid and saliva. Besides the main role in calcium homeostasis and bone metabolism, many studies linked vitamin D deficiency with cancer, cardiovascular diseases, diabetes, fertility and many other conditions. However, even though initial observational studies indicated that supplementation with vitamin D might be beneficial in disease development and progression; first results of well-designed randomized controlled prospective studies did not find differences in frequency of cardiovascular events or invasive cancer between patients taking vitamin D supplementation compared to placebo. In the light of these recent findings, validity of excessive vitamin D testing remains an open question.


Assuntos
Deficiência de Vitamina D/sangue , Deficiência de Vitamina D/fisiopatologia , Vitamina D/sangue , Vitamina D/fisiologia , Animais , Doenças Cardiovasculares/sangue , Cromatografia Líquida , Diabetes Mellitus/sangue , Feminino , Fertilidade , Hemólise , Humanos , Hiperlipidemias/sangue , Icterícia/sangue , Pneumopatias/sangue , Masculino , Neoplasias/sangue , Doenças Reumáticas/sangue , Estações do Ano , Espectrometria de Massas em Tandem
13.
Rheumatol Int ; 40(9): 1455-1461, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32462255

RESUMO

Vitamin D is beneficial in patients with immune-mediated rheumatic diseases as it has been shown that it lowers the incidence risk and the level of inflammation. To examine the association between clinical outcomes and initial 25-hydroxyvitamin D [25(OH)D] concentrations in patients with the immune-mediated rheumatic diseases treated with infliximab for 9 months. This study was performed in patients with rheumatoid arthritis (RA), ankylosing spondylitis (AS) and psoriatic arthritis (PsA) treated with infliximab for at least 38 weeks. Disease activity was assessed using Disease Activity Score (DAS28) for RA and PsA and Bath Ankylosing Spondylitis Disease Activity Index (BASDAI) for AS, while the global assessment was performed using the Visual Analogue Scale (VAS). Patients were divided into 2 groups according to 25(OH)D concentration which was classified as deficient or non-deficient (below and above 50 nmol/L, respectively). Concentrations of infliximab (IFX) and C-reactive protein (CRP) were measured according to the manufacturer's instructions.This study was performed in patients with rheumatoid arthritis (RA), ankylosing spondylitis (AS) and psoriatic arthritis (PsA) treated with infliximab for at least 38 weeks. Disease activity was assessed using Disease Activity Score (DAS28) for RA and PsA and Bath Ankylosing Spondylitis Disease Activity Index (BASDAI) for AS, while the global assessment was performed using the Visual Analogue Scale (VAS). Patients were divided into 2 groups according to 25(OH)D concentration which was classified as deficient or non-deficient (below and above 50 nmol/L, respectively). Concentrations of infliximab (IFX) and C-reactive protein (CRP) were measured according to the manufacturer's instructions. The study included 23 patients (14 with RA, 6 with AS and 3 with PsA), median age 54 years, 15 females. Vitamin D deficient and non-deficient groups had median initial concentrations of 38 and 61 nmol/L, respectively. DAS28 and pain on VAS calculated at the 2nd and 38th week showed a statistically significant decrease only in RA and PsA patients with vitamin D deficiency (P = 0.02 and 0.06, respectively). Lower initial concentration of 25(OH)D in patients treated with infliximab was associated with better improvement of clinical measures (DAS28 and VAS) of disease after 9 months of therapy.


Assuntos
Artrite Psoriásica/tratamento farmacológico , Artrite Reumatoide/complicações , Deficiência de Vitamina D/complicações , Vitamina D/análogos & derivados , Adulto , Idoso , Antirreumáticos/uso terapêutico , Artrite Reumatoide/sangue , Artrite Reumatoide/tratamento farmacológico , Proteína C-Reativa/análise , Estudos de Casos e Controles , Feminino , Humanos , Infliximab/uso terapêutico , Masculino , Pessoa de Meia-Idade , Medição da Dor , Estudos Retrospectivos , Índice de Gravidade de Doença , Espondilite Anquilosante/tratamento farmacológico , Vitamina D/sangue , Deficiência de Vitamina D/sangue
14.
Biochem Med (Zagreb) ; 30(2): 020701, 2020 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-32292279

RESUMO

INTRODUCTION: Our aim was to investigate the stability of clinically relevant analytes in pleural and peritoneal fluids stored in variable time periods and variable storage temperatures prior to analysis. MATERIALS AND METHODS: Baseline total proteins (TP), albumin (ALB), lactate dehydrogenase (LD), cholesterol (CHOL), triglycerides (TRIG), creatinine (CREA), urea, glucose and amylase (AMY) were measured using standard methods in residual samples from 29 pleural and 12 peritoneal fluids referred to our laboratory. Aliquots were stored for 6 hours at room temperature (RT); 3, 7, 14 and 30 days at - 20°C. At the end of each storage period, all analytes were re-measured. Deviations were calculated and compared to stability limits (SL). RESULTS: Pleural fluid TP and CHOL did not differ in the observed storage periods (P = 0.265 and P = 0.170, respectively). Statistically significant differences were found for ALB, LD, TRIG, CREA, urea, glucose and AMY. Peritoneal fluid TP, ALB, TRIG, urea and AMY were not statistically different after storage, contrary to LD, CHOL, CREA and glucose. Deviations for TP, ALB, CHOL, TRIG, CREA, urea and AMY in all storage periods tested for both serous fluids were within the SL. Deviations exceeding SL were observed for LD and glucose when stored for 3 and 7 days at - 20°C, respectively. CONCLUSIONS: TP, ALB, CHOL, TRIG, CREA, urea and AMY are stable in serous samples stored up to 6 hours at RT and/or 30 days at - 20°C. Glucose is stable up to 6 hours at RT and 3 days at - 20°C. The stability of LD in is limited to 6 hours at RT.


Assuntos
Líquido Ascítico/química , Análise Química do Sangue/normas , Química Clínica/normas , Derrame Pleural/sangue , Idoso , Idoso de 80 Anos ou mais , Coleta de Amostras Sanguíneas/normas , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Fatores de Tempo
16.
Clin Chem Lab Med ; 57(12): 1882-1887, 2019 Nov 26.
Artigo em Inglês | MEDLINE | ID: mdl-31343976

RESUMO

Background Serum samples should be centrifuged for at least 10 min at 1300-2500 × g. Changed centrifugation conditions could compromise sample quality. The objective of this study was to compare the serum quality and turnaround time (TAT) using different centrifugation conditions. Methods The study was done in four different periods (A, B, C and D) at different conditions: for 10, 5 and 7 (A, B and C, respectively) at 2876 × g, and 7 (D) min at 4141 × g. Sample quality was assessed as the proportion of samples with: (a) aspiration errors, (b) H index >0.5 g/L and (c) suppressed reports of potassium (K) due to hemolysis. TAT was calculated for emergency samples. The proportions of samples (a), (b) and (c) were compared according to period A. Results The number of aspiration errors was significantly higher in samples centrifuged at 2876 × g for 5 min (p = 0.021) and remained unchanged when centrifuged for 7 min (p = 0.066 and 0.177, for periods C and D, respectively). In periods B, C and D, the proportion of samples with hemolysis was higher than that in period A (p-values 0.039, 0.009 and 0.042, respectively). TAT differed between all periods (p < 0.001), with the lowest TAT observed for B and D. The lowest number of samples exceeding 60-min TAT was observed in period D (p = 0.011). Conclusions The integrity of serum samples is changed with different centrifugation conditions than those recommended. Our study showed that shorter centrifugation at higher force (7 min at 4141 × g) significantly decreases TAT, with unchanged proportion of samples with aspiration errors.


Assuntos
Coleta de Amostras Sanguíneas/métodos , Centrifugação/métodos , Humanos , Reprodutibilidade dos Testes , Soro/química , Fatores de Tempo
17.
Clin Chem Lab Med ; 57(2): 183-194, 2018 12 19.
Artigo em Inglês | MEDLINE | ID: mdl-30055099

RESUMO

Background Nowadays over-the-counter (OTC) drugs and dietary supplements are widely used. Their use can have a significant impact on the validity of laboratory results. The aim of this multicenter European study was to determine the frequency of consumption of various dietary products and OTC drugs among patients and explore their level of knowledge and awareness about the potential impact of various products on laboratory test results. Methods Eighteen European countries participated in this study. The survey was carried out anonymously on a subsequent series of outpatients (n=200) in each participating country. Included were patients who were referred to the laboratory for blood sampling and who voluntarily agreed to participate in the study. The survey included questions about the frequency of consumption of various products, awareness of the importance of informing physicians and laboratory staff about it and information about influence of preanalytical factors in general on laboratory test results. Results In total, 68% of patients were regularly taking at least one OTC drug or dietary supplement. The frequency of patients consuming at least one OTC drug or dietary supplement differed between countries (p=0.001). Vitamins (38%), minerals (34%), cranberry juice (20%), acetylsalicylic acid (ASA) (17%) and omega fatty acids (17%) were the most commonly used in our study. Conclusions The use of various OTC drugs and dietary supplements is highly prevalent in Europe and patients are often not willing to disclose this information to the laboratory staff and ordering physician. The education of both patients and healthcare staff is needed.


Assuntos
Conscientização , Testes de Química Clínica , Suplementos Nutricionais , Conhecimento , Medicamentos sem Prescrição , Pacientes/psicologia , Europa (Continente) , Humanos , Inquéritos e Questionários
18.
Clin Chem Lab Med ; 56(5): 776-788, 2018 04 25.
Artigo em Inglês | MEDLINE | ID: mdl-29315074

RESUMO

BACKGROUND: The aim of our study was to perform verification of serum indices on three clinical chemistry platforms. METHODS: This study was done on three analyzers: Abbott Architect c8000, Beckman Coulter AU5800 (BC) and Roche Cobas 6000 c501. The following analytical specifications were verified: precision (two patient samples), accuracy (sample with the highest concentration of interferent was serially diluted and measured values compared to theoretical values), comparability (120 patients samples) and cross reactivity (samples with increasing concentrations of interferent were divided in two aliquots and remaining interferents were added in each aliquot. Measurements were done before and after adding interferents). RESULTS: Best results for precision were obtained for the H index (0.72%-2.08%). Accuracy for the H index was acceptable for Cobas and BC, while on Architect, deviations in the high concentration range were observed (y=0.02 [0.01-0.07]+1.07 [1.06-1.08]x). All three analyzers showed acceptable results in evaluating accuracy of L index and unacceptable results for I index. The H index was comparable between BC and both, Architect (Cohen's κ [95% CI]=0.795 [0.692-0.898]) and Roche (Cohen's κ [95% CI]=0.825 [0.729-0.922]), while Roche and Architect were not comparable. The I index was not comparable between all analyzer combinations, while the L index was only comparable between Abbott and BC. Cross reactivity analysis mostly showed that serum indices measurement is affected when a combination of interferences is present. CONCLUSIONS: There is heterogeneity between analyzers in the hemolysis, icteria, lipemia (HIL) quality performance. Verification of serum indices in routine work is necessary to establish analytical specifications.


Assuntos
Bilirrubina/sangue , Análise Química do Sangue , Hiperlipidemias/sangue , Lipídeos/sangue , Hemólise , Humanos , Qualidade da Assistência à Saúde
19.
Lab Med ; 47(1): 39-42, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26732780

RESUMO

OBJECTIVE: To determine whether K2-ethylenediaminetetraacetic acid (EDTA) and K3-EDTA Greiner tubes could be used interchangeably for glycosylated hemoglobin, type A1C (HbA1c) measurement via the Abbott Laboratories ARCHITECT chemiluminescent microparticle HbA1c assay on the ARCHITECT i2000SR immunoanalyzer at our university hospital. MATERIALS: We drew blood from a total of 45 outpatients into plastic Greiner Vacuette tubes, some of which were lined with K2-EDTA and others with K3-EDTA anticoagulant. Data are presented as median and interquartile range values. We used the Wilcoxon test and Passing-Bablok regression for tube comparison. RESULTS: For K2-EDTA tubes median HbA1c concentration was 54 mmol/mol (41 to 71 mmol/mol) and for K3-EDTA tubes 56 mmol/mol (43 to 69 mmol/mol). There was no statistically significant difference between K2-EDTA and K3-EDTA (bias= -1.29 mmol/mol; P = 0.24). Passing-Bablok regression showed that there is no constant and proportional error: y = -0.23 (95% CI[-3.52 to 0.69]) + 1.00( 95% CI[0.98 to 1.06]) x. CONCLUSION: In this study, we provide evidence for the lack of any clinically and statistically significant bias between K2-EDTA and K3-EDTA HbA1c measurements. Thus, Greiner tubes lined with K2-EDTA and those lined with K3-EDTA can safely be used interchangeably to measure HbA1c via the Abbott Laboratories ARCHITECT assay.


Assuntos
Diabetes Mellitus/diagnóstico , Testes Diagnósticos de Rotina/métodos , Hemoglobinas Glicadas/análise , Medições Luminescentes/métodos , Manejo de Espécimes/métodos , Anticoagulantes/farmacologia , Hospitais Universitários , Humanos
20.
Clin Chem Lab Med ; 54(3): 419-25, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26426892

RESUMO

BACKGROUND: Endogenous interferences are an important source of biased laboratory results. Hemolysis, lipemia and icteria are the main source of endogenous interference in laboratory medicine. Accreditation according to ISO 15189 improves the overall quality of the laboratory procedures. The aim of our study was i) to assess the level of knowledge of Croatian medical biochemists about the proper detection and management of hemolysis, lipemia and icteria; and ii) to identify possible differences in the level of knowledge respective to the laboratory accreditation status. METHODS: An on-line self-report survey was carried out by the Working Group for Preanalytical Phase of the Croatian Society of Medical Biochemistry and Laboratory Medicine during April to May 2015. Survey included 14 statements (Q1-Q14) about procedures for samples with interferences and participants were asked to assess the degree of agreement with the statement using a 4-point Likert scale. RESULTS: The lowest level of knowledge was observed for statements Q10 (dealing with icteric sample; 40.9% participants agreed with the correct procedure), Q12 (allowable error for interference; 47.2%) and Q11 (dealing with lipemic sample; 60.1%). Almost all participants (97.4%) agreed that laboratories in Croatia should have a harmonized protocol for management of samples with interferences. Participants from accredited laboratories showed higher knowledge of hemolysis detection (p=0.031), rejection of hemolyzed sample (p<0.001), management of icteric samples (p=0.038) and allowable error for interferences (p=0.040). CONCLUSIONS: Croatian laboratories have a good knowledge of the proper detection and management of hemolyzed, icteric and lipemic samples. Accreditation is associated with higher knowledge about management of samples with interferences.


Assuntos
Hemólise , Hiperlipidemias/sangue , Icterícia/sangue , Laboratórios Hospitalares/normas , Acreditação , Croácia , Humanos , Inquéritos e Questionários , Recursos Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA