Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
1.
Nanoscale ; 16(10): 5149-5163, 2024 Mar 07.
Artigo em Inglês | MEDLINE | ID: mdl-38265106

RESUMO

Given the growing scientific and industrial interests in green microalgae, a comprehensive understanding of the forces controlling the colloidal stability of these bioparticles and their interactions with surrounding aqueous microenvironment is required. Accordingly, we addressed here the electrostatic and hydrophobic surface properties of Chlorella vulgaris from the population down to the individual cell levels. We first investigated the organisation of the electrical double layer at microalgae surfaces on the basis of electrophoresis measurements. Interpretation of the results beyond zeta-potential framework underlined the need to account for both the hydrodynamic softness of the algae cells and the heterogeneity of their interface formed with the outer electrolyte solution. We further explored the nature of the structural charge carriers at microalgae interfaces through potentiometric proton titrations. Extraction of the electrostatic descriptors of interest from such data was obscured by cell physiology processes and dependence thereof on prevailing measurement conditions, which includes light, temperature and medium salinity. As an alternative, cell electrostatics was successfully evaluated at the cellular level upon mapping the molecular interactions at stake between (positively and negatively) charged atomic force microscopy tips and algal surface via chemical force microscopy. A thorough comparison between charge-dependent tip-to-algae surface adhesion and hydrophobicity level of microalgae surface evidenced that the contribution of electrostatics to the overall interaction pattern is largest, and that the electrostatic/hydrophobic balance can be largely modulated by pH. Overall, the combination of multiscale physicochemical approaches allowed a drawing of some of the key biosurface properties that govern microalgae cell-cell and cell-surface interactions.


Assuntos
Chlorella vulgaris , Microalgas , Prótons , Propriedades de Superfície , Água , Interações Hidrofóbicas e Hidrofílicas , Microalgas/metabolismo
2.
Front Bioeng Biotechnol ; 11: 1063063, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36845172

RESUMO

Alternating current scanning electrochemical microscopy (AC-SECM) is a powerful tool for characterizing the electrochemical reactivity of surfaces. Here, perturbation in the sample is induced by the alternating current and altered local potential is measured by the SECM probe. This technique has been used to investigate many exotic a range of biological interfaces including live cells and tissues, as well as the corrosive degradation of various metallic surfaces, etc. In principle, AC-SECM imaging is derived from electrochemical impedance spectroscopy (EIS) which has been used for a century to describe interfacial and diffusive behaviour of molecules in solution or on a surface. Increasingly bioimpedance centric medical devices have become an important tool to detect evolution of tissue biochemistry. Predictive implications of measuring electrochemical changes within a tissue is one of the core concepts in developing minimally invasive and smart medical devices. In this study, cross sections of mice colon tissue were used for AC-SECM imaging. A 10 micron sized platinum probe was used for two-dimensional (2D) tan δ mapping of histological sections at a frequency of 10 kHz, Thereafter, multifrequency scans were performed at 100 Hz, 10 kHz, 300 kHz, and 900 kHz. Loss tangent (tan δ) mapping of mice colon revealed microscale regions within a tissue possessing a discrete tan δ signature. This tan δ map may be an immediate measure of physiological conditions in biological tissues. Multifrequency scans highlight subtle changes in protein or lipid composition as a function of frequency which was recorded as loss tangent maps. Impedance profile at different frequencies could also be used to identify optimal contrast for imaging and extracting the electrochemical signature specific for a tissue and its electrolyte.

3.
Cell Mol Bioeng ; 12(3): 203-214, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-31719910

RESUMO

INTRODUCTION: Over the last decade, atomic force microscopy (AFM) has played an important role in understanding nanomechanical properties of various cancer cell lines. This study is focused on Lewis lung carcinoma cell tumours as 3D multicellular spheroid (MS). Not much is know about the mechanical properties of the cells and the surrounding extracellular matrix (ECM) in rapidly growing tumours. METHODS: Depth-dependent indentation measurements were conducted with the AFM. Force-vs.-indentation curves were used to create stiffness profiles as a function of depth. Here studies were focused on the outer most layer, i.e., proliferation zone of the spheroid. RESULTS: Both surface and sub-surface stiffness profiles of MS were created. This study revealed three nanomechanical topographies, Type A-high modulus due to collagen fibers, Type B-high stiffness at cell membrane and ECM interface and Type C-increased modulus due to cell lying deep inside matrix at a depth of 1.35 µm. Both Type and Type-B topographies result from collagen-based structures in ECM. CONCLUSION: This study has first time revealed mechanical constitution of an MS. Depth-dependent indentation studies have the revealed role of various molecular and cellular components responsible for providing mechanical stability to MS. Nanomechanical heterogeneities revealed in this investigation can shed new light in developing correct dosage regime for collagenase treatment of tumours and designing better controlled artificial extracellular matrix systems for replicating tissue growth in-vitro.

4.
Ultrason Sonochem ; 57: 193-202, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-31208614

RESUMO

Acoustic tweezers facilitate the manipulation of objects using sound waves. With the current state of the technology one can only control mobility for a single or few microparticles. This article presents a state of the art system where an Acoustic Lens was used for developing a Micro-Acoustic Trap for microparticle assembly in 3D. The model particles, 2 µm diameter polystyrene beads in suspension, were driven via acoustic pressure to form a monolayer at wavelength-defined distances above the substrate defined by the focal point of an Acoustic Lens The transducer was driven at 89 MHz, mixed with 100 ms pulses at a repetition rate of 2 Hz. Beyond a threshold drive amplitude sufficient to overcome Brownian motion, this led to 2D assembly of the microparticles into close-packed rafts >80 µm across (∼5 wavelengths of the carrier wave and >40 particles across). This methodology was further extended to manipulation of live Dictyostelium discoideum amoebae. This approach therefore offers maneuverability in controlling or assembling micrometer-scale objects using continuous or pulsed focused acoustic radiation pressure.

5.
J Nanosci Nanotechnol ; 18(3): 1557-1567, 2018 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-29448630

RESUMO

The nanomechanical properties of various biological and cellular surfaces are increasingly investigated with Scanning Probe Microscopy. Surface stiffness measurements are currently being used to define metastatic properties of various cancerous cell lines and other related biological tissues. Here we present a unique methodology to understand depth dependent nanomechanical variations in stiffness in biopolymers and live cells. In this study we have used A2780 and NIH3T3 cell lines and 0.5% and 1% Agarose to investigate depth dependent stiffness and porosity on nanomechanical properties in different biological systems. This analytical methodology can circumvent the issue associated with the contribution of substrates on cell stiffness. Here we demonstrate that by calculating 'continuous-step-wise-modulus' on force versus distance curves one can observe minute variation as function of depth. Due to the presence of different kinds of cytoskeletal filament, dissipation of contact force might vary from one portion of a cell to another. On NIH3T3 cell lines, stiffness profile of Circular Dorsal Ruffles could be observed in form of large parabolic feature with changes in stiffness at different depth. In biopolymers like agarose, depending upon the extent of polymerization in there can be increase or decrease in stiffness due variations in pore size and extent to which crosslinking is taking place at different depths. 0.5% agarose showed gradual decrease in stiffness whereas with 1% agarose there was slight increase in stiffness as one indents deeper into its surface.


Assuntos
Hidrogéis , Animais , Fenômenos Biomecânicos , Células , Fenômenos Mecânicos , Camundongos , Microscopia de Força Atômica , Células NIH 3T3 , Sefarose
6.
Tissue Eng Part A ; 24(3-4): 254-263, 2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-28610471

RESUMO

Low-intensity pulsed ultrasound (LIPUS) has been shown to be effective for orthopedic fracture repair and nonunion defects, but the specific mechanism behind its efficacy is still unknown. Previously, we have shown a measurable acoustic radiation force at LIPUS intensities traditionally used for clinical treatment and have applied this force to osteoblastic cells encapsulated in type I collagen hydrogels. Our goal in this study is to provide insight and inform the appropriate design of a cell therapy approach to bone repair in which osteoblasts are embedded in collagen hydrogels, implanted into a bony defect, and then transdermally stimulated using LIPUS-derived acoustic radiation force to enhance bone formation at the earliest time points after bone defect repair. To this end, in this study, we demonstrate the ability to measure local hydrogel deformations in response to LIPUS-induced acoustic radiation force and reveal that hydrogel deformation varies with both LIPUS intensity and hydrogel stiffness. Specifically, hydrogel deformation is positively correlated with LIPUS intensity and this deformation is further increased by reducing the stiffness of the hydrogel. We have also shown that encapsulated osteoblastic cells respond to increases in LIPUS intensity by upregulating both cyclooxygenase 2 and prostaglandin E2 (PGE2), both implicated in new bone formation and well-established responses to the application of fluid forces on osteoblast cells. Finally, we demonstrate that combining an increase in LIPUS with a three-dimensional culture environment upregulates both markers beyond their expression noted from either experimental condition alone, suggesting that both LIPUS and hydrogel encapsulation, when combined and modulated appropriately, can enhance osteoblastic response considerably. These studies provide important information toward a clinically relevant cell therapy treatment for bone defects that allows the transdermal application of mechanical loading to bone defects without physically destabilizing the defect site.


Assuntos
Hidrogel de Polietilenoglicol-Dimetacrilato/química , Osteoblastos/citologia , Ultrassonografia/métodos , Animais , Linhagem Celular , Terapia Baseada em Transplante de Células e Tecidos/métodos , Ciclo-Oxigenase 2/metabolismo , Dinoprostona/metabolismo , Módulo de Elasticidade , Análise de Elementos Finitos , Consolidação da Fratura/fisiologia , Camundongos , Osteoblastos/efeitos da radiação , Osteogênese/fisiologia
7.
Exp Biol Med (Maywood) ; 241(10): 1149-56, 2016 05.
Artigo em Inglês | MEDLINE | ID: mdl-27229906

RESUMO

Ultrasound, or the application of acoustic energy, is a minimally invasive technique that has been used in diagnostic, surgical, imaging, and therapeutic applications. Low-intensity pulsed ultrasound (LIPUS) has been used to accelerate bone fracture repair and to heal non-union defects. While shown to be effective the precise mechanism behind its utility is still poorly understood. In this study, we considered the possibility that LIPUS may be providing a physical stimulus to cells within bony defects. We have also evaluated ultrasound as a means of producing a transdermal physical force that could stimulate osteoblasts that had been encapsulated within collagen hydrogels and delivered to bony defects. Here we show that ultrasound does indeed produce a measurable physical force and when applied to hydrogels causes their deformation, more so as ultrasound intensity was increased or hydrogel stiffness decreased. MC3T3 mouse osteoblast cells were then encapsulated within hydrogels to measure the response to this force. Statistically significant elevated gene expression for alkaline phosphatase and osteocalcin, both well-established markers of osteoblast differentiation, was noted in encapsulated osteoblasts (p < 0.05), suggesting that the physical force provided by ultrasound may induce bone formation in part through physically stimulating cells. We have also shown that this osteoblastic response is dependent in part on the stiffness of the encapsulating hydrogel, as stiffer hydrogels resulted in reducing or reversing this response. Taken together this approach, encapsulating cells for implantation into a bony defect that can potentially be transdermally loaded using ultrasound presents a novel regenerative engineering approach to enhanced fracture repair.


Assuntos
Substitutos Ósseos/efeitos da radiação , Hidrogel de Polietilenoglicol-Dimetacrilato/efeitos da radiação , Osteoblastos/fisiologia , Osteoblastos/efeitos da radiação , Ondas Ultrassônicas , Fosfatase Alcalina/biossíntese , Fosfatase Alcalina/genética , Animais , Regeneração Óssea , Linhagem Celular , Perfilação da Expressão Gênica , Camundongos , Osteocalcina/biossíntese , Osteocalcina/genética
8.
Nanobiomedicine (Rij) ; 3: 1849543516675348, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-29942390

RESUMO

The ability to modulate cardiomyocyte contractility is important for bioengineering applications ranging from heart disease treatments to biorobotics. In this study, we examined the changes in contraction frequency of neonatal rat cardiomyocytes upon single-cell-level nanoscale mechanical stimulation using atomic force microscopy. To measure the response of same density of cells, they were micropatterned into micropatches of fixed geometry. To examine the effect of the substrate stiffness on the behavior of cells, they were cultured on a stiffer and a softer surface, glass and poly (dimethylsiloxane), respectively. Upon periodic cyclic stimulation of 300 nN at 5 Hz, a significant reduction in the rate of synchronous contraction of the cell patches on poly(dimethylsiloxane) substrates was observed with respect to their spontaneous beat rate, while the cell patches on glass substrates maintained or increased their contraction rate after the stimulation. On the other hand, single cells mostly maintained their contraction rate and could only withstand a lower magnitude of forces compared to micropatterned cell patches. This study reveals that the contraction behavior of cardiomyocytes can be modulated mechanically through cyclic nanomechanical stimulation, and the degree and mode of this modulation depend on the cell connectivity and substrate mechanical properties.

9.
PLoS One ; 8(7): e68655, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23874708

RESUMO

We report on the systematic investigation of the role of surface nanoscale roughness and morphology on the charging behaviour of nanostructured titania (TiO2) surfaces in aqueous solutions. IsoElectric Points (IEPs) of surfaces have been characterized by direct measurement of the electrostatic double layer interactions between titania surfaces and the micrometer-sized spherical silica probe of an atomic force microscope in NaCl aqueous electrolyte. The use of a colloidal probe provides well-defined interaction geometry and allows effectively probing the overall effect of nanoscale morphology. By using supersonic cluster beam deposition to fabricate nanostructured titania films, we achieved a quantitative control over the surface morphological parameters. We performed a systematical exploration of the electrical double layer properties in different interaction regimes characterized by different ratios of characteristic nanometric lengths of the system: the surface rms roughness Rq, the correlation length ξ and the Debye length λD. We observed a remarkable reduction by several pH units of IEP on rough nanostructured surfaces, with respect to flat crystalline rutile TiO2. In order to explain the observed behavior of IEP, we consider the roughness-induced self-overlap of the electrical double layers as a potential source of deviation from the trend expected for flat surfaces.


Assuntos
Nanoestruturas/química , Soluções/química , Titânio/química , Ponto Isoelétrico , Propriedades de Superfície
10.
J Nanosci Nanotechnol ; 13(1): 77-85, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-23646700

RESUMO

The nanoscale interaction of bacterial cells with solid surfaces is a key issue in biomedicine because it constitutes the first pathogenic event in the complex series of biofilm development on prosthetic devices. We report on an Atomic Force Microscopy study of the interaction of Escherichia coli and Pseudomonas aeruginosa bacterial cells with nanostructured titania thin films with controlled and reproducible nanometer-scale morphology, produced by assembling Ti clusters from the gas phase in a Supersonic Cluster Beam Deposition apparatus. The results demonstrate that bacterial adhesion and biofilm formation are significantly influenced by a pure physical stimulus, that is, the nanoscale variation of surface topography. The increase of nanoscale film roughness promotes bacterial adhesion with respect to flat substrates; remarkably, Pseudomonas aeruginosa cells lose their flagella on nanostructured TiO2 thin films upon adhesion, as opposed to same bacteria onto reference smooth glass substrates. Further, we have observed increased cell biovolume and other biofilm properties on nanostructured substrates in comparison with smooth glasses. These findings suggest that the design of innovative biomaterials with a suitable patterning of biomaterials surfaces can be an effective approach to control the adhesion of microorganisms to in vivo implant surfaces with active biological functionalities.


Assuntos
Aderência Bacteriana/fisiologia , Biofilmes/crescimento & desenvolvimento , Microscopia de Força Atômica/métodos , Nanoestruturas/química , Nanoestruturas/microbiologia , Titânio/química , Teste de Materiais , Nanoestruturas/ultraestrutura , Tamanho da Partícula , Propriedades de Superfície
11.
J Neurosci Rural Pract ; 3(3): 301-10, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23188983

RESUMO

BACKGROUND: there is an intimate relation between transition metals and cell homeostasis due to the physiological necessity of metals in vivo. Particularly, iron (ferrous and ferric state) is utilized in many physiological processes of the cell but in excess has been linked with negative role contributing in many neurodegenerative processes. OBJECTIVE: the aim of this study was to investigate which oxidation state of ionic iron (Ferrous (II) versus Ferric (III)) is more toxic to neuronal cells (SHSY(5)Y). MATERIALS AND METHODS: The neuroblastoma (SHSY(5)Y) cells were exposed to varying concentration of ferric and ferrous iron. Morphological studies using immunofluorescence staining and microscopic analysis as confirmed by intracellular glutathione (GSH) test demonstrated oxidative stress to cells in iron microenvironment. In addition, MTT assay was performed to evaluate the viability and metabolic state of the cells. RESULTS: the results showed that ferrous form has significantly higher toxicity compared to the ferric ionic state of higher concentration. In addition, microscopic analysis shows cell fenestration at higher concentrations and swelling at intermediate ferric dosages as demonstrated by atomic force microscopy (AFM). Interestingly, the addition of a differentiation inducing factor, trans-retinoic rcid (RA) retains significant viability and morphological features of the cells irrespective of the ionic state of the iron. AFM images revealed clustered aggregates arising from iron chelation with RA. CONCLUSIONS: the results indicate that Fe (II) has more toxic effects on cells. In addition, it could be an interesting finding with respect to the antioxidant properties of RA as a chelating agent for the neurodegenerative therapeutics.

12.
Biofabrication ; 4(2): 025001, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-22406493

RESUMO

The contamination of implant devices as a result of biofilm formation through bacterial infection has instigated major research in this area, particularly to understand the mechanism of bacterial cell/implant surface interactions and their preventions. In this paper, we demonstrate a controlled method of nanostructured titanium oxide surface synthesis using supersonic cluster beam depositions. The nanoscale surface characterization using atomic force microscopy and a profilometer display a regulated evolution in nanomorphology and physical properties. X-ray photoelectron spectroscopy analyses display a stoichiometric nanostructured TiO(2) film. Measurement of the water contact angle shows a nominal increase in the hydrophilic nature of ns-TiO(2) films, whereas the surface energy increases with decreasing contact angle. Bacterial species Staphylococcus aureus and Escherichia coli interaction with nanostructured surfaces shows an increase in adhesion and biofilm formation with increasing nanoscale morphological properties. Conversely, limiting ns-TiO(2) film distribution to micro/nanopatterned designed substrates integrated with bovine serum albumin functionalization leads to a reduction in biofilm formations due to a globally decreased bacterial cell-surface interaction area. The results have potential implications in inhibiting bacterial colonization and promoting mammalian cell-implant interactions.


Assuntos
Aderência Bacteriana/efeitos dos fármacos , Biofilmes/efeitos dos fármacos , Biofilmes/crescimento & desenvolvimento , Nanoestruturas/química , Nanotecnologia/métodos , Titânio/farmacologia , Animais , Bovinos , Escherichia coli/efeitos dos fármacos , Escherichia coli/fisiologia , Microscopia , Nanoestruturas/ultraestrutura , Impressão , Soroalbumina Bovina/química , Staphylococcus aureus/efeitos dos fármacos , Staphylococcus aureus/fisiologia , Propriedades de Superfície , Titânio/química
13.
PLoS One ; 6(9): e25029, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-21966403

RESUMO

Bacterial infection of implants and prosthetic devices is one of the most common causes of implant failure. The nanostructured surface of biocompatible materials strongly influences the adhesion and proliferation of mammalian cells on solid substrates. The observation of this phenomenon has led to an increased effort to develop new strategies to prevent bacterial adhesion and biofilm formation, primarily through nanoengineering the topology of the materials used in implantable devices. While several studies have demonstrated the influence of nanoscale surface morphology on prokaryotic cell attachment, none have provided a quantitative understanding of this phenomenon. Using supersonic cluster beam deposition, we produced nanostructured titania thin films with controlled and reproducible nanoscale morphology respectively. We characterized the surface morphology; composition and wettability by means of atomic force microscopy, X-ray photoemission spectroscopy and contact angle measurements. We studied how protein adsorption is influenced by the physico-chemical surface parameters. Lastly, we characterized Escherichia coli and Staphylococcus aureus adhesion on nanostructured titania surfaces. Our results show that the increase in surface pore aspect ratio and volume, related to the increase of surface roughness, improves protein adsorption, which in turn downplays bacterial adhesion and biofilm formation. As roughness increases up to about 20 nm, bacterial adhesion and biofilm formation are enhanced; the further increase of roughness causes a significant decrease of bacterial adhesion and inhibits biofilm formation. We interpret the observed trend in bacterial adhesion as the combined effect of passivation and flattening effects induced by morphology-dependent protein adsorption. Our findings demonstrate that bacterial adhesion and biofilm formation on nanostructured titanium oxide surfaces are significantly influenced by nanoscale morphological features. The quantitative information, provided by this study about the relation between surface nanoscale morphology and bacterial adhesion points towards the rational design of implant surfaces that control or inhibit bacterial adhesion and biofilm formation.


Assuntos
Aderência Bacteriana , Biofilmes , Nanoestruturas/química , Adsorção , Materiais Biocompatíveis/química , Adesão Celular , Escherichia coli/metabolismo , Teste de Materiais , Microscopia de Força Atômica/métodos , Microscopia Confocal/métodos , Modelos Estatísticos , Staphylococcus aureus/metabolismo , Propriedades de Superfície , Titânio/química
14.
J Nanosci Nanotechnol ; 11(6): 4739-48, 2011 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-21770100

RESUMO

We report on the investigation of the adhesive properties of cluster-assembled nanostructured TiO(x) (ns-TiO(x)) films against a Si3N4 AFM tip, in air and in water. The interacting AFM tip apex represents a model nanometer-sized probe, carrying both silanol (Si-OH) and silamine (Si2-NH) groups: it is therefore well suited to investigate biologically relevant molecular interactions with the biocompatible ns-TiO(x) surface. Coupling nanosphere lithography with supersonic cluster beam deposition we produced sub-micrometer patterns of ns-TiO(x) on a reference amorphous silica surface. These devices are ideal platforms for conducting comparative nanoscale investigations of molecular interactions between surfaces and specific groups. We have found that in the aqueous medium the adhesion is enhanced on ns-TiO(x) with respect to amorphous silica, opposed to the case of humid air. A comparative analysis of the different interactions channels (van der Waals, electrostatic, chemical bonding) led to the conclusion that the key for understanding this behavior can be the ability of incoming nucleophiles like nitrogen or oxygen on the Si3N4 tip to displace adsorbed molecules on ns-TiO(x) and link to Ti atoms via co-ordinate (dative covalent) bonding. This effect is likely enhanced on nanostructured TiO(x) with respect to crystalline or micro-porous TiO2, due to the greatly increased effective area and porosity. This study provides a clue for the understanding of interaction mechanisms of proteins with biocompatible ns-TiO(x), and in general with metal-oxide surfaces.


Assuntos
Materiais Biocompatíveis/química , Microscopia de Força Atômica/métodos , Nanopartículas/química , Titânio/química , Adesividade , Interações Hidrofóbicas e Hidrofílicas , Compostos de Silício/química , Eletricidade Estática , Molhabilidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA