Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Talanta ; 278: 126467, 2024 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-38968657

RESUMO

The combination of CRISPR technology and electrochemical sensors has sparked a paradigm shift in the landscape of point-of-care (POC) diagnostics. This review explores the dynamic convergence between CRISPR and electrochemical sensing, elucidating their roles in rapid and precise biosensing platforms. CRISPR, renowned for its remarkable precision in genome editing and programmability capability, has found a novel application in conjunction with electrochemical sensors, promising highly sensitive and specific detection of nucleic acids and biomarkers associated with diverse diseases. This article navigates through fundamental principles, research developments, and applications of CRISPR-based electrochemical sensors, highlighting their potential to revolutionize healthcare accessibility and patient outcomes. In addition, some key points and challenges regarding applying CRISPR-powered electrochemical sensors in real POC settings are presented. By discussing recent advancements and challenges in this interdisciplinary field, this review evaluates the potential of these innovative sensors as an alternative for decentralized, rapid, and accurate POC testing, offering some insights into their applications across clinical scenarios and their impact on the future of diagnostics.


Assuntos
Técnicas Biossensoriais , Técnicas Eletroquímicas , Técnicas Biossensoriais/métodos , Humanos , Técnicas Eletroquímicas/métodos , Sistemas CRISPR-Cas/genética , Testes Imediatos , Sistemas Automatizados de Assistência Junto ao Leito
2.
Chemosphere ; 352: 141479, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38367874

RESUMO

The integration of conducting polymers (CPs) with metal-organic frameworks (MOFs) has arisen as a dynamic and innovative approach to overcome some intrinsic limitations of both materials, representing a transformative method to address the pressing need for high-performance environmental monitoring tools. MOFs, with their intricate structures and versatile functional groups, provide tuneable porosity and an extensive surface area, facilitating the selective adsorption of target analytes. Conversely, CPs, characterized by their exceptional electrical conductivity and redox properties, serve as proficient signal transducers. By combining these two materials, a novel class of hybrid materials emerges, capitalizing on the unique attributes of both components. These MOF/CP hybrids exhibit heightened sensitivity, selectivity, and adaptability, making them primordial in detecting and quantifying environmental contaminants. This review examines the synergy between MOFs and CPs, highlighting recent advancements, challenges, and prospects, thus offering a promising solution for developing advanced functional materials with tailored properties and multifunctionality to be applied in electrochemical sensors for environmental monitoring.


Assuntos
Estruturas Metalorgânicas , Polímeros , Adsorção , Condutividade Elétrica , Monitoramento Ambiental
3.
Mikrochim Acta ; 189(8): 278, 2022 07 13.
Artigo em Inglês | MEDLINE | ID: mdl-35829918

RESUMO

An electrochemical device using copper-based metalorganic franmeworks (MOF) associated with reduced graphene oxide to improve the charge transfer, stability, and adherence of the structures on the surface of the electrodes was developed. The syntheses of these materials were confirmed using scanning electron microscopy, thermogravimetric analysis, X-ray diffraction, Fourier transform infrared and Raman spectroscopy. For the first time, this type of sensor was applied to a systematic study to understand the action mechanism of MOFs and reduced graphene oxide in the electrochemical detection of paraquat pesticide. Under optimized conditions, paraquat was detected in standard solutions by differential pulse voltammetry (- 0.8 to - 0.3 V vs Ag/AgCl), achieving a linear response range between 0.30 and 5.00 µmol L-1. The limits of detection and quantification were 50.0 nmol L-1 and 150.0 nmol L-1, respectively. We assessed the accuracy of the proposed device to determine paraquat in water and human blood serum samples by recovery study, obtaining recovery values ranging from 98 to 104%. Furthermore, the selectivity of the proposed electrode for paraquat detection was evaluated against various interferences, demonstrating their promising application in environmental analysis.


Assuntos
Estruturas Metalorgânicas , Cobre/química , Técnicas Eletroquímicas/métodos , Eletrodos , Grafite , Humanos , Limite de Detecção , Estruturas Metalorgânicas/química , Paraquat
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA