Mol Ther ; 2024 May 24.
Artigo em Inglês | MEDLINE | ID: mdl-38796702

RESUMO

Positron emission tomography (PET) reporter systems are a valuable means of estimating the level of expression of a transgene in vivo. For example, the safety and efficacy of gene therapy approaches for the treatment of neurological and neuropsychiatric disorders could be enhanced via the monitoring of exogenous gene expression levels in the brain. The present study evaluated the ability of a newly developed PET reporter system [18F]fluoroestradiol ([18F]FES) and the estrogen receptor-based PET reporter ChRERα, to monitor expression levels of a small hairpin RNA (shRNA) designed to suppress choline acetyltransferase (ChAT) expression in rhesus monkey brain. The ChRERα gene and shRNA were expressed from the same transcript via lentivirus injected into monkey striatum. In two monkeys that received injections of viral vector, [18F]FES binding increased by 70% and 86% at the target sites compared with pre-injection, demonstrating that ChRERα expression could be visualized in vivo with PET imaging. Post-mortem immunohistochemistry confirmed that ChAT expression was significantly suppressed in regions in which [18F]FES uptake was increased. The consistency between PET imaging and immunohistochemical results suggests that [18F]FES and ChRERα can serve as a PET reporter system in rhesus monkey brain for in vivo evaluation of the expression of potential therapeutic agents, such as shRNAs.

2.
Methods ; 185: 110-119, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-32006678

RESUMO

This work demonstrates how computational and physical modelling of the positron emission tomography (PET) image acquisition process for a state-of-the-art integrated PET and magnetic resonance imaging (PET-MR) system can produce images comparable to the manufacturer. The GE SIGNA PET/MR scanner is manufactured by General Electric and has time-of-flight (TOF) capabilities of about 390 ps. All software development took place in the Software for Tomographic Image Reconstruction (STIR: http://stir.sf.net) library, which is a widely used open source software to reconstruct data as exported from emission tomography scanners. The new software developments will be integrated into STIR, providing the opportunity for researchers worldwide to establish and expand their image reconstruction methods. Furthermore, this work is of particular significance as it provides the first validation of TOF PET image reconstruction for real scanner datasets using the STIR library. This paper presents the methodology, analysis, and critical issues encountered in implementing an independent reconstruction software package. Acquired PET data were processed via several appropriate algorithms which are necessary to produce an accurate and precise quantitative image. This included mathematical, physical and anatomical modelling of the patient and simulation of various aspects of the acquisition. These included modelling of random coincidences using 'singles' rates per crystals, detector efficiencies and geometric effects. Attenuation effects were calculated by using the STIR's attenuation correction model. Modelling all these effects within the system matrix allowed the reconstruction of PET images which demonstrates the metabolic uptake of the administered radiopharmaceutical. These implementations were validated using measured phantom and clinical datasets. The developments are tested using the ordered subset expectation maximisation (OSEM) and the more recently proposed kernelised expectation maximisation (KEM) algorithm which incorporates anatomical information from MR images into PET reconstruction.


Assuntos
Imageamento por Ressonância Magnética/métodos , Tomografia por Emissão de Pósitrons/métodos , Software , Simulação por Computador , Humanos , Processamento de Imagem Assistida por Computador , Modelos Biológicos , Modelos Teóricos , Fibrose Pulmonar/diagnóstico por imagem
3.
Phys Med Biol ; 64(3): 035004, 2019 01 22.
Artigo em Inglês | MEDLINE | ID: mdl-30566915

RESUMO

In this paper, we describe the implementation of support for time-of-flight (TOF) positron emission tomography (PET) for both listmode and sinogram data in the open source software for tomographic image reconstruction (STIR). We provide validation and performance characterization using simulated data from the open source GATE Monte Carlo toolbox, with TOF configurations spanning from 81.2 to 209.6 ps. The coincidence detector resolution was corrected for the timing resolution deterioration due to the contribution of the crystal length. Comparison between the reconstruction of listmode and sinogram data demonstrated good agreement in both TOF and non-TOF cases in terms of relative absolute error. To reduce the reconstruction time, we assessed the truncation of the TOF kernel along lines-of-response (LOR). Rejection of LOR elements beyond four times the TOF standard deviation provides significant acceleration of [Formula: see text] [Formula: see text] without compromising the image quality. Further narrowing of the kernel can provide extra time reduction but with the gradual introduction of error in the reconstructed images. As expected, TOF reconstruction performs better than non-TOF in terms of both contrast-recovery-coefficient (CRC) and signal-to-noise ratio (SNR). CRC achieves convergence faster with TOF, at lower noise levels. SNR with TOF was superior for early iterations, but with quick deterioration. Higher timing resolution further improved reconstruction performance, while TOF bin mashing was shown to have only a small impact on reconstructed images.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Tomografia por Emissão de Pósitrons , Software , Algoritmos , Humanos , Método de Monte Carlo , Razão Sinal-Ruído
4.
EJNMMI Phys ; 5(1): 34, 2018 Dec 05.
Artigo em Inglês | MEDLINE | ID: mdl-30519974

RESUMO

BACKGROUND: Positron emission tomography (PET) imaging has a wide applicability in oncology, cardiology and neurology. However, a major drawback when imaging very active regions such as the bladder is the spill-in effect, leading to inaccurate quantification and obscured visualisation of nearby lesions. Therefore, this study aims at investigating and correcting for the spill-in effect from high-activity regions to the surroundings as a function of activity in the hot region, lesion size and location, system resolution and application of post-filtering using a recently proposed background correction technique. This study involves analytical simulations for the digital XCAT2 phantom and validation acquiring NEMA phantom and patient data with the GE Signa PET/MR scanner. Reconstructions were done using the ordered subset expectation maximisation (OSEM) algorithm. Dedicated point-spread function (OSEM+PSF) and a recently proposed background correction (OSEM+PSF+BC) were incorporated into the reconstruction for spill-in correction. The standardised uptake values (SUV) were compared for all reconstruction algorithms. RESULTS: The simulation study revealed that lesions within 15-20 mm from the hot region were predominantly affected by the spill-in effect, leading to an increased bias and impaired lesion visualisation within the region. For OSEM, lesion SUVmax converged to the true value at low bladder activity, but as activity increased, there was an overestimation as much as 19% for proximal lesions (distance around 15-20 mm from the bladder edge) and 2-4% for distant lesions (distance larger than 20 mm from the bladder edge). As bladder SUV increases, the % SUV change for proximal lesions is about 31% and 6% for SUVmax and SUVmean, respectively, showing that the spill-in effect is more evident for the SUVmax than the SUVmean. Also, the application of post-filtering resulted in up to 65% increment in the spill-in effect around the bladder edges. For proximal lesions, PSF has no major improvement over OSEM because of the spill-in effect, coupled with the blurring effect by post-filtering. Within two voxels around the bladder, the spill-in effect in OSEM is 42% (32%), while for OSEM+PSF, it is 31% (19%), with (and without) post-filtering, respectively. But with OSEM+PSF+BC, the spill-in contribution from the bladder was relatively low (below 5%, either with or without post-filtering). These results were further validated using the NEMA phantom and patient data for which OSEM+PSF+BC showed about 70-80% spill-in reduction around the bladder edges and increased contrast-to-noise ratio up to 36% compared to OSEM and OSEM+PSF reconstructions without post-filtering. CONCLUSION: The spill-in effect is dependent on the activity in the hot region, lesion size and location, as well as post-filtering; and this is more evident in SUVmax than SUVmean. However, the recently proposed background correction method facilitates stability in quantification and enhances the contrast in lesions with low uptake.