Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 22
Filtrar
1.
Eur J Radiol ; 168: 111121, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37806195

RESUMO

PURPOSE: To assess whether image quality differences between SECT (single-energy CT) and DECT (dual-energy CT 70 keV) with equivalent radiation doses result in altered detection and characterization accuracy of liver metastases when using deep learning image reconstruction (DLIR), and whether DECT spectral curve usage improves accuracy of indeterminate lesion characterization. METHODS: In this prospective Health Insurance Portability and Accountability Act-compliant study (March through August 2022), adult men and non-pregnant adult women with biopsy-proven colorectal cancer and liver metastases underwent SECT (120 kVp) and a DECT (70 keV) portovenous abdominal CT scan using DLIR in the same breath-hold (Revolution CT ES; GE Healthcare). Participants were excluded if consent could not be obtained, if there were nonequivalent radiation doses between the two scans, or if the examination was cancelled/rescheduled. Three radiologists independently performed lesion detection and characterization during two separate sessions (SECT DLIRmedium and DECT DLIRhigh) as well as reported lesion confidence and overall image quality. Hounsfield units were measured. Spectral HU curves were provided for any lesions rated as indeterminate. McNemar's test was used to test the marginal homogeneity in terms of diagnostic sensitivity, accuracy and lesion detection. A generalized estimating equation method was used for categorical outcomes. RESULTS: 30 participants (mean age, 58 years ± 11, 21 men) were evaluated. Mean CTDIvol was 34 mGy for both scans. 141 lesions (124 metastases, 17 benign) with a mean size of 0.8 cm ± 0.3 cm were identified. High scores for image quality (scores of 4 or 5) were not significantly different between DECT (N = 71 out of 90 total scores from the three readers) and SECT (N = 62) (OR, 2.01; 95% CI:0.89, 4.57; P = 0.093). Equivalent image noise to SECT DLIRmed (HU SD 10 ± 2) was obtained with DECT DLIRhigh (HU SD 10 ± 3) (P = 1). There was no significant difference in lesion detection between DECT and SECT (140/141 lesions) (99.3%; 95% CI:96.1%, 100%).The mean lesion confidence scores by each reader were 4.2 ± 1.3, 3.9 ± 1.0, and 4.8 ± 0.8 for SECT and 4.1 ± 1.4, 4.0 ± 1.0, and 4.7 ± 0.8 for DECT (odds ratio [OR], 0.83; 95% CI: 0.62, 1.11; P = 0.21). Small lesion (≤5mm) characterization accuracy on SECT and DECT was 89.1% (95% CI:76.4%, 96.4%; 41/46) and 84.8% (71.1%, 93.7%; 39/46), respectively (P = 0.41). Use of spectral HU lesion curves resulted in 34 correct changes in characterizations and no mischaracterizations. CONCLUSION: DECT required a higher strength of DLIR to obtain equivalent noise compared to SECT DLIR. At equivalent radiation doses and image noise, there was no significant difference in subjective image quality or observer lesion performance between DECT (70 keV) and SECT. However, DECT spectral HU curves of indeterminate lesions improved characterization.


Assuntos
Aprendizado Profundo , Neoplasias Hepáticas , Masculino , Adulto , Humanos , Feminino , Pessoa de Meia-Idade , Tomografia Computadorizada por Raios X/métodos , Neoplasias Hepáticas/diagnóstico por imagem , Abdome , Estudos Prospectivos , Doses de Radiação
3.
Clin Imaging ; 86: 13-19, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35313164

RESUMO

PURPOSE: The purpose of this retrospective study was to evaluate the quality of outside hospital imaging and associated reports submitted to us for reinterpretation related to clinical care at our tertiary cancer center. We compared the initial study interpretations to that of interpretations performed by subspecialty-trained abdominal radiologists at our center and whether this resulted in a change in inpatient treatment. MATERIALS AND METHODS: We performed an institutional review board-approved retrospective single-institution study of 915 consecutive outside computed tomography (CT) and magnetic resonance (MR) abdominal imaging studies that had been submitted to our institution between August 1, 2020 and November 30, 2020. The assessed parameters included the quality and accuracy of the report, the technical quality of the imaging compared to that at our institution, the appropriateness of the imaging for staging or restaging, usage of oral and IV contrast, and CT slice thickness. Clinical notes, pathologic findings, and subsequent imaging were used to establish an accurate diagnosis and determine the effect on clinical treatment. Discrepancies between the initial and secondary interpretations were identified independently by a panel of radiologists to assess changes in treatment. The impact of discrepancies on treatment was evaluated based on current treatment guidelines. RESULTS: Of 744 CT (81%) and 171 MR (19%) outside imaging studies, 65% had suboptimal quality compared to the images at our institution, and 31% were inappropriate for oncological care purposes. Only 21% of CT studies had optimal slice thickness of <3 mm. Of 375 (41%) outside reports, 131 (34%) had discrepancies between secondary and initial interpretations. Of the 88 confirmed discrepant studies, 42 patients (48%) had a change in treatment based on the secondary interpretation. CONCLUSIONS: Imaging studies from outside institutions have variable image quality and are often inadequate for oncologic imaging. The secondary interpretations by subspecialty-trained radiologists resulted in treatment change.


Assuntos
Institutos de Câncer , Neoplasias , Humanos , Neoplasias/diagnóstico por imagem , Neoplasias/terapia , Variações Dependentes do Observador , Radiologistas , Encaminhamento e Consulta , Estudos Retrospectivos
4.
Radiology ; 303(1): 90-98, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-35014900

RESUMO

Background Assessment of liver lesions is constrained as CT radiation doses are lowered; evidence suggests deep learning reconstructions mitigate such effects. Purpose To evaluate liver metastases and image quality between reduced-dose deep learning image reconstruction (DLIR) and standard-dose filtered back projection (FBP) contrast-enhanced abdominal CT. Materials and Methods In this prospective Health Insurance Portability and Accountability Act-compliant study (September 2019 through April 2021), participants with biopsy-proven colorectal cancer and liver metastases at baseline CT underwent standard-dose and reduced-dose portal venous abdominal CT in the same breath hold. Three radiologists detected and characterized lesions at standard-dose FBP and reduced-dose DLIR, reported confidence, and scored image quality. Contrast-to-noise ratios for liver metastases were recorded. Summary statistics were reported, and a generalized linear mixed model was used. Results Fifty-one participants (mean age ± standard deviation, 57 years ± 13; 31 men) were evaluated. The mean volume CT dose index was 65.1% lower with reduced-dose CT (12.2 mGy) than with standard-dose CT (34.9 mGy). A total of 161 lesions (127 metastases, 34 benign lesions) with a mean size of 0.7 cm ± 0.3 were identified. Subjective image quality of reduced-dose DLIR was superior to that of standard-dose FBP (P < .001). The mean contrast-to-noise ratio for liver metastases of reduced-dose DLIR (3.9 ± 1.7) was higher than that of standard-dose FBP (3.5 ± 1.4) (P < .001). Differences in detection were identified only for lesions 0.5 cm or smaller: 63 of 65 lesions detected with standard-dose FBP (96.9%; 95% CI: 89.3, 99.6) and 47 lesions with reduced-dose DLIR (72.3%; 95% CI: 59.8, 82.7). Lesion accuracy with standard-dose FBP and reduced-dose DLIR was 80.1% (95% CI: 73.1, 86.0; 129 of 161 lesions) and 67.1% (95% CI: 59.3, 74.3; 108 of 161 lesions), respectively (P = .01). Lower lesion confidence was reported with a reduced dose (P < .001). Conclusion Deep learning image reconstruction (DLIR) improved CT image quality at 65% radiation dose reduction while preserving detection of liver lesions larger than 0.5 cm. Reduced-dose DLIR demonstrated overall inferior characterization of liver lesions and reader confidence. Clinical trial registration no. NCT03151564 © RSNA, 2022 Online supplemental material is available for this article.


Assuntos
Aprendizado Profundo , Neoplasias Hepáticas , Algoritmos , Feminino , Humanos , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/secundário , Masculino , Estudos Prospectivos , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos
5.
Abdom Radiol (NY) ; 47(1): 378-398, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34664097

RESUMO

This article reviews the relevant anatomy, imaging features on computed tomography, magnetic resonance imaging, and management of common processes involving the sciatic foramen. The anatomy of the sciatic foramen is complex and provides an important conduit between the pelvis, gluteus, and lower extremity. This paper reviewed the anatomy, common pathologies, and imaging features of this region including trauma, infection, nerve entrapment, tumor spread, hernia, and vascular anomaly.


Assuntos
Pelve , Nervo Isquiático , Hérnia , Humanos , Imageamento por Ressonância Magnética/métodos , Nervo Isquiático/anatomia & histologia , Tomografia Computadorizada por Raios X
6.
Cureus ; 13(7): e16568, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-34430170

RESUMO

The main objective of the article is to describe the changes in managing the peer learning system in the Department of Abdominal Imaging at our institution during the pandemic and its restrictions. The pandemic poses diverse challenges to academic institutions across the country including radiology education and peer learning. The health sector in some areas of the country has been stretched by the number of coronavirus disease 2019 (COVID-19) patients. In March 2020, our institution cancelled all in-person conferences as per guidelines from the Center of Disease Control and Prevention to mitigate the spread of COVID-19 and the conferences were shifted to virtual platforms. Our recent peer learning approach allowed us to practice appropriate social distancing while following the institutional and national guidelines with minimal disruption. Other institutions that are facing similar challenges can adopt or modify our framework of a successful and efficient virtual peer learning process.

7.
Clin Imaging ; 71: 69-76, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33171370

RESUMO

OBJECTIVES: To study the relationship of the 3rd segment of the vertebral artery to the posterior arch of the atlas in patients with occipitalized atlas, using CT angiography. METHODS: A retrospective study of 25 cases with complete or partially occipitalized atlas who underwent CT angiography evaluation. Fifty vertebral arteries were analyzed in relation to the respective/related half of the posterior arch of the atlas. RESULTS: Out of 50 vertebral arteries, 35 (70%) were anomalous; 31 (62%) traversed though bony canal between the fused occiput and atlas, and 4 (8%) coursed between C1 and C2 (C2 segmental type of vertebral artery). Except one, all anomalous vertebral arteries were associated with a fused corresponding side of posterior arch of atlas. CONCLUSION: The V3 portion of the vertebral artery assumes an anomalous course at the craniovertebral junction in most cases of occipitalized atlas, and this is strongly determined by the fusion status of the posterior arch of the atlas. Aberrations in its course are still seen despite expectations based on this fusion status. Preprocedural CT Angiography provides accurate information of its course to prevent iatrogenic VA injuries. ADVANCES IN KNOWLEDGE: CT Angiography should be performed before any procedures at the craniovertebral junction in cases of occipitalized atlas to prevent iatrogenic, potentially catastrophic injuries to vertebral artery due to its anomalous course in most of these cases. There are very few such studies in the literature, none in radiology literature. We also describe some rare cases, including a case never described in any literature.


Assuntos
Atlas Cervical , Artéria Vertebral , Atlas Cervical/diagnóstico por imagem , Angiografia por Tomografia Computadorizada , Humanos , Radiografia , Estudos Retrospectivos , Artéria Vertebral/diagnóstico por imagem
8.
J Comput Assist Tomogr ; 44(6): 911-913, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32976270

RESUMO

OBJECTIVE: The aim of this study was to optimize chest port contrast injections using stepwise improvements. METHODS: Ex vivo injections were tested. Two hundred scans using power port injections were then evaluated. RESULTS: The highest flow rate was achieved using a 19G access needle, larger diameter tubing, and warmed contrast.The mean injection rates in baseline and postimprovement groups were 2.7 ± 0.4 and 4.8 ± 0.4 mL/s, respectively (P < .0001). CONCLUSION: Component optimization of the port apparatus can maximize contrast flow rates.


Assuntos
Cateterismo Venoso Central/instrumentação , Cateteres de Demora , Meios de Contraste/administração & dosagem , Intensificação de Imagem Radiográfica/métodos , Tomografia Computadorizada por Raios X , Adulto , Idoso , Idoso de 80 Anos ou mais , Desenho de Equipamento , Feminino , Humanos , Injeções , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Adulto Jovem
9.
Clin Lymphoma Myeloma Leuk ; 20(8): 533-541, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32291233

RESUMO

INTRODUCTION: Early stage Hodgkin lymphoma (ESHL) is highly curable; however, 10% to 15% of patients experience relapse. We examined the utilization of follow-up imaging for patients with ESHL who achieved a metabolic complete response after upfront therapy. MATERIALS AND METHODS: The records of adult patients treated at a single institution between 2003 and 2014 were reviewed. Positron emission tomography-computed tomography (PET-CT) and CT scan frequency was quantified during the 2 years following treatment and subsequent visits beyond 2 years. RESULTS: The study cohort contained 179 patients. The median age was 31 years; bulky disease was present in 30%. ABVD (doxorubicin, bleomycin, vinblastine, and dacarbazine) or AVD (doxorubicin, vinblastine, and dacarbazine) was given in 97%; 75% received radiation therapy. At a median follow-up of 6.9 years, the 5-year progression-free and overall survival rates were 93.7% and 98.1%, respectively. Relapse occurred in 5% (n = 9) of patients at a median of 9.1 months (range, 4.6-27.2 months) from therapy. Two patients presented with symptoms prompting imaging in follow-up. Within 2 years after therapy, 376 PET-CT scans and 3325 CT scans were performed, yielding an average of 2.1 PET-CTs and 18.6 CTs per patient. Of the initial 179 patients, 113 had follow-up conducted beyond 2 years post-therapy; an average of 2.7 PET-CTs and 33.2 CTs were performed. In the 2-year post-therapy period, 463 scans were performed per relapse detected. CONCLUSION: In this cohort of patients with ESHL who responded completely to frontline therapy, the relapse rate was low. Routine imaging surveillance lacks clinical benefit in this patient population.


Assuntos
Doença de Hodgkin/diagnóstico por imagem , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Doença de Hodgkin/mortalidade , Humanos , Masculino , Pessoa de Meia-Idade , Recidiva Local de Neoplasia , Estadiamento de Neoplasias , Intervalo Livre de Progressão , Adulto Jovem
10.
AJR Am J Roentgenol ; 215(1): 50-57, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32286872

RESUMO

OBJECTIVE. The purpose of this study was to perform quantitative and qualitative evaluation of a deep learning image reconstruction (DLIR) algorithm in contrast-enhanced oncologic CT of the abdomen. MATERIALS AND METHODS. Retrospective review (April-May 2019) of the cases of adults undergoing oncologic staging with portal venous phase abdominal CT was conducted for evaluation of standard 30% adaptive statistical iterative reconstruction V (30% ASIR-V) reconstruction compared with DLIR at low, medium, and high strengths. Attenuation and noise measurements were performed. Two radiologists, blinded to examination details, scored six categories while comparing reconstructions for overall image quality, lesion diagnostic confidence, artifacts, image noise and texture, lesion conspicuity, and resolution. RESULTS. DLIR had a better contrast-to-noise ratio than 30% ASIR-V did; high-strength DLIR performed the best. High-strength DLIR was associated with 47% reduction in noise, resulting in a 92-94% increase in contrast-to-noise ratio compared with that of 30% ASIR-V. For overall image quality and image noise and texture, DLIR scored significantly higher than 30% ASIR-V with significantly higher scores as DLIR strength increased. A total of 193 lesions were identified. The lesion diagnostic confidence, conspicuity, and artifact scores were significantly higher for all DLIR levels than for 30% ASIR-V. There was no significant difference in perceived resolution between the reconstruction methods. CONCLUSION. Compared with 30% ASIR-V, DLIR improved CT evaluation of the abdomen in the portal venous phase. DLIR strength should be chosen to balance the degree of desired denoising for a clinical task relative to mild blurring, which increases with progressively higher DLIR strengths.


Assuntos
Aprendizado Profundo , Neoplasias do Sistema Digestório/diagnóstico por imagem , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Radiografia Abdominal , Neoplasias Torácicas/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Adulto , Idoso , Idoso de 80 Anos ou mais , Meios de Contraste , Feminino , Humanos , Iohexol , Masculino , Pessoa de Meia-Idade , Doses de Radiação , Estudos Retrospectivos
11.
Abdom Radiol (NY) ; 45(4): 917-927, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-31093730

RESUMO

Adrenal hyperplasia is non-malignant enlargement of the adrenal glands, which is often bilateral. It can be incidental or related to indolent disease process and may be related to benign or malignant etiologies causing biochemical alterations in the hypothalamic-pituitary-adrenal axis which controls steroidogenesis and in particular cortisol production. Clinical significance of the adrenal hyperplasia is variable ranging from asymptomatic finding to serious manifestations of Cushing syndrome. This is often associated with anatomical changes in the adrenal glands, which typically manifests as diffuse and sometimes nodular enlargement of the adrenal glands radiologically. Approaching adrenal hyperplasia requires careful clinical and biochemical evaluation in correlation with imaging review to differentiate ACTH-dependent and ACTH-independent etiologies. CT is the primary modality of choice for adult adrenal imaging owing to reproducibility, temporal and spatial resolution and broader access, while MRI often serves a complimentary role. Ultrasound and MRI are most commonly used in pediatric cases to evaluate congenital adrenal hyperplasia. This article will discuss the clinical presentation and imaging features of different types and mimics of adrenal cortical hyperplasia.


Assuntos
Doenças das Glândulas Suprarrenais/diagnóstico por imagem , Córtex Suprarrenal/diagnóstico por imagem , Córtex Suprarrenal/patologia , Testes de Função do Córtex Suprarrenal , Doenças das Glândulas Suprarrenais/patologia , Diagnóstico Diferencial , Humanos , Hiperplasia/diagnóstico por imagem , Hiperplasia/patologia , Achados Incidentais
12.
J Comput Assist Tomogr ; 43(1): 155-162, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30211799

RESUMO

OBJECTIVE: This study aimed to evaluate the quality of enhancement and solid-organ lesion depiction using weight-based intravenous (IV) contrast dosing calculated by injector software versus fixed IV contrast dose in oncologic abdominal computed tomographic (CT) examinations. METHODS: This institutional review board-exempt retrospective cohort study included 134 patients who underwent single-phase abdominal CT before and after implementation of weight-based IV contrast injector software. Patient weight, height, body mass index, and body surface area were determined. Two radiologists qualitatively assessed examinations (4 indicating markedly superior to -4 indicating markedly inferior), and Hounsfield unit measurements were performed. RESULTS: Enhancement (estimated mean, -0.05; 95% confidence interval [CI], -0.19 to 0.09; P = 0.46) and lesion depiction (estimated mean, -0.01; 95% CI, -0.10 to 0.07; P = 0.79) scores did not differ between CT examinations using weight-based IV contrast versus fixed IV contrast dosing when a minimum of 38.5 g of iodine was used. However, the scores using weight-based IV contrast dosing were lower when the injector software calculated and delivered less than 38.5 g of iodine (estimated mean, -0.81; 95% CI, -1.06 to -0.56; P < 0.0001). There were no significant differences in measured Hounsfield units between the CT examinations using weight-based IV contrast dosing versus fixed IV contrast dosing. CONCLUSIONS: Oncologic CT image quality was maintained or improved with weight-based IV contrast dosing using injector software when using a minimum amount of 38.5 g of iodine.


Assuntos
Cavidade Abdominal/diagnóstico por imagem , Peso Corporal , Meios de Contraste/administração & dosagem , Neoplasias/diagnóstico por imagem , Intensificação de Imagem Radiográfica/métodos , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos de Coortes , Relação Dose-Resposta a Droga , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Estudos Retrospectivos , Atenção Terciária à Saúde , Adulto Jovem
13.
Radiology ; 290(2): 400-409, 2019 02.
Artigo em Inglês | MEDLINE | ID: mdl-30480489

RESUMO

Purpose To evaluate colorectal cancer hepatic metastasis detection and characterization between reduced radiation dose (RD) and standard dose (SD) contrast material-enhanced CT of the abdomen and to qualitatively compare between filtered back projection (FBP) and iterative reconstruction algorithms. Materials and Methods In this prospective study (from May 2017 through November 2017), 52 adults with biopsy-proven colorectal cancer and suspected hepatic metastases at baseline CT underwent two portal venous phase CT scans: SD and RD in the same breath hold. Three radiologists, blinded to examination details, performed detection and characterization of 2-15-mm lesions on the SD FBP and RD adaptive statistical iterative reconstruction (ASIR)-V 60% series images. Readers assessed overall image quality and lesions between SD FBP and seven different iterative reconstructions. Two nonblinded consensus reviewers established the reference standard using the picture archiving and communication system lesion marks of each reader, multiple comparison examinations, and clinical data. Results RD CT resulted in a mean dose reduction of 54% compared with SD. Of the 260 lesions (233 metastatic, 27 benign), 212 (82%; 95% confidence interval [CI]: 76%, 86%) were detected with RD CT, whereas 252 (97%; 95% CI: 94%, 99%) were detected with SD (P < .001); per-lesion sensitivity was 79% (95% CI: 74%, 84%) and 94% (95% CI: 90%, 96%) (P < .001), respectively. Mean qualitative scores ranked SD images as higher quality than RD series images, and ASIR-V ranked higher than ASIR and Veo 3.0. Conclusion CT evaluation of colorectal liver metastases is compromised with modest radiation dose reduction, and the use of iterative reconstructions could not maintain observer performance. © RSNA, 2018.


Assuntos
Neoplasias Colorretais/patologia , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/secundário , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Fígado/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Doses de Radiação , Adulto Jovem
14.
J Comput Assist Tomogr ; 42(2): 184-190, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-28806318

RESUMO

OBJECTIVE: The purpose of this study was to compare abdominopelvic computed tomography images reconstructed with adaptive statistical iterative reconstruction-V (ASIR-V) with model-based iterative reconstruction (Veo 3.0), ASIR, and filtered back projection (FBP). METHODS AND MATERIALS: Abdominopelvic computed tomography scans for 36 patients (26 males and 10 females) were reconstructed using FBP, ASIR (80%), Veo 3.0, and ASIR-V (30%, 60%, 90%). Mean ± SD patient age was 32 ± 10 years with mean ± SD body mass index of 26.9 ± 4.4 kg/m. Images were reviewed by 2 independent readers in a blinded, randomized fashion. Hounsfield unit, noise, and contrast-to-noise ratio (CNR) values were calculated for each reconstruction algorithm for further comparison. Phantom evaluation of low-contrast detectability (LCD) and high-contrast resolution was performed. RESULTS: Adaptive statistical iterative reconstruction-V 30%, ASIR-V 60%, and ASIR 80% were generally superior qualitatively compared with ASIR-V 90%, Veo 3.0, and FBP (P < 0.05). Adaptive statistical iterative reconstruction-V 90% showed superior LCD and had the highest CNR in the liver, aorta, and, pancreas, measuring 7.32 ± 3.22, 11.60 ± 4.25, and 4.60 ± 2.31, respectively, compared with the next best series of ASIR-V 60% with respective CNR values of 5.54 ± 2.39, 8.78 ± 3.15, and 3.49 ± 1.77 (P <0.0001). Veo 3.0 and ASIR 80% had the best and worst spatial resolution, respectively. CONCLUSIONS: Adaptive statistical iterative reconstruction-V 30% and ASIR-V 60% provided the best combination of qualitative and quantitative performance. Adaptive statistical iterative reconstruction 80% was equivalent qualitatively, but demonstrated inferior spatial resolution and LCD.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Radiografia Abdominal/métodos , Tomografia Computadorizada por Raios X/métodos , Adulto , Algoritmos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Estudos Retrospectivos , Adulto Jovem
15.
Br J Radiol ; 90(1077): 20170188, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28707531

RESUMO

OBJECTIVE: To qualitatively and quantitatively compare abdominal CT images reconstructed with a newversion of model-based iterative reconstruction (Veo 3.0; GE Healthcare Waukesha, WI) utilizing varied presetsof resolution preference, noise reduction and slice optimization. METHODS: This retrospective study was approved by our Institutional Review Board and was Health Insurance Portability and Accountability Act compliant. The raw datafrom 30 consecutive patients who had undergone CT abdomen scanning were used to reconstructfour clinical presets of 3.75mm axial images using Veo 3.0: 5% resolution preference (RP05n), 5%noise reduction (NR05) and 40% noise reduction (NR40) with new 3.75mm "sliceoptimization," as well as one set using RP05 with conventional 0.625mm "slice optimization" (RP05c). The images were reviewed by two independent readers in a blinded, randomized manner using a 5-point Likert scale as well as a 5-point comparative scale. Multiple two-dimensional circular regions of interest were defined for noise and contrast-to-noise ratio measurements. Line profiles were drawn across the 7 lp cm-1 bar pattern of the Catphan 600 phantom for evaluation of spatial resolution. RESULTS: The NR05 image set was ranked as the best series in overall image quality (mean difference inrank 0.48, 95% CI [0.081-0.88], p = 0.01) and with specific reference to liver evaluation (meandifference 0.46, 95% CI [0.030-0.89], p = 0.03), when compared with the secondbest series ineach category. RP05n was ranked as the best for bone evaluation. NR40 was ranked assignificantly inferior across all assessed categories. Although the NR05 and RP05c image setshad nearly the same contrast-to-noise ratio and spatial resolution, NR05 was generally preferred. Image noise and spatial resolution increased along a spectrum with RP05n the highest and NR40the lowest. Compared to RP05n, the average noise was 21.01% lower for NR05, 26.88%lower for RP05c and 50.86% lower for NR40. CONCLUSION: Veo 3.0 clinical presets allow for selection of image noise and spatial resolution balance; for contrast-enhanced CT evaluation of the abdomen, the 5% noise reduction preset with 3.75 mm slice optimization (NR05) was generally ranked superior qualitatively and, relative to other series, was in the middle of the spectrum with reference to image noise and spatial resolution. Advances in knowledge: To our knowledge, this is the first study of Veo 3.0 noise reduction presets and varied slice optimization. This study provides insight into the behaviour of slice optimization and documents the degree of noise reduction and spatial resolution changes that users can expect across various Veo 3.0 clinical presets. These results provide important parameters to guide preset selection for both clinical and research purposes.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Radiografia Abdominal/métodos , Tomografia Computadorizada por Raios X/métodos , Adulto , Estudos de Avaliação como Assunto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Ruído , Reprodutibilidade dos Testes , Estudos Retrospectivos , Razão Sinal-Ruído , Adulto Jovem
16.
Br J Radiol ; 90(1079): 20170330, 2017 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-28707538

RESUMO

Adrenal cortical hyperplasia manifests radiologically as a non-malignant growth, or enlargement, of the adrenal glands, specifically the cortex, although the cortex cannot be definitively identified by conventional imaging. Controlled by the pituitary gland, the adrenal cortex drives critical processes, such as the production of cortisol, mineralocorticoid and sex hormones. Any disruption in the multiple enzymes and hormones involved in these pathways may cause serious or life-threatening symptoms, often associated with anatomical changes in the adrenal glands. Diagnosis and treatment of adrenal cortical hyperplasia requires a thorough clinical evaluation. As imaging has become more robust so has its role in the diagnosis and treatment of adrenal conditions. CT has been the primary modality for adrenal imaging owing to reproducibility, temporal and spatial resolution and broad access. MRI serves a complimentary role in adrenal imaging and can be used to further evaluate indeterminate CT findings or serve as an adjunct tool without the use of ionizing radiation. Ultrasound and fluoroscopy (genitography) are most commonly used in children and foetuses to evaluate congenital adrenal hyperplasia. This article will discuss the clinical presentation, laboratory workup and imaging features of adrenal cortical hyperplasia, both congenital and acquired.


Assuntos
Glândulas Suprarrenais/diagnóstico por imagem , Hiperplasia Suprarrenal Congênita/diagnóstico , Adolescente , Glândulas Suprarrenais/patologia , Hiperplasia Suprarrenal Congênita/classificação , Hiperplasia Suprarrenal Congênita/diagnóstico por imagem , Hiperplasia Suprarrenal Congênita/metabolismo , Hormônio Adrenocorticotrópico/sangue , Adulto , Síndrome de Cushing/diagnóstico , Diagnóstico Diferencial , Feminino , Humanos , Hiperplasia/classificação , Hiperplasia/diagnóstico por imagem , Hiperplasia/etiologia , Recém-Nascido , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Tamanho do Órgão , Hipersecreção Hipofisária de ACTH/diagnóstico , Esteroide 21-Hidroxilase , Tomografia Computadorizada por Raios X
17.
AJR Am J Roentgenol ; 209(1): 19-32, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-28639924

RESUMO

OBJECTIVE: Cushing syndrome (CS) is a constellation of clinical signs and symptoms resulting from chronic exposure to excess cortisol, either exogenous or endogenous. Exogenous CS is most commonly caused by administration of glucocorticoids. Endogenous CS is subdivided into two types: adrenocorticotropic hormone (ACTH) dependent and ACTH independent. CONCLUSION: Cushing disease, which is caused by a pituitary adenoma, is the most common cause of ACTH-dependent CS for which pituitary MRI can be diagnostic, with bilateral inferior petrosal sinus sampling useful in equivocal cases. In ectopic ACTH production, which is usually caused by a tumor in the thorax (e.g., small cell lung carcinoma, bronchial and thymic carcinoids, or medullary thyroid carcinoma) or abdomen (e.g., gastroenteropancreatic neuroendocrine tumors or pheochromocytoma), CT, MRI, and nuclear medicine tests are used for localizing the source of ACTH. In ACTH-independent CS, which is caused by various adrenal abnormalities, adrenal protocol CT or MRI is usually diagnostic.


Assuntos
Síndrome de Cushing/diagnóstico por imagem , Síndrome de Cushing/patologia , Diagnóstico por Imagem/métodos , Diagnóstico Diferencial , Humanos
18.
Abdom Radiol (NY) ; 42(11): 2760-2768, 2017 11.
Artigo em Inglês | MEDLINE | ID: mdl-28523416

RESUMO

PURPOSE: To compare studies with and without oral contrast on performance of multidetector computed tomography (CT) and the order to CT examination turnaround time in cancer patients presenting to the emergency department (ED). To the best of our knowledge, oral contrast utility has not previously been specifically assessed in cancer patients presenting to the emergency department. MATERIALS & METHODS: Retrospective review of CT abdomen examinations performed in oncology patients presenting to the emergency department during one month. CT examinations performed with and without oral contrast were rated by two consensus readers for degree of confidence and diagnostic ability. Correlations were assessed for primary cancer type, age, sex, chief complaint/examination indication, body mass index, intravenous contrast status, repeat CT examination within 4 weeks, and disposition. Turnaround times from order to the start of the CT examination were calculated. RESULTS: The studied group consisted of 267 patients (127 men and 140 women) with a mean age of 56 years and a mean body mass index of 27.8 kg/m2. One hundred sixty CT examinations were performed without oral contrast, and 107 CT examinations were performed with oral contrast. There was no significant difference between cases with oral contrast and cases without oral contrast in the number of cases rated as "improved confidence" (odds ratio [OR] 0.54, 95% confidence interval [CI] 0.23-1.31, P = 0.17), "improved diagnosis" (OR 0.58, 95% CI 0.20-1.64, P = 0.3), "impaired confidence" (OR 3.92, 95% CI 0.46-33.06, P = 0.21), or "impaired diagnosis" (OR 2.63, 95% CI 0.29-23.89, P = 0.39). The turnaround time in the group receiving oral contrast (mean, 141 min; standard deviation, 49.8 min) was significantly longer than that in the group not receiving oral contrast (mean, 109.2 min; standard deviation, 64.8 min) with a mean difference of 31.8 min (P < 0.0001). CONCLUSION: On the basis of our findings and prior studies, targeted rather than default use of oral contrast shows acceptable diagnostic ability in the emergency setting for oncology patients. Benefit from oral contrast use is suggested in scenarios such as suspected fistula/bowel leak/abscess, hypoattenuating peritoneal disease, prior bowel surgery such as gastric bypass, and the absence of intravenous contrast administration. Improvement through the use of targeted oral contrast administration also supports the emergency department need for prompt diagnosis and disposition.


Assuntos
Meios de Contraste/administração & dosagem , Serviço Hospitalar de Emergência , Neoplasias/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Administração Oral , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
19.
J Comput Assist Tomogr ; 41(1): 67-74, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-27529683

RESUMO

PURPOSE: To qualitatively and quantitatively compare abdominal computed tomography (CT) images reconstructed with a new version of model-based iterative reconstruction (Veo 3.0; GE Healthcare) to those created with Veo 2.0. MATERIALS AND METHODS: This retrospective study was approved by our institutional review board and was Health Insurance Portability and Accountability Act compliant. The raw data from 29 consecutive patients who had undergone CT abdomen scanning was used to reconstruct 4 sets of 3.75-mm axial images: Veo 2.0, Veo 3.0 standard, Veo 3.0 5% resolution preference (RP), and Veo 3.0 20% RP. A slice thickness optimization of 3.75 mm and texture feature was selected for Veo 3.0 reconstructions.The images were reviewed by 3 independent readers in a blinded, randomized fashion using a 5-point Likert scale and 5-point comparative scale.Multiple 2-dimensional circular regions of interest were defined for noise and contrast-to-noise ratio measurements. Line profiles were drawn across the 7 lp/cm bar pattern of the CatPhan 600 phantom for spatial resolution evaluation. RESULTS: The Veo 3.0 standard image set was scored better than Veo 2.0 in terms of artifacts (mean difference, 0.43; 95% confidence interval [95% CI], 0.25-0.6; P < 0.0001), overall image quality (mean difference, 0.87; 95% CI, 0.62-1.13; P < 0.0001) and qualitative resolution (mean difference, 0.9; 95% CI, 0.69-1.1; P < 0.0001). Although the Veo 3.0 standard and RP05 presets were preferred across most categories, the Veo 3.0 RP20 series ranked best for bone detail. Image noise and spatial resolution increased along a spectrum with Veo 2.0 the lowest and RP20 the highest. CONCLUSION: Veo 3.0 enhances imaging evaluation relative to Veo 2.0; readers preferred Veo 3.0 image appearance despite the associated mild increases in image noise. These results provide suggested parameters to be used clinically and as a basis for future evaluations, such as focal lesion detection, in the oncology setting.


Assuntos
Neoplasias Abdominais/diagnóstico por imagem , Algoritmos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Radiografia Abdominal/métodos , Software , Tomografia Computadorizada por Raios X/métodos , Adulto , Feminino , Humanos , Masculino , Intensificação de Imagem Radiográfica/métodos , Distribuição Aleatória , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Razão Sinal-Ruído , Adulto Jovem
20.
World J Radiol ; 8(7): 707-15, 2016 Jul 28.
Artigo em Inglês | MEDLINE | ID: mdl-27551341

RESUMO

AIM: To compare breath-hold cartesian volumetric interpolated breath-hold examination (cVIBE) and free-breathing radial VIBE (rVIBE) and determine whether rVIBE could replace cVIBE in routine liver magnetic resonance imaging (MRI). METHODS: In this prospective study, 15 consecutive patients scheduled for routine MRI of the abdomen underwent pre- and post-contrast breath-hold cVIBE imaging (19 s acquisition time) and free-breathing rVIBE imaging (111 s acquisition time) on a 1.5T Siemens scanner. Three radiologists with 2, 4, and 8 years post-fellowship experience in abdominal imaging evaluated all images. The radiologists were blinded to the sequence types, which were presented in a random order for each patient. For each sequence, the radiologists scored the cVIBE and rVIBE images for liver edge sharpness, hepatic vessel clarity, presence of artifacts, lesion conspicuity, fat saturation, and overall image quality using a five-point scale. RESULTS: Compared to rVIBE, cVIBE yielded significantly (P < 0.001) higher scores for liver edge sharpness (mean score, 3.87 vs 3.37), hepatic-vessel clarity (3.71 vs 3.18), artifacts (3.74 vs 3.06), lesion conspicuity (3.81 vs 3.2), and overall image quality (3.91 vs 3.24). cVIBE and rVIBE did not significantly differ in quality of fat saturation (4.12 vs 4.03, P = 0.17). The inter-observer variability with respect to differences between rVIBE and cVIBE scores was close to zero compared to random error and inter-patient variation. Quality of rVIBE images was rated as acceptable for all parameters. CONCLUSION: rVIBE cannot replace cVIBE in routine liver MRI. At 1.5T, free-breathing rVIBE yields acceptable, although slightly inferior image quality compared to breath-hold cVIBE.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA