RESUMO
Objectives: We recount our experiences of relocating an active mycobacteriology reference level service in Karachi, Pakistan, from an older accredited biosafety level-3 facility to a newly constructed and environmentally validated facility. Methods: The service relocation planning, execution, and verification stages are described in detail. Results: Lessons learned from our experience include establishing a service transfer plan, including relevant service staff, obtaining their buy-in on the plan, arranging backup service facilities or liaisons for the execution phase, and ensuring viable backup arrangements for troubleshooting during the verification phase of services in the new facility. Careful planning and inclusion of all stakeholders are critical to avoid service interruptions. Conclusions: This narrative is expected to support other laboratorians, scientists, and clinicians providing laboratory services to large population sectors who are looking to move their services to a new location while continuing to offer said services in a proficient and reliable manner.
Assuntos
Contenção de Riscos Biológicos , Humanos , PaquistãoRESUMO
The MIC method applicable to Gram negative bacilli including Acinetobacter spp. is broth microdilution (BMD). Cost and/or availability issues limit the use of commercial MIC panels in resource limited settings. OBJECTIVES: To design and implement an in-house breakpoint BMD panel (BBMD) for colistin against Gram negative bacilli. DESIGN: BBMD panel was prepared in 96-well plate. MIC concentrations of 1, 2, & 4 âµg/mL for test, and 0.25, 0.5, 1, 2 & 4 âµg/mL for control strains were selected to accommodate 19 test and 3 quality control strains per plate. Plates were frozen at -80 â°C until testing. Validation was performed using strains from a previously published study and compared with freshly prepared MIC panel of 16-0.03 âµg/mL. RESULTS: Validation showed 100% agreement with the reference method and BBMD was introduced into routine laboratory practice for colistin susceptibility of carbapenem resistant Enterobacterales (CRE), Acinetobacter baumannii complex and Pseudomonas aeruginosa. From 2nd July-16th September 2018, a total of 1294 (mean 16.8 â± â5.5 isolates/day) clinical isolates were tested; 1157/1294 were reported (MIC ≤2 âµg/mL) within 24-h, whereas 133 required resistance confirmation by full-range BMD. Resistance was confirmed for all but 24 isolates. These discrepancies were mostly due to contamination with bacterial genera inherently resistant to colistin. CONCLUSION: This BBMD plate is a high through-put and practical method that could reliably be utilized in a routine microbiology laboratory for colistin susceptibility testing of CRE, A. bauamanii complex and P. aeruginosa.
RESUMO
Despite a high burden of chronic pulmonary aspergillosis (CPA) in Pakistan, Aspergillus-specific IgG testing is currently not available. Establishing cut-offs for Aspergillus-specific IgG for CPA diagnosis is crucial due to geographical variation. In settings such as Pakistan, where non-Aspergillus fumigatus (mainly A. flavus) Aspergillus species account for the majority of CPA cases, there is a need to explore additional benefit of Aspergillus flavus-specific IgG detection along with A. fumigatus-specific IgG detection. This study was conducted at the Aga Khan University, Karachi, Pakistan after ethical approval. Serum for IgG detection were collected after informed consent from healthy controls (n = 21), diseased controls (patients with lung diseases, n = 18), and CPA patients (n = 21). A. fumigatus and A. flavus IgG were detected using Siemens immulite assay. The sensitivity and specificity of A. fumigatus-specific IgG were 80.95% and 82.05%, respectively at a cut-off of 20 mg/L. The sensitivity and specificity of A. flavus-specific IgG were 80.95% and 79.49% at a cut-off of 30 mg/L. We report, for the first time, performance of A. flavus-specific IgG for CPA diagnosis. Although there was no statistically significant difference between the performance of both antigens, it seems contextually relevant to include A. flavus IgG in the CPA diagnostic algorithm in regions with higher non-A. fumigatus CPA infections.
RESUMO
OBJECTIVE: To compare the technical aspects, operative time, safety and effectiveness of percutaneous nephrolithotomy (PCNL) in the free-flank modified supine position (FFMSP) vs. the standard prone position (SPP). PATIENTS AND METHODS: Seventy-seven patients (47 men and 30 women) with renal stones were enrolled and systematically randomised into two groups, A (39 patients) treated using the FFMSP, and B (38 patients) in the SPP. The outcome was considered as a cure (successful procedure) if the patient became stone-free or had residual fragments of <4 mm in diameter. The operative time (from the induction of anaesthesia to the removal of the endotracheal tube) was measured and any operative complications or conflicts were recorded. The different variables were compared and analysed between the groups. RESULTS: Patients in both groups had comparable preoperative clinical data and there were no significant differences in the preoperative clinical characteristics. The procedure was successful in 84.6% and 84% of group A and B, respectively. The operative time was significantly longer in group B (SPP) than A (FFMSP). There was no significant difference between the groups in fluoroscopy time and patients' outcome. CONCLUSIONS: The FFMSP (with a cushion under the ipsilateral shoulder) has similar efficacy and safety as the SPP for PCNL and is associated with a significantly quicker operation.