Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Kyobu Geka ; 76(11): 945-948, 2023 Oct.
Artigo em Japonês | MEDLINE | ID: mdl-38056953

RESUMO

Anomalous origin of the coronary artery is a rare congenital malformation that can cause myocardial ischemia and arrhythmia in patients with or without atherosclerotic lesions. We present a case of aortic stenosis (AS) and coronary artery stenosis complicated by anomalous origin of the right coronary artery (RCA) from the aortic valve sinus and its intramural course. The patient was a 66-year-old woman who was diagnosed with AS 4 years prior, and scheduled for surgery owing to gradual progression of stenosis. Preoperative coronary angiography revealed an abnormal origin of the RCA, and during the surgery, the RCA was found located within the aortic wall close to the aortotomy. Thus, bypass surgery was performed using a great saphenous vein, to prevent ischemia of the RCA territory. The patient had good intraoperative and postoperative course, and a coronary computed tomography scan clearly showed the reconstructed RCA.


Assuntos
Estenose da Valva Aórtica , Estenose Coronária , Anomalias dos Vasos Coronários , Isquemia Miocárdica , Idoso , Feminino , Humanos , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Angiografia Coronária/efeitos adversos , Anomalias dos Vasos Coronários/complicações , Anomalias dos Vasos Coronários/diagnóstico por imagem , Anomalias dos Vasos Coronários/cirurgia , Vasos Coronários/cirurgia , Isquemia Miocárdica/etiologia , Tomografia Computadorizada por Raios X
2.
Ann Thorac Cardiovasc Surg ; 29(1): 29-39, 2023 Feb 20.
Artigo em Inglês | MEDLINE | ID: mdl-36418107

RESUMO

PURPOSE: Computational fluid dynamics has enabled the evaluation of coronary flow reserve. The purpose of this study was to clarify the hemodynamic variation and reserve potential of the left internal thoracic artery (LITA). METHODS: Four patients were selected on the basis of various native coronary stenosis patterns and graft design. The wall shear stress and oscillatory shear index were measured, and one patient was selected. Next, we created three hypothetical lesions with 75%, 90%, and 99% stenosis in front of the graft anastomosis, and compared the changes in LITA blood flow and coronary flow distribution. RESULTS: In the 75% to 90% stenosis model, blood flow was significantly higher in the native coronary flow proximal to the coronary artery bypass anastomosis regardless of time phase. In the 99% stenosis model, blood flow from the LITA was significantly dominant compared to native coronary flow at the proximal site of anastomosis. The range of LITA flow variability was the largest at 99% stenosis, with a difference of 70 ml/min. CONCLUSION: The 99% stenosis model showed the highest LITA flow. The range of LITA flow variability is large, suggesting that it may vary according to the rate of native coronary stenosis.


Assuntos
Estenose Coronária , Artéria Torácica Interna , Humanos , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/cirurgia , Artéria Torácica Interna/diagnóstico por imagem , Artéria Torácica Interna/cirurgia , Constrição Patológica , Angiografia Coronária , Resultado do Tratamento , Hemodinâmica , Estenose Coronária/diagnóstico por imagem , Estenose Coronária/etiologia , Estenose Coronária/cirurgia
3.
Ann Vasc Surg ; 71: 533.e7-533.e10, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-32949744

RESUMO

Endovascular approaches to treating a diseased ascending aorta are challenging. We report the use of an endovascular occlusion device for successful closure of a ruptured penetrating atherosclerotic ulcer of an ascending aorta. A 47-year-old female patient with Takayasu arteritis complained of a worsening hemoptysis. She had a history of Bentall procedure for a sinus of Valsalva aneurysm and redo surgery for a ruptured penetrating atherosclerotic ulcer close to the distal anastomosis. She developed methicillin-resistant Staphylococcus aureus (MRSA) mediastinitis after the second procedure and required negative pressure wound therapy. Computed tomographic angiography revealed recurrence of a ruptured penetrating aortic ulcer and an aortobronchial fistula. Because of the high risk of redo sternotomy after MRSA mediastinitis, we used an endovascular occlusion device to achieve successful percutaneous closure. The patient was discharged without any complications. Postoperative computed tomography scans showed that the endovascular device was positioned without migration and that complete thrombosis of the penetrating atherosclerotic ulcer was achieved. This is the first report on endovascular repair of a ruptured penetrating atherosclerotic ulcer of the ascending aorta in Takayasu arteritis.


Assuntos
Doenças da Aorta/terapia , Fístula Brônquica/terapia , Procedimentos Endovasculares , Arterite de Takayasu/complicações , Úlcera/terapia , Fístula Vascular/terapia , Doenças da Aorta/diagnóstico por imagem , Doenças da Aorta/etiologia , Fístula Brônquica/diagnóstico por imagem , Fístula Brônquica/etiologia , Procedimentos Endovasculares/instrumentação , Feminino , Humanos , Pessoa de Meia-Idade , Arterite de Takayasu/diagnóstico por imagem , Resultado do Tratamento , Úlcera/diagnóstico por imagem , Úlcera/etiologia , Fístula Vascular/diagnóstico por imagem , Fístula Vascular/etiologia
4.
Interact Cardiovasc Thorac Surg ; 31(2): 268-270, 2020 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-32437582

RESUMO

Intramyocardial dissection (ID) is a rare left ventricular (LV) disorder characterized by myocardial fibre dissection and neocavitation. In this study, we present a rare case of a 66-year-old woman who had a history of sarcoidosis with non-ischaemic ID following total arch replacement. ID developed suddenly in the free wall of the LV and expanded rapidly to form an LV aneurysm. We successfully performed LV reconstructive surgery to prevent ID rupture.


Assuntos
Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/cirurgia , Dissecção Aórtica/etiologia , Procedimentos Cirúrgicos Cardíacos/métodos , Aneurisma Cardíaco/etiologia , Complicações Pós-Operatórias , Procedimentos Cirúrgicos Vasculares/efeitos adversos , Idoso , Dissecção Aórtica/diagnóstico , Dissecção Aórtica/cirurgia , Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/diagnóstico , Feminino , Aneurisma Cardíaco/diagnóstico , Aneurisma Cardíaco/cirurgia , Ventrículos do Coração , Humanos , Reimplante
5.
J Thorac Dis ; 12(3): 484-492, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-32274115

RESUMO

BACKGROUND: Fibrin glue effectively controls air leakage in lung surgery; however, allogenic fibrin glue cannot eliminate the risks of infection and allergy despite current sterilization methods. Autologous fibrin glue (AFG) could be a good alternative, but is not commonly used worldwide because of its limited availability and lack of evidence. Herein, we report clinical outcomes of AFG in thoracic surgery. METHODS: We retrospectively analyzed patients who underwent lobectomies or segmentectomies between November 2016 and September 2017 in our institution. We used two types of AFGs. One was a partially-autologous fibrin glue (PAFG), the components of which are largely autologous but which contains allogenic thrombin. The other was a completely-autologous fibrin glue (CAFG) which has no allogenic components. PAFG was used in the first half of the study period, after which CAFG was used from March 2017 onward. Patients who did not undergo AFG generation were categorized as the non-AFG group. The perioperative outcomes of the three groups were evaluated. RESULTS: A total of 207 patients underwent lung surgery, including 118 lobectomies and 89 segmentectomies. Among them, 83 patients received PAFG, 94 received CAFG, and 30 received non-AFG. The mean postoperative drainage period was within a few days in each group (PAFG vs. CAFG vs. non-AFG: 3.23±3.91 vs. 3.16±4.04 vs. 3.17±4.16 days, respectively; P=0.405), and the incidence of postoperative prolonged air leakage was within an acceptable range (PAFG vs. CAFG vs. non-AFG: 13.3% vs. 12.8% vs. 16.7%, respectively; P=0.821). CONCLUSIONS: The use of AFG is clinically feasible for patients who undergo lobectomies or segmentectomies. AFGs could be a viable alternative to conventional allogenic fibrin glues.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA