Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Am J Emerg Med ; 34(12): 2272-2276, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27592725

RESUMO

OBJECTIVES: To investigate the effects of bed width on the quality of chest compressions during simulated in-hospital resuscitation. METHODS: Each candidate performed two 2-minute cycles of compression-only cardiopulmonary resuscitation on an adult manikin placed on either an emergency stretcher (narrow bed) or a standard hospital bed (wide bed) in random order at 1 day intervals. We conducted subjective assessments of cardiopulmonary resuscitation quality and rescuer fatigue at the end of each session, using surveys. RESULTS: There were no significant differences between narrow and wide bed sessions in either mean depth or the percentage of compressions with adequate depth (P=.56 and .58, respectively). The mean rate of compressions and the percentage of compressions with adequate rate were also similar between sessions (P=.24 and .27, respectively). However, the percentage of correct hand position and complete chest recoil was significantly higher in the narrow bed session than in the wide bed session (P=.02 and .02, respectively). In addition, survey results showed that rescuers felt more comfortable and less exhausted in the narrow bed session compared with the wide bed session (P<.001 and < .001). CONCLUSIONS: When rescuers performed chest compressions on an emergency stretcher, chest compression quality increased, and the fatigue of rescuers decreased compared with a standard hospital bed. Therefore, we propose a narrow bed for critically ill inpatients with high risk of cardiac arrest.


Assuntos
Leitos , Reanimação Cardiopulmonar/normas , Fadiga/etiologia , Massagem Cardíaca/normas , Estudos Cross-Over , Desenho de Equipamento , Feminino , Mãos , Humanos , Masculino , Manequins , Postura , Macas , Análise e Desempenho de Tarefas , Adulto Jovem
2.
Transpl Int ; 29(1): 98-107, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26404764

RESUMO

The aim of this study was to determine the role of ALDH2 in the injury of liver from brain-dead donors. Using brain-dead rabbit model and hypoxia model, levels of ALDH2 and apoptosis in tissues and cell lines were determined by Western blot, flow cytometry (FCM), and transferase (TdT)-mediated biotin-16-dUTP nick-end labeling (TUNEL) assays. After the expression of ALDH2 during hypoxia had been inhibited or activated, the accumulations of 4-hydroxynonenal (4-HNE) and molecules involved in mitogen-activated protein kinase (MAPK) signaling pathway were analyzed using ELISA kit and Western blot. The low expression of phosphorylated ALDH2 in liver was time-dependent in the brain-dead rabbit model. Immunohistochemistry showed ALDH2 was primarily located in endothelial, and the rates of cell apoptosis in the donation after brain-death (DBD) rabbit groups significantly increased with time. Following the treatment of inhibitor of ALDH2, daidzein, in combination with hypoxia for 8 h, the apoptosis rate and the levels of 4-HNE, P-JNK, and cleaved caspase-3 significantly increased in contrast to that in hypoxic HUVECs; however, they all decreased after treatment with Alda-1 and hypoxia compared with that in hypoxic HUVECs (P < 0.05). Instead, the levels of P-P38, P-ERK, P-JNK, and cleaved caspase-3 decreased and the ratio of bcl-2/bax increased with ad-ALDH2 (10(6) pfu/ml) in combination with hypoxia for 8 h, which significantly alleviated in contrast to that in hypoxic HUVECs. We found low expression of ALDH2 and high rates of apoptosis in the livers of brain-dead donor rabbits. Furthermore, decreased ALDH2 led to apoptosis in HUVECs through MAPK pathway.


Assuntos
Aldeído Desidrogenase/metabolismo , Morte Encefálica , Fígado/enzimologia , Mitocôndrias/enzimologia , Proteínas Quinases Ativadas por Mitógeno/metabolismo , Animais , Biomarcadores/metabolismo , Western Blotting/métodos , Modelos Animais de Doenças , Ensaio de Imunoadsorção Enzimática/métodos , Rejeição de Enxerto , Sobrevivência de Enxerto , Células Endoteliais da Veia Umbilical Humana/citologia , Células Endoteliais da Veia Umbilical Humana/metabolismo , Humanos , Imuno-Histoquímica , Marcação In Situ das Extremidades Cortadas , Fígado/lesões , Fígado/patologia , Transplante de Fígado/efeitos adversos , Transplante de Fígado/métodos , Masculino , Mitocôndrias/patologia , Coelhos , Distribuição Aleatória , Sensibilidade e Especificidade
3.
PLoS One ; 10(8): e0133483, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26267353

RESUMO

Previous studies have shown improved external chest compression (ECC) quality and delayed rescuer fatigue when the dominant hand (DH) was in contact with the sternum. However, many rescuers prefer placing the non-dominant hand (NH) in contact with the sternum during ECC. We aimed to investigate the effects of up-down hand position switch on the quality of ECC and the fatigue of rescuers during cardiopulmonary resuscitation (CPR). After completion of a review of the standard adult basic life support (BLS) course, every candidate performed 10 cycles of single adult CPR twice on an adult manikin with either a constant hand position (CH) or a switched hand position (SH) in random order at 7-day intervals. The rescuers' general characteristics, hand positions, physiological signs, fatigue appearance and ECC qualities were recorded. Our results showed no significant differences in chest compression quality for the DH position rescuers between the CH and SH sessions (p>0.05, resp.). And also no significant differences were found for Borg score (p = 0.437) or cycle number (p = 0.127) of fatigue appearance after chest compressions between the two sessions. However, for NH position rescuers, the appearance of fatigue was delayed (p = 0.046), with a lower Borg score in the SH session (12.67 ± 2.03) compared to the CH session (13.33 ± 1.95) (p = 0.011). Moreover, the compression depth was significantly greater in the SH session (39.3 ± 7.2 mm) compared to the CH session (36.3 ± 8.1 mm) (p = 0.015). Our data suggest that the up-down hand position switch during CPR may delay the fatigue of non-dominant hand position rescuers and improve the quality of chest compressions.


Assuntos
Reanimação Cardiopulmonar/métodos , Oscilação da Parede Torácica/métodos , Fadiga/prevenção & controle , Mãos/fisiologia , Estudos Cross-Over , Feminino , Lateralidade Funcional , Humanos , Masculino , Manequins , Pressão , Distribuição Aleatória , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA