RESUMO
BACKGROUND: Achalasia is a rare motility disorder of the esophagus often accompanied by immune dysregulation, yet specific underlying mechanisms remain poorly understood. METHODS: We utilized Mendelian randomization (MR) to explore the causal effects of cytokine levels on achalasia, with cis-expression/protein quantitative trait loci (cis-eQTLs/pQTLs) for 47 cytokines selected from a genome-wide association study (GWAS) meta-analysis and GWAS data for achalasia obtained from FinnGen. For cytokines significantly linked to achalasia, we analyzed their plasma concentrations and expression differences in the lower esophageal sphincter (LES) using enzyme-linked immunosorbent assay and single-cell RNA sequencing (scRNA-seq) profiling, respectively. We further employed bioinformatics approaches to investigate underlying mechanisms. RESULTS: We revealed positive associations of circulating Eotaxin, macrophage inflammatory protein-1b (MIP1b), soluble E-selectin (SeSelectin) and TNF-related apoptosis-inducing ligand (TRAIL) with achalasia. When combining MR findings with scRNA-seq data, we observed upregulation of TRAIL (OR = 2.70, 95% CI, 1.20-6.07), encoded by TNFSF10, in monocytes and downregulation of interleukin-1 receptor antagonist (IL-1ra) (OR = 0.70, 95% CI 0.59-0.84), encoded by IL1RN, in FOS_macrophages in achalasia. TNFSF10high monocytes in achalasia displayed activated type I interferon signaling, and IL1RNlow FOS_macrophages exhibited increased intercellular communications with various lymphocytes, together shaping the proinflammatory microenvironment of achalasia. CONCLUSIONS: We identified circulating Eotaxin, MIP1b, SeSelectin and TRAIL as potential drug targets for achalasia. TNFSF10high monocytes and IL1RNlow macrophages may play a role in the pathogenesis of achalasia.
Assuntos
Citocinas , Acalasia Esofágica , Estudo de Associação Genômica Ampla , Análise da Randomização Mendeliana , Células Mieloides , Análise de Sequência de RNA , Acalasia Esofágica/genética , Acalasia Esofágica/sangue , Humanos , Citocinas/sangue , Masculino , Análise de Sequência de RNA/métodos , Células Mieloides/metabolismo , Feminino , Análise de Célula Única/métodos , Esfíncter Esofágico Inferior/fisiopatologia , Pessoa de Meia-Idade , Locos de Características Quantitativas , AdultoRESUMO
PURPOSE: To explore the feasibility of peroral endoscopic myotomy (POEM) in patients with achalasia and hiatal hernia. MATERIALS AND METHODS: We performed a retrospective review of 2136 patients with achalasia between January 2016 and December 2022. Patients with achalasia and hiatal hernia were assigned into study group, and matched patients with achalasia but no hiatal hernia were assigned into control group. The preoperative baseline information, procedure-related adverse events (AEs) and follow-up data were compared between the two groups. RESULTS: Hiatal hernia was identified in 56/1564 (3.6%) patients with achalasia. All of these patients underwent POEM with success. The preoperative baseline characteristics were similar between the study and control group. The study group presented with a similar rate of mucosal injury (12.5% vs 16.1, P = 0.589), pneumothorax (3.6% vs 1.8%, P = 1.000), pleural effusion (8.9% vs 12.5%, P = 0.541) and major AEs (1.8% vs 1.8%, P = 1.000) compared with the control group. As for the follow-up data, no significant differences were observed in clinical success (96.4% vs 92.9%, P = 0.679; 93.6% vs 94.0%, P = 1.000; 86.5% vs 91.4%, P = 0.711) clinical reflux (25.0% vs 19.6%, P = 0.496; 31.9% vs 26.0%, P = 0.521; 35.1% vs 31.4%, P = 0.739) and proton pump inhibitor usage (17.9% vs 16.1%, P = 0.801; 29.8% vs 24.0%, P = 0.520; 32.4% vs 25.7%, P = 0.531) between the study group and control group at 1-year, 2-year and 3-year follow-ups. CONCLUSIONS: POEM is a safe and effective treatment for achalasia combined with hiatal hernia.
Assuntos
Acalasia Esofágica , Hérnia Hiatal , Miotomia , Cirurgia Endoscópica por Orifício Natural , Humanos , Acalasia Esofágica/cirurgia , Acalasia Esofágica/complicações , Hérnia Hiatal/cirurgia , Hérnia Hiatal/complicações , Masculino , Feminino , Estudos Retrospectivos , Pessoa de Meia-Idade , Adulto , Cirurgia Endoscópica por Orifício Natural/métodos , Resultado do Tratamento , Miotomia/métodos , Estudos de Viabilidade , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Idoso , Esofagoscopia/métodosRESUMO
Transition-metal-catalyzed C-Si/Ge cross-coupling offers promising avenues for the synthesis of organosilanes/organogermanes, yet it is fraught with long-standing challenges. A Ni/Ti-catalyzed strategy is reported here, allowing the use of disubstituted malononitriles as tertiary C(sp3) coupling partners to couple with chlorosilanes and chlorogermanes, respectively. This method enables the catalytic cleavage of the C(sp3)-CN bond of the quaternary carbon followed by the formation of C(sp3)-Si/C(sp3)-Ge bonds from ubiquitously available starting materials. The efficiency and generality are showcased by a broad scope for both of the coupling partners, therefore holding the potential to synthesize structurally diverse quaternary organosilanes and organogermanes that were difficult to access previously.
RESUMO
The eye lens is responsible for focusing objects at various distances onto the retina and its refractive power is determined by its surface curvature as well as its internal gradient refractive index (GRIN). The lens continues to grow with age resulting in changes to the shape and to the GRIN profile. The present study aims to investigate how the ageing process may influence lens optical development. Murine lenses of accelerated senescence-prone strain (SAMP8) aged from 4 to 50 weeks; senescence-resistant strain (SAMR1) aged from 5 to 52 weeks as well as AKR strain (served as control) aged from 6 to 70 weeks were measured using the X-ray interferometer at the SPring-8 synchrotron Japan within three consecutive years from 2020 to 2022. Three dimensional distributions of the lens GRIN were reconstructed using the measured data and the lens shapes were determined using image segmentation in MatLab. Variations in the parameters describing the lens shape and the GRIN profile with age were compared amongst three mouse strains. With advancing age, both the lens anterior and posterior surface flattens and the lens sagittal thickness increase in all three mouse strains (Anterior radius of curvature increase at 0.008 mm/week, 0.007 mm/week and 0.002 mm/week while posterior radius of curvature increase at 0.002 mm/week, 0.007 mm/week and 0.003 mm/week respectively in AKR, SAMP8 and SAMR1 lenses). Compared with the AKR strain, the SAMP8 samples demonstrate a higher rate of increase in the posterior curvature radius (0.007 mm/week) and the thickness (0.015 mm/week), whilst the SAMR1 samples show slower increases in the anterior curvature radius (0.002 mm/week) and its thickness (0.013 mm/week). There are similar age-related trends in GRIN shape in the radial direction (in all three types of murine lenses nr2 and nr6 increase with age while nr4 decrease with age consistently) but not in the axial direction amongst three mouse strains (nz1 of AKR lens decrease while of SAMP8 and SAMR1 increase with age; nz2 of all three models increase with age; nz3 of AKR lens increase while of SAMP8 and SAMR1 decrease with age). The ageing process can influence the speed of lens shape change and affect the GRIN profile mainly in the axial direction, contributing to an accelerated decline rate of the optical power in the senescence-prone strain (3.5 D/week compared to 2.3 D/week in the AKR control model) but a retardatory decrease in the senescence-resistant strain (2.1 D/week compared to the 2.3D/week in the AKR control model).
Assuntos
Envelhecimento , Cristalino , Camundongos , Animais , JapãoRESUMO
The process of lens shape change in the eye to alter focussing (accommodation) is still not fully understood. Modelling approaches have been used to complement experimental findings in order to determine how constituents in the accommodative process influence the shape change of the lens. An unexplored factor in modelling is the role of the modelling software on the results of simulated shape change. Finite element models were constructed in both Abaqus and Ansys software using biological parameters from measurements of shape and refractive index of two 35-year-old lenses. The effect of zonular insertion on simulated shape change was tested on both 35-year-old lens models and with both types of software. Comparative analysis of shape change, optical power, and stress distributions showed that lens shape and zonular insertion positions affect the results of simulated shape change and that Abaqus and Ansys show differences in their respective models. The effect of the software package used needs to be taken into account when constructing finite element models and deriving conclusions.
Assuntos
Análise de Elementos Finitos , Cristalino , Modelos Biológicos , Cristalino/fisiologia , Cristalino/anatomia & histologia , Humanos , Simulação por Computador , Acomodação Ocular/fisiologia , Adulto , SoftwareRESUMO
BACKGROUND AND AIMS: Increased reports on endoscopic resection (ER) of esophageal giant subepithelial lesions (g-SELs) have emerged in recent years. The aim of this study was to evaluate the efficacy, technical difficulty, and safety through our single-center experience. METHODS: Seventy-five patients with g-SELs undergoing endoscopic resection were included in the training set. Clinicopathologic features, procedure-related characteristics, postprocedural outcomes, and follow-up data were analyzed. A predictive nomogram model for procedural difficulty was proposed based on the multivariable logistic regression analysis. Internal and external validations were conducted to verify the model performance. RESULTS: The overall en bloc resection rate was 93.3%. Intraoperative and postoperative adverse events occurred in 7 (9.3%) and 13 (17.3%) patients, respectively. No recurrence or metastasis was observed. Thirty-two (42.7%) patients underwent a difficult procedure. Age (adjusted odds ratio [aOR], .915; P = .004), maximal tumor diameter ≥8 cm (aOR, 9.896; P = .009), irregular shape (aOR, 4.081; P = .053), extraluminal growth pattern (aOR, 5.419; P = .011), and submucosal tunneling endoscopic resection (aOR, .109; P = .042) were found to be statistically or clinically significant factors for predicting endoscopic resection difficulty, based on which a nomogram model was developed. Internal and external validations of the nomogram via receiver-operating characteristic curves and calibration curves achieved favorable results. CONCLUSIONS: Endoscopic resection serves as a promising therapeutic option for esophageal g-SELs. A younger patient age, large tumor size, irregular shape, and extraluminal growth may indicate increased endoscopic resection difficulty, whereas a submucosal tunneling endoscopic resection procedure tends to be of lower difficulty. Our nomogram model performs well for predicting endoscopic resection difficulty for esophageal g-SELs.
Assuntos
Ressecção Endoscópica de Mucosa , Neoplasias Esofágicas , Humanos , Neoplasias Esofágicas/cirurgia , Neoplasias Esofágicas/patologia , Endoscopia , Ressecção Endoscópica de Mucosa/métodos , Resultado do Tratamento , Estudos RetrospectivosRESUMO
Rotator cuff tears are still among the serious challenges encountered by sports medicine surgeons. With the development of arthroscopic technology, the treatment options for irreparable massive rotator cuff tears (IMRCTs) have gradually increased, but postoperatively, these options are prone to graft retears, reoperations, infections, revision surgical procedures, and so on. On the basis of studies on the balance of the force couples of the rotator cuff, more scholars believe that when addressing IMRCTs, attention should be paid to the reconstruction of the force couples of the rotator cuff; hence, we developed the superior fulcrum reconstruction technique. This article describes an alternative approach to IMRCT repair with superior fulcrum reconstruction using autologous ipsilateral peroneus longus tendon.
RESUMO
The Direction of Arrival (DOA) estimation of coherent signals in co-prime arrays has become a popular research topic. However, traditional spatial smoothing and subspace algorithms fail to perform well under low signal-to-noise ratio (SNR) and small snapshots. To address this issue, we have introduced an Enhanced Spatial Smoothing (ESS) algorithm that utilizes a space-time correlation matrix for de-noising and decoherence. Finally, an Estimating Signal Parameter via Rotational Invariance Techniques (ESPRIT) algorithm is used for DOA estimation. In comparison to other decoherence methods, when the SNR is -8 dB and the number of snapshots is 150, the mean square error (MSE) of the proposed algorithm approaches the Cramér-Rao bound (CRB), the probability of resolution (PoR) can reach over 88%, and, when the angular resolution is greater than 4°, the estimation accuracy can reach over 90%.
RESUMO
To determine the effect of zonular forces on lens capsule topography, a finite element (FE) analyses of lens capsules with no lens stroma and constant and variable thickness with anterior capsulotomies of 1.5 mm-6.5 mm were evaluated when subjected to equatorial (Ez), anterior (Az) and posterior (Pz) zonular forces. The lens capsule was considered in the unaccommodated state when the total initial zonular force was 0.00075 N or 0.3 N. From the total 0.00075 N zonular force, the Ez force was increased in 0.000125 N steps for a maximum force of 0.03 N and simultaneously the Az plus Pz force was reduced in 0.000125 N steps to zero. In addition, the force of all the zonules was reduced from 0.00075 N and separately from 0.3 N in 0.000125 N steps to zero. Only when Ez force was increased as Az and Pz force was reduced did the capsule topography simulate in vivo observations with the posterior capsule pole bowing posteriorly. The posterior bowing was directly related to Ez force and capsulotomy size. Whether the total force of all the zonules in the unaccommodated state was 0.00075 N or 0.3 N and reduced in steps to zero, the lens capsule topography did not emulate the in vivo observations. The FE analysis demonstrated that Ez tension increases while the Az and Pz tension decreases and that all the zonules do not relax during ciliary muscle contraction.
Assuntos
Cápsula do Cristalino , Cristalino , Análise de Elementos Finitos , Cristalino/fisiologia , Cápsula do Cristalino/fisiologia , Corpo Ciliar , Músculo LisoRESUMO
PURPOSE: To explore the synergistic function of the ligaments in eye, the zonular fibres, that mediate change in eye lens shape to allow for focussing over different distances. METHODS: A set of 3D Finite Element models of the anterior eye together with a custom developed pre-stress modelling approach was proposed to simulate vision for distant objects (the unaccommodated state) to vision for near objects (accommodation). One of the five zonular groups was cut off in sequence creating five models with different zonular arrangements, the contribution of each zonular group was analysed by comparing results of each specific zonular-cut model with those from the all-zonules model in terms of lens shape and zonular tensions. RESULTS: In the all-zonular model, the anterior and equatorial zonules carry the highest tensions. In the anterior zonular-cut model, the equatorial zonular tension increases while the posterior zonular tension decreases, resulting in an increase in the change in Central Optical Power (COP). In the equatorial zonular-cut model, both the anterior and posterior zonular tensions increase, causing a decreasing change in COP. The change in COP decreases only slightly in the other models. For vitreous zonular-cut models, little change was seen in either the zonular tension or the change in COP. CONCLUSIONS: The anterior and the equatorial zonular fibres have the major influence on the change in lens optical power, with the anterior zonules having a negative effect and the equatorial zonules contributing a positive effect. The contribution to variations in optical power by the equatorial zonules is much larger than by the posterior zonules.
Assuntos
Corpo Ciliar , Cristalino , Acomodação Ocular , LigamentosRESUMO
Achalasia is a rare motility disorder of the esophagus caused by the gradual degeneration of myenteric neurons. Immune-mediated ganglionitis has been proposed to underlie the loss of myenteric neurons. Here, we measure the immune cell transcriptional profile of paired lower esophageal sphincter (LES) tissue and blood samples in achalasia and controls using single-cell RNA sequencing (scRNA-seq). In achalasia, we identify a pattern of expanded immune cells and a specific transcriptional phenotype, especially in LES tissue. We show C1QC+ macrophages and tissue-resident memory T cells (TRM), especially ZNF683+ CD8+ TRM and XCL1+ CD4+ TRM, are significantly expanded and localized surrounding the myenteric plexus in the LES tissue of achalasia. C1QC+ macrophages are transcriptionally similar to microglia of the central nervous system and have a neurodegenerative dysfunctional phenotype in achalasia. TRM also expresses transcripts of dysregulated immune responses in achalasia. Moreover, inflammation increases with disease progression since immune cells are more activated in type I compared with type II achalasia. Thus, we profile the immune cell transcriptional landscape and identify C1QC+ macrophages and TRM as disease-associated immune cell subsets in achalasia.
Assuntos
Acalasia Esofágica , Humanos , Acalasia Esofágica/genética , Esfíncter Esofágico Inferior , Neurônios , Inflamação , MacrófagosRESUMO
Retinal diseases are a rising concern as major causes of blindness in an aging society; therapeutic options are limited, and the precise pathogenesis of these diseases remains largely unknown. Intraocular drug delivery and nanomedicines offering targeted, sustained, and controllable delivery are the most challenging and popular topics in ocular drug development and toxicological evaluation. Retinal organoids (ROs) and organoid-on-a-chip (ROoC) are both emerging as promising in-vitro models to faithfully recapitulate human eyes for retinal research in the replacement of experimental animals and primary cells. In this study, we review the generation and application of ROs resembling the human retina in cell subtypes and laminated structures and introduce the emerging engineered ROoC as a technological opportunity to address critical issues. On-chip vascularization, perfusion, and close inter-tissue interactions recreate physiological environments in vitro, whilst integrating with biosensors facilitates real-time analysis and monitoring during organogenesis of the retina representing engineering efforts in ROoC models. We also emphasize that ROs and ROoCs hold the potential for applications in modeling intraocular drug delivery in vitro and developing next-generation retinal drug delivery strategies.
Assuntos
Organoides , Retina , Animais , Humanos , Espécies Reativas de Oxigênio , Dispositivos Lab-On-A-ChipRESUMO
Purpose: The purpose of this study was to utilize in vivo magnetic resonance imaging (MRI) and optical modeling to investigate how changes in water transport, lens curvature, and gradient refractive index (GRIN) alter the power of the mouse lens as a function of age. Methods: Lenses of male C57BL/6 wild-type mice aged between 3 weeks and 12 months (N = 4 mice per age group) were imaged using a 7T MRI scanner. Measurements of lens shape and the distribution of T2 (water-bound protein ratios) and T1 (free water content) values were extracted from MRI images. T2 values were converted into the refractive index (n) using an age-corrected calibration equation to calculate the GRIN at different ages. GRIN maps and shape parameters were inputted into an optical model to determine ageing effects on lens power and spherical aberration. Results: The mouse lens showed two growth phases. From 3 weeks to 3 months, T2 decreased, GRIN increased, and T1 decreased. This was accompanied by increased lens thickness, volume, and surface radii of curvatures. The refractive power of the lens also increased significantly, and a negative spherical aberration was developed and maintained. Between 6 and 12 months of age, all physiological, geometrical, and optical parameters remained constant, although the lens continued to grow. Conclusions: In the first 3 months, the mouse lens power increased as a result of changes in shape and in the GRIN, the latter driven by the decreased water content of the lens nucleus. Further research into the mechanisms regulating this decrease in mouse lens water could improve our understanding of how lens power changes during emmetropization in the developing human lens.
Assuntos
Cristalino , Refração Ocular , Masculino , Humanos , Animais , Camundongos , Recém-Nascido , Tomografia de Coerência Óptica/métodos , Camundongos Endogâmicos C57BL , Cristalino/fisiologia , Imageamento por Ressonância MagnéticaRESUMO
BACKGROUND: Current treatment of cataract widely used in clinics is by removal of the opacified content from the lens capsule which is followed by insertion of an artificial intraocular lens (IOL). The IOL needs to remain stabilized in the capsular bag for the eye to achieve desired optical quality. The present study aims to investigate how different design parameters of the IOL can influence the axial and rotational stabilities of IOLs using Finite Element Analysis. METHODS: Eight designs of IOL with variations in types of optics surface, types of haptics and haptic angulation were constructed using parameters obtained from an online IOL databank (IOLs.eu). Each IOL was subjected to compressional simulations both by two clamps and by a collapsed natural lens capsule with an anterior rhexis. Comparisons were made between the two scenarios on axial displacement, rotation, and distribution of stresses. RESULTS: The clamps compression method set out by ISO does not always produce the same outcome as the in-the-bag analysis. The open-loop IOLs show better axial stability while the closed-loop IOLs show better rotational stability when compressed by two clamps. Simulations of IOL in the capsular bag only demonstrate better rotational stability for closed-loop designs. CONCLUSIONS: The rotational stability of an IOL is largely dependent on its haptic design whilst the axial stability is affected by the appearance of the rhexis to the anterior capsule which has a major influence on designs with a haptic angulation.
Assuntos
Capsulorrexe , Lentes Intraoculares , Capsulorrexe/métodos , Análise de Elementos Finitos , Implante de Lente Intraocular/métodos , Desenho de Prótese , HumanosRESUMO
The young eye has an accommodative ability involving lens shape changes to focus over different distances. This function gradually decreases with age, resulting in presbyopia. Greater insights into the mechanical properties of anterior eye structures can improve understanding of the causes of presbyopia. The present study aims to develop a multi-axis stretching device for evaluating the mechanical properties of the intact eye lens. A stretching device integrating the mechanical stretcher, motor, torque sensor and data transmission mechanism was designed and developed by 3D printing. The mechanical stretcher can convert rotation into radial movement, both at constant speeds, according to the spiral of Archimedes. The loading unit equipped with eight jaws can hold the eye sample tightly. The developed device was validated with a spring of known constant and was further tested with anterior porcine eye segments. The validation experiment using the spring resulted in stiffness values close to the theoretical spring constant. Findings from measurements with porcine eye samples indicated that the measured forces are within the ranges reported in the literature. The developed multi-axis stretching device has good repeatability during experiments with similar settings and can be reliably used for mechanical evaluations of the intact eye lens.
RESUMO
In early corneal examinations, the relationships between the morphological and biomechanical features of the cornea were unclear. Although consistent links have been demonstrated between the two in certain cases, these are not valid in many diseased states. An accurate assessment of the corneal biomechanical properties is essential for understanding the condition of the cornea. Studies on corneal biomechanics in vivo suggest that clinical problems such as refractive surgery and ectatic corneal disease are closely related to changes in biomechanical parameters. Current techniques are available to assess the mechanical characteristics of the cornea in vivo. Accordingly, various attempts have been expended to obtain the relevant mechanical parameters from different perspectives, using the air-puff method, ultrasound, optical techniques, and finite element analyses. However, a measurement technique that can comprehensively reflect the full mechanical characteristics of the cornea (gold standard) has not yet been developed. We review herein the in vivo measurement techniques used to assess corneal biomechanics, and discuss their advantages and limitations to provide a comprehensive introduction to the current state of technical development to support more accurate clinical decisions.
RESUMO
Minimally invasive surgery has emerged as the dominant theme of modern surgery, in which endoscopic surgery plays a key role. The technique of endoscopic surgery has evolved continuously with extensive research, improving the treatment modalities as well as expanding the indications for its use. As an active perforation endoscopic technique, endoscopic full-thickness resection (EFTR) is mainly used in the treatment of submucosal tumors (SMTs) of the gastrointestinal tract. With decades of evolution, EFTR has gradually developed into a mature endoscopic operation. Based on clinical experience and current research, indications, techniques, clinical outcomes and future perspectives for EFTR are discussed in this paper. We performed a bibliometric study on EFTR literature and showed robust data through a brief meta-analysis on the topic.
Assuntos
Ressecção Endoscópica de Mucosa , Neoplasias Gástricas , Humanos , Neoplasias Gástricas/cirurgia , Resultado do Tratamento , Ressecção Endoscópica de Mucosa/métodos , Previsões , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Estudos RetrospectivosRESUMO
Purpose: To investigate how cataract-linked mutations affect the gradient refractive index (GRIN) and lens opacification in mouse lenses and whether there is any effect on the optics of the lens from treatment with an oxysterol compound. Methods: A total of 35 mice including wild-type and knock-in mutants (Cryaa-R49C and Cryab-R120G) were used in these experiments: 26 mice were treated with topical VP1-001, an oxysterol, in one eye and vehicle in the other, and nine mice were untreated controls. Slit lamp biomicroscopy was used to analyze the lens in live animals and to provide apparent cataract grades. Refractive index in the lenses of 64 unfixed whole mouse eyes was calculated from measurements with X-ray phase tomography based on X-ray Talbot interferometry with a synchrotron radiation source. Results: Heterozygous Cryaa-R49C lenses had slightly irregularly shaped contours in the center of the GRIN and distinct disturbances of the gradient index at the anterior and posterior poles. Contours near the lens surface were denser in homozygous Cryab-R120G lenses. Treatment with topical VP1-001, an oxysterol, showed an improvement in refractive index profiles in 61% of lenses and this was supported by a reduction in apparent lens opacity grade by 1.0 in 46% of live mice. Conclusions: These results indicate that α-crystallin mutations alter the refractive index gradient of mouse lenses in distinct ways and suggest that topical treatment with VP1-001 may improve lens transparency and refractive index contours in some lenses with mutations.
Assuntos
Catarata , Cristalinas , Cristalino , Oxisteróis , Animais , Catarata/genética , Cristalinas/genética , Modelos Animais de Doenças , Cristalino/metabolismo , Cristalino/fisiologia , Camundongos , Oxisteróis/farmacologiaRESUMO
Purpose: Our studies in mouse eye lenses demonstrate that ephrin-A5 and EphA2 are needed for normal epithelial cells and lens transparency. We sought to determine whether EphA2 and ephrin-A5 are important for lens morphometrics, nucleus formation, and refractive index. Methods: We performed tissue morphometric measurements, electron microscopy, Western blots, and interferometric measurements using an X-ray synchrotron beam source to measure the gradient of refractive index (GRIN) to compare mouse lenses with genetic disruption of EphA2 or ephrin-A5. Results: Morphometric analysis revealed that although there is no change in the overall lens volume, there is a change in lens shape in both EphA2-/- lenses and ephrin-A5-/- lenses. Surprisingly, EphA2-/- lenses had small and soft lens nuclei different from hard lens nuclei of control lenses. SEM images revealed changes in cell morphology of EphA2-/- fiber cells close to the center of the lens. Inner EphA2-/- lens fibers had more pronounced tongue-and-groove interdigitations and formed globular membrane morphology only in the deepest layers of the lens nucleus. We did not observe nuclear defects in ephrin-A5-/- lenses. There was an overall decrease in magnitude of refractive index across EphA2-/- lenses, which is most pronounced in the nucleus. Conclusions: This work reveals that Eph-ephrin signaling plays a role in fiber cell maturation, nuclear compaction, and lens shape. Loss of EphA2 disrupts the nuclear compaction resulting in a small lens nucleus. Our data suggest that Eph-ephrin signaling may be required for fiber cell membrane reorganization and compaction and for establishing a normal GRIN.
Assuntos
Núcleo do Cristalino/crescimento & desenvolvimento , Receptor EphA2/fisiologia , Refração Ocular/fisiologia , Animais , Membrana Celular/metabolismo , Membrana Celular/ultraestrutura , Efrina-A5/fisiologia , Técnicas de Genotipagem , Interferometria , Núcleo do Cristalino/metabolismo , Núcleo do Cristalino/ultraestrutura , Camundongos , Camundongos Endogâmicos C57BL , Camundongos Knockout , Microscopia Eletrônica de Varredura , Forma das Organelas/fisiologia , Reação em Cadeia da Polimerase em Tempo Real , Transdução de Sinais/fisiologia , Raios XRESUMO
Lonicera japonica is not only an important resource of traditional Chinese medicine, but also has very high horticultural value. Studies have been performed on the physiological responses of L. japonica leaves to chilling, however, the molecular mechanism underlying the low temperature-induced leaves morphological changes remains unclear. In this study, it has been demonstrated that the ratio of pigments content including anthocyanins, chlorophylls, and carotenoids was significantly altered in response to chilling condition, resulting in the color transformation of leaves from green to purple. Transcriptomic analysis showed there were 10,329 differentially expressed genes (DEGs) co-expressed during chilling stress. DEGs were mainly mapped to secondary metabolism, cell wall, and minor carbohydrate. The upregulated genes (UGs) were mainly enriched in protein metabolism, transport, and signaling, while UGs in secondary metabolism were mainly involved in phenylpropaoids-flavonoids pathway (PFP) and carotenoids pathway (CP). Protein-protein interaction analysis illustrated that 21 interacted genes including CAX3, NHX2, ACA8, and ACA9 were enriched in calcium transport/potassium ion transport. BR biosynthesis pathway related genes and BR insensitive (BRI) were collectively induced by chilling stress. Furthermore, the expression of genes involved in anthocyanins and CPs as well as the content of chlorogenic acid (CGA) and luteoloside were increased in leaves of L. japonica under stress. Taken together, these results indicate that the activation of PFP and CP in leaves of L. japonica under chilling stress, largely attributed to the elevation of calcium homeostasis and stimulation of BR signaling, which then regulated the PFP/CP related transcription factors.