Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Clin Ophthalmol ; 17: 3855-3866, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38105914

RESUMO

Purpose: Visual prognosis and treatment burden for macular neovascularization (MNV) can differ between myopic macular degeneration (MMD) and age-related macular degeneration (AMD). We describe and compare MNV associated with MMD and AMD using swept-source (SS)-OCTA. Patients and Methods: Adult patients with documented MNV associated with MMD or AMD were consecutively recruited. Qualitative and quantitative features were assessed from 6x6mm angiograms, including the MNV area and vessel density (VD). Descriptive statistics and linear regression analyses were carried out. Results: Out of 75 enrolled eyes with diagnosed MNV (30 MMD-MNV and 45 AMD-MNV; mean age 55±19 and 75±8 years, respectively), 44 eyes had discernible MNV (11 MMD-MNV and 33 AMD-MNV) on SS-OCTA at the time of the study and were included in the analysis. The MMD-MNV group exhibited a three-fold smaller sized MNV (p=0.001), lower greatest linear dimension (p=0.009) and greatest vascular caliber (p<0.001) compared to AMD-MNVs, and had a higher prevalence of tree-in-bud pattern. Eyes with AMD showed a higher prevalence of type 1 MNVs with medusa pattern. There was no difference in the location of the MNV, shape's regularity, margins, presence of core vessel, capillary fringe, peripheral loops, or perilesional dark halo (p>0.05) between both conditions. After adjustment, decreased MNV area and increased VD were associated with the tree-in-bud pattern, whereas the diagnosis did not significantly influence those parameters. Conclusion: While larger studies are warranted, this study is the first to describe and compare MMD-MNV and AMD-MNV using SS-OCTA, providing relevant clinical insight on MNV secondary to MMD and AMD. These findings also further validate OCTA as a powerful tool to detect and characterize MNV non-invasively.

2.
J Vitreoretin Dis ; 7(3): 232-238, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37188217

RESUMO

Purpose: To evaluate the association between contrast sensitivity (CS) and central subfield thickness (CST) in diabetic macular edema (DME). Methods: This prospectively recruited, cross-sectional study included eyes with DME evaluated from November 2018 to March 2021. CST was measured using spectral-domain optical coherence tomography on the same day as CS testing. Only eyes with center-involving DME (CST >305 µm for women; >320 µm for men) were included. CS was evaluated using the quantitative CS function (qCSF) test. Outcomes included visual acuity (VA) and the following qCSF metrics: area under the log CS function, contrast acuity (CA), and CS thresholds at 1 to 18 cycles per degree (cpd). Pearson correlation and mixed-effects regression analyses were performed. Results: The cohort included 52 eyes of 43 patients. Pearson correlation analysis showed a stronger association between CST and CS thresholds at 6 cpd (r = -0.422, P = 0.002) than CST and VA (r = 0.293, P = 0.035). Mixed-effects univariate and multivariate regression analyses showed significant associations between CST and CA (ß = -0.001, P = .030), CS at 6 cpd (ß = -0.002, P = .008), and CS at 12 cpd (ß = -0.001, P = .049) but no significant associations between CST and VA. Among the visual function metrics, the effect size of CST was largest on CS at 6 cpd (ßStandardized = -0.37, P = .008). Conclusions: In patients with DME, CS may be more strongly associated with CST than VA. Including CS as an adjunct visual function outcome measure in eyes with DME may prove clinically valuable.

3.
Graefes Arch Clin Exp Ophthalmol ; 261(7): 1835-1859, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-36680613

RESUMO

PURPOSE: Data from healthy eyes is needed to interpret optical coherence tomography angiography (OCTA) findings. However, very little normative data is available for wide-field swept-source OCTA (WF SS-OCTA), particularly 12 × 12-mm and disc-centered angiograms. Therefore, we aim to report quantitative metrics in a large sample of control eyes. METHODS: In this cross-sectional observational study, 482 eyes of 375 healthy adults were imaged on the 100 kHz Zeiss PLEX® Elite 9000 using protocols centered on the fovea (3 × 3, 6 × 6, and 12 × 12-mm) and optic disc (6 × 6 and 12 × 12-mm) between December 2018 and January 2022. The ARI Network (Zeiss Portal v5.4) was used to calculate vessel density (VD) and vessel skeletonized density (VSD) in the superficial capillary plexus, deep capillary plexus, and whole retina, as well as foveal avascular zone (FAZ) parameters. Mixed-effect multiple linear regression models were used for statistical analysis. RESULTS: The subjects' median age was 55 (38-63) years, and 201 (53.6%) were female. Greater age and worse best-corrected visual acuity (BCVA) were associated with significantly lower VD and VSD (p < 0.05). VD and VSD differed based on race and cataract status, but not sex, on some scan protocols (p < 0.05). FAZ circularity decreased with age, and FAZ dimensions differed based on race and ethnicity in certain scan protocols. CONCLUSIONS: We report a large database of parafoveal and peripapillary vascular metrics in several angiogram sizes. In referencing these values, researchers must consider characteristics such as age, race, and BCVA, but will have a valuable point of comparison for OCTA measurements in pathologic settings.


Assuntos
Vasos Retinianos , Tomografia de Coerência Óptica , Humanos , Adulto , Feminino , Pessoa de Meia-Idade , Masculino , Angiofluoresceinografia/métodos , Vasos Retinianos/patologia , Tomografia de Coerência Óptica/métodos , Estudos Transversais , Benchmarking , Acuidade Visual
4.
J Pediatr Hematol Oncol Nurs ; 39(3): 137-142, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35467435

RESUMO

It is widely accepted that educational interventions benefit children with chronic diseases (disease awareness and autonomy) or those undergoing medical procedures (decreased anxiety and improved satisfaction). Hematopoietic cell transplantation (HCT) is an intensive procedure to treat life-threatening diseases but is associated with multiple adverse medical experiences. QuestLeukemia (QuestED, Durham, NC) is a mobile app designed to educate pediatric patients preparing for HCT through age-appropriate videos and quizzes. Here we describe the results of the initial pilot study assessing acceptability and feasibility of QuestLeukemia app. Eligible participants were selected from a convenience sample (inpatient HCT unit and outpatient clinic). Participants spent 30-60 min using the app then completed a survey assessing the app for usability, accessibility, and user satisfaction. Participants identified the app as a useful tool for gaining disease-related knowledge and reported greater autonomy over their disease process. On average, patients indicated that the app was easy to use (M = 4.93), enjoyable (M = 4.79), and comprehensive (M = 4.71). Parents followed similar trends of satisfaction with the app. Pediatric HCT providers likewise reported that the app was easy to use (M = 4.22), enjoyable (M = 4.85), and educationally comprehensive (M = 4.77). The QuestLeukemia mobile application prototype provides an easy, enjoyable, and educational tool for pediatric patients undergoing HCT. This application was well received by patients, parents, and providers. These findings will be used to design future iterations of the game in clinical care.


Assuntos
Aplicativos Móveis , Intervenção Psicossocial , Criança , Doença Crônica , Escolaridade , Humanos , Projetos Piloto
5.
Transl Vis Sci Technol ; 9(9): 16, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32879772

RESUMO

Purpose: To describe the creation of en face retinal vessel shadow view (RVSV) optical coherence tomography (OCT) images and assess the feasibility of using these for evaluating vascular disease in preterm infants at risk for retinopathy of prematurity (ROP). Methods: In this exploratory study, we selected images from eyes with a range of ROP vascular disease, prospectively acquired from preterm infants using an investigational, noncontact, handheld, bedside swept-source OCT. We autosegmented OCT volumes using custom infant-specific software, extracted RVSV-OCT images from volumetric data bracketed around the retinal pigment epithelium, and automontaged the resulting RVSV-OCT images. Three masked ophthalmologists graded the RVSV-OCT montages as plus, pre-plus, or neither and ranked them by relative vascular disease severity. Results: We selected images from 17 imaging sessions (7 plus, 4 pre-plus, 6 neither on clinical examination). On review, 15/17 (88%) RVSV-OCT montages were gradable for plus, pre-plus, or neither and all 17 montages were rankable for relative severity. Intergrader agreement for plus, pre-plus, or neither grading was good (κ, 0.67; 95% confidence interval, 0.42-0.86) and for relative severity ranking was excellent (intraclass correlation coefficient, 0.98; 95% confidence interval, 0.96-0.99). Conclusions: Our novel automatic processing method can create RVSV-OCT montages optimized for retinal vessel visualization for ROP screening. Although our data support the feasibility of using RVSV-OCT montages for ranking relative vascular disease severity, there is room for improved OCT image capture and processing methods in preterm infants screened for ROP. Translational Relevance: Creation and grading of RVSV-OCT images could eventually be integrated into an alternative method for ROP screening.


Assuntos
Retinopatia da Prematuridade , Idade Gestacional , Humanos , Lactente , Recém-Nascido , Recém-Nascido Prematuro , Vasos Retinianos/diagnóstico por imagem , Retinopatia da Prematuridade/diagnóstico por imagem , Tomografia de Coerência Óptica
6.
PLoS One ; 14(12): e0225960, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31825990

RESUMO

PURPOSE: Central foveal thickness (CFT) measurements from optical coherence tomography (OCT) scans provide a precise measure of severity of pathologic changes in the fovea, progress of disease and response to treatment. Although these measures are additionally valuable to assess foveal development in infants, their reproducibility is not known. The goal of this retrospective study is to evaluate the variation and reproducibility of CFT measurements using handheld spectral-domain OCT (hh-SDOCT) in supine infants compared to conventional adult tabletop imaging. METHODS: Imaging sessions with multiple macular, volume scans in one eye were selected for analysis from two participant groups: Group 1, 25 imaging sessions from 21 preterm infants without macular edema imaged supine in the nursery using hh-SDOCT (Leica/Bioptigen Envisu C2300, RTP, NC); Group 2, 25 imaging sessions from 25 adults imaged using tabletop Bioptigen SDOCT. For each imaging session, three macular OCT volumes with acceptable image quality were selected for analysis. CFTs were measured using a customized script for automatic segmentation. An expert grader and a typical grader corrected the segmentation lines for the central foveal frame. Coefficient of variations (CV) and intraclass correlation coefficients (ICC) were calculated for graders and systems and compared to the previous literature on OCT reproducibility. RESULTS: CFT measurements were repeatable and reproducible for both handheld and tabletop SDOCT systems. For handheld, grader ICC (CI) and mean CV were 0.94 (0.90-0.97) and 3.8 (typical) and 0.98 (0.96-0.99) and 2.9 (expert), and for tabletop were 0.91(0.83-0.96) and 2.1 (typical) and 0.92 (0.86-0.96) and 1.9 (expert). Intergrader reproducibility of handheld and tabletop SDOCT systems were ICC(CI) 0.97 (0.95-0.98) and 0.93 (0.89-0.96) respectively, and both are comparable to previously reported reproducibility of tabletop systems. CONCLUSION: Handheld SDOCT is a reproducible instrument to measure foveal thicknesses in supine infants. It can be used in clinical research to evaluate foveal changes during retinal development and pathological conditions.


Assuntos
Fóvea Central/diagnóstico por imagem , Fóvea Central/patologia , Decúbito Dorsal , Tomografia de Coerência Óptica/métodos , Idoso , Feminino , Humanos , Lactente , Recém-Nascido , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Tomografia de Coerência Óptica/instrumentação , Tomografia de Coerência Óptica/normas
SELEÇÃO DE REFERÊNCIAS