Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Zhongguo Zhong Yao Za Zhi ; 42(3): 523-530, 2017 Feb.
Artigo em Chinês | MEDLINE | ID: mdl-28952259

RESUMO

A rapid and sensitive UHPLC-HR-MSn method was developed for the identification of chemical constituents in capillary wormwood extract. ACQUITY UHPLC HSS T3 chromatography column (2.1 mm×100 mm, 1.7 µm) was used with 0.1% formic acid-acetonitrile solution as the mobile phase in gradient elution. The extract was detected by ESI-LTQ-Orbitrap equipped with an ESI ion source in a negative mode. Based on the accurate mass measurements, retention time, mass fragmentation patterns and literature reports, a total of 50 compounds including 21 flavonoids, 22 phenolic acids, 6 coumarins and 1 other compound were tentatively screened and characterized. These results are helpful for the comprehensive quality control, better comprehension of the metabolism and further study of pharmacodynamic substance from capillary wormwood extract.


Assuntos
Artemisia/química , Medicamentos de Ervas Chinesas/química , Extratos Vegetais/química , Cromatografia Líquida de Alta Pressão , Cumarínicos/análise , Flavonoides/análise , Hidroxibenzoatos/análise , Controle de Qualidade
2.
Guang Pu Xue Yu Guang Pu Fen Xi ; 25(3): 460-2, 2005 Mar.
Artigo em Chinês | MEDLINE | ID: mdl-16013333

RESUMO

The matrix effect, spectral overlap and background were investigated for X-ray fluorescence (XRF) spectrometric determination of rhenium content according to the analysis requirement of rhenium-tungsten alloys, a key material used in traveling wave tube. The reason for causing the calibration curve nonlinear was explained theoretically when binary ratio technique of XRF was used. Both theoretical and experimental results show that linear calibration curve can be obtained if the curve is plotted by Re% vs. Re Lalpha X-ray intensity instead of binary ratio technique. The method is rapid and accurate and the results obtained in this work are in good agreement with those of chemical analysis. The method has been successfully applied to product quality control.


Assuntos
Ligas/análise , Rênio/análise , Espectrometria por Raios X , Tungstênio/química , Ligas/química , Ligas/normas , Técnicas Eletroquímicas/instrumentação , Controle de Qualidade , Reprodutibilidade dos Testes , Rênio/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA