Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Sci Rep ; 11(1): 2180, 2021 Jan 26.
Artigo em Inglês | MEDLINE | ID: mdl-33500427

RESUMO

When magnetic properties are analysed in a transmission electron microscope using the technique of electron magnetic circular dichroism (EMCD), one of the critical parameters is the sample orientation. Since small orientation changes can have a strong impact on the measurement of the EMCD signal and such measurements need two separate measurements of conjugate EELS spectra, it is experimentally non-trivial to measure the EMCD signal as a function of sample orientation. Here, we have developed a methodology to simultaneously map the quantitative EMCD signals and the local orientation of the crystal. We analyse, both experimentally and by simulations, how the measured magnetic signals evolve with a change in the crystal tilt. Based on this analysis, we establish an accurate relationship between the crystal orientations and the EMCD signals. Our results demonstrate that a small variation in crystal tilt can significantly alter the strength of the EMCD signal. From an optimisation of the crystal orientation, we obtain quantitative EMCD measurements.

2.
Sci Rep ; 11(1): 1942, 2021 Jan 21.
Artigo em Inglês | MEDLINE | ID: mdl-33479336

RESUMO

The strength of the interlayer exchange coupling in [Fe/MgO][Formula: see text](001) superlattices with 2 ≤ N ≤ 10 depends on the number of bilayer repeats (N). The exchange coupling is antiferromagnetic for all the investigated thicknesses while being nine times larger in a sample with N = 4 as compared to N = 2. The sequence of the magnetic switching in two of the samples (N = 4, N = 8) is determined using polarized neutron reflectometry. The outermost layers are shown to respond at the lowest fields, consistent with having the weakest interlayer exchange coupling. The results are consistent with the existence of quantum well states defined by the thickness of the Fe and the MgO layers as well as the number of repeats (N) in [Fe/MgO][Formula: see text](001)superlattices.

3.
Nat Nanotechnol ; 14(4): 328-333, 2019 04.
Artigo em Inglês | MEDLINE | ID: mdl-30804478

RESUMO

Spin waves offer intriguing perspectives for computing and signal processing, because their damping can be lower than the ohmic losses in conventional complementary metal-oxide-semiconductor (CMOS) circuits. Magnetic domain walls show considerable potential as magnonic waveguides for on-chip control of the spatial extent and propagation of spin waves. However, low-loss guidance of spin waves with nanoscale wavelengths and around angled tracks remains to be shown. Here, we demonstrate spin wave control using natural anisotropic features of magnetic order in an interlayer exchange-coupled ferromagnetic bilayer. We employ scanning transmission X-ray microscopy to image the generation of spin waves and their propagation across distances exceeding multiples of the wavelength. Spin waves propagate in extended planar geometries as well as along straight or curved one-dimensional domain walls. We observe wavelengths between 1 µm and 150 nm, with excitation frequencies ranging from 250 MHz to 3 GHz. Our results show routes towards the practical implementation of magnonic waveguides in the form of domain walls in future spin wave logic and computational circuits.

4.
Ultramicroscopy ; 196: 192-196, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-30439606

RESUMO

The weak signal strength in electron magnetic circular dichroism (EMCD) measurements remains one of the main challenges in the quantification of EMCD related EELS spectra. As a consequence, small variations in peak intensity caused by changes of background intervals, choice of method for extraction of signal intensity and equally differences in sample quality can cause strong changes in the EMCD signal. When aiming for high resolution quantitative EMCD, an additional difficulty consists in the fact that the two angular resolved EELS spectra needed to obtain the EMCD signal are taken at two different instances and it cannot be guaranteed that the acquisition conditions for these two spectra are identical. Here, we present an experimental setup where we use a double hole aperture in the transmission electron microscope to obtain the EMCD signal in a single acquisition. This geometry allows for the parallel acquisition of the two electron energy loss spectra (EELS) under exactly the same conditions. We also compare the double aperture acquisition mode with the qE acquisition mode which has been previously used for parallel acquisition of EMCD. We show that the double aperture mode not only offers better signal to noise ratio as compared to qE mode but also allows for much higher acquisition times to significantly improve the signal quality which is crucial for quantitative analysis of the magnetic moments.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA