Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Curr Eye Res ; 40(3): 267-73, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24833321

RESUMO

PURPOSE: To develop a contact lens system that will control the release of an osmoprotectant and a moisturizing agent with the aim to reduce symptoms of ocular dryness. MATERIALS AND METHODS: Profiles of the release of osmoprotectant betaine and moisturizing agent dexpanthenol from senofilcon A and narafilcon B contact lenses were determined in vitro under sink conditions. Both types of lenses were also infused with vitamin E to increase the duration of drug release due to the formation of the vitamin E diffusion barriers in the lenses. The release profiles from vitamin E-infused lenses were compared with those from the control lenses. RESULTS: Both dexpanthenol and betaine are released from commercial silicone hydrogel lenses for only about 10 min. Vitamin E loadings into contact lenses at about 20-23% can increase the release times to about 10 h, which is about 60 times larger compared to the control unmodified lenses. CONCLUSIONS: Vitamin E-loaded silicone hydrogel contact lenses released betaine and dexpanthenol in a controlled fashion.


Assuntos
Betaína/farmacocinética , Lentes de Contato Hidrofílicas , Lipotrópicos/farmacocinética , Ácido Pantotênico/análogos & derivados , Vitamina E/metabolismo , Transporte Biológico Ativo , Sistemas de Liberação de Medicamentos , Síndromes do Olho Seco/tratamento farmacológico , Hidrogéis , Osmorregulação , Ácido Pantotênico/farmacocinética , Silicones , Complexo Vitamínico B/farmacocinética
2.
Biomaterials ; 31(32): 8153-63, 2010 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-20692702

RESUMO

The aged eye's ability to change focus (accommodation) may be restored by replacing the hardened natural lens with a soft gel. Functionalised polysiloxane macromonomers, designed for application as an injectable, in situ curable accommodating intraocular lens (A-IOL), were prepared via a two-step synthesis. Prepolymers were synthesised via ring opening polymerisation (ROP) of octamethylcyclotetrasiloxane (D(4)) and 2,4,6,8-tetramethylcyclotetrasiloxane (D(4)(H)) in toluene using trifluoromethanesulfonic acid (TfOH) as catalyst. Hexaethyldisiloxane (HEDS) was used as the end group to control the molecular weight of the prepolymers, which were then converted to macromonomers by hydrosilylation of the SiH groups with allyl methacrylate (AM) to introduce polymerisable groups. The resulting macromonomers had an injectable consistency and thus, were able to be injected into and refill the empty lens capsular bag. The macromonomers also contained a low ratio of polymerisable groups so that they may be cured on demand, in situ, under irradiation of blue light, in the presence of a photo-initiator, to form a soft polysiloxane gel (an intraocular lens) in the eye. The pre-cure viscosity and post-cure modulus of the polysiloxanes, which are crucial factors for an injectable, in situ curable A-IOL application, were controlled by adjusting the end group and D(4)(H) concentrations, respectively, in the ROP. The macromonomers were fully cured within 5 min under light irradiation, as shown by the rapid change in modulus monitored by photo-rheology. Ex vivo primate lens stretching experiments on an Ex Vivo Accommodation Simulator (EVAS) showed that the polysiloxane gel refilled lenses achieved over 60% of the accommodation amplitude of the natural lens. An in vivo biocompatibility study in rabbits using the lens refilling (Phaco-Ersatz) procedure demonstrated that the soft gels had good biocompatibility with the ocular tissue. The polysiloxane macromonomers meet the targeted optical and mechanical properties of a young natural crystalline lens and show promise as candidate materials for use as injectable, in situ curable A-IOLs for lens refilling procedures.


Assuntos
Acomodação Ocular , Materiais Biocompatíveis/química , Lentes Intraoculares , Siloxanas/química , Animais , Córnea/ultraestrutura , Injeções , Cristalino/fisiologia , Macaca fascicularis , Teste de Materiais , Coelhos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA