Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 58
Filtrar
1.
Proc (Bayl Univ Med Cent) ; 36(5): 592-599, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37614858

RESUMO

Background: Endoscopic sleeve gastroplasty (ESG) has emerged as an effective endoscopic bariatric procedure over the past decade. Data comparing short-term outcomes of ESG based on operator specialty is scarce. We aimed to assess the impact of operator specialization on patient outcomes using a large bariatric-specific database. Methods: We identified a retrospective cohort of patients who underwent ESG by gastroenterologists using the Metabolic and Bariatric Surgery Accreditation Quality Improvement Program database (2020-2021). A matched comparison cohort of patients who underwent ESG by surgeons was identified and underwent 1:1 propensity score matching based on age, race, gender, American Society of Anesthesiologists physical status classification, and preoperative body mass index. Results: After matching, 154 patients were included in the final analysis. Of these, 77 patients underwent ESG by surgeons and 77 by gastroenterologists. In the matched cohort, the median operation time was lower in ESG by surgeons compared to gastroenterologists (P < 0.001). The median percent body mass index decrease was higher in the gastroenterologist cohort compared to the surgeon cohort (4.9% vs 3.8%, P = 0.04). The median percent weight loss after ESG was 4.8% in the surgeon cohort and 5.9% in the gastroenterologist cohort (P = 0.09). There was no statistically significant difference in postoperative emergency department visits (P = 0.65), reoperations (P = 0.15), or reinterventions within 30 days (P = 0.87) between the cohorts. There was no difference in major adverse effects between the groups (0% each). Conclusions: Operator choice does not affect ESG-related adverse events or 30-day outcomes in patients undergoing ESG.

3.
VideoGIE ; 7(1): 1-20, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-35059533

RESUMO

BACKGROUND AND AIMS: Esophageal function testing is an integral component of the evaluation of refractory GERD and esophageal motility disorders. This review summarizes the current technologies available for esophageal function testing, including the functional luminal imaging probe (FLIP), high-resolution esophageal manometry (HRM), and multichannel intraluminal impedance (MII) and pH monitoring. METHODS: We performed a MEDLINE, PubMed, and MAUDE database literature search to identify pertinent clinical studies through March 2021 using the following key words: esophageal manometry, HRM, esophageal impedance, FLIP, MII, and esophageal pH testing. Technical data were gathered from traditional and web-based publications, proprietary publications, and informal communications with pertinent vendors. The report was drafted, reviewed, and edited by the American Society for Gastrointestinal Endoscopy Technology Committee and approved by the Governing Board of the American Society for Gastrointestinal Endoscopy. RESULTS: FLIP is a high-resolution impedance planimetry system used for pressure and dimension measurement in the esophagus, pylorus, and anal sphincter. FLIP provides complementary information to HRM for esophageal motility disorders, especially achalasia. The Chicago classification, based on HRM data, is a widely adopted algorithmic scheme used to diagnose esophageal motility disorders. MII detects intraluminal bolus movement and, combined with pH measurement or manometry, provides information on acid and non-acid gastroesophageal reflux and bolus transit in patients with refractory GERD and for preoperative evaluation for anti-reflux procedures. CONCLUSIONS: Esophageal function testing techniques (FLIP, HRM, and MII-pH) have diagnostic and prognostic value in the evaluation of esophageal motility disorders and refractory GERD. Newer technologies and classification systems have enabled an increased understanding of these diseases.

5.
Endoscopy ; 54(7): 680-687, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-34569611

RESUMO

BACKGROUND: Most studies on endoscopic ultrasound (EUS)-guided gastroenterostomy (EUS-GE) for palliation of malignant gastric outlet obstruction (GOO) utilized a 15-mm lumen-apposing metal stent (LAMS). More recently, a 20-mm LAMS has become available. This study aimed to compare rates of technical and clinical success and adverse events (AEs) in patients undergoing EUS-GE using a 20-mm vs. 15-mm LAMS. METHODS: Patients who underwent EUS-GE with 15-mm or 20-mm LAMS for malignant GOO during the period from January 2018 to October 2020 were included. The primary outcome was clinical success, defined as an increase in the gastric outlet obstruction score (GOOS) by at least 1 point during follow-up. Secondary outcomes were technical success, maximum tolerated diet, re-intervention rate, and rate/severity of AEs. RESULTS: 267 patients (mean age 67 years, 43 % women) with malignant GOO from 19 centers underwent EUS-GE. Clinical success rates were similar for the 15-mm and 20-mm stents (89.2 % [95 %CI 84.2 %-94.2 %] vs. 84.1 % [77.4%-90.6 %], respectively). However, a significantly higher proportion of patients in the 20-mm group tolerated a soft solid/complete diet at the end of follow-up (91.2 % [84.4 %-95.7 %] vs. 81.2 % [73.9 %-87.2 %], P = 0.04). Overall, AEs occurred in 33 patients (12.4 % [8.4 %-16.3 %]), with similar rates for 15-mm and 20-mm stents (12.8 % [7.5 %-18.2 %] vs. 11.8 % [6 %-17.6 %]), including incidence of severe/fatal AEs (2 % [0.4 %-5.8 %] vs. 3.4 % [0.9 %-8.4 %]). CONCLUSIONS: The 20-mm and 15-mm LAMS show similar safety and efficacy for patients undergoing EUS-GE for malignant GOO. The 20-mm LAMS allows a more advanced diet and is, thus preferred for EUS-GE.


Assuntos
Obstrução da Saída Gástrica , Gastroenterostomia , Idoso , Endossonografia/efeitos adversos , Feminino , Obstrução da Saída Gástrica/etiologia , Obstrução da Saída Gástrica/cirurgia , Gastroenterostomia/efeitos adversos , Humanos , Masculino , Stents/efeitos adversos , Ultrassonografia de Intervenção/efeitos adversos
6.
Gastrointest Endosc ; 95(3): 471-479, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-34562471

RESUMO

BACKGROUND AND AIMS: Direct endoscopic necrosectomy (DEN) of walled-off pancreatic necrosis (WOPN) lacks dedicated instruments and requires repetitive and cumbersome procedures. This study evaluated the safety and efficacy of a new powered endoscopic debridement (PED) system designed to simultaneously resect and remove solid debris within WOPN. METHODS: This was a single-arm, prospective, multicenter, international device trial conducted from November 2018 to August 2019 at 10 sites. Patients with WOPN ≥6 cm and ≤22 cm and with >30% solid debris were enrolled. The primary endpoint was safety through 21 days after the last DEN procedure. Efficacy outcomes included clearance of necrosis, procedural time, adequacy of debridement, number of procedures until resolution, hospital stay duration, and quality of life. RESULTS: Thirty patients (mean age, 55 years; 60% men) underwent DEN with no device-related adverse events. Of 30 patients, 15 (50%) achieved complete debridement in 1 session and 20 (67%) achieved complete debridement within 2 or fewer sessions. A median of 1.5 interventions (range, 1-7) were required. Median hospital stay was 10 days (interquartile range, 22). There was an overall reduction of 91% in percent necrosis within WOPN from baseline to follow-up and 85% in collection volume. Baseline WOPN volume was positively correlated with the total number of interventions (ρ = .363, P = .049). CONCLUSIONS: The new PED system seems to be a safe and effective treatment tool for WOPN, resulting in fewer interventions and lower hospital duration when compared with published data on using conventional instruments. Randomized controlled trials comparing the PED system with conventional DEN are needed. (Clinical trial registration number: NCT03694210.).


Assuntos
Pancreatite Necrosante Aguda , Drenagem/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Necrose/cirurgia , Pâncreas/cirurgia , Pancreatite Necrosante Aguda/cirurgia , Estudos Prospectivos , Qualidade de Vida , Estudos Retrospectivos , Stents , Resultado do Tratamento
7.
Gastroenterol Hepatol (N Y) ; 17(2): 79-81, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34035768
8.
Endoscopy ; 53(12): 1246-1249, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-33860483

RESUMO

BACKGROUND : This study evaluated an oroenteric catheter (OEC)-assisted technique to distend the enteric loop for endoscopic ultrasound-guided gastroenterostomy (EUS-GE) in patients with gastric outlet obstruction (GOO). METHODS : Patient outcomes were reviewed. Proximal enteric loops were filled with water via an OEC (7 Fr or 8 Fr), providing a target for EUS-GE using a lumen-apposing metal stent (15-mm caliber). Clinical success was defined as toleration of a non-liquid diet by Day 3. RESULTS : 42 patients (mean age 73.1 [SEM 2.8] years; 23 male) underwent EUS-GE for malignant (n = 37) and benign (n = 5) duodenal strictures. EUS-GE creation was successful in 41/42 (98 %), with mean procedure time of 36 (SEM 3) minutes and no serious complications. Clinical success was achieved in 39/42 (93 %) at 5.7 (SEM 2.6) months' follow-up. Of 14 patients who died, 13 (93 %) maintained oral intake until death. EUS-GE provided good symptom relief in all 28 surviving patients until follow-up. CONCLUSIONS : OEC-assisted EUS-GE provided satisfactory relief of GOO symptoms, with high technical success (98 %) and no serious complications.


Assuntos
Gastroenterostomia , Ultrassonografia de Intervenção , Idoso , Catéteres , Endossonografia , Humanos , Masculino , Estudos Retrospectivos , Stents
10.
Gastrointest Endosc ; 93(2): 323-333, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-33129492

RESUMO

BACKGROUND AND AIMS: EUS remains a primary diagnostic tool for the evaluation of pancreaticobiliary disease. Although EUS combined with FNA or biopsy sampling is highly sensitive for the diagnosis of neoplasia within the pancreaticobiliary tract, limitations exist in specific clinical settings such as chronic pancreatitis. Enhanced EUS imaging technologies aim to aid in the detection and diagnosis of lesions that are commonly evaluated with EUS. METHODS: We reviewed technologies and methods for enhanced imaging during EUS and applications of these methods. Available data regarding efficacy, safety, and financial considerations are summarized. RESULTS: Enhanced EUS imaging methods include elastography and contrast-enhanced EUS (CE-EUS). Both technologies have been best studied in the setting of pancreatic mass lesions. Robust data indicate that neither technology has adequate specificity to serve as a stand-alone test for pancreatic malignancy. However, there may be a role for improving the targeting of sampling and in the evaluation of peritumoral lymph nodes, inflammatory pancreatic masses, and masses with nondiagnostic FNA or fine-needle biopsy sampling. Further, novel applications of these technologies have been reported in the evaluation of liver fibrosis, pancreatic cysts, and angiogenesis within neoplastic lesions. CONCLUSIONS: Elastography and CE-EUS may improve the real-time evaluation of intra- and extraluminal lesions as an adjunct to standard B-mode and Doppler imaging. They are not a replacement for EUS-guided tissue sampling but provide adjunctive diagnostic information in specific clinical situations. The optimal clinical use of these technologies continues to be a focus of ongoing research.


Assuntos
Cisto Pancreático , Neoplasias Pancreáticas , Pancreatite Crônica , Biópsia por Agulha Fina , Endossonografia , Humanos , Neoplasias Pancreáticas/diagnóstico por imagem , Pancreatite Crônica/diagnóstico por imagem
11.
Gastrointest Endosc ; 93(3): 740-749, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-32739483

RESUMO

BACKGROUND AND AIMS: Loop formation can impede endoscope advancement, destabilize the tip, and cause pain. Strategies to mitigate looping include torque-based reduction maneuvers, variable stiffness shafts, and abdominal splinting. In some cases, these strategies are insufficient, and there is need for novel instruments. Loop formation is of particular concern in colonoscopy, but it can also impact performance of other endoscopic procedures such as enteroscopy and altered-anatomy ERCP. In this case series we demonstrate the utility of a novel rigidizing overtube (Pathfinder; Neptune Medical, Burlingame, Calif, USA) in colonoscopy and other endoscopic procedures where loop management is critical. METHODS: We describe our initial experience with the Pathfinder overtube in 29 patients. The overtube is 85 cm long and can accommodate a pediatric colonoscope. In its native state, the overtube is extremely flexible. Once the overtube is advanced to the desired location, application of a vacuum to the device causes the device to become 15 times stiffer. The endoscope can then be advanced through the overtube without loop formation in the region that the overtube traverses. RESULTS: The overtube was used in 29 patients to assist with difficult procedures. Patients were predominantly men (n = 18; 62.1%), with a median age of 66 years (interquartile range, 57-72). One patient received an upper endoscopy (3.4%), 24 received colonoscopy (82.8%), and 4 received enteroscopy (13.8%). The overtube was used in 12 procedures for incomplete colonoscopy (41.4%), 6 for depth (20.7%), and 11 for stability (37.9%). Colonoscopy was performed in the setting of screening (n = 3), surveillance given polyp history (n = 7), referrals for polyp removal (n = 10), workup of iron deficiency anemia (n = 2), and incomplete colonoscopy (n = 1). The lower endoscopy cases had a median cecal intubation time of 5 minutes (interquartile range, 4.25-7). Enteroscopy was performed in 4 patients: In one patient the distal 60 cm of the ileum was examined with a pediatric colonoscope to exclude ileitis, in another the overtube was used to stabilize a 6-mm endoscope to traverse a tight Crohn's ileocolonic stricture, in a third patient altered-anatomy ERCP was performed using an enteroscope through the overtube to reach a hepaticojejunostomy, and in the final patient upper enteroscopy was performed and the mid-jejunum was reached. We present 4 cases that demonstrate the use of the overtube. There were no adverse events. CONCLUSIONS: Initial experience with a novel rigidizing overtube suggests that this tool can be useful in colonoscopy and other endoscopic procedures affected by looping.


Assuntos
Ceco , Colonoscopia , Idoso , Criança , Colonoscópios , Endoscopia Gastrointestinal , Desenho de Equipamento , Humanos , Masculino , Programas de Rastreamento
12.
VideoGIE ; 5(12): 598-613, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33319126

RESUMO

BACKGROUND AND AIMS: Artificial intelligence (AI)-based applications have transformed several industries and are widely used in various consumer products and services. In medicine, AI is primarily being used for image classification and natural language processing and has great potential to affect image-based specialties such as radiology, pathology, and gastroenterology (GE). This document reviews the reported applications of AI in GE, focusing on endoscopic image analysis. METHODS: The MEDLINE database was searched through May 2020 for relevant articles by using key words such as machine learning, deep learning, artificial intelligence, computer-aided diagnosis, convolutional neural networks, GI endoscopy, and endoscopic image analysis. References and citations of the retrieved articles were also evaluated to identify pertinent studies. The manuscript was drafted by 2 authors and reviewed in person by members of the American Society for Gastrointestinal Endoscopy Technology Committee and subsequently by the American Society for Gastrointestinal Endoscopy Governing Board. RESULTS: Deep learning techniques such as convolutional neural networks have been used in several areas of GI endoscopy, including colorectal polyp detection and classification, analysis of endoscopic images for diagnosis of Helicobacter pylori infection, detection and depth assessment of early gastric cancer, dysplasia in Barrett's esophagus, and detection of various abnormalities in wireless capsule endoscopy images. CONCLUSIONS: The implementation of AI technologies across multiple GI endoscopic applications has the potential to transform clinical practice favorably and improve the efficiency and accuracy of current diagnostic methods.

13.
14.
Gastrointest Endosc ; 92(3): 492-507, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32800313

RESUMO

BACKGROUND AND AIMS: As the prevalence of obesity continues to rise, increasing numbers of patients undergo bariatric surgery. Management of adverse events of bariatric surgery may be challenging and often requires a multidisciplinary approach. Endoscopic intervention is often the first line of therapy for management of these adverse events. This document reviews technologies and techniques used for endoscopic management of adverse events of bariatric surgery, organized by surgery type. METHODS: The MEDLINE database was searched through May 2018 for articles related to endoscopic management of adverse events of bariatric interventions by using relevant keywords such as adverse events related to "gastric bypass," "sleeve gastrectomy," "laparoscopic adjustable banding," and "vertical banded sleeve gastroplasty," in addition to "endoscopic treatment" and "endoscopic management," among others. Available data regarding efficacy, safety, and financial considerations are summarized. RESULTS: Common adverse events of bariatric surgery include anastomotic ulcers, luminal stenoses, fistulae/leaks, and inadequate initial weight loss or weight regain. Devices used for endoscopic management of bariatric surgical adverse events include balloon dilators (hydrostatic, pneumatic), mechanical closure devices (clips, endoscopic suturing system, endoscopic plication platform), luminal stents (covered esophageal stents, lumen-apposing metal stents, plastic stents), and thermal therapy (argon plasma coagulation, needle-knives), among others. Available data, composed mainly of case series and retrospective cohort studies, support the primary role of endoscopic management. Multiple procedures and techniques are often required to achieve clinical success, and existing management algorithms are evolving. CONCLUSIONS: Endoscopy is a less invasive alternative for management of adverse events of bariatric surgery and for revisional procedures. Endoscopic procedures are frequently performed in the context of multidisciplinary management with bariatric surgeons and interventional radiologists. Treatment algorithms and standards of practice for endoscopic management will continue to be refined as new dedicated technology and data emerge.


Assuntos
Cirurgia Bariátrica/efeitos adversos , Endoscopia Gastrointestinal , Derivação Gástrica , Gastroplastia/efeitos adversos , Humanos , Obesidade Mórbida/cirurgia , Guias de Prática Clínica como Assunto , Estudos Retrospectivos , Resultado do Tratamento
15.
Gastrointest Endosc ; 92(3): 483-491, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32684298

RESUMO

BACKGROUND AND AIMS: Gastroparesis is a symptomatic chronic disorder of the stomach characterized by delayed gastric emptying in the absence of mechanical obstruction. Several endoscopic treatment modalities have been described that aim to improve gastric emptying and/or symptoms associated with gastroparesis refractory to dietary and pharmacologic management. METHODS: In this report we review devices and techniques for endoscopic treatment of gastroparesis, the evidence regarding their efficacy and safety, and the financial considerations for their use. RESULTS: Endoscopic modalities for treatment of gastroparesis can be broadly categorized into pyloric, nonpyloric, and nutritional therapies. Pyloric therapies such as botulinum toxin injection, stent placement, pyloroplasty, and pyloromyotomy specifically focus on pylorospasm as a therapeutic target. These interventions aim to reduce the pressure gradient across the pyloric sphincter, with a resultant improvement in gastric emptying. Nonpyloric therapies, such as venting gastrostomy and gastric electrical stimulation, are intended to improve symptoms. Nutritional therapies, such as feeding tube placement, aim to provide nutritional support. CONCLUSIONS: Several endoscopic interventions have shown utility in improving the quality of life and symptoms of select patients with refractory gastroparesis. Methods to identify which patients are best suited for a specific treatment are not well established. Endoscopic pyloromyotomy is a relatively recent development that may prove to be the preferred pyloric-directed intervention, although additional and longer-term outcomes are needed.


Assuntos
Gastroparesia , Esvaziamento Gástrico , Gastroparesia/cirurgia , Humanos , Piloromiotomia , Piloro/cirurgia , Qualidade de Vida , Resultado do Tratamento
16.
Gastrointest Endosc ; 92(3): 474-482, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32641215

RESUMO

BACKGROUND AND AIMS: Residual neoplasia after macroscopically complete EMR of large colon polyps has been reported in 10% to 32% of resections. Often, residual polyps at the site of prior polypectomy are fibrotic and nonlifting, making additional resection challenging. METHODS: This document reviews devices and methods for the endoscopic treatment of fibrotic and/or residual polyps. In addition, techniques reported to reduce the incidence of residual neoplasia after endoscopic resection are discussed. RESULTS: Descriptions of technologies and available outcomes data are summarized for argon plasma coagulation ablation, snare-tip coagulation, avulsion techniques, grasp-and-snare technique, EndoRotor endoscopic resection system, endoscopic full-thickness resection device, and salvage endoscopic submucosal dissection. CONCLUSIONS: Several technologies and techniques discussed in this document may aid in the prevention and/or resection of fibrotic and nonlifting polyps.


Assuntos
Pólipos do Colo , Pólipos do Colo/patologia , Pólipos do Colo/cirurgia , Colonoscopia , Neoplasias Colorretais/patologia , Neoplasias Colorretais/cirurgia , Ressecção Endoscópica de Mucosa , Humanos , Mucosa Intestinal/patologia , Neoplasia Residual/patologia , Guias de Prática Clínica como Assunto
17.
Gastrointest Endosc ; 92(6): 1164-1175.e6, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-32692991

RESUMO

BACKGROUND AND AIMS: Endoscopic transoral outlet reduction (TORe) has been used to manage weight regain after Roux-en-Y gastric bypass. We conducted a meta-analysis to summarize the efficacy and safety of the two most commonly used techniques: full-thickness suturing plus argon plasma mucosal coagulation (ft-TORe) and argon plasma mucosal coagulation alone (APMC-TORe). METHODS: A literature search of publication databases was performed from their inception to February 2020 for relevant studies. The outcomes of interest were percentage total body weight loss, gastrojejunal anastomosis (GJA) diameter, and adverse events (AEs). The pooled effect estimates were analyzed using a random-effects model. Meta-regression was conducted to identify associations between GJA diameter and weight loss. RESULTS: Nine ft-TORe (n = 737) and 7 APMC-TORe (n = 888) studies were included. APMC-TORe was performed as a series of sessions (mean number of sessions ranging from 1.2 to 3), whereas ft-TORe was mostly performed as a single session. Percentage total body weight loss was 8.0% (95% confidence interval [CI], 6.3%-9.7%), 9.5% (95% CI, 8.1%-11.0%), and 5.8% (95% CI, 4.3%-7.1%) after ft-TORe and 9.0% (95% CI, 4.1%-13.9%), 10.2% (95% CI, 8.4%-12.1%), and 9.5% (95% CI, 5.7%-13.2%) after APMC-TORe at 3, 6, and 12 months, respectively, with no weight-loss difference at 3 and 6 months (P > .05). Only one severe AE was observed after APMC-TORe and none after ft-TORe. Stricture formation was the most common AE (ft-TORe 3.3% and APMC-TORe 4.8%, P = .38). All were successfully treated by endoscopic dilation or conservative treatment. Smaller aperture of the post-TORe GJA and greater change in the GJA diameter correlated with greater weight loss in APMC-TORe and numerical trends in ft-TORe. CONCLUSIONS: This meta-analysis demonstrates that both ft-TORe and APMC-TORe offer significant and comparable weight-loss outcomes with a high and comparable safety profile. However, APMC-TORe typically required multiple endoscopic sessions. Identifying a goal for the final and change in GJA diameter could be useful treatment targets.


Assuntos
Coagulação com Plasma de Argônio , Derivação Gástrica , Jejuno/cirurgia , Obesidade Mórbida , Estômago/cirurgia , Derivação Gástrica/efeitos adversos , Derivação Gástrica/métodos , Gastroscopia , Humanos , Cirurgia Endoscópica por Orifício Natural , Obesidade Mórbida/cirurgia , Gases em Plasma/uso terapêutico , Recidiva , Reoperação , Técnicas de Sutura , Resultado do Tratamento , Aumento de Peso
18.
Endoscopy ; 52(10): 886-890, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32521549

RESUMO

BACKGROUND: Colonic anastomotic leaks are associated with significant morbidity and mortality. Whereas small case series suggest that fully covered self-expandable metal stents (FCSEMS) are effective, no larger studies have examined the impact of combination endoscopic therapy on colonic anastomotic leaks. METHODS: Our retrospective cohort study reviewed 51 patients undergoing endoscopic therapy for colonic anastomotic leaks between 2011 and 2018. Patients receiving combination therapy involving FCSEMS plus local closure (n = 24) were compared with patients receiving FCSEMS alone (n = 18) or endoscopic suturing alone (n = 9). The primary outcomes were technical and clinical success (resolution of leak, removal of percutaneous drains, avoidance of surgical reoperation, and reversal of temporary diversion). RESULTS: Clinical success was achieved in 55 % of patients. Clinical success was achieved in 18/24 patients (75 %) with combination therapy compared with 6/18 patients receiving FCSEMS alone (33 %, adjusted risk ratio [RR] 2.16, 95 % confidence interval [CI] 1.10 - 4.24; P = 0.02) and 4 /9 patients undergoing endoscopic suturing alone (44 %, RR 1.91, 95 %CI 0.84 - 4.31; P = 0.10). Stent migration occurred in 40 % of patients. CONCLUSIONS: This large series demonstrates that combination therapy was associated with a higher rate of clinical success, and future prospective studies are warranted.


Assuntos
Fístula Anastomótica , Stents Metálicos Autoexpansíveis , Fístula Anastomótica/etiologia , Fístula Anastomótica/cirurgia , Humanos , Estudos Prospectivos , Estudos Retrospectivos , Stents Metálicos Autoexpansíveis/efeitos adversos , Stents , Resultado do Tratamento
19.
Gastrointest Endosc Clin N Am ; 30(1): 115-128, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31739958

RESUMO

Obesity is a public health pandemic and leading contributor to morbidity and mortality. Endoscopic bariatric therapies have emerged as a viable minimally invasive treatment option to fill the therapeutic gap between conservative and surgical approaches. The ability to reliably place full-thickness sutures throughout the gastrointestinal tract has opened the door to novel endoscopic gastric restrictive procedures. A growing body of literature supports endoscopic sleeve gastroplasty as a safe, effective, and reproducible endoscopic treatment of obesity and metabolic syndrome. In addition, endoscopic sutured revision procedures following gastric bypass and sleeve gastrectomy are now first-line with demonstrable safety and long-term efficacy.


Assuntos
Cirurgia Bariátrica/instrumentação , Endoscopia/instrumentação , Obesidade/cirurgia , Técnicas de Sutura/instrumentação , Cirurgia Bariátrica/métodos , Endoscopia/métodos , Humanos , Resultado do Tratamento
20.
VideoGIE ; 4(8): 343-350, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-31388606

RESUMO

With the development of reliable endoscopic closure techniques and tools, endoscopic full-thickness resection (EFTR) is emerging as a therapeutic option for the treatment of subepithelial tumors and epithelial neoplasia with significant fibrosis. EFTR may be categorized as "exposed" and "nonexposed." In exposed EFTR, the full-thickness resection is undertaken with a tunneled or nontunneled technique, with subsequent closure of the defect. In nonexposed EFTR, a secure serosa-to-serosa apposition is achieved before full-thickness resection of the isolated lesion. This document reviews current techniques and devices used for EFTR and reviews clinical applications and outcomes.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA