Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
J Prev Alzheimers Dis ; 9(3): 491-498, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35841250

RESUMO

BACKGROUND: Alzheimer's disease (AD) and frontotemporal lobar degeneration (FTLD) are heterogeneous in their clinical presentation and underlying pathology, but they often have overlapping features. Diagnostic accuracy is critical for guiding patient management. Cerebrospinal fluid (CSF) diagnostic assays for the differentiation of AD and FTLD may increase diagnostic accuracy. OBJECTIVES: In this study, we aimed to understand the potential role of CSF biomarkers and biomarker ratios, measured using Elecsys® CSF immunoassays (Roche Diagnostics International Ltd, Rotkreuz, Switzerland), in the differential diagnosis of AD and FTLD. DESIGN: This study was conducted at a single center in Munich, Germany between July 2019 and July 2020. Patient CSF samples were retrospectively collected from the study center biobank. PARTICIPANTS: A total of 130 patients with cognitive impairment were included in the study; 86 patients were diagnosed with AD and 44 with FTLD (behavioral variant frontotemporal dementia, semantic variant of primary progressive aphasia, and non-fluent variant of primary progressive aphasia), based on core clinical criteria and a non-CSF biomarker, a typical pattern of regional hypometabolism on [18F] fluorodeoxyglucose positron emission tomography. MEASUREMENTS: Patient CSF biomarker concentrations were measured using Elecsys CSF immunoassays. Receiver operating characteristic analyses were conducted to determine areas under the curve (AUCs) for CSF biomarker performance. Sensitivity and specificity analyses were conducted to evaluate the performance of established cut-offs (Aß42 ≤1000 pg/mL, pTau181/Aß42 ratio >0.024, and tTau/Aß42 ratio >0.28) and optimized cut-offs based on Youden's index. RESULTS: AUC-based performance was similarly good for the pTau181/Aß42 ratio (AUC=0.841; 95% CI: 0.759-0.923), pTau181/Aß40 ratio (AUC=0.837; 95% CI: 0.754-0.919), Aß42/Aß40 ratio (AUC=0.829; 95% CI: 0.746-0.912), tTau/Aß42 ratio (AUC=0.822; 95% CI: 0.736-0.908), pTau181/Aß42/Aß40 ratio (AUC=0.817; 95% CI: 0.734-0.901), and Aß42 (AUC=0.812; 95% CI: 0.722-0.902). Performance was slightly lower for the tTau/Aß42/Aß40 ratio (AUC=0.799; 95% CI: 0.713-0.885), pTau181 alone (AUC=0.793; 95% CI: 0.707-0.880), tTau/Aß40 ratio (AUC=0.751; 95% CI: 0.657-0.844), and tTau alone (AUC=0.706; 95% CI: 0.613-0.799). The highest qualitative performance was observed with the pTau181/Aß42 ratio with an established cut-off value of >0.024 and optimized cut-off value of >0.022: sensitivity and specificity values were 0.892 and 0.773, respectively. CONCLUSIONS: Elecsys CSF immunoassays demonstrate good diagnostic accuracy in differentiating patients with AD from those with FTLD. These immunoassays have the potential to support clinical decision making, i.e. in diagnosing patients with FTLD by excluding patients with amyloid positivity, which is indicative of underlying AD.


Assuntos
Doença de Alzheimer , Afasia Primária Progressiva , Demência Frontotemporal , Degeneração Lobar Frontotemporal , Doença de Alzheimer/líquido cefalorraquidiano , Doença de Alzheimer/diagnóstico , Peptídeos beta-Amiloides/líquido cefalorraquidiano , Biomarcadores/líquido cefalorraquidiano , Demência Frontotemporal/líquido cefalorraquidiano , Degeneração Lobar Frontotemporal/líquido cefalorraquidiano , Degeneração Lobar Frontotemporal/diagnóstico , Humanos , Estudos Retrospectivos , Proteínas tau/líquido cefalorraquidiano
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA